Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
REEKON Tools, Inc. Address: 50 Terminal St. BLDG 2 STE 611 Charlestown, MA 02129 United States Date: July 20, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for T1R-16-001, RKN-T1R-16-002 and RKN-T1R-16-003 [REEKON Tools, Inc.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, Applicant Signature Printed Name: Christian Reed Title: : CEO Address: 50 Terminal St. BLDG 2 STE 611 Charlestown, MA 02129 United States Tel.: (617) 466-9060 Email: [email protected] REEKON Tools, Inc. Address: 50 Terminal St. BLDG 2 STE 611 Charlestown, MA 02129 United States Date: July 20, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for T1R-16-001, RKN-T1R-16-002 and RKN-T1R-16-003 [REEKON Tools, Inc.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Applicant Signature Printed Name: Christian Reed Title: : CEO Address: 50 Terminal St. BLDG 2 STE 611 Charlestown, MA 2129 United States Tel.: (617) 466-9060 Email: [email protected]
Attestation Statements Date: July 20, 2026 TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for QKH-KYPG2 [REEKON Tools, Inc.], the undersigned, hereby authorize (REEKON Tools, Inc.) to act as our designated U.S. agent for service of process, [REEKON Tools, Inc.] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. (REEKON Tools, Inc.) accepts the responsibility to act as designated U.S. agent for service of process. Applicant Information: Company name:REEKON Tools, Inc. Contact Name:Christian Reed Address:50 Terminal St. BLDG 2 STE 611 Charlestown, MA 02129 United States FRN: 0033917915 Telephone No:(617) 466-9060 Email:[email protected] Signature U.S. Agent Information: Company Name: REEKON Tools, Inc. Address:50 Terminal St. BLDG 2 STE 611 Charlestown, MA 02129 United States FRN:0033917915 Contact Name: Christian Reed Telephone No: (617) 466-9060 Email:[email protected] Signature
REEKONTools,Inc. Add:50TerminalSt.BLDG2STE611,Charlestown,MA02129USA Tel:(617)466-9060 Date:2026-07-20 DearSir/Madam, We,REEKONTools,Inc.Herebydeclaresthefollowingstatement,anyofourproduction units bearingthefollowingmodelnumbersareidenticalincircuitryandelectrical,mechanicaland physicalconstruction;theonlydifferences:Theappearance,material,internalcircuitryand actualphysicaldimensionsofeachsampleinthisseriesareallidentical.Onlythe measurementunitofTapeBladeisdifferent. Thereare3xTotalSKUs-3modelsofTapeBladeUnitlabelscreenprinting,unitscale (English,Metric,Split),Itisthenon-electronicandhasnoimpactontheFCCtestresult. RKN-T1R-16-001-T1RRangeHybridMeasuringTool-16ft-English, RKN-T1R-16-002-T1RRangeHybridMeasuringTool-16ft-Metric, RKN-T1R-16-003-T1RRangeHybridMeasuringTool-16ft-Split. RKN-T1R-16-001:16ft-English RKN-T1R-16-002:16ft-Metric RKN-T1R-16-003:16ft-Split. Productname:T1RRangeHybridMeasuringTool ModelsNo.:RKN-T1R-16-001,RKN-T1R-16-002,RKN-T1R-16-003 IC: Sincerely, Client’sname/title: ChristianReed/CEO Contactinformation/address:REEKONTools,Inc./50TerminalSt.BLDG2STE611, Charlestown,MA02129USA Tel:(617)466-9060 E-Mail:[email protected]
REEKON Tools, Inc. Address: 50 Terminal St. BLDG 2 STE 611 Charlestown, MA 02129 United States Date: July 20, 2026 Sincerely yours Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization for FCC ID: 2BBSG-RKNT1R001 I, the undersigned, hereby authorize Keyway Testing Technology(Guangdong) Co., Ltd. to act on our behalf in all matters relating to this application for equipment certification. Any act carried out by Keyway Testing Technology(Guangdong) Co., Ltd. shall have the same effect as our own and I acknowledge that all responsibility for complying with the terms and conditions of certification, as specified by Eurofins Electrical and Electronic Testing NA, Inc., still resides with REEKON Tools, Inc. We certify that we are not subject to a denial of federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862, and that no party to the application, as defined in 47 CFR §1.2002(b), is subject to a denial of federal benefits that includes FCC benefits pursuant to that section. , Applicant Signature Printed Name: Christian Reed Title: : CEO Address: 50 Terminal St. BLDG 2 STE 611 Charlestown, MA 02129 United States Tel.: (617) 466-9060 Email: [email protected]
REEKON Tools, Inc. Address: 50 Terminal St. BLDG 2 STE 611 Charlestown, MA 02129 United States Date: July 20, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR T1R Range Hybrid Measuring Tool/RKN-T1R-16-001, RKN-T1R-16-002 and RKN-T1R-16-003. To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (Block Diagram, Schematics, Operational Description) required to be submitted with this application be permanently withheld from public review. the above documents are company proprietary information that could never get into the possession of your competition). Please contact me if there is any information you may need. Sincerely, SCH,Block, Applicant Signature Printed Name: Christian Reed Title: : CEO Address: 50 Terminal St. BLDG 2 STE 611 Charlestown, MA 02129 United States Tel.: (617) 466-9060 Email: [email protected]
REEKON Tools, Inc. Address: 50 Terminal St. BLDG 2 STE 611 Charlestown, MA 02129 United States Date: July 20, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize [Cherry Chen at Keyway Testing Technology(Guangdong) Co., Ltd. ] to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Applicant Signature Printed Name: Christian Reed Title: : CEO Address: 50 Terminal St. BLDG 2 STE 611 Charlestown, MA 02129 United States Tel.: (617) 466-9060 Email: [email protected]
REEKON Tools, Inc. Address: 50 Terminal St. BLDG 2 STE 611 Charlestown, MA 02129 United States Date: July 20, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 To Whom It May RE: Short Term Confidentiality Request ForT1R Range Hybrid Measuring Tool/ RKN-T1R-16-001, RKN-T1R-16-002 and RKN-T1R-16-003. Concern: In accordance with sections 0.457 and 0.459 of CFR 47, [REEKON Tools, Inc.]. requests short-term Confidentiality of following sections of this application for a period of 45 days after grant is issued. Test setup photos External photos Internal photos User’s manual These documents contain detailed system and equipment descriptions and related information about the product, which [REEKON Tools, Inc.] considers to be proprietary, confidential, and a custom design and otherwise, would not be released to the general public. Since this design is a basis from which future technological products will evolve, [REEKON Tools, Inc.] feels that this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Applicant Signature Printed Name: Christian Reed Title: : CEO Address: 50 Terminal St. BLDG 2 STE 611 Charlestown, MA 02129 United States Tel.: (617) 466-9060 Email: [email protected]
T1R - Product Label Location: RKN-T1R-16-001 Product of Thailand | Assembled in China RANGE CAN ICES-003(B) / NMB-003(B) FCC ID: 2BBSG-RKNT1R001 IC: 30816-RKNT1R001 USB-C PD 5–9 ≤3 A Complies with 21 CFR Chapter 1, Subchapter J. RKN-T1R-16-001 WilsonSeaDragon Product of Thailand | Assembled in China RANGE FCC ID: 2BBSG-RKNT1R001 CAN ICES-003(B) / NMB-003(B) IC: 30816-RKNT1R001 USB-C PD 5–9 ≤ 3 A Complies with 21 CFRChapter 1, Subchapter J. RKN-T1R-16-001 WilsonSeaDragon HVIN:RKN-T1R-16-001 T1R - Product Label Location: RKN-T1R-16-002 Product of Thailand | Assembled in China RANGE FCC ID: 2BBSG-RKNT1R001 CAN ICES-003(B) / NMB-003(B) IC: 30816-RKNT1R001 USB-C PD 5–9 ≤3 A Complies with 21 CFR Chapter 1, Subchapter J. RKN-T1R-16-002 WilsonSeaDragon Product of Thailand | Assembled in China RANGE FCC ID: 2BBSG-RKNT1R001 CAN ICES-003(B) / NMB-003(B) IC: 30816-RKNT1R001 USB-C PD 5–9 ≤ 3 A Complies with 21 CFRChapter 1, Subchapter J. RKN-T1R-16-002 WilsonSeaDragon HVIN:RKN-T1R-16-002 T1R - Product Label Location: RKN-T1R-16-003 Product of Thailand | Assembled in China RANGE FCC ID: 2BBSG-RKNT1R001 CAN ICES-003(B) / NMB-003(B) IC: 30816-RKNT1R001 USB-C PD 5–9 ≤3 A Complies with 21 CFR Chapter 1, Subchapter J. RKN-T1R-16-003 WilsonSeaDragon Product of Thailand | Assembled in China RANGE FCC ID: 2BBSG-RKNT1R001 CAN ICES-003(B) / NMB-003(B) IC: 30816-RKNT1R001 USB-C PD 5–9 ≤ 3 A Complies with 21 CFRChapter 1, Subchapter J. RKN-T1R-16-003 WilsonSeaDragon HVIN:RKN-T1R-16-003
FCCID:2BBSG-RKNT1R001 RFExposureEvaluation 1.1.ApplicableStandard Accordingto§1.1307(b)(1),systemsoperatingundertheprovisionsofthissectionshallbe operatedinamannerthatensuresthatthepublicisnotexposedtoradiofrequencyenergy levelinexcessoftheCommission’sguidelines. Accordingto§1.1310and§2.1093RFexposureiscalculated. KDB447498v06:MobileandPortableDevicesRFExposureProceduresandEquipment AuthorizationPolicies. 1.2.Requirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06Section4.3.1 StandaloneSARtestexclusionconsiderations:“Unlessspecificallyrequiredbythe publishedRFexposureKDBprocedures,standalone1-gheadorbodyand10-gextremity SARevaluationforgeneralpopulationexposureconditions,bymeasurementornumerical simulation,isnotrequiredwhenthecorrespondingSARTestExclusionThreshold condition,listedbelow,issatisfied.Thesetestexclusionconditionsarebasedon source-basedtime-averagedmaximumconductedoutputpoweroftheRFchannel requiringevaluation,adjustedfortune-uptolerance,andtheminimumtestseparation distancerequiredfortheexposureconditions.22Theminimumtestseparationdistanceis determinedbythesmallestdistancefromtheantennaandradiatingstructuresorouter surfaceofthedevice,accordingtothehostformfactor,exposureconditionsandplatform requirements,toanypartofthebodyorextremityofauserorbystander(see5)ofsection 4.1).ToqualifyforSARtestexclusion,thetestseparationdistancesappliedmustbefully explainedandjustifiedbytheoperatingconfigurationsandexposureconditionsofthe transmitterandapplicablehostplatformrequirements,typicallyintheSARmeasurementor SARanalysisreport,accordingtotherequiredpublishedRFexposureKDBprocedures. WhennootherRFexposuretestingorreportingisrequired,astatementofjustificationand compliancemustbeincludedintheequipmentapproval,inlieuoftheSARreport,toqualify fortheSARtestexclusion.Whenrequired,thedevicespecificconditionsdescribedinthe otherpublishedRFexposureKDBproceduresmustbesatisfiedbeforeapplyingtheseSAR testexclusionprovisions;forexample,handheldPTTtwo-wayradios,handsets,laptops& tabletsetc.23“[(max.powerofchannel,includingtune-uptolerance,mW)/(min.test separationdistance,mm)]·[√f(GHz)]≤3.0for1-gSARand≤7.5for10-gextremitySAR, where: •f(GHz)istheRFchanneltransmitfrequencyinGHz •PoweranddistanceareroundedtothenearestmWandmmbeforecalculation •Theresultisroundedtoonedecimalplaceforcomparison •3.0and7.5arereferredtoasthenumericthresholdsinthestep2belowThetest exclusionsareapplicableonlywhentheminimumtestseparationdistanceis≤50mmand fortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmaccordingto5)insection4.1isapplied todetermineSARtestexclusion. 1.3.Manufacturingtolerance 1.4.EvaluationResult Band/Mode f (GHz) Antenna Distance (mm) RFoutputpower (including tune-up tolerance) SARTest Exclusion Threshold SARTest Exclusion dBmmW BT(BLE-1M)2.48052.01.580.50<3.0Yes BT(BLE-2M)2.48052.01.580.50<3.0Yes Note:Result=P F /D P=Maximumturn-uppowerinmW F=ChannelfrequencyinGHz D=Mininmuntestseparationdistanceinmm 1.5.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1093fortheuncontrolledRF ExposureandSARExclusionThresholdperKDB447498v06,NoSARisrequired. BLE GFSK ChannelChannel00Channel19Channel39 LETarget(dBm)0.00.51.0 Tolerance±(dB)1.01.01.0 2LETarget(dBm)0.00.51.0 Tolerance±(dB)1.01.01.0
ReportNo.2026071019588563-00 LaboratoryAddress:Room2102,Building6,DongyiIntelligentEquipmentNewEnergyVehiclePark,No.30of TangxiaDistrict,DongshenRoad,TangxiaTown,Dongguan,523710,People'sRepublicofChina Tel:0769-87182258E-mail:[email protected]:www.keywaytest.com REV.00 Page 1 of 47 FCCPart15C&RSS-247TESTREPORT FCCID:2BBSG-RKNT1R001 IC:30816-RKNT1R001 Preparedfor:REEKONTools,Inc. Address:50TerminalSt.BLDG2STE611,Charlestown, MA02129USA TradeName:REEKON E.U.T:T1RRangeHybridMeasuringTool ModelNumber:RKN-T1R-16-001 SeriesModel:RKN-T1R-16-002,RKN-T1R-16-003 Preparedby:KeywayTestingTechnology(Guangdong)Co.,Ltd. Address:Room2102,Building6,DongyiIntelligent EquipmentNewEnergyVehiclePark,No.30of TangxiaDistrict,DongshenRoad,TangxiaTown, Dongguan,523710,People'sRepublicofChina Tel:86-769-87182258 Fax:86-769-87181058 ReportNo.:2026071019588563-00 DateofTest::Jun.12~Jul.12,2026 DateofReport:Jul.13,2026 ReportNo.2026071019588563-00 LaboratoryAddress:Room2102,Building6,DongyiIntelligentEquipmentNewEnergyVehiclePark,No.30of TangxiaDistrict,DongshenRoad,TangxiaTown,Dongguan,523710,People'sRepublicofChina Tel:0769-87182258E-mail:[email protected]:www.keywaytest.com REV.00 Page 2 of 47 KeywayTestingTechnology(Guangdong)Co.,Ltd. Applicant: REEKONTools,Inc. Address: 50TerminalSt.BLDG2STE611,Charlestown,MA02129USA Manufacturer: HuizhouZhengchengAudioCo.,Ltd Address: IntercontinentalIndustrialPark,LuoyangStreet,BoluoCounty,Huizhou City TradeName: REEKON E.U.T: T1RRangeHybridMeasuringTool ModelNumber: RKN-T1R-16-001 SeriesModel: RKN-T1R-16-002,RKN-T1R-16-003 DateofReceipt: Jun.11,2026 DateofTest: Jun.12~Jul.12,2026 TestSpecification: FCCCFR47Part15Section15.247 RSS-247Issue4:July24,2025 ANSIC63.10-2020+Cor.1-2023+C63.10a-2024+ErratatoC63.10a-2024 RSS-GENIssue5,Amendment2,February,2021 TestResult: Theequipmentundertestwasfoundtobecompliancewiththe requirementsofthestandardsapplied. IssueDate:Jul.13,2026 Testedby: Reviewedby: Authorizedby: BearXiongHughZhangCherryChen Abbreviations:OK/P=passedfail/F=failedN/A=notapplicableE.U.T=equipmentundertested ThisdevicedescribedabovehasbeentestedbyKeyway,andthetestresultsshowthattheequipmentundertest(EUT)isin compliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofKeyway,thisdocumentmaybealteredorrevised byKeyway,personalonly,andshallbenotedintherevisionofthedocument. ReportNo.2026071019588563-00 LaboratoryAddress:Room2102,Building6,DongyiIntelligentEquipmentNewEnergyVehiclePark,No.30of TangxiaDistrict,DongshenRoad,TangxiaTown,Dongguan,523710,People'sRepublicofChina Tel:0769-87182258E-mail:[email protected]:www.keywaytest.com REV.00 Page 3 of 47 RevisionRecord VersionChapterDateModifierRemark 002026.07.13 Original ReportNo.2026071019588563-00 LaboratoryAddress:Room2102,Building6,DongyiIntelligentEquipmentNewEnergyVehiclePark,No.30of TangxiaDistrict,DongshenRoad,TangxiaTown,Dongguan,523710,People'sRepublicofChina Tel:0769-87182258E-mail:[email protected]:www.keywaytest.com REV.00 Page 4 of 47 Contents Page 2TESTSUMMARY.............................................................................................................................................................6 2.1TESTSITE..............................................................................................................................................................7 3GENERALINFORMATION............................................................................................................................................8 3.1GENERALDESCRIPTIONOFE.U.T.......................................................................................................................8 3.2CHANNELLIST.......................................................................................................................................................9 3.3TESTSETUPCONFIGURATION............................................................................................................................10 3.4TESTMODE..........................................................................................................................................................10 4EQUIPMENTDURINGTEST.......................................................................................................................................11 4.1EQUIPMENTSLIST................................................................................................................................................11 4.2MEASUREMENTUNCERTAINTY............................................................................................................................13 4.3DESCRIPTIONOFSUPPORTUNITS.....................................................................................................................13 5CONDUCTEDEMISSION............................................................................................................................................14 5.1E.U.T.OPERATION..............................................................................................................................................14 5.2EUTSETUP.........................................................................................................................................................14 5.3TESTSET-UP(BLOCKDIAGRAMOFCONFIGURATION)...................................................................................15 5.4MEASUREMENTPROCEDURE..............................................................................................................................15 5.5CONDUCTEDEMISSIONLIMIT..............................................................................................................................15 5.6MEASUREMENTDESCRIPTION.............................................................................................................................15 5.7CONDUCTEDEMISSIONTESTRESULT.............…
Text truncated - open the document above for the full version.
KeywayTestingTechnology(Guangdong)Co.,Ltd Room2102,Building6,DongyiIntelligentEquipmentNewEnergyVehiclePark, No.30ofTangxiaDistrict,DongshenRoad,TangxiaTown,Dongguan,523710,People'sRepublicofChina Telephone:+86(769)87182258www.keywaytest.com RFConductedTest- appendixIIIBluetooth_(BLEBluetooth)_Testdata. E.U.T:T1RRangeHybridMeasuringTool ModelNumber:RKN-T1R-16-001 SampleID33000276579 Sample(s)Status:Engineersample DateofReceipt:2026.06.11 DateofTest:2026.06.12~2026.07.10 FCCID:2BBSG-RKNT1R001 IC:30816-RKNT1R001 ReportNo.2026071019588563-00 TesterRayZhu KeywayTestingTechnology(Guangdong)Co.,Ltd Room2102,Building6,DongyiIntelligentEquipmentNewEnergyVehiclePark, No.30ofTangxiaDistrict,DongshenRoad,TangxiaTown,Dongguan,523710,People'sRepublicofChina Telephone:+86(769)87182258www.keywaytest.com A.1DUTYCYCLE TestResult ModeChannel OnTime (ms) Period(ms) DutyCycle (%) DutyCycle (linear) DutyCycle Factor(dB) 1/T BLE1M 00.3930.62562.880.62882.01492.5445 190.3930.62562.880.62882.01492.5445 390.3930.62562.880.62882.01492.5445 BLE2M 00.2090.62533.440.33444.75734.7847 190.2080.62533.280.33284.77824.8077 390.2080.62533.280.33284.77824.8077 Note:inputcompensationcoeffcient(dB)=CableLoss(dB) TestGraphs BLE1M_Channel0BLE1M_Channel19 BLE1M_Channel39BLE2M_Channel0 BLE2M_Channel19BLE2M_Channel39 KeywayTestingTechnology(Guangdong)Co.,Ltd Room2102,Building6,DongyiIntelligentEquipmentNewEnergyVehiclePark, No.30ofTangxiaDistrict,DongshenRoad,TangxiaTown,Dongguan,523710,People'sRepublicofChina Telephone:+86(769)87182258www.keywaytest.com A.2POWERSPECTRALDENSITY TestResult ModeChannelPSD(dBm/3kHz)Limit(dBm/3kHz)Result BLE1M0-15.67≤8PASS BLE1M19-15.41≤8PASS BLE1M39-14.98≤8PASS BLE2M0-19.14≤8PASS BLE2M19-18.99≤8PASS BLE2M39-18.60≤8PASS Note:inputcompensationcoeffcient(dB)=CableLoss(dB) TestGraphs BLE1M_Channel0BLE2M_Channel0 BLE1M_Channel19BLE2M_Channel19 BLE1M_Channel39BLE2M_Channel39 KeywayTestingTechnology(Guangdong)Co.,Ltd Room2102,Building6,DongyiIntelligentEquipmentNewEnergyVehiclePark, No.30ofTangxiaDistrict,DongshenRoad,TangxiaTown,Dongguan,523710,People'sRepublicofChina Telephone:+86(769)87182258www.keywaytest.com A.3CONDUCTEDPEAKOUTPUTPOWER TestResult ModeChannel PeakOutput Power (dBm) PeakOutput Power (mW) Max.Avg. Power (dBm) Limit (dBm) Result BLE1M 0-0.130.97None≤30PASS 190.101.02None≤30PASS 390.521.13None≤30PASS BLE2M 0-0.090.98None≤30PASS 190.121.03None≤30PASS 390.581.14None≤30PASS Note:inputcompensationcoeffcient(dB)=CableLoss(dB) ModeChannel PeakOutput Power (dBm) PeakPower Limit (dBm) ISEDEIRP (dBm) ISEDEIRP Limit (dBm) Max.Avg. Power (dBm) Result BLE1M 0-0.13≤30-0.13≤36.02NonePASS 190.10≤300.10≤36.02NonePASS 390.52≤300.52≤36.02NonePASS BLE2M 0-0.09≤30-0.09≤36.02NonePASS 190.12≤300.12≤36.02NonePASS 390.58≤300.58≤36.02NonePASS Note:inputcompensationcoeffcient(dB)=CableLoss(dB) TestGraphs PeakOutputPower BLE1M_Channel0 PeakOutputPower BLE1M_Channel19 PeakOutputPower BLE1M_Channel39 PeakOutputPower BLE2M_Channel0 KeywayTestingTechnology(Guangdong)Co.,Ltd Room2102,Building6,DongyiIntelligentEquipmentNewEnergyVehiclePark, No.30ofTangxiaDistrict,DongshenRoad,TangxiaTown,Dongguan,523710,People'sRepublicofChina Telephone:+86(769)87182258www.keywaytest.com PeakOutputPower BLE2M_Channel19 PeakOutputPower BLE2M_Channel39 KeywayTestingTechnology(Guangdong)Co.,Ltd Room2102,Building6,DongyiIntelligentEquipmentNewEnergyVehiclePark, No.30ofTangxiaDistrict,DongshenRoad,TangxiaTown,Dongguan,523710,People'sRepublicofChina Telephone:+86(769)87182258www.keywaytest.com A.499%BANDWIDTH TestResult ModeChannelCenterFrequency(MHz)99%BW(MHz) BLE1M024021.0409 BLE1M1924401.0420 BLE1M3924801.0407 BLE2M024022.0490 BLE2M1924402.0602 BLE2M3924802.0569 Note:inputcompensationcoeffcient(dB)=CableLoss(dB) TestGraphs BLE1M_Channel0BLE2M_Channel0 BLE1M_Channel19BLE2M_Channel19 BLE1M_Channel39BLE2M_Channel39 KeywayTestingTechnology(Guangdong)Co.,Ltd Room2102,Building6,DongyiIntelligentEquipmentNewEnergyVehiclePark, No.30ofTangxiaDistrict,DongshenRoad,TangxiaTown,Dongguan,523710,People'sRepublicofChina Telephone:+86(769)87182258www.keywaytest.com A.56DBBANDWIDTH TestResult ModeChannel CenterFrequency (MHz) 6dBBandwidth (MHz) Limit (MHz) Result BLE1M 024020.7024 ≥0.5 PASS 1924400.7115PASS 3924800.7142PASS BLE2M 024021.205PASS 1924401.205PASS 3924801.202PASS Note:inputcompensationcoeffcient(dB)=CableLoss(dB) TestGraphs BLE1M_Channel0BLE2M_Channel0 BLE1M_Channel19BLE2M_Channel19 BLE1M_Channel39BLE2M_Channel39 KeywayTestingTechnology(Guangdong)Co.,Ltd Room2102,Building6,DongyiIntelligentEquipmentNewEnergyVehiclePark, No.30ofTangxiaDistrict,DongshenRoad,TangxiaTown,Dongguan,523710,People'sRepublicofChina Telephone:+86(769)87182258www.keywaytest.com A.6CONDUCTEDSPURIOUS&BANDEDGEEMISSION TestResult ModeChannel OOBEmission Frequency (MHz) OOBEmission Level (dBm) Limit (dBm) OverLimit (dB) Result BLE1M 0 2400.00-50.765-20.22-30.545PASS 2497.72-51.461-20.22-31.241PASS 192535.80-52.141-20.0-32.141PASS 39 2483.50-55.065-19.53-35.535PASS 2576.38-51.211-19.53-31.681PASS BLE2M 0 2400.00-31.595-20.27-11.325PASS 2497.72-49.250-20.27-28.980PASS 192533.93-49.618-20.05-29.568PASS 39 2483.50-53.872-19.57-34.302PASS 2575.76-49.557-19.57-29.987PASS Note:inputcompensationcoeffcient(dB)=CableLoss(dB) TestGraphs In-BandReferenceLevel BLE1M_Channel0 In-BandReferenceLevel BLE2M_Channel0 OutOfBandEmission BLE1M_Channel0 OutOfBandEmission BLE2M_Channel0 30.0MHz-25000.0MHz BLE1M_Channel0 30.0MHz-25000.0MHz BLE2M_Channel0 KeywayTestingTechnology(Guangdong)Co.,Ltd Room2102,Building6,DongyiIntelligentEquipmentNewEnergyVehiclePark, No.30ofTangxiaDistrict,DongshenRoad,TangxiaTown,Dongguan,523710,People'sRepublicofChina Telephone:+86(769)87182258www.keywaytest.com In-BandReferenceLevel BLE1M_Channel19 In-BandReferenceLevel BLE2M_Channel19 30.0MHz-25000.0MHz BLE1M_Channel19 30.0MHz-25000.0MHz BLE2M_Channel19 In-BandReferenceLevel BLE1M_Channel39 In-BandReferenceLevel BLE2M_Channel39 OutOfBandEmission BLE1M_Channel39 OutOfBandEmission BLE2M_Channel39 KeywayTestingTechnology(G…
Text truncated - open the document above for the full version.
XINGCI αδ JIANCE Report No.: XCL-AB202504-0027 TEST REPORT Product Name: T1M Utility Digital Tape Measure PCB Antenna Model: T1M Utility Digital Tape Measure Test Sort: External Commission Test Client: REEKON Tools, Inc. Test by: Xingci Lab GUANGDONG XINGCI EFFT 术 究 TESTING TECHNOLOGY RESEARCH Co.,Ltd. 检测专用章 Page 1 of 10 R-XC-COP30-06V1.1 Announcement 1. This report is invalid without seal. Report No.: XCL-AB202504-0027 2. This report must not be partially duplicated without permission. 3. The manufacturer would be responsible for the test samples. 4. Xingci Lab would be only responsible for report items of the test sample, this test result is only used for scientific research, teaching, and internal control, and does not have a proof function to the society. 5. If the client has any question about the test report, please contact our lab as agreed within 15 days. Disagreement couldn't be accepted over 15 days. 6. Test report inquires telephone No.:+ 86-757-87744743 Add: No#4, Jinye 2nd road, Yundonghai street, Sanshui, Foshan, Guangdong Province, China, 528100 Tel: 0086-(0757)-87744743 Post Code: 528100 Page 2 of 10 R-XC-COP30-06V1.1 Report No.: XCL-AB202504-0027 Test Report T1M Utility Digital Tape Product Name Measure PCB Antenna Manufacture Date T1M Utility Digital Tapе Product Model Brand Name REEKON Measure REEKON Tools, Inc. Name Client Address Test Type Test Place Sample Qty Test Environment 50 Terminal St.BLDG 2 STE 611, Charlestown, MA 02129 USA External Commission Test SG128 Anechoic Chamber (Guangdong Xingci testing technology research Co., Ltd.) 1pc Test Date Apr. 11, 2025 Temperature: (23~23.2) °C Relative Humidity: (69.1~69.2)% Test Item Electrical performance: Radiation Pattern, Gain Test Standard According to the client's requirements, refer to the following standard: IEEE Std 149TM-2021 IEEE Recommended Practice for Antenna Measurements Test Description Remarks Tested by: Li Jia Shong Date: Apr. I1, 2025 Guangdong Xingci testing technology research Co., Ltd. tested the electrical performance of 1pc of T1M Utility Digital Tape Measure PCB Antenna under the guideline of relevant standard. Please see test result in page 5, Radiation Patterns in pages 6-8. Checked by: zhang xiao jun Date: Apr. 25, 2015 Approvee by: (Autnorized signatory angemmongdivng Date 公测专用章 Page 3 of 10 R-XC-COP30-06V1.1 Sample Description Yes: Accessories No Report No.: XCL-AB202504-0027 Outlook/Appearance Qualified Unqualified: Status at the beginning of Test Status after Test Working Normally Working Abnormally: Working Normally Other: Photograph Remarks (Provided by the customer Item 1 No In page 9 Antenna size: 8.48mm×2.53mm Device size: 43.91mm×28.28mm Device weight: 0.025kg Sample Number Serial Number Sample Number AB2025041102 Page 4 of 10 / R-XC-COP30-06V1.1 Report No.: XCL-AB202504-0027 Electrical Performance Test Result Item Test Item Technical Requirement Unit Test Frequency (MHz) Test Result 2400 -1.44 2410 -2.40 2420 -1.69 2430 -2.01 2440 -1.93 1 Gain / dBi2450 -2.17 2460 -2.55 2470 -2.35 2480 -3.29 2490 -2.81 2500 -4.02 2 Radiation Pattern 2400-2500 Pages 6-8 Note: Test Method: Near Field Measurement Method. This page is blank below Page 5 of 10 R-XC-COP30-06V1.1 Report No.: XCL-AB202504-0027 Radiation Pattern 2D Vertical Radiation Pattern Horizontal Radiation Pattern L00 MH 2420 00MH 2450 2460 00MH Gain / 20.000 Page 6 of 10 R-XC-COP30-06V1.1 3D 2400MHz -144 Report No.: XCL-AB202504-0027 2410MHz -2.40 -36.61 -35.31 2420MHz 2430MHz -1.69 -2.01 -37.62 -41.21 2440MHz 2450MHz -1.93 -36.01 -2.17 -36.26 Page 7 of 10 R-XC-COP30-06V1.1 Report No.: XCL-AB202504-0027 2460MHz 2470MHz -2.55 -39.25 2480MHz -3.29 -2.35 -37.77 2490MHz -2.81 -44.67 -44.77 2500MHz -4.02 -37.04 3 Page 8 of 10 R-XC-COP30-06V1.1 90100 10 20 ) 90100 10 20 Sample photo 0.81 0.81 Report No.: XCL-AB202504-0027 -1.98 0.80 2.00 -8.48- TO PCB 2.53< Units in mm. 0.36mm trace width. T1m Main PCB REVO Radiation Pattern Test site Page 9 of 10 R-XC-COP30-06V1.1 Report No.: XCL-AB202504-0027 Main instruments and equipment for testing and test system No. NAME Model SERIAL NUMBER VALIDITY DATE (DD/MM/YY) 1 Standard Gain Antenna SH400-374 XCA079 27/05/2025 2 Microwave Anechoic Chamber 11m×10m×10m XCC02 16/05/2027 3 SG128 Antenna Test System SG128 1102333-0008 08/11/2025 4 Wave Studio 22.3.2 XCXT10 N/A ----------End of Report- Page 10 of 10 R-XC-COP30-06V1.1
50 Terminal St. BLDG 2 STE 611 Charlestown, MA 212 · Charlestown · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 800.00 µW |

Bluetooth Label Printer
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter