2BBSLLORASCALEV5HKSmart Bin Waste Scale with LoRa Transmission

Spare-it, Inc.
Smart Bin Waste Scale with LoRa Transmission - FCC ID 2BBSLLORASCALEV5HK - Spare-it, Inc.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Oct 29, 2023
Application Purpose
Original Equipment
Date of Application
Oct 29, 2023
Equipment Note
Smart Bin Waste Scale with LoRa Transmission
Frequency Range
923.20000000 - 924.60000000
Company
Spare-it, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Spareit Scale – User Manual Sep 14, 2023 V2 1. Introduction The Spare-it Scale is designed to be placed under an office trash bin to automatically report weight changes to the cloud over LoRa connectivity. 2. Specs - Size: 32 x 32 cm - Connectivity: LoRa - 1 configuration port - 4 batteries 3. Inputs and outputs - 1 LED: o Blinks when connecting to LoRa gateway o 1 second blink after successful connection to LoRa gateway before going to sleep mode 4. Initial setup 4.1. Place batteries into the Spare-it Scale (the Spare-it Scale will automatically connect when nearby a Spare-it gateway) 4.2. Position the Spare-it Scale below a track bin 5. Normal operations When users are putting trash in the bin, the Spare-it Scale will automatically measure the new weight and report the value to the cloud using the LoRa connection. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.

Attestation Statements

Form: RFT-AMER-TCB-OP-19o Revision: 1 Page 1 of 1 Date: 1/25/2023 Attention: Application Examiner Re: Certification designating a U.S. agent for service of process pursuant to 47 CFR part §2.911(d)(7) of the FCC rules To whom it may concern, This letter is to certify that Spare-it, Inc. (“Applicant”) accepts responsibilities to act as its own agent pursuant to 47 CFR part §2.911(d)(7) of the FCC rules for service of process. I consent to the obligation to accept service of process on behalf of the Applicant for all certification applications to the F CC. I HEREBY CERTIFY THAT I am authorized to make the representations above on behalf of the Applicant. I further acknowledge the requirement to maintain an agent extends for no less than one year after the termination of all marketing and importation or the conclusion of and commission-related proceeding involving the equipment and agree to immediately notify the FCC and Intertek if there is any change in the status identified above. Applicant Company Name Contact Name Address Telephone No Email Applicant FRN : Spare-it, Inc. : Laurent Meunier : 444 Somerville Ave, Somerville, Massachusetts 02143, US : +1 978 761 9211 : [email protected] : 0033918087 Signature: ____________________________________ Date: ____________________________________ 30th June 2023

Attestation Statements

Form: RFT-AMER-TCB-OP-19n Revision: 1 Page 1 of 1 Date: 1/25/2023 Attention: Application Examiner Re: Covered List, located at https://www.fcc.gov/supplychain/coveredlist and 47 CFR parts §2.903 and §2.911(d)(5)(ii) of the FCC rules Applicant: Spare-it, Inc. FCC ID: 2BBSLLORASCALEV5HK To whom it may concern, Spare-it, Inc. (“Applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to 47 CFR part §2.903 of the FCC rules and does not originate directly or indirectly from any company named on the covered list located in the link above or any subsidiary or affiliate thereof. Applicant further certifies that, as of the date of the filing of the application, the Applicant is not identified on the Covered List as an entity producing “covered” equipment and is not a subsidiary or affiliate of any such entity pursuant to 47 CFR part §1.50002 and required by 47 CFR part §2.911(d)(5)(ii) of the FCC rules. I HEREBY CERTIFY THAT I am authorized to make the representations above on behalf of the Applicant and agree to immediately notify Intertek if there is any change in the status identified above. ______________________________ [Signature of authorized Proprietor, Partner or Authorized Officer] Laurent Meunier COO Spare-it, Inc. Sept 12, 2023

Cover Letter(s)

Letter of Agency I, an officer of Spare-it, Inc. do hereby authorize Intertek Testing Services (Mr. Tim Lee / Herbert Wong / Kenneth Wong) to act on our behalf in front of the Federal Communications Commission with respect to all matters relating to certification of equipment under Part 15 and Part 18 of the FCC Rules until further notice. I further certify that no party (as defined in §1.2002(b) of CFR 47, 2004) to this application, including myself, is subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti -Drug Abuse Act of 1988, 21 U.S.C.,862. Date: June 13th, 2023 By Signature Printed Name: Laurent Meunier Title: Co-founder and CTO Remark: The person who signs this authorization letter must be the grantee contact of record in the Grantee Code data base. Dec 2013

Cover Letter(s)

1(1) September 17th, 2023 Attention: Application Examiner RE: Request for Confidentiality Applicant: Spare-it, Inc. FCC ID: 2BBSLLORASCALEV5HK To Whom It May Concern: Permanent Confidentiality Request is hereby submitted by Spare-it, Inc. to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: • Schematics • Detailed Block Diagrams • Detailed Operational/Functional Description Rationale for request for confidentiality: Spare-it, Inc. has invested considerable time and materials in research and development to produce the referenced product. [Permanent confidentiality: Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. The fee for confidentiality has been submitted along with the fee for certification.] If you have questions or need further information, please contact the undersigned. Sincerely, [Signature] Laurent Meunier COO Spare-it, Inc.

External Photos

INTERTEK TESTING SERVICE Report No.: HK22071098 Equipment Photographs (External)

ID Label/Location Info

letter size 5 mm height 7 mm LABEL SIZE 43MM x 20MM Product Name: Spare-it Scale Model: SPT-002 Maximum capacity: 396lb/180kg Power: 4XAAA batteries FCC ID: 2BBSLLORASCALEV5HK Made in China 技术要求: 1、黏合不可露胶; 2、保持印刷面板上的清洁; 3、注意套印的准确性; 4、表面处理不可爆开; 5、所用材料及工艺须满足RoHS、Reach的环保要求; 6、结构工艺以结构受控图为准; 7、通用要求:成型后制品以《不干胶类来料检验标准》验收; 8、测试要求:保证产品在60°C,48小时的恒温測试下不起边、脱胶、气泡,印刷内容必须通过蒸馏水、酒精、 异丙醇测试后能识别读出; 9、颜色参考: 产品型号LS108-B50#哑银咪纳不干胶(强胶)零件名称 零件图号 43*20 mm2SN003802-LS108-B-GB-01-背贴-A3 银底黑字(无边框) - 郭健波 2023-09-14 郭健波 2023-09-14 徐紫燕 2023-09-14 LS108-B-GB-01 电子秤 - 1:1 mm 产品名称 表面处理 共1张第1张 A/3版本 比例 材质 尺寸 印色 设计 审核 批准 单位 对应结构图纸 广东乐心医疗电子股份有限公司

Internal Photos

INTERTEK TESTING SERVICE Report No.: HK22071098 Equipment Photographs (Internal) INTERTEK TESTING SERVICE Report No.: HK22071098 Equipment Photographs (Internal) INTERTEK TESTING SERVICE Report No.: HK22071098 Equipment Photographs (Internal) INTERTEK TESTING SERVICE Report No.: HK22071098 Equipment Photographs (Internal)

RF Exposure Info

Analysis Report Report No.: HK22071098 The Equipment Under Test (EUT) is a Spare-it Scale with LoRa connectivity. Antenna Type: Internal integral antenna Maximum Antenna Gain: 2.9 dBi Conducted Power range: -10 dBm (Minimum) to +10 dBm (Maximum) According to the KDB 447498 D01 v06: Based on the Maximum allowed conducted power of production tolerance was +10 dBm, thus; So; Maximum Conducted Power = 10 mW. The SAR Exclusion Threshold Level: = 3.0 * (min. test separation distance, mm) / sqrt(freq. in GHz) = 3.0 * 5 / sqrt (0.928) mW = 15.6 mW Since the above conducted output power is well below the SAR Exclusion threshold level, so the EUT is considered to comply with SAR requirement without testing.

Test Report

TEST REPORT 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong SAR, China. Telephone: (852) 2173 8888 Facsimile: (852) 2785 5487 www.intertek.com Intertek’s standard Terms and Conditions can be obtained at our website http://www.intertek.com/terms/. The test report only allows to be revised within the retention period unless further standard or the requirement was noticed. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. © 2017 Intertek Page 1 of 43 Report No.: 22071098HKG-001 Application For Original Grant of 47 CFR Part 15 Certification Spare-it, Inc. 902-928MHz Transceiver FCC ID: 2BBSLLORASCALEV5HK Prepared and Checked by: Approved by: Leung Chun Ning, Peter Assistant Engineer Wong Cheuk Ho, Herbert Assistant Supervisor Date: August 28, 2023 TEST REPORT Spare-it, Inc. Intertek Report No: 22071098HKG-001 Page 2 of 44 GENERAL INFORMATION Grantee: Spare-it, Inc. Grantee Address: 444 Somerville Ave Somerville, Massachusetts 02143 USA FCC Specification Standard: FCC Part 15, October 1, 2021 Edition FCC ID: 2BBSLLORASCALEV5HK FCC Model(s): SPT-002 Type of EUT: Hybrid System Description of EUT: Smart Bin Waste Scale with LoRa Transmission (902-928MHz Transceiver) Sample Receipt Date: June 10, 2023 Date of Test: June 10, 2023 to August 20, 2023 Report Date: August 28, 2023 Environmental Conditions: Temperature: +10 to 40°C Humidity: 10 to 90% Conclusion: Test was conducted by client submitted sample. The submitted sample as received complied with the 47 CFR Part 15. TEST REPORT Spare-it, Inc. Intertek Report No: 22071098HKG-001 Page 3 of 44 TABLE OF CONTENTS EXHIBIT 1 TEST RESULTS SUMMARY & STATEMENT OF COMPLIANCE ................................ 4 1.1 Summary of Test Results ........................................................................................... 4 1.2 Statement of Compliance ......................................................................................... 4 EXHIBIT 2 GENERAL DESCRIPTION ..................................................................................... 5 2.1 Product Description .................................................................................................. 5 2.2 Test Methodology ..................................................................................................... 5 2.3 Test Facility ................................................................................................................ 5 2.4 Related Submittal(s) Grants ...................................................................................... 5 EXHIBIT 3 SYSTEM TEST CONFIGURATION ......................................................................... 6 3.1 Justification ............................................................................................................... 6 3.2 EUT Exercising Software............................................................................................ 7 3.3 Details of EUT and Description of Accessories ......................................................... 8 3.4 Measurement Uncertainty........................................................................................ 8 EXHIBIT 4 TEST RESULTS .................................................................................................... 9 4.1 Maximum Conducted (Peak) Output Power at Antenna Terminals ......................... 9 4.2 Minimum 6dB RF Bandwidth and Occupied Bandwidth ........................................ 12 4.3 Minimum Power Spectral Density .......................................................................... 16 4.4 Out of Band Conducted Emissions .......................................................................... 28 4.5 Radiated Emission Test Setup ................................................................................. 34 4.6 Field Strength Calculation ....................................................................................... 35 4.7 Transmitter Radiated Emissions in Restricted Bands and Spurious Emissions ...... 36 4.8 AC Power Line Conducted Emission ....................................................................... 41 EXHIBIT 5 EQUIPMENT LIST ............................................................................................. 42 TEST REPORT Spare-it, Inc. Intertek Report No: 22071098HKG-001 Page 4 of 44 EXHIBIT 1 TEST RESULTS SUMMARY & STATEMENT OF COMPLIANCE 1.1 Summary of Test Results Test Items FCC Part 15 Section RSS-210/ RSS-Gen # Results Details See Section Antenna Requirement 15.203 7.1.2# Pass 2.1 Maximum Conducted Output Power at Antenna Terminals 15.247(b)(3)&(4) 5.4(4) Pass 4.1 Minimum 6dB RF Bandwidth 15.247(a)(2) 5.2(1) Pass 4.2 99% Occupied Bandwidth -- 4.6.1# Pass 4.2 Maximum Power Spectral Density Reading 15.247(e) 5.2(2) Pass 4.3 Minimum Number of Hopping Frequencies 15.247(a)(1)(iii) 5.1(4) Pass 4.3 Minimum Hopping Channel Carrier Frequency Separation 15.247(a)(1) 5.1(2) Pass 4.4 Average Channel Occupancy Time 15.247(a)(1)(iii) 5.1(4) Pass 4.5 Out of Band Conducted Emission 15.247(d) 5.5 Pass 4.4 Radiated Emission in Restricted Bands and Spurious Emissions 15.247(d), 15.209 & 15.109 5.5 Pa…

Text truncated - open the document above for the full version.

Test Report

InSide TM GSM/DCS Datasheet Rev 1.4 2019-09-25 www.proant.se Proant AB Phone: +46 (0)90 40150 Gräddvägen 15A, 90620 Umeå, Sweden General information Antenna covering 868 MHz, GSM 900 (880 - 960 MHz) and GSM 1800, 1900 (1710 - 1990 MHz) for inside mounting on non-conductive surfaces such as plastic. InSide GSM/DCS is a ground plane independent antenna including coaxial cable with MHF, MHF4 or MMCX connector, supplied with adhesive. Applications IoT devices M2M-commmunications Telemetry Automated meter reading Alarms Antenna drawing. Above dimensions are given in millimeter. *Measured on Proant standard measurement fixture, see next page for more information. Technical data Frequency 868 - 960, 1710 - 1990 MHz Return loss* < -3.5 dB, 868 - 960 MHz < -3.6 dB, 1710 - 1990 MHz Efficiency* > -4.3 dB (37%), 868 - 960 MHz > -2.9 dB (51%), 1710 - 1990 MHz Gain* Max 2.9 dBi, 868 - 960 MHz Max 1.9 dBi, 1710 - 1990 MHz Dimensions 8.00 x 50.00 mm, thickness 0.80 mm RoHS status Compliant with EU directive 2011/65/EU and 2015/863 Mounting Adhesive tape Temperature -40 to +85⁰ C Datasheet Page | 2 Rev 1.4 2019-09-25 www.proant.se Proant AB Phone: +46 (0)90 40150 Gräddvägen 15A, 90620 Umeå, Sweden Electrical performance Measurement setup The antenna measurements were done on Proant’s standard measurement fixture - the antenna mounted in an ABS plastic box, 150x150x45 mm, connected to a PCB, 120x50 mm, with the cable fully extended. Return loss Total radiation efficiency Maximum radiation gain Datasheet Page | 3 Rev 1.4 2019-09-25 www.proant.se Proant AB Phone: +46 (0)90 40150 Gräddvägen 15A, 90620 Umeå, Sweden Radiation pattern, 900 MHz Antenna PCB Antenna PCB Antenna PCB Datasheet Page | 4 Rev 1.4 2019-09-25 www.proant.se Proant AB Phone: +46 (0)90 40150 Gräddvägen 15A, 90620 Umeå, Sweden Radiation pattern, 1710 MHz Antenna PCB Antenna PCB Antenna PCB Datasheet Page | 5 Rev 1.4 2019-09-25 www.proant.se Proant AB Phone: +46 (0)90 40150 Gräddvägen 15A, 90620 Umeå, Sweden Radiation pattern, 1990 MHz Antenna PCB Antenna PCB Antenna PCB Datasheet Page | 6 Rev 1.4 2019-09-25 www.proant.se Proant AB Phone: +46 (0)90 40150 Gräddvägen 15A, 90620 Umeå, Sweden Intended applications The antenna is optimized for operation in the GSM 900, 1800 and 1900 bands. Some of the supported bands are: Ordering information Part number Part name Details PRO-IS-212 InSide GSM/DCS (MHF) Antenna for GSM and DCS. 100 mm coaxial with MHF connector. PRO-IS-583 InSide GSM/DCS (MHF4) Antenna for GSM and DCS. 100 mm coaxial with MHF4 connector. PRO-IS-211 InSide GSM/DCS (MMCX) Antenna for GSM and DCS. 100 mm coaxial with MMCX connector. For information on sales, delivery terms and conditions and prices, please visit the Proant website (www.proant.se) for a complete list of distributors. Proant offers consultation with design-in of the InSide antennas. Proant have all necessary capabilities for antenna design including anechoic chamber and prototype workshop. Please send your requests to [email protected]. Disclaimer The information given in this application note shall in no event be regarded as a guarantee of conditions or characteristics. With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Proant AB hereby disclaims any and all warranties and liabilities of any kind, including without limitation, warranties of non-infringement of intellectual property rights of any third party. GSM/GPRS/EDGE GSM 900 (880 – 960 MHz) GSM 1800 (1710 – 1880 MHz) GSM 1900 (1850 – 1990 MHz) UMTS/LTE Band 2 (1850 – 1990 MHz) Band 3 (1710 – 1880 MHz) Band 8 (880 – 960 MHz) NB-IoT Band 8 (880 – 960 MHz) Sigfox 868 MHz LoRa EU 863 - 870 MHz US 902 - 928 MHz AU 915 - 928 MHz

Test Setup Photos

INTERTEK TESTING SERVICE Report No: HK22071098 Configuration Photographs Worst-Case Radiated Emissions (Front View) INTERTEK TESTING SERVICE Report No: HK22071098 Configuration Photographs Worst-Case Radiated Emissions (Rear View)

Contact Information

Applicant

Laurent Meunier
[email protected]9787619211Fax: N/A

Technical Contact

Intertek Testing Services Hong Kong Ltd.Kenneth Wong
[email protected]+85239126902

2/F., Garment Centre, · Hong Kong

Non-Technical Contact

Intertek Testing Services Hong Kong Ltd.Kenneth Wong
[email protected]+85239126902

Test Firm

Intertek Testing Services Hong Kong Ltd.Billy Chow
[email protected]85221738528Fax: 85227410521

Technical Specifications

#Rule PartsFrequency RangePower Output
115C923.2 MHz - 924.6 MHz5.50 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the operating requirements for satisfying RF exposure compliance.

Other Applications from Spare-it, Inc.

Smart Bin Waste Scale with LoRa Transmission - FCC ID 2BBSLLORASCALEV5 - Spare-it, Inc.
2BBSLLORASCALEV5

Smart Bin Waste Scale with LoRa Transmission

Jul 19, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter