INSTALLATION INSTRUCTIONS: 1.The socket is suitable for manufa cturers such as bedside cabinet, sofa , working table, desk, etc. 2.The manufa cturer buys the product and inserts it into the mounting hole. The mounting procedure: make a hole in the countertop-insert it into the fu rniture row-s crewthe panel in place and carefu lly check for looseness. 3.Detailed installation drawings are shown in the attached installation manual. PRECAUTIONS: 1.Determine the required according to the device position, measure the size of the bottomof the fu rniture rowinsert, the table aft er the hole embedded, with screws to the panel In stallation Manual: The product is installedon a non-horizontal table 1.Mountingholesize 160 2. In sert the Furniture Rowinto the desktop opening 3. Lock the panel with a screwdriver 4. Plug in the power supply and complete the installation. 5. Charging instructions: with wireless charging function of mobile phone use, mobile phone on theback of the wireless sensor above. Cell phones Wireless charging position FCC Warning This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Refer to FCC Part 18.213(c) and KDB 784748 Anner A section A.5: (a)Max. Electric Field Emissions: 6.85V/m; Max. Magnetic Field Emissions: 0.51A/m (b)The maintenance of the system is the responsibility of the manufacturer. (c)To prevent interference, the product should be as far away from devices operating at the same frequency as possible. RF exposure considerations (d) This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body. (e)
Guangdong Zhangong ltlcctric 1 、 echnology Co., l儿ti. .. ?.��1. f!��_1: ,.�9j_l�J�!�SJ?. 名�(f�1£�1 :9.<?�,.� 气�)�! r. � I .�f-? 令 i吼 1 :i_ 9 鬻h .f:9卧丹·!��!fY.t9Htl_ ll l;9Q�1l\�'»royJn90? �;hi.Oh Date: 2023-07-08 FEDERAL COMMUNICATIONS COMMISSION AUTHORIZATION AND EVALUATION DIVISI ON 7435 OAKLAND MILLS ROAD COLUMBIA, MD 21046 SUBJECT: FCC Application for FCC ID: 2BBUs .. zG 晒 JJM1 21 5 A •• 一..岁`. . Confidentiality Request To whom it may concern, Pursuant to the provisions of the Commission's ru 啦 Title 47 Sections §0.457 and§0.459, we aro roquostln(1 o, Commiss i on to withhold the following attachment(s) as confidential documents from public disclosure lndof\nl呤 因 Block Diagram O Tune-Up Information 因 Operational Description D Security Information 因S chematics O Software Defined Radio (SOR) Information D Parts List The above materials contain trade secrets and proprietary Information not customarily released to tt,o p1..1bllc. Tho public disclosure of these materials may be harmful to the applicant and provide unjustified boneflts to Its competitors. In additional to above mentioned documents, In order to comply with the marketing regulations In Title 47 CFR § 2 .8 0 3 and the impo rtation rules In Title 47 CFR §2.1204, while ensurin g that business sensiti v e lnformo t ,on remains confidential until the actual marketing of newly authorized devices, we request Sh ort Term Conf1dontloli t y of the following attachment(s); D External Photos O Internal Photos 口 Test Setup Photos 0 User Manual O For 45 days, pursuant to Public Notice DA 04-170 5. or D For 180 days pursuant to KDB 726920 D01. The applicant understands that pursuant to Section 0.457 of the Rules, disclos1..ire of U1ls nppllcul\on nnd u\l accompanying documentation will not be made before the date of the Grant for this oppllcn tlon. Sincerely, \才: r,-\ 石 !l'">! t "'\ 1 \ \从 ,·. , �:, / \, 五 少 } 疗 �! '· , 1 1[ [Xuekal Zhsn, pen. e ra/ mf)nager] - 1 加如 ` 、 五趴I .,.:.:' 产 i ,1 n�! 心,, n , rt, 、
Reference No.: WTN22X12256062W001/002 Page 2 of 10 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn EXHIBIT 2 - EUT EXTERNAL PHOTOGRAPHS EUT View 1 EUT View 2 Reference No.: WTN22X12256062W001/002 Page 3 of 10 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn EUT View 3 EUT View 4 Reference No.: WTN22X12256062W001/002 Page 4 of 10 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn EUT View 5 EUT View 6
Reference No.: WTN22X12256062W001/002 Page 1 of 10 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn ANNEX EXHIBIT 1 - PRODUCT LABELING Proposed FCC ID Label Format FCC ID: 2BBU5-ZG-JJM1215A Specifications: The label shall be securely affixed to a permanently attached part of the device, in a location where it is visible or easily accessible to the user, and shall not be readily detachable. The label shall be sufficiently durable to remain fully legible and intact on the device in all normal conditions of use throughout the device’s expected lifetime. Proposed Label Location on EUT FCC ID Label Location
Reference No.: WTN22X12256062W001/002 Page 5 of 10 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn EXHIBIT 3 - EUT INTERNAL PHOTOGRAPHS EUT Housing and Board View 1 Solder Board-Component View 1 Reference No.: WTN22X12256062W001/002 Page 6 of 10 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Solder Board-Component View 2 Solder Board-Component View 3 Reference No.: WTN22X12256062W001/002 Page 7 of 10 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Solder Board-Component View 4 Solder Board-Component View 5 Reference No.: WTN22X12256062W001/002 Page 8 of 10 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Solder Board-Component View 6 Antenna View
Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 1 of 13 TEST REPORT Reference No. .................... : WTN22X12256062W002 FCC ID ................................ : 2BBU5-ZG-JJM1215A Applicant ........................... : Guangdong Zhangong Electric Technology Co., Ltd. Address.............................. : 7th Floor,Building29,Zhifugarden,ShundeDistrict, FoshanCity, GuangdongProvince, China Manufacturer ..................... : The same as Applicant Address.............................. : The same as Applicant Product Name ................... : Furniture socket Model No... ......................... : ZG-JJM/12/15A Standards .......................... : KDB 680106 D01 V03 Date of Receipt sample .... : 2022-12-20 Date of Test........................ : 2022-12-20 to 2023-05-23 Date of Issue ..................... : 2023-05-23 Test Report Form No. ....... : WTX_KDB 680106_D01_V03W Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Email: [email protected] Tested by: Approved by: Mike Shi Silin Chen Reference No.: WTN22X12256062W002 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 2 of 13 TABLE OF CONTENTS 1. GENERAL INFORMATION ........................................................................................................................ 4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .................................................................. 4 1.2 AUXILIARY EQUIPMENT LIST AND DETAILS ................................................................................................ 5 1.3 TEST EQUIPMENT LIST AND DETAILS ........................................................................................................ 6 2. RF EXPOSURE TEST REPORT ................................................................................................................ 7 2.1 STANDARD APPLICABLE ........................................................................................................................... 7 2.2 TEST CONDITIONS ................................................................................................................................... 7 2.3 TEST PROCEDURE .................................................................................................................................. 8 2.4 TEST RESULT.......................................................................................................................................... 9 2.5 MEASUREMENT UNCERTAINTY ............................................................................................................... 11 2.6 TEST PHOTOS ....................................................................................................................................... 12 APPENDIX PHOTOGRAPHS ...................................................................................................................... 13 Reference No.: WTN22X12256062W002 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 3 of 13 Report version Version No. Date of issue Description Rev.00 2023-05-23 Original / / / Reference No.: WTN22X12256062W002 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 4 of 13 1. GENERAL INFORMATION 1.1 Product Description for Equipment Under Test (EUT) General Description of EUT Product Name: Furniture socket Trade Name: / Model No.: ZG-JJM/12/15A Adding Model: ZG-PDU00/10A/15A, ZG-PDUG1/10A/15A, ZG-PDUG1/10A/15A, ZG-PDUC3/10A/15A, ZG-PDUC9/10A/15A, ZG-PDUA/10A/15A, ZG-PDUY/10A/15A, ZG-PDUM/12A/15A, ZG-JJ/12A/15A, ZG-HG/12A/15A, ZG-ZJ/12A/15A, ZG-SJ/12A/15A, ZG-DQ/12A/15A, ZG-PC/12A/15A, ZG-PDU JO0/12A/15A Battery Capacity / Note: The test data is gathered from a production sample, provided by the manufacturer. The appearance of others models listed in the report is different from main-test model ZG-JJM/12/15A, but the circuit and the electronic construction do not change, declared by the manufacturer. Technical Characteristics of EUT Frequency Range: 112-205kHz Modulation Type: ASK Antenna Type: Coil Antenna Wireless output: 15W(MAX) Reference No.: WTN22X12256062W002 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 5 of 13 1.2 Auxiliary Equipment List and Details EUT Cable List and Details Cable Description Length (M) Shielded/Unshielded With Core/Without Core AC CABLE 1.9 Unshielded Without Ferrite Auxiliary Equipment List and Details Description Manufacturer Model Serial Number Wireless charging tester / YBZ / Special Cable List and Details Cable Description Length (M) Shielded/Unshielded With Core/Without Core / / / / Reference No.: WTN22X12256062W002 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 6 of 13 1.3 Test Equipment List and Details Description Manufacturer Model Serial No. Cal Date Due Date ELECTRIC AND MAGNETIC FIELD ANALYZER Narda EHP-200AC 180ZX10226 2021-05-20 2024-05-19 Note: The deviation response is 0.8dB. Reference No.: WTN22X12256062W002 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 7 of 13 2. RF Exposure Test Report 2.1 Standard Applicable According to§1.1310 system operating under the provisions of this section shall be operating in a manner that the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure. 2.2 Test Conditions Test Mode Description Remark Power Supply Mode TM1 Wireless charging Wireless output(5W) / TM2 Wireless ch…
Text truncated - open the document above for the full version.
unit: mm
Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 1 of 36 TEST REPORT Reference No. .................... : WTN22X12256062W001 FCC ID ................................ : 2BBU5-ZG-JJM1215A Applicant ........................... : Guangdong Zhangong Electric Technology Co., Ltd. Address.............................. : 7th Floor,Building29,Zhifugarden,ShundeDistrict, FoshanCity, GuangdongProvince, China Manufacturer ..................... : The same as Applicant Address.............................. : The same as Applicant Product Name ................... : Furniture socket Model No... ......................... : ZG-JJM/12/15A Standards .......................... : FCC Part 15C Date of Receipt sample .... : 2022-12-20 Date of Test........................ : 2022-12-20 to 2023-05-23 Date of Issue ..................... : 2023-05-23 Test Report Form No. ....... : WTX_Part 15CW Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Email: [email protected] Tested by: Approved by: Mike Shi Silin Chen Reference No.: WTN22X12256062W001 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 2 of 36 ABLE OF CONTENTS 1. GENERAL INFORMATION ...................................................................................................................................4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ...............................................................................4 1.2 TEST STANDARDS ...................................................................................................................................................5 1.3 TEST METHODOLOGY .............................................................................................................................................5 1.4 TEST FACILITY .......................................................................................................................................................5 1.5 EUT SETUP AND OPERATION MODE ......................................................................................................................6 1.6 MEASUREMENT UNCERTAINTY ..............................................................................................................................7 1.7 TEST EQUIPMENT LIST AND DETAILS .....................................................................................................................8 2. SUMMARY OF TEST RESULTS ......................................................................................................................... 12 3. RF EXPOSURE ....................................................................................................................................................... 13 3.1 STANDARD APPLICABLE ....................................................................................................................................... 13 3.2 TEST RESULT........................................................................................................................................................ 13 4. ANTENNA REQUIREMENT ................................................................................................................................ 14 4.1 STANDARD APPLICABLE ....................................................................................................................................... 14 4.2 EVALUATION INFORMATION................................................................................................................................. 14 5. CONDUCTED EMISSIONS .................................................................................................................................. 15 5.1 TEST PROCEDURE ................................................................................................................................................. 15 5.2 BASIC TEST SETUP BLOCK DIAGRAM ................................................................................................................... 15 5.3 ENVIRONMENTAL CONDITIONS ............................................................................................................................ 15 5.4 TEST RECEIVER SETUP ......................................................................................................................................... 16 5.5 SUMMARY OF TEST RESULTS/PLOTS .................................................................................................................... 16 6. FIELD STRENGTH OF SPURIOUS EMISSIONS ............................................................................................. 22 6.1 STANDARD APPLICABLE ....................................................................................................................................... 22 6.2 TEST PROCEDURE ................................................................................................................................................. 22 6.3 CORRECTED AMPLITUDE & MARGIN CALCULATION ............................................................................................ 23 6.4 ENVIRONMENTAL CONDITIONS ............................................................................................................................ 24 6. REFERENCE MEASUREMENT AT OPEN FIELD SITE ................................................................................................... 24 6.5 SUMMARY OF TEST RESULTS/PLOTS .........................…
Text truncated - open the document above for the full version.
Reference No.: WTN22X12256062W001/002 Page 9 of 10 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn EXHIBIT 4 - TEST SETUP PHOTOGRAPHS Conducted Emission Test Setup Radiation Emission Test Setup (Below 30MHz) Reference No.: WTN22X12256062W001/002 Page 10 of 10 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Radiation Emission Test Setup (30MHz to 1GHz) ***** END OF REPORT *****
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.112 MHz - 0.205 MHz | - |