FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Mifree Technology Co.,ltd/
  3. 2BBV5-YH10

2BBV5-YH10smart watchs

Mifree Technology Co.,ltd
smart watchs - FCC ID 2BBV5-YH10 - Mifree Technology Co.,ltd
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jul 15, 2023
Application Purpose
Original Equipment
Date of Application
Jul 15, 2023
Equipment Note
smart watchs
Frequency Range
2402.00000000 - 2480.00000000
Company
Mifree Technology Co.,ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Thank you for choosing our smartwatch. You can read this manual tofullyunderstandtheuseofthedevice,thisdeviceismainly through Bluetoothconnectionto themobilephoneforadaptation,providesa varietyofpractical functionsandservices tofacilitateyouroperation ofthemobilephone,and developedalotoffunctionsforhumanmo--vement and health. The Company reserves the right to make chang--es to the contents of this manual without prior notice without prior notice.Thisproduct does not support rain, hand washing, swimming wear, hotshowerorsaunacan notbeworn,can notprevent watervapor.Ifthewatch isdamaged bywaterinlet duetonon-useaccordingtotheinstructions,thecompanydoesnotmakea freewarranty. Smart watches 1.91" , resolution of 240x296 2.5D full touch screen Waterproof rating IP67 Support Bluetooth 5.3 Battery capacity 2 1 0mAh Basic parametersOperating instructions Switch button: long press to turn on, Short press to enter/exit the menu, double-click to switch menu styleRotate encoder, switch dial and slide menu Left Stroke: Shortcut Function Upward Stroke: Status Bar Swipe Right: Split Screen Underline: Messag e Notification User Manual X1, Smart Watch X1, Silicon Strap X1, Charging lineX1. Charging instructions Using magnetic charging mode, support computer USB or mobile Please use a charger that meets international safety standards for charging,otherchargers cancharge,theremaybeproblemssuch asslowcharging,heating,etc.,pleaseusewithcaution. Themagnetic suction charginghead containsamagnetinside, whichprohibitslong-termcontact withhightemperatures,and demagnetization mayoccur. Pair the connection phone and install, two ways; the right two-dimensional code through the mobile phone browser, or scan it with WeChat, After opening the interfa- and then use your phoneThe browser opens the download; time or recovers After the factory starts the watch, before entering the main int- -erface, The QR code will be displayed and scanned through a mobilebrowserorvia WeChatScan,opentheinterface,and thenusethemobilebrowsertoopenthedownload; The mobile phone system requires Android 5.1 (inclusive) or above, The permissions during the installation process require all the optional consent,otherwiseitmayaffecttheuseofthefunction. Some Android mobile phone systems need to open the mobile phone GPS tosearchfortheBluetooth nameof thewatch. the Bluetooth address or Bluetooth name of the watch, select and connect. Sleep monitoring: It will record your sleep duration and quality from 9 o'clock everynightto9o'clock thenextmorningtohelpyoubetteradjustyourwork andresttimeand improvesleepquality. Phone dialing: connect to call Bluetooth, dial from the watch,you can makeacallon thewatchside; therearecontactsand call recordsin thedial interface,and frequentlyused contactsneed toaddsettingsin theAPP. app on the mobile phone to query the third-party program Heart rate monitoring: Wear a watch, the best place to wear it is thewristboneabovethearm,you canmonitorthereal-timeheart ratevalue, thenormal valueoftheaverageperson is60-90beats /min.Clickstartontheheartrateinterface,thevaluewillbe measuredafterabout 20-30seconds,andthedetectionwillstopafter60 seconds,and thevaluewillbetheheart ratevaluewhen thedetection was stopped. pressure value will be displayed within one minute.Blood oxygen: enter the blood oxygen function, press start to enter thetest, the normalblood oxygensaturationisabout94-99%.exercise Indoor exercise: A variety of indoor exercises can monitor your dexerciseata moreaccurately.Atthesametime, theheartrate monitoring will beturned on,andtheoptionofstoppingorpausing can besetontheexercisemodeinterface. Bluetooth camera: You need to enter the camera function in the APP, shakethewatch backandforthseveraltimestoremotelycontrol thecamera. Bluetooth music: After connecting and calling Bluetooth, you can playandcontrol themusicinthephone. Weather: After connecting the mobile phone to synchronize data, you canchecktheweatheroftheday. Settings: Carry out various local settings of this machine,including brightness, rest screen duration, hand-up on screen, do not disturb mode, sound and vibration, language switching,mobile phone QR code connection, watch password, shutdown,factory reset, this machineInformationetc. Warranty instructions 1. When this product is in normal use, if there is a product quality problemcausedbymanufacturing,material, design andotherreasons,fromthedateofpurchase,themotherboard hasafreewarrantywithin oneyear,thebattery,chargerwarrantyforhalfa year.2. Due to the failure caused by the user's personal, the free Warrantyisnotprovided,asfollows:malfunctions. If the WeChat desktop version is online at the same saving whitelist to avoid being turned off by the phone when the battery islow. 3) All man-made damage or due to the fault of a third party,misuse ( suchas:hostwateringress,external forcecracking,scratchdamageofperipheralcomponents,etc.),is not cove-redbythewarranty.3. When requesting free warranty, please provide a warranty cardwith thedateofpurchaseand theseal oftheplaceofpurchase. to the following two conditions: (1) This device may not cause harmful interference, and(2) thisdevicemustacceptanyinterferencereceived, includinginterferencethat maycauseundesired operation. responsible for compliance could void the user's authority to operate theequipment. This equipment has been tested and found to comply with the These limits are designed to provide reasonable protection against harmful interferenceinaresidential installation.Thisequipment generatesusesand canradiateradiofrequency energy and, ifnot installedandused inaccordancewiththeinstructions,may cause harmful interferencetoradiocommunications.However, thereisno guaranteethatinterferencewill notoccurin aparticularinstallation. Ifthisequipmentdoes causeharmful interferencetoradioortelevisionreception,which canbedetermined byturning theequipmentoffand on,theuserisencouraged totrytocorrecttheinterferencebyoneor moreofthefollowing measures: -Reorient or relocate th…

Text truncated - open the document above for the full version.

Attestation Statements

(MIFREE TECHNOLOGY CO., LTD) (2023.07.07) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2BBV5-YH10) [MIFREE TECHNOLOGY CO., LTD] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) Zhang yajun (MIFREE TECHNOLOGY CO., LTD) (2023.07.07) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2BBV5-YH10) [MIFREE TECHNOLOGY CO., LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Zhang yajun

Cover Letter(s)

Mifree Technology Co., ltd 2023.7.7 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: CONFIDENTIALITY REQUEST FOR EUT NAME: smart watchs Trademark: N/A MODEL : YH10 YH11, OA88, OA89, T93, T95, T97, T98, HX12, ZERO PRO, HX16, HX20, LX08, HX08, H8, FR98, K8, K9, OR4 PRO, HX9 PRO FCC ID: 2BBV5-YH10 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - Block Diagram - Schematics - Operational Description required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Sincerely, Client’s signature: Client’s name / title : Weixin MEi/Manager Contact information / address: 103-104, First floor bulding 15, F518 fashion creative park, Baoyuan Road, Xixang, Shenzhen China

Cover Letter(s)

Mifree Technology Co., ltd 2023.7.7 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Shenzhen BCTC Testing Co., Ltd to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Client’s signature: Client’s name / title : Weixin MEi/Manager Contact information / address: 103-104, First floor bulding 15, F518 fashion creative park, Baoyuan Road, Xixang, Shenzhen China

Cover Letter(s)

Mifree Technology Co., ltd Model Difference 2023/7/7 EUT NAME: smart watchs FCC ID: 2BBV5-YH10 MODEL : YH10 YH11, OA88, OA89, T93, T95, T97, T98, HX12, ZERO PRO, HX16, HX20, LX08, HX08, H8, FR98, K8, K9, OR4 PRO, HX9 PRO All the model are the same circuit and RF module, except model names. Regards Sincerely Client’s signature Client’s signature: Client’s name / title : Weixin MEi/Manager Contact information / address: 103-104, First floor bulding 15, F518 fashion creative park, Baoyuan Road, Xixang, Shenzhen China lang street, Longhua District, Shenzhen, China

External Photos

External Photos

ID Label/Location Info

Label & label location 10mm*5mm FCC ID:2BBV5-YH10

Internal Photos

Internal Photos Antenna

RF Exposure Info

RF EXPOSURE EVALUATION METHOD FCC ID: 2BBV5-YH10 Applicable standard: In accordance with FCC 47 CFR part 2 (2.1093) this device has been defined as a portable device which is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable devices must be evaluated using the specified in FCC 47 CFR part 2 (2.1093) and ANSI/IEEEC95.1-1992. and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528-2003. Per FCC KDB 447498 D01 v06, the 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances s 50 mm are determined by: SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. BT GFSK 2402 0.145 21 GFSK 2441 0.131 21 GFSK 2480 -0.355 21 π/ 4 DQPSK 2402 1.028 21 π/ 4 DQPSK 2441 0.976 21 π/ 4 DQPSK 2480 0.486 21 max possible output power (PK,conducted):2±1dBm 0dBi logarithmic terms convert to numeric result is nearly 1.000 3dBm=2.00mW 2402MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 2.00/5*√2.402=0.62≤3.0 2441MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 2.00/5*√2.441=0.62≤3.0 2480MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 2.00/5*√2.48=0.62≤3.0 BLE GFSK 2402 4.57 30 GFSK 2440 4.97 30 GFSK 2480 4.7 30 π/ 4 DQPSK 2402 4.58 30 π/ 4 DQPSK 2440 5.01 30 π/ 4 DQPSK 2480 4.73 30 max possible output power (PK,conducted):6±1dBm 0dBi logarithmic terms convert to numeric result is nearly 1.000 7dBm=5.01mW 2402MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 5.01/5*√2.402=1.55≤3.0 2440MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 5.01/5*√2.44=1.57≤3.0 2480MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 5.01/5*√2.48=1.58≤3.0 Conclusion: 1.[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] * [√f(GHz)] < 3.0. 2. SAR Test Exclusion Thresholds is 3.0 for separation distance 5mm. Therefore, SAR test is not required.

Test Report

深圳市一线通线缆有限公司 Shenzhen first line cable Co., LTD 地址:深圳市宝安区沙井街道万丰98工业城21栋 Add: 21 Building, Wanfeng 98 Industrial City, Shajing Street, Baoan District, Shenzhen 天线规格承认书 Antenna Specification for Approval 客户名称 CustomerName:深圳市慧芯科技有限公司 产品名称: ProductName:2.4G天线 全长25mm红色 客户型号: ProductName: 产品料号: Part NO.:C10- 35-2.5 制 表 : WriteBy :庄杰彬 日 期: IssuedDate:2023-06-26 客 户: 工程R&D Dept采购Business Dept承认Approved By 一线通 研发 R&D Dept 工程Engineer Dept 审核 Approval 庄彩虹庄杰彬庄杰彬 ProductSpecification A.ElectricalCharacteristics Frequency2400MHz ~2500MHzVSWR<3.0 Efficiency>30% Impedance50 OhmPolarization LineGain 0DBi B.Material&MechanicalCharacteristics MaterialofRadiatorCu CableType1.019P红 ConnectorType:NO Dimension C.Environmental OperationTemperature-30°C~+80 °CStorageTemperature-30°C~+ 85°C TestEquipment&Conditions 1.NetworkAnalyzers: Agilent8753D5071C 2.CommunicationsTestSet: AgilentE5525C 3.3DChamberTestSystem Effiency&Gain Effiency&Gain 2.40-0.00 2.440-0.11 2.48-0.13 RadiationPattern:

Test Report

No.:BCTC/RF-EMC-007 Page: 1 of 60 Edition:B.0 TEST REPORT Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC2306992137-1E Applicant: Mifree Technology Co., ltd Product Name: smart watchs Model/Type reference: YH10 Tested Date: 2023-06-26 to 2023-07-14 Issued Date: 2023-07-14 Report No.: BCTC2306992137-1E No.:BCTC/RF-EMC-007 Page: 2 of 60 Edition:B.0 FCC ID:2BBV5-YH10 The test report is effective only with both signature and specialized stamp.This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen BCTC Testing Co., Ltd, this report can’t be reproduced except in full.The tested sample(s) and the sample information are provided by the client. Product Name: smart watchs Trademark: N/A Model/Type reference: YH10 YH11, OA88, OA89, T93, T95, T97, T98, HX12, ZERO PRO, HX16, HX20, LX08, HX08, H8, FR98, K8, K9, OR4 PRO, HX9 PRO Prepared For: Mifree Technology Co., ltd Address: 103-104, First floor bulding 15, F518 fashion creative park, Baoyuan Road, Xixang, Shenzhen China Manufacturer: Mifree Technology Co., ltd Address: 103-104, First floor bulding 15, F518 fashion creative park, Baoyuan Road, Xixang, Shenzhen China Prepared By: Shenzhen BCTC Testing Co., Ltd. Address: 1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: 2023-06-26 Sample tested Date: 2023-06-26 to 2023-07-14 Issue Date: 2023-07-14 Report No.: BCTC2306992137-1E Test Standards: FCC Part15.247 ANSI C63.10-2013 Test Results: PASS Remark: This is Bluetooth Classic radio test report. Tested by: Approved by: Kelsey Tan/ Project Handler Zero Zhou/Reviewer Report No.: BCTC2306992137-1E No.:BCTC/RF-EMC-007 Page: 3 of 60 Edition:B.0 Table Of Content Test Report Declaration Page 1. Version .................................................................................................................. 5 2. Test Summary ....................................................................................................... 6 3. Measurement Uncertainty ..................................................................................... 7 4. Product Information And Test Setup ..................................................................... 8 4.1 Product Information ............................................................................................... 8 4.2 Test Setup Configuration ...................................................................................... 8 4.3 Support Equipment ............................................................................................... 9 4.4 Channel List .......................................................................................................... 9 4.5 Test Mode ........................................................................................................... 10 4.6 Table Of Parameters Of Text Software Setting ................................................... 10 5. Test Facility And Test Instrument Used ............................................................... 11 5.1 Test Facility ......................................................................................................... 11 5.2 Test Instrument Used .......................................................................................... 11 6. Conducted Emissions .......................................................................................... 13 6.1 Block Diagram Of Test Setup .............................................................................. 13 6.2 Limit .................................................................................................................... 13 6.3 Test procedure .................................................................................................... 13 6.4 EUT operating Conditions ................................................................................... 13 6.5 Test Result .......................................................................................................... 14 7. Radiated Emissions ............................................................................................. 16 7.1 Block Diagram Of Test Setup .............................................................................. 16 7.2 Limit .................................................................................................................... 17 7.3 Test procedure .................................................................................................... 18 7.4 EUT operating Conditions ................................................................................... 19 7.5 Test Result .......................................................................................................... 20 8. Radiated Band Emission Measurement And Restricted Bands Of Operation ..... 24 8.1 Block Diagram Of Test Setup .............................................................................. 24 8.2 Limit .................................................................................................................... 24 8.3 Test procedure .................................................................................................... 25 8.4 EUT operating Conditions ................................................................................... 25 8.5 Test Result .......................................................................................................... 26 9. Spurious RF Conducted Emissions ..................................................................... 27 9.1 Block Diagram Of Test Setup .............................................................................. 27 9.2 Limit .................................................................................................................... 27 9.3 Test procedure .................................................................................................... 27 9.4 Test Result …

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: BCTC2306992137-1E No.:BCTC/RF-EMC-007 Page: 58 of 60 Edition:B.0 17. EUT Test Setup Photographs Conducted Emission Radiated Measurement Photos Report No.: BCTC2306992137-1E No.:BCTC/RF-EMC-007 Page: 59 of 60 Edition:B.0

Contact Information

Applicant

Weixin MEi(Manager)
[email protected]13510001288Fax: 13510001288

Test Firm

Shenzhen BCTC Testing Co., Ltd.Sally He
[email protected]15999690624

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.27 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.