FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Jinshi Technology Co. , Ltd/
  3. 2BBYL-H9

2BBYL-H9projector

Shenzhen Jinshi Technology Co. , Ltd
projector - FCC ID 2BBYL-H9 - Shenzhen Jinshi Technology Co. , Ltd
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jul 16, 2023
Application Purpose
Original Equipment
Date of Application
Jul 16, 2023
Equipment Note
projector
Frequency Range
5745.00000000 - 5825.00000000
Company
Shenzhen Jinshi Technology Co. , Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.

Attestation Statements

Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: Shenzhen Jinshi Technology Co. , Ltd Address: Room701, building 2000089, Shangwai industrial zone, Zhangkengjing community, Guanhu Street, Longhua district, Shenzhen, China Phone: +86-13590790364 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. FCC ID: 2BA3C-H89 If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-07-13 Name / Title: Defeng Zeng / QA Manager Company: Shenzhen Jinshi Technology Co. , Ltd Address: Room701, building 2000089, Shangwai industrial zone, Zhangkengjing community, Guanhu Street, Longhua district, Shenzhen, China Phone: +86-13590790364 E-Mail: [email protected]

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BBYL-H9 H9, H1, H2, H3, H4, H5, H6, H7, H8, A3 We, applicant Company Name: Shenzhen Jinshi Technology Co. , Ltd Address: Room701, building 2000089, Shangwai industrial zone, Zhangkengjing community, Guanhu Street, Longhua district, Shenzhen, China Phone: +86-13590790364 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-07-13 Name / Title: Defeng Zeng / QA Manager Company: Shenzhen Jinshi Technology Co. , Ltd Address: Room701, building 2000089, Shangwai industrial zone, Zhangkengjing community, Guanhu Street, Longhua district, Shenzhen, China Phone: +86-13590790364 E-Mail: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BBYL-H9 H9, H1, H2, H3, H4, H5, H6, H7, H8, A3 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-07-13 Name / Title: Defeng Zeng / QA Manager Company: Shenzhen Jinshi Technology Co. , Ltd Address: Room701, building 2000089, Shangwai industrial zone, Zhangkengjing community, Guanhu Street, Longhua district, Shenzhen, China Phone: +86-13590790364 E-Mail: [email protected]

Cover Letter(s)

Shenzhen Jinshi Technology Co. , Ltd Room701, building 2000089, Shangwai industrial zone, Zhangkengjing community, Guanhu Street, Longhua district, Shenzhen, China Date: July 13, 2023 FCC ID: 2BBYL-H9 Model Number: H9, H1, H2, H3, H4, H5, H6, H7, H8, A3 To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Shenzhen Jinshi Technology Co. , Ltd hereby declare that our product (projector) Model Number: H9, H1, H2, H3, H4, H5, H6, H7, H8, A3 board, Schematic, Hardware version, Software version, structure and internal photos are same, named differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name / Title: Defeng Zeng / QA Manager Company: Shenzhen Jinshi Technology Co. , Ltd Address: Room701, building 2000089, Shangwai industrial zone, Zhangkengjing community, Guanhu Street, Longhua district, Shenzhen, China Phone: +86-13590790364 E-Mail: [email protected]

External Photos

FCCID: 2BBYL-H9 Fig. 1 Fig. 2 FCCID: 2BBYL-H9 Fig. 3 Fig. 4 FCCID: 2BBYL-H9 Fig. 5 Fig. 6 FCCID: 2BBYL-H9 Fig. 7

ID Label/Location Info

_____________________________________________________________________________________________________ LABEL AND LOCATION (Size: L7.0cm x3.5cm) Label Location

Internal Photos

FCCID: 2BBYL-H9 Fig. 1 Fig. 2 FCCID: 2BBYL-H9 Fig. 3 Fig. 4 WLAN Antenna BT Antenna FCCID: 2BBYL-H9 Fig. 5 Fig. 6 FCCID: 2BBYL-H9 Fig. 7 Fig. 8 FCCID: 2BBYL-H9 Fig. 9 Fig. 10 FCCID: 2BBYL-H9 Fig. 11 Fig. 12 FCCID: 2BBYL-H9 Fig. 13

RF Exposure Info

Shenzhen Global Test Service Co.,Ltd. No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road, Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong RF Exposure evaluation Report Reference No...................... : FCC ID. ............................................ : GTS20230523010-1-15 2BBYL-H9 Compiled by ( position+printed name+signature) . : File administrators Peter Xiao Supervised by ( position+printed name+signature) . : Test Engineer Jenny Zeng Approved by ( position+printed name+signature) . : Manager Jason Hu Date of issue .................................... : Jun.20, 2023 Representative Laboratory Name . : Shenzhen Global Test Service Co.,Ltd. Address ............................................ : No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road, Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong Applicant’s name ............................ : Shenzhen Jinshi Technology Co. , Ltd Address ............................................ : Room701, building 2000089, Shangwai industrial zone, Zhangkengjing community, Guanhu Street, Longhua district, Shenzhen, China Test specification ........................... : Standard ........................................... : 47CFR §1.1310 Basis and purpose 47CFR §2.1091 Radiofrequency radiation exposure evaluation: mobile devices KDB447498 D01 General RF Exposure Guidance v06 TRF Originator .................................. : Shenzhen Global Test Service Co.,Ltd. Master TRF ...................................... : Dated 2014-12 Shenzhen Global Test Service Co.,Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Global Test Service Co.,Ltd. is acknowledged as copyright owner and source of the material. Shenzhen Global Test Service Co.,Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : projector Trade Mark ....................................... : N/A Manufacturer .................................... : Shenzhen Jinshi Technology Co. , Ltd Model/Type reference ...................... : H9 Listed Models .................................. : H1, H2, H3, H4, H5, H6, H7, H8, A3 Hardware Version ............................ : N/A Software Version .............................. : N/A Rating ............................................... : AC 100-240V, 50/60Hz Result ............................................... : PASS Report No.: GTS20230523010-1-15 Page 2 of 14 T E S T R E P O R T Test Report No. : GTS20230523010-1-15 Jun.20, 2023 ______________________________________________________________________________________________ Date of issue Equipment under Test : projector Model /Type : H9 Listed model : H1, H2, H3, H4, H5, H6, H7, H8, A3 Applicant : Shenzhen Jinshi Technology Co. , Ltd Address : Room701, building 2000089, Shangwai industrial zone, Zhangkengjing community, Guanhu Street, Longhua district, Shenzhen, China Manufacturer : Shenzhen Jinshi Technology Co. , Ltd Address : Room701, building 2000089, Shangwai industrial zone, Zhangkengjing community, Guanhu Street, Longhua district, Shenzhen, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: GTS20230523010-1-15 Page 3 of 14 Contents 1. SUMMARY ................................................................................................................................................................. 4 1.1 EUT CONFIGURATION ........................................................................................................................................................ 4 1.2 PRODUCT DESCRIPTION ..................................................................................................................................................... 4 2. TEST ENVIRONMENT ................................................................................................................................................. 5 2.1 ADDRESS OF THE TEST LABORATORY ..................................................................................................................................... 5 2.2 TEST FACILITY .................................................................................................................................................................. 5 2.3 ENVIRONMENTAL CONDITIONS ............................................................................................................................................ 5 2.4 STATEMENT OF THE MEASUREMENT UNCERTAINTY .................................................................................................................. 5 3. METHOD OF MEASUREMENT .................................................................................................................................... 6 3.1 APPLICABLE STANDARD ...................................................................................................................................................... 6 3.2 REQUIREMENT ................................................................................................................................................................. 6 3.3 LIMIT ............................................................................................................................................................................. 6 3.4 MPE CALCULATION METHOD ............................................................................................................................................. 7 3.5 ANTENNA INFORMATION ...................................................................................…

Text truncated - open the document above for the full version.

Test Report

深圳市千目通讯科技有限公司 ShenzhenQianmuCommunicationTechnologyCo.,Ltd. 联系人:王志强联系方式:13760153961电话:0755-21633653传真:0755-21633541 深圳市宝安区航城街道三围社区航空路华丰智谷-航城高科技产业园A座4层425、443号 Acceptanceofantennasamples Applicable model BBT076-S7C-80 Customer Specificationdescription ProductcontentSpecificationMnemoniccodeMaterialcode Specification description WIFIantenna FPC/Black/Character QM-BBT076-S7C+Wire (1.13*80mm) Changeofresume Serialnumber DateVersionBriefdescriptionofthechanges 1 2021-11-03V1.0Newproject 2 3 Suppliersampleconfirmation Researchand development StructureAuditJudgement PASS FAIL Customersampleconfirmation ElectronStructureProjectProcurementQualityAudit Reasonsforrejectionorotherprecautions: 1、Matchingcircuit-WIFIantenna 2、WIFIantennaefficiency 3、Structuraldrawings

Test Report

FCCID: 2BBYL-H9 1 Case No. : GTS20230523010-1-14 Ambient Condition: 23 °C, 49 %RH, Atmos100.1Kpa, Test Date: 2023.6.14 Test Engineer: Jenny zeng Appendix D.1: Emission Bandwidth Test Result Test Mode Antenna Frequency[MHz] 26db EBW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11A Ant1 5180 24.240 5167.800 5192.040 --- --- 5200 24.360 5187.720 5212.080 --- --- 5240 23.960 5227.800 5251.760 --- --- 11N20SISO Ant1 5180 24.520 5167.760 5192.280 --- --- 5200 24.720 5187.800 5212.520 --- --- 5240 25.160 5227.360 5252.520 --- --- 11N40SISO Ant1 5190 47.520 5166.320 5213.840 --- --- 5230 47.600 5206.320 5253.920 --- --- 11AC20SISO Ant1 5180 25.160 5167.640 5192.800 --- --- 5200 25.280 5187.080 5212.360 --- --- 5240 24.680 5227.560 5252.240 --- --- 11AC40SISO Ant1 5190 46.800 5167.040 5213.840 --- --- 5230 46.640 5206.560 5253.200 --- --- 11AX20SISO Ant1 5180 25.600 5167.120 5192.720 --- --- 5200 26.000 5186.440 5212.440 --- --- 5240 24.880 5227.840 5252.720 --- --- 11AX40SISO Ant1 5190 45.040 5167.520 5212.560 --- --- 5230 45.280 5206.560 5251.840 --- --- FCCID: 2BBYL-H9 2 Test Graphs 11A_Ant1_5180 11A_Ant1_5200 FCCID: 2BBYL-H9 3 11A_Ant1_5240 11N20SISO_Ant1_5180 11N20SISO_Ant1_5200 FCCID: 2BBYL-H9 4 11N20SISO_Ant1_5240 11N40SISO_Ant1_5190 FCCID: 2BBYL-H9 5 11N40SISO_Ant1_5230 11AC20SISO_Ant1_5180 11AC20SISO_Ant1_5200 FCCID: 2BBYL-H9 6 11AC20SISO_Ant1_5240 11AC40SISO_Ant1_5190 FCCID: 2BBYL-H9 7 11AC40SISO_Ant1_5230 11AX20SISO_Ant1_5180 11AX20SISO_Ant1_5200 FCCID: 2BBYL-H9 8 11AX20SISO_Ant1_5240 11AX40SISO_Ant1_5190 11AX40SISO_Ant1_5230 FCCID: 2BBYL-H9 9 Appendix D.2: Occupied channel bandwidth Test Result Test Mode Antenna Frequency[MHz] OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11A Ant1 5180 17.691 5171.045 5188.736 --- --- 5200 17.895 5190.914 5208.809 --- --- 5240 17.986 5230.858 5248.844 --- --- 11N20SISO Ant1 5180 19.028 5170.443 5189.471 --- --- 5200 19.147 5190.346 5209.493 --- --- 5240 19.026 5230.435 5249.461 --- --- 11N40SISO Ant1 5190 37.664 5171.063 5208.727 --- --- 5230 37.628 5210.987 5248.615 --- --- 11AC20SISO Ant1 5180 19.226 5170.528 5189.754 --- --- 5200 19.167 5190.513 5209.680 --- --- 5240 19.212 5230.445 5249.657 --- --- 11AC40SISO Ant1 5190 37.485 5171.321 5208.806 --- --- 5230 37.622 5211.121 5248.743 --- --- 11AX20SISO Ant1 5180 19.766 5170.118 5189.884 --- --- 5200 19.634 5190.161 5209.795 --- --- 5240 19.603 5230.141 5249.744 --- --- 11AX40SISO Ant1 5190 38.337 5170.842 5209.179 --- --- 5230 38.367 5210.791 5249.158 --- --- FCCID: 2BBYL-H9 10 Test Graphs 11A_Ant1_5180 11A_Ant1_5200 FCCID: 2BBYL-H9 11 11A_Ant1_5240 11N20SISO_Ant1_5180 FCCID: 2BBYL-H9 12 11N20SISO_Ant1_5200 11N20SISO_Ant1_5240 11N40SISO_Ant1_5190 FCCID: 2BBYL-H9 13 11N40SISO_Ant1_5230 11AC20SISO_Ant1_5180 FCCID: 2BBYL-H9 14 11AC20SISO_Ant1_5200 11AC20SISO_Ant1_5240 11AC40SISO_Ant1_5190 FCCID: 2BBYL-H9 15 11AC40SISO_Ant1_5230 11AX20SISO_Ant1_5180 FCCID: 2BBYL-H9 16 11AX20SISO_Ant1_5200 11AX20SISO_Ant1_5240 11AX40SISO_Ant1_5190 FCCID: 2BBYL-H9 17 11AX40SISO_Ant1_5230 FCCID: 2BBYL-H9 18 Appendix D.3: Duty Cycle Test Result Test Mode Antenna Frequency[MHz] Transmission Duration [ms] Transmission Period [ms] Duty Cycle [%] 11A Ant1 5180 2.03 2.35 86.38 5200 2.03 2.20 92.27 5240 2.04 2.29 89.08 11N20SISO Ant1 5180 1.89 2.12 89.15 5200 1.89 2.07 91.30 5240 1.89 2.50 75.60 11N40SISO Ant1 5190 0.93 1.15 80.87 5230 0.93 1.08 86.11 11AC20SISO Ant1 5180 1.90 2.13 89.20 5200 1.90 2.28 83.33 5240 1.90 2.07 91.79 11AC40SISO Ant1 5190 0.94 1.08 87.04 5230 0.94 1.95 48.21 11AX20SISO Ant1 5180 1.46 1.67 87.43 5200 1.45 1.65 87.88 5240 1.45 1.74 83.33 11AX40SISO Ant1 5190 0.74 1.04 71.15 5230 0.74 1.23 60.16 FCCID: 2BBYL-H9 19 Test Graphs 11A_Ant1_5180 11A_Ant1_5200 FCCID: 2BBYL-H9 20 11A_Ant1_5240 11N20SISO_Ant1_5180 FCCID: 2BBYL-H9 21 11N20SISO_Ant1_5200 11N20SISO_Ant1_5240 11N40SISO_Ant1_5190 FCCID: 2BBYL-H9 22 11N40SISO_Ant1_5230 11AC20SISO_Ant1_5180 FCCID: 2BBYL-H9 23 11AC20SISO_Ant1_5200 11AC20SISO_Ant1_5240 11AC40SISO_Ant1_5190 FCCID: 2BBYL-H9 24 11AC40SISO_Ant1_5230 11AX20SISO_Ant1_5180 FCCID: 2BBYL-H9 25 11AX20SISO_Ant1_5200 11AX20SISO_Ant1_5240 11AX40SISO_Ant1_5190 FCCID: 2BBYL-H9 26 11AX40SISO_Ant1_5230 FCCID: 2BBYL-H9 27 Appendix D.4: Maximum conducted output power Test Result Channel Power Test Mode Antenna Frequency[MH z] Channel Powert [dBm] Duty Cycle [%] DC Factor [dBm] Result [dBm] Limit [dBm] Verdict 11A Ant1 5180 9.00 86.38 0.64 9.64 ≤23.98 PASS 5200 8.80 92.27 0.35 9.15 ≤23.98 PASS 5240 8.28 89.08 0.50 8.78 ≤23.98 PASS 11N20SISO Ant1 5180 8.76 89.15 0.50 9.26 ≤23.98 PASS 5200 8.64 91.30 0.40 9.04 ≤23.98 PASS 5240 8.16 75.60 1.21 9.37 ≤23.98 PASS 11N40SISO Ant1 5190 8.26 80.87 0.92 9.18 ≤23.98 PASS 5230 8.48 86.11 0.65 9.13 ≤23.98 PASS 11AC20SISO Ant1 5180 9.37 89.20 0.50 9.87 ≤23.98 PASS 5200 9.33 83.33 0.79 10.12 ≤23.98 PASS 5240 8.56 91.79 0.37 8.93 ≤23.98 PASS 11AC40SISO Ant1 5190 8.75 87.04 0.60 9.35 ≤23.98 PASS 5230 8.46 48.21 3.17 11.63 ≤23.98 PASS 11AX20SISO Ant1 5180 9.65 87.43 0.58 10.23 ≤23.98 PASS 5200 9.33 87.88 0.56 9.89 ≤23.98 PASS 5240 8.07 83.33 0.79 8.86 ≤23.98 PASS 11AX40SISO Ant1 5190 8.70 71.15 1.48 10.18 ≤23.98 PASS 5230 8.07 60.16 2.21 10.28 ≤23.98 PASS Note:The Duty Cycle Factor is compensated in the graph. FCCID: 2BBYL-H9 28 Appendix D.5: Maximum power spectral density Test Result Test Mode Antenna Frequency[MHz] Result [dBm/MHz] Limit[dBm/MHz] Verdict 11A Ant1 5180 -1.74 ≤11.00 PASS 5200 -2.15 ≤11.00 PASS 5240 -2.48 ≤11.00 PASS 11N20SISO Ant1 5180 -2.37 ≤11.00 PASS 5200 -2.49 ≤11.00 PASS 5240 -1.98 ≤11.00 PASS 11N40SISO Ant1 5190 -5.51 ≤11.00 PASS 5230 -5.24 ≤11.00 PASS 11AC20SISO Ant1 5180 -1.66 ≤11.00 PASS 5200 -1.29 ≤11.00 PASS 5240 -2.16 ≤11.00 PASS 11AC40SISO Ant1 5190 -4.86 ≤11.00 PASS 5230 -2.68 ≤11.00 PASS 11AX20SISO Ant1 5180 -1.64 ≤11.00 PASS 5200 -1.84 ≤11.00 PASS 5240 -1.99 ≤11.00 PASS 11AX40SISO Ant1 5190 -4.2 ≤11.00 PASS 5230 -3.59 ≤11.00 PASS Note:1.The Result and Limit Unit is dBm/500 kHz in the band 5.7255.85 GHz. 2.The Duty Cycle Factor and RBW Factor is compe…

Text truncated - open the document above for the full version.

Test Report

FCCID: 2BBYL-H9 43 Appendix D.7: Conducted Spurious Emission Test Result Test Mode Antenna Frequency[MHz] FreqRange [MHz] Max. Fre [MHz] Max. Level [dBm] Limit [dBm] Verdict 11A Ant1 5180 30~5140 4136.91 -39.71 ≤-27 PASS 5360~40000 25987.25 -37.36 ≤-27 PASS 5200 30~5140 4154.28 -40.47 ≤-27 PASS 5360~40000 26728.78 -37.78 ≤-27 PASS 5240 30~5140 4185.96 -40.92 ≤-27 PASS 5360~40000 26687.66 -37.25 ≤-27 PASS 11N20SISO Ant1 5180 30~5140 4138.27 -40.11 ≤-27 PASS 5360~40000 24814.36 -38.38 ≤-27 PASS 5200 30~5140 4152.75 -40.57 ≤-27 PASS 5360~40000 24812.2 -37.74 ≤-27 PASS 5240 30~5140 4184.26 -40.74 ≤-27 PASS 5360~40000 26073.09 -37 ≤-27 PASS 11N40SISO Ant1 5190 30~5140 4135.37 -36.35 ≤-27 PASS 5360~40000 6211.17 -37.12 ≤-27 PASS 5230 30~5140 4167.4 -36.02 ≤-27 PASS 5360~40000 6260.22 -36.73 ≤-27 PASS 11AC20SISO Ant1 5180 30~5140 4135.71 -39.84 ≤-27 PASS 5360~40000 26138.01 -38 ≤-27 PASS 5200 30~5140 4152.07 -39.97 ≤-27 PASS 5360~40000 26694.15 -38.29 ≤-27 PASS 5240 30~5140 4183.92 -40.27 ≤-27 PASS 5360~40000 25718.91 -38.2 ≤-27 PASS 11AC40SISO Ant1 5190 30~5140 4134.86 -36 ≤-27 PASS 5360~40000 6211.89 -36.99 ≤-27 PASS 5230 30~5140 4166.89 -36.37 ≤-27 PASS 5360~40000 24261.82 -37.74 ≤-27 PASS 11AX20SISO Ant1 5180 30~5140 4135.54 -38.37 ≤-27 PASS 5360~40000 24267.59 -37.43 ≤-27 PASS 5200 30~5140 4151.22 -39.52 ≤-27 PASS 5360~40000 25507.56 -37.89 ≤-27 PASS 5240 30~5140 4183.58 -38.24 ≤-27 PASS 5360~40000 24270.47 -38.29 ≤-27 PASS 11AX40SISO Ant1 5190 30~5140 4135.89 -33.98 ≤-27 PASS 5360~40000 6210.45 -34.71 ≤-27 PASS 5230 30~5140 4165.52 -36.2 ≤-27 PASS 5360~40000 6258.78 -36.17 ≤-27 PASS FCCID: 2BBYL-H9 44 Test Graphs 11A_Ant1_5180_30~5140 11A_Ant1_5180_5360~40000 FCCID: 2BBYL-H9 45 11A_Ant1_5200_30~5140 11A_Ant1_5200_5360~40000 FCCID: 2BBYL-H9 46 11A_Ant1_5240_30~5140 11A_Ant1_5240_5360~40000 11N20SISO_Ant1_5180_30~5140 FCCID: 2BBYL-H9 47 11N20SISO_Ant1_5180_5360~40000 11N20SISO_Ant1_5200_30~5140 FCCID: 2BBYL-H9 48 11N20SISO_Ant1_5200_5360~40000 11N20SISO_Ant1_5240_30~5140 11N20SISO_Ant1_5240_5360~40000 FCCID: 2BBYL-H9 49 11N40SISO_Ant1_5190_30~5140 11N40SISO_Ant1_5190_5360~40000 FCCID: 2BBYL-H9 50 11N40SISO_Ant1_5230_30~5140 11N40SISO_Ant1_5230_5360~40000 11AC20SISO_Ant1_5180_30~5140 FCCID: 2BBYL-H9 51 11AC20SISO_Ant1_5180_5360~40000 11AC20SISO_Ant1_5200_30~5140 FCCID: 2BBYL-H9 52 11AC20SISO_Ant1_5200_5360~40000 11AC20SISO_Ant1_5240_30~5140 11AC20SISO_Ant1_5240_5360~40000 FCCID: 2BBYL-H9 53 11AC40SISO_Ant1_5190_30~5140 11AC40SISO_Ant1_5190_5360~40000 FCCID: 2BBYL-H9 54 11AC40SISO_Ant1_5230_30~5140 11AC40SISO_Ant1_5230_5360~40000 11AX20SISO_Ant1_5180_30~5140 FCCID: 2BBYL-H9 55 11AX20SISO_Ant1_5180_5360~40000 11AX20SISO_Ant1_5200_30~5140 FCCID: 2BBYL-H9 56 11AX20SISO_Ant1_5200_5360~40000 11AX20SISO_Ant1_5240_30~5140 11AX20SISO_Ant1_5240_5360~40000 FCCID: 2BBYL-H9 57 11AX40SISO_Ant1_5190_30~5140 11AX40SISO_Ant1_5190_5360~40000 FCCID: 2BBYL-H9 58 11AX40SISO_Ant1_5230_30~5140 11AX40SISO_Ant1_5230_5360~40000 FCCID: 2BBYL-H9 59 Appendix D.8: Emissions in Restricted Bands Test Result Test Mode Antenna ChName Frequency [MHz] Detector Freq [MHz] Result [dBm] Limit [dBm] Result [dBuV/m] Limit [dBuV/m] Verdict 11A Ant1 Low 5180 AV 4500.000 -47.77 ≤-41.20 47.43 ≤54 PASS AV 4917.200 -45.29 ≤-41.20 49.91 ≤54 PASS AV 5150.000 -46.82 ≤-41.20 48.38 ≤54 PASS Peak 4500.000 -39.27 ≤-21.20 55.93 ≤74 PASS Peak 4978.100 -35.03 ≤-21.20 60.17 ≤74 PASS Peak 5150.000 -39.9 ≤-21.20 55.30 ≤74 PASS High 5240 AV 5350.000 -46.56 ≤-41.20 48.64 ≤54 PASS AV 5447.040 -45.31 ≤-41.20 49.89 ≤54 PASS AV 5460.000 -45.48 ≤-41.20 49.72 ≤54 PASS Peak 5350.000 -40.85 ≤-21.20 54.35 ≤74 PASS Peak 5453.040 -35.56 ≤-21.20 59.64 ≤74 PASS Peak 5460.000 -38.05 ≤-21.20 57.15 ≤74 PASS 11N20SIS O Ant1 Low 5180 AV 4500.000 -47.7 ≤-41.20 47.50 ≤54 PASS AV 4946.600 -45.36 ≤-41.20 49.84 ≤54 PASS AV 5150.000 -46.66 ≤-41.20 48.54 ≤54 PASS Peak 4500.000 -40.42 ≤-21.20 54.78 ≤74 PASS Peak 5012.400 -35.97 ≤-21.20 59.23 ≤74 PASS Peak 5150.000 -38.89 ≤-21.20 56.31 ≤74 PASS High 5240 AV 5350.000 -46.59 ≤-41.20 48.61 ≤54 PASS AV 5452.320 -45.26 ≤-41.20 49.94 ≤54 PASS AV 5460.000 -45.45 ≤-41.20 49.75 ≤54 PASS Peak 5350.000 -39.13 ≤-21.20 56.07 ≤74 PASS Peak 5364.000 -35.98 ≤-21.20 59.22 ≤74 PASS Peak 5460.000 -36.2 ≤-21.20 59.00 ≤74 PASS 11N40SIS O Ant1 Low 5190 AV 4500.000 -47.42 ≤-41.20 47.78 ≤54 PASS AV 4908.800 -44.82 ≤-41.20 50.38 ≤54 PASS AV 5150.000 -46.21 ≤-41.20 48.99 ≤54 PASS Peak 4500.000 -39.15 ≤-21.20 56.05 ≤74 PASS Peak 5148.900 -35.2 ≤-21.20 60.00 ≤74 PASS Peak 5150.000 -37.56 ≤-21.20 57.64 ≤74 PASS High 5230 AV 5350.000 -46.35 ≤-41.20 48.85 ≤54 PASS AV 5456.620 -45 ≤-41.20 50.20 ≤54 PASS AV 5460.000 -45.14 ≤-41.20 50.06 ≤54 PASS Peak 5350.000 -39.27 ≤-21.20 55.93 ≤74 PASS Peak 5456.360 -35.19 ≤-21.20 60.01 ≤74 PASS Peak 5460.000 -39.05 ≤-21.20 56.15 ≤74 PASS FCCID: 2BBYL-H9 60 11AC20SI SO Ant1 Low 5180 AV 4500.000 -47.75 ≤-41.20 47.45 ≤54 PASS AV 4946.600 -45.26 ≤-41.20 49.94 ≤54 PASS AV 5150.000 -46.62 ≤-41.20 48.58 ≤54 PASS Peak 4500.000 -40.23 ≤-21.20 54.97 ≤74 PASS Peak 5022.200 -35.51 ≤-21.20 59.69 ≤74 PASS Peak 5150.000 -39.03 ≤-21.20 56.17 ≤74 PASS High 5240 AV 5350.000 -46.46 ≤-41.20 48.74 ≤54 PASS AV 5454.720 -45.17 ≤-41.20 50.03 ≤54 PASS AV 5460.000 -45.42 ≤-41.20 49.78 ≤54 PASS Peak 5350.000 -39.78 ≤-21.20 55.42 ≤74 PASS Peak 5444.640 -36.06 ≤-21.20 59.14 ≤74 PASS Peak 5460.000 -38.61 ≤-21.20 56.59 ≤74 PASS 11AC40SI SO Ant1 Low 5190 AV 4500.000 -47.31 ≤-41.20 47.89 ≤54 PASS AV 4929.100 -44.9 ≤-41.20 50.30 ≤54 PASS AV 5150.000 -45.54 ≤-41.20 49.66 ≤54 PASS Peak 4500.000 -40.54 ≤-21.20 54.66 ≤74 PASS Peak 4976.000 -35.71 ≤-21.20 59.49 ≤74 PASS Peak 5150.000 -39.26 ≤-21.20 55.94 ≤74 PASS High 5230 AV 5350.000 -46.09 ≤-41.20 49.11 ≤54 PASS AV 5458.700 -44.88 ≤-41.20 50.32 ≤54 PASS AV 5460.000 -45.16 ≤-41.20 50.04 ≤54 PASS Peak 5350.000 -38.29 ≤-21.20 56.91 ≤74 PASS Peak 5451.160 -35.54 ≤-21.20 59.66 ≤74 PASS Peak 5460.000 -37.56 ≤-21.20 57.64 ≤74 PASS 11AX20SI SO Ant1 Low 5180 AV 4500.000 -47.59 ≤-41.20 47.61 ≤54 PASS AV 4944.500 -45.07 …

Text truncated - open the document above for the full version.

Test Report

FCCID: 2BBYL-H9 1 Case No. : GTS20230523010-1-14 Ambient Condition: 24 °C, 49 %RH, Atmos100.1Kpa, Test Date: 2023.6.15 Test Engineer: Jenny zeng Appendix E.1: Occupied channel bandwidth Test Result Test Mode Antenna Frequency[MHz] OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11A Ant1 5745 17.973 5735.848 5753.821 --- --- 5785 18.060 5775.750 5793.810 --- --- 5825 17.864 5815.847 5833.711 --- --- 11N20SISO Ant1 5745 19.208 5735.316 5754.524 --- --- 5785 19.143 5775.345 5794.488 --- --- 5825 19.179 5815.215 5834.394 --- --- 11N40SISO Ant1 5755 37.900 5736.048 5773.948 --- --- 5795 37.706 5775.950 5813.656 --- --- 11AC20SISO Ant1 5745 19.343 5735.410 5754.753 --- --- 5785 19.230 5775.384 5794.614 --- --- 5825 19.284 5815.317 5834.601 --- --- 11AC40SISO Ant1 5755 37.835 5736.129 5773.964 --- --- 5795 37.620 5776.073 5813.693 --- --- 11AX20SISO Ant1 5745 19.900 5734.962 5754.862 --- --- 5785 19.598 5775.167 5794.765 --- --- 5825 19.677 5815.103 5834.780 --- --- 11AX40SISO Ant1 5755 38.367 5735.779 5774.146 --- --- 5795 38.371 5775.735 5814.106 --- --- FCCID: 2BBYL-H9 2 Test Graphs 11A_Ant1_5745 11A_Ant1_5785 FCCID: 2BBYL-H9 3 11A_Ant1_5825 11N20SISO_Ant1_5745 FCCID: 2BBYL-H9 4 11N20SISO_Ant1_5785 11N20SISO_Ant1_5825 11N40SISO_Ant1_5755 FCCID: 2BBYL-H9 5 11N40SISO_Ant1_5795 11AC20SISO_Ant1_5745 FCCID: 2BBYL-H9 6 11AC20SISO_Ant1_5785 11AC20SISO_Ant1_5825 11AC40SISO_Ant1_5755 FCCID: 2BBYL-H9 7 11AC40SISO_Ant1_5795 11AX20SISO_Ant1_5745 FCCID: 2BBYL-H9 8 11AX20SISO_Ant1_5785 11AX20SISO_Ant1_5825 11AX40SISO_Ant1_5755 FCCID: 2BBYL-H9 9 11AX40SISO_Ant1_5795 FCCID: 2BBYL-H9 10 Appendix E.2: Min emission bandwidth Test Result B4 Test Mode Antenna Frequency[MHz] 6db EBW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11A Ant1 5745 16.280 5736.840 5753.120 0.5 PASS 5785 16.360 5776.800 5793.160 0.5 PASS 5825 16.280 5816.840 5833.120 0.5 PASS 11N20SISO Ant1 5745 17.560 5736.200 5753.760 0.5 PASS 5785 17.560 5776.200 5793.760 0.5 PASS 5825 17.560 5816.200 5833.760 0.5 PASS 11N40SISO Ant1 5755 36.320 5736.840 5773.160 0.5 PASS 5795 35.920 5776.840 5812.760 0.5 PASS 11AC20SISO Ant1 5745 17.560 5736.200 5753.760 0.5 PASS 5785 17.560 5776.200 5793.760 0.5 PASS 5825 17.560 5816.200 5833.760 0.5 PASS 11AC40SISO Ant1 5755 36.320 5736.840 5773.160 0.5 PASS 5795 35.920 5776.840 5812.760 0.5 PASS 11AX20SISO Ant1 5745 18.880 5735.600 5754.480 0.5 PASS 5785 18.960 5775.520 5794.480 0.5 PASS 5825 18.960 5815.480 5834.440 0.5 PASS 11AX40SISO Ant1 5755 37.840 5736.040 5773.880 0.5 PASS 5795 37.840 5776.040 5813.880 0.5 PASS FCCID: 2BBYL-H9 11 Test Graphs B4 11A_Ant1_5745 11A_Ant1_5785 FCCID: 2BBYL-H9 12 11A_Ant1_5825 11N20SISO_Ant1_5745 FCCID: 2BBYL-H9 13 11N20SISO_Ant1_5785 11N20SISO_Ant1_5825 11N40SISO_Ant1_5755 FCCID: 2BBYL-H9 14 11N40SISO_Ant1_5795 11AC20SISO_Ant1_5745 FCCID: 2BBYL-H9 15 11AC20SISO_Ant1_5785 11AC20SISO_Ant1_5825 11AC40SISO_Ant1_5755 FCCID: 2BBYL-H9 16 11AC40SISO_Ant1_5795 11AX20SISO_Ant1_5745 FCCID: 2BBYL-H9 17 11AX20SISO_Ant1_5785 11AX20SISO_Ant1_5825 11AX40SISO_Ant1_5755 FCCID: 2BBYL-H9 18 11AX40SISO_Ant1_5795 FCCID: 2BBYL-H9 19 Appendix E.3: Duty Cycle Test Result Test Mode Antenna Frequency[MHz] Transmission Duration [ms] Transmission Period [ms] Duty Cycle [%] 11A Ant1 5745 2.03 2.13 95.31 5785 2.03 2.14 94.86 5825 2.03 2.18 93.12 11N20SISO Ant1 5745 1.89 2.07 91.30 5785 1.89 2.07 91.30 5825 1.89 2.12 89.15 11N40SISO Ant1 5755 0.93 1.17 79.49 5795 0.93 1.09 85.32 11AC20SISO Ant1 5745 1.90 2.04 93.14 5785 1.90 1.99 95.48 5825 1.90 2.08 91.35 11AC40SISO Ant1 5755 0.93 1.06 87.74 5795 0.93 1.10 84.55 11AX20SISO Ant1 5745 1.45 1.61 90.06 5785 1.46 1.63 89.57 5825 1.45 1.59 91.19 11AX40SISO Ant1 5755 0.74 0.91 81.32 5795 0.75 0.92 81.52 FCCID: 2BBYL-H9 20 Test Graphs 11A_Ant1_5745 11A_Ant1_5785 FCCID: 2BBYL-H9 21 11A_Ant1_5825 11N20SISO_Ant1_5745 FCCID: 2BBYL-H9 22 11N20SISO_Ant1_5785 11N20SISO_Ant1_5825 11N40SISO_Ant1_5755 FCCID: 2BBYL-H9 23 11N40SISO_Ant1_5795 11AC20SISO_Ant1_5745 FCCID: 2BBYL-H9 24 11AC20SISO_Ant1_5785 11AC20SISO_Ant1_5825 11AC40SISO_Ant1_5755 FCCID: 2BBYL-H9 25 11AC40SISO_Ant1_5795 11AX20SISO_Ant1_5745 FCCID: 2BBYL-H9 26 11AX20SISO_Ant1_5785 11AX20SISO_Ant1_5825 11AX40SISO_Ant1_5755 FCCID: 2BBYL-H9 27 11AX40SISO_Ant1_5795 FCCID: 2BBYL-H9 28 Appendix E.4: Maximum conducted output power Test Result Channel Power Test Mode Antenna Frequency[MH z] Channel Powert [dBm] Duty Cycle [%] DC Factor [dBm] Result [dBm] Limit [dBm] Verdict 11A Ant1 5745 11.16 95.31 0.21 11.37 ≤30.00 PASS 5785 10.94 94.86 0.23 11.17 ≤30.00 PASS 5825 9.86 93.12 0.31 10.17 ≤30.00 PASS 11N20SISO Ant1 5745 10.97 91.30 0.40 11.37 ≤30.00 PASS 5785 10.40 91.30 0.40 10.80 ≤30.00 PASS 5825 9.23 89.15 0.50 9.73 ≤30.00 PASS 11N40SISO Ant1 5755 10.43 79.49 1.00 11.43 ≤30.00 PASS 5795 10.26 85.32 0.69 10.95 ≤30.00 PASS 11AC20SISO Ant1 5745 10.87 93.14 0.31 11.18 ≤30.00 PASS 5785 10.67 95.48 0.20 10.87 ≤30.00 PASS 5825 9.31 91.35 0.39 9.70 ≤30.00 PASS 11AC40SISO Ant1 5755 10.27 87.74 0.57 10.84 ≤30.00 PASS 5795 10.01 84.55 0.73 10.74 ≤30.00 PASS 11AX20SISO Ant1 5745 10.58 90.06 0.45 11.03 ≤30.00 PASS 5785 10.75 89.57 0.48 11.23 ≤30.00 PASS 5825 9.34 91.19 0.40 9.74 ≤30.00 PASS 11AX40SISO Ant1 5755 10.21 81.32 0.90 11.11 ≤30.00 PASS 5795 10.08 81.52 0.89 10.97 ≤30.00 PASS Note:The Duty Cycle Factor is compensated in the graph. FCCID: 2BBYL-H9 29 Appendix E.5: Maximum power spectral density Test Result Test Mode Antenna Frequency[MHz] Result [dBm/MHz] Limit[dBm/MHz] Verdict 11A Ant1 5745 -2.71 ≤30.00 PASS 5785 -2.58 ≤30.00 PASS 5825 -3.79 ≤30.00 PASS 11N20SISO Ant1 5745 -2.93 ≤30.00 PASS 5785 -3.56 ≤30.00 PASS 5825 -4.61 ≤30.00 PASS 11N40SISO Ant1 5755 -6.09 ≤30.00 PASS 5795 -6.41 ≤30.00 PASS 11AC20SISO Ant1 5745 -3.27 ≤30.00 PASS 5785 -3.15 ≤30.00 PASS 5825 -4.5 ≤30.00 PASS 11AC40SISO Ant1 5755 -6.82 ≤30.00 PASS 5795 -6.55 ≤30.00 PASS 11AX20SISO Ant1 5745 -3.59 ≤30.00 PASS…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Defeng Zeng(QA Manager)
[email protected]13590790364Fax: /

Test Firm

Shenzhen Global Test Service Co., Ltd.Simon Hu
[email protected]86-137-286-828-40

Technical Specifications

#Rule PartsFrequency RangePower Output
215E5.75 GHz - 5.83 GHz13.90 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum peak conducted output power. The device supports 20 MHz,40 MHz bandwidth and a/n/ac/ax modes. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. The device also supports 2.4GHzWLAN, BT and BLE transmitters.