Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Do noound t push the chair ar Do not placour weight e all y
HenglinHomeFurnishingsCo.,Ltd FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 7/1/24 U.S.AgentDesignation HenglinHomeFurnishingsCo.,LtdacknowledgestheirconsentforthefollowingcontactlocatedintheUnited Statestoactastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCCID: 2BBYO-6100): NameandcompanyofU.S.agent:COLAMYINC PhysicalU.S.addressofagent:10985OLEANDERAVENUEFONTANA,CA92337 FRNofU.S.agent:0035548023 EmailaddressofU.S.agent:[email protected] COLAMYINCacknowledgestheirobligationtoacceptserviceofprocessonbehalfofHenglinHome FurnishingsCo.,Ltd. HenglinHomeFurnishingsCo.,LtdwiththeFRN0033978800acceptsitsobligationtomaintainanagentfor serviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofany Commission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature XueDongDeng Manager HenglinHomeFurnishingsCo.,Ltd Signature WuXinyu Manager COLAMYINC 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5
Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: Henglin Home Furnishings Co., Ltd. Address: No.378, 380, Jiaxi Road, Dipu Subdistrict, Anji County, Huzhou, Zhejiang 313300, China Phone: +86-572-5228752 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-07-01 Name / Title: Xuedong Deng / Manager Company: Henglin Home Furnishings Co., Ltd. Address: No.378, 380, Jiaxi Road, Dipu Subdistrict, Anji County, Huzhou, Zhejiang 313300, China Phone: +86-572-5228752 Fax: +86-572-5227388 E-Mail: [email protected]
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BBYO-6100 HL-6100 We, applicant Company Name: Henglin Home Furnishings Co., Ltd. Address: No.378, 380, Jiaxi Road, Dipu Subdistrict, Anji County, Huzhou, Zhejiang 313300, China Phone: +86-572-5228752 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-07-01 Name / Title: Xuedong Deng / Manager Company: Henglin Home Furnishings Co., Ltd. Address: No.378, 380, Jiaxi Road, Dipu Subdistrict, Anji County, Huzhou, Zhejiang 313300, China Phone: +86-572-5228752 Fax: +86-572-5227388 E-Mail: [email protected]
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BBYO-6100 HL-6100 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-07-01 Name / Title: Xuedong Deng / Manager Company: Henglin Home Furnishings Co., Ltd. Address: No.378, 380, Jiaxi Road, Dipu Subdistrict, Anji County, Huzhou, Zhejiang 313300, China Phone: +86-572-5228752 Fax: +86-572-5227388 E-Mail: [email protected]
Page 1 of 5 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 5 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 5 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 5 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 5 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9
Page 1 of 1 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L4.0cm x W2.0cm) Label Location Massage Chair Model: HL-6100 FCC ID: 2BBYO-6100
Page 1 of 4 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Antenna
Page 1 of 3 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID : 2BBYO-6100 Product name : Massage Chair Test Model : HL-6100 Power Supply : Input: 110V~, 50/60Hz, 600mA Hardware Version : V0.1 Software Version V0.0.15 Bluetooth : 2402MHz~2480MHz Channel Number : 79 channels for Bluetooth V5.1(DSS) 40 channels for Bluetooth V5.1 (DTS) Channel Spacing : 1MHz for Bluetooth V5.1 (DSS) 2MHz for Bluetooth V5.1 (DTS) Modulation Type : GFSK, π/4-DQPSK for Bluetooth V5.1(DSS) GFSK for Bluetooth V5.1 (DTS) Bluetooth Version : V5.1 Antenna Type : PCB Antenna Antenna Gain : 1.9dBi Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · Page 2 of 3 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices 4. Conducted Power Results <BT> Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 0.59 39 2441 -0.36 78 2480 -0.09 π/4-DQPSK 0 2402 0.39 39 2441 -0.57 78 2480 -0.28 <BT LE> Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 0.51 19 2440 -0.46 39 2480 -0.14 Page 3 of 3 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 5. Manufacturing Tolerance <…
Text truncated - open the document above for the full version.
Product specification Quick Reference Date Antenna module on the system board Frequenc Range 2400 ~ 2500MHz Ant. Port Input Pwr. (dBm) 0 (Typ. BT class 2 output power) Tot. Rad. Pwr. (dBm) -1.2 (Input pwr – loss pwr) Peak EIRP(dBm) 1.2 Directivity (dBi) 1 (all direction antenna) Efficiency (dB) 6 0.2 % Gain (dBi) 1.9 (Peak Gain XZ-plane) Maximum Power (dBm) 1.7 (XY-plane) Minimum Power (dBm) -4(XY-plane) Avg. Power (dBm) -0.5(XY-plane) Input Impendence(ohm) 50 Polarization Type V ertical & Horizontal V . S .W . R < 1.4 All the technical data and information contained herein are subject to change without prior notice Antenna Layout & module on the system board Antenna Gain Gain Table Unit in dBi @2.44GHz XY-plane XZ-plane YZ-plane Efficiency Peak Avg. Peak Avg. Peak Avg. Module Board 1.2 -0.5 1.9 -3.6 1.1 -3.0 6 0.2 % Henglin Home Furnishings Co., Ltd. No.378, 380, Jiaxi Road, Dipu Subdistrict, Anji County, Huzhou, Zhejiang 313300, China Retum Loss The Environment of Antenna Radiation Pattem 3D radiation pattern diagram XY-plane XZ-plane YZ-plane
Page 1 of 42 FCC ID: 2BBYO-6100 Report No.: LCSA05314095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BT (Conducted Measurement) Product Name: Massage Chair Test Model: HL-6100 Environmental Conditions Temperature: 23.8 C Relative Humidity: 52.1% ATM Pressure: 100.0 kPa Test Engineer: Eason Zhou Supervised by: Nick Peng Page 2 of 42 FCC ID: 2BBYO-6100 Report No.: LCSA05314095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -20dB Bandwidth Condition Mode Frequency (MHz) Antenna -20 dB Bandwidth (MHz) Limit -20 dB Bandwidth (MHz) Verdict NVNT 1-DH5 2402 Ant1 1.032 N/A Pass NVNT 1-DH5 2441 Ant1 0.964 N/A Pass NVNT 1-DH5 2480 Ant1 1.026 N/A Pass NVNT 2-DH5 2402 Ant1 1.304 N/A Pass NVNT 2-DH5 2441 Ant1 1.278 N/A Pass NVNT 2-DH5 2480 Ant1 1.273 N/A Pass Page 3 of 42 FCC ID: 2BBYO-6100 Report No.: LCSA05314095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -20dB Bandwidth NVNT 1-DH5 2402MHz Ant1 -20dB Bandwidth NVNT 1-DH5 2441MHz Ant1 Page 4 of 42 FCC ID: 2BBYO-6100 Report No.: LCSA05314095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 1-DH5 2480MHz Ant1 -20dB Bandwidth NVNT 2-DH5 2402MHz Ant1 Page 5 of 42 FCC ID: 2BBYO-6100 Report No.: LCSA05314095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 2-DH5 2441MHz Ant1 -20dB Bandwidth NVNT 2-DH5 2480MHz Ant1 Page 6 of 42 FCC ID: 2BBYO-6100 Report No.: LCSA05314095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Total Power (dBm) Limit (dBm) Verdict NVNT 1-DH5 2402 Ant1 0.59 21 Pass NVNT 1-DH5 2441 Ant1 -0.36 21 Pass NVNT 1-DH5 2480 Ant1 -0.09 21 Pass NVNT 2-DH5 2402 Ant1 0.39 21 Pass NVNT 2-DH5 2441 Ant1 -0.57 21 Pass NVNT 2-DH5 2480 Ant1 -0.28 21 Pass Page 7 of 42 FCC ID: 2BBYO-6100 Report No.: LCSA05314095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT 1-DH5 2402MHz Ant1 Power NVNT 1-DH5 2441MHz Ant1 Page 8 of 42 FCC ID: 2BBYO-6100 Report No.: LCSA05314095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT 1-DH5 2480MHz Ant1 Power NVNT 2-DH5 2402MHz Ant1 Page 9 of 42 FCC ID: 2BBYO-6100 Report No.: LCSA05314095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT 2-DH5 2441MHz Ant1 Power NVNT 2-DH5 2480MHz Ant1 Page 10 of 42 FCC ID: 2BBYO-6100 Report No.: LCSA05314095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Carrier Frequencies Separation Condition Mode Antenna Hopping Freq1 (MHz) Hopping Freq2 (MHz) HFS (MHz) Limit (MHz) Verdict NVNT 1-DH5 Ant1 2401.958 2402.962 1.004 0.688 Pass NVNT 2-DH5 Ant1 2402.008 2403.004 0.996 0.869 Pass Page 11 of 42 FCC ID: 2BBYO-6100 Report No.: LCSA05314095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs CFS NVNT 1-DH5 2402MHz Ant1 CFS NVNT 2-DH5 2402MHz Ant1 Page 12 of 42 FCC ID: 2BBYO-6100 Report No.: LCSA05314095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.4 Dwell Time Condition Mode Frequency (MHz) Antenna Pulse Time (ms) Total Dwell Time (ms) Burst Count Period Time (ms) Limit (ms) Verdict NVNT 1-DH5 2402 Ant1 2.…
Text truncated - open the document above for the full version.
Page 1 of 37 FCCID:2BBYO-6100ReportNo.:LCSA05314095EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FOR HenglinHomeFurnishingsCo.,Ltd MassageChair TestModel:HL-6100 Preparedfor:HenglinHomeFurnishingsCo.,Ltd Address: No.378,380,JiaxiRoad,DipuSubdistrict,AnjiCounty,Huzhou City,ZhejiangPorvince,China. Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:June11,2024 Numberoftestedsamples:2 SampleNo. : A240530087-1,A240530087-2 Serialnumber:Prototype DateofTest:June11,2024~June25,2024 DateofReport:June25,2024 Page 2 of 37 FCCID:2BBYO-6100ReportNo.:LCSA05314095EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA05314095EA DateofIssue.......................................:June25,2024 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:HenglinHomeFurnishingsCo.,Ltd Address................................................: No.378,380,JiaxiRoad,DipuSubdistrict,AnjiCounty,Huzhou City,ZhejiangPorvince,China. TestSpecification Standard..............................................:FCCCFR47PART15C(15.247) TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription.....................:MassageChair TradeMark..........................................:N/A TestModel...........................................:HL-6100 Ratings.................................................:Input:110V~,50/60Hz,600mA Result..................................................:Positive Compiledby:Supervisedby:Approvedby: NadiaZhou/AdministratorCaryLuo/TechniqueprincipalGavinLiang/Manager Page 3 of 37 FCCID:2BBYO-6100ReportNo.:LCSA05314095EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestResult Positive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA05314095EA June25,2024 Dateofissue TestModel.............................. : HL-6100 EUT......................................... : MassageChair Applicant...............................:HenglinHomeFurnishingsCo.,Ltd Address...................................:No.378,380,JiaxiRoad,DipuSubdistrict,Anji County,HuzhouCity,ZhejiangPorvince,China. Telephone...............................:/ Fax..........................................:/ Manufacturer.........................:HenglinHomeFurnishingsCo.,Ltd Address...................................: No.378,380,JiaxiRoad,DipuSubdistrict,Anji County,HuzhouCity,ZhejiangPorvince,China. Telephone...............................:/ Fax..........................................:/ Factory...................................: HenglinHomeFurnishingsCo.,Ltd Address...................................: No.378,380,JiaxiRoad,DipuSubdistrict,Anji County,HuzhouCity,ZhejiangPorvince,China. Telephone...............................:/ Fax..........................................:/ Page 4 of 37 FCCID:2BBYO-6100ReportNo.:LCSA05314095EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000June25,2024InitialIssue--- Page 5 of 37 FCCID:2BBYO-6100ReportNo.:LCSA05314095EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS DescriptionPage 1.GENERALINFORMATION.........................................................................................................6 1.1DescriptionofDevice(EUT)...............................................................................................................6 1.2HostSystemConfigurationListandDetails.....................................................................................7 1.4DescriptionofTestFacility..................................................................................................................7…
Text truncated - open the document above for the full version.
Page 1 of 2 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photos of the EUT Test Setup Photo(s) of Radiated Emissions Measurement Fig. 1 Fig. 2 Page 2 of 2 FCC ID: 2BBYO-6100 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photo(s) of Conducted Emissions Measurement Fig. 3
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.10 mW |

Massage Chair
Equipment Class
DTS - Digital Transmission System