FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Š 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Rapid Conn Inc/
  3. 2BBYR-LUMI-CHILL

2BBYR-LUMI-CHILLLumi Chill LED ice bucket speaker

Rapid Conn Inc
Lumi Chill LED ice bucket speaker - FCC ID 2BBYR-LUMI-CHILL - Rapid Conn Inc
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 24, 2023
Application Purpose
Original Equipment
Date of Application
Aug 24, 2023
Equipment Note
Lumi Chill LED ice bucket speaker
Frequency Range
2402.00000000 - 2480.00000000
Company
Rapid Conn Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

LumiChillLEDIceBucketSpeaker INSTRUCTIONMANUAL DescriptionofParts 1.LumiChillLEDIceBucketSpeakerMainUnit 2.Speaker 3.Play/PauseButton(ON/OFF/PLAY/PAUSE) 4.LEDIndicatorLight 5.5VChargingPort 6.TypeCChargingCable 7.TypeCConnector Pleasereadalloftheinstructionscarefullyandretainforfuturereference. SafetyInstructions Whenusingelectricalproducts,basicsafetyprecautionsshouldalwaysbefollowed. Thisproductcanbeusedbychildrenagedfrom8yearsandaboveiftheyare continuouslysupervised.Thisproductcanbeusedbypeoplewithreducedphysical, sensoryormentalcapabilitiesorlackofexperienceandknowledgeiftheyhavebeen givensupervisionorinstructionconcerninguseoftheproductinasafewayand understandthehazardsinvolved. Unlesstheyareolderthan8andsupervised,childrenshouldnotperformcleaningorused maintenance. Thisproductisnotatoy. Thisproductcontainsnouserserviceableparts.Iftheproductandanyofitsaccessories aremalfunctioningorithasbeendroppedordamaged;theunitshouldberecycled. KeeptheproductandTypeCcableoutofthereachofchildren. KeeptheproductandTypeCcableawayfromtheheatorsharpedgesthatcouldcause damage. Keeptheproductawayfromheatsources,directsunlight,humidity,waterandanyother liquid. Ensuretheproductiswell-ventilated. Donotleaveanyobjectssusceptibletomagnetism(cashcards,floppydiskswith magneticcoding,etc.)neartheproduct. Donotoperatetheproductwithwethands. Donotoperatetheproductifithasbeenexposedtowater,moistureoranyotherliquid,to preventagainstelectricshock,explosionand/orinjurytoyourselfanddamagetothe product. Donotleavetheproductunattendedwhilstconnectedtoanotherdevice. Donotusetheproductforanythingotherthanitsintendeduse. Donotuseanyaccessoriesotherthanthosesupplied. Donotstoretheproductindirectsunlightorinhighhumidityconditions. Donotputobjectsintoanyoftheopenings. Donotplaymusicatexcessivevolumelevelsasdamagetohearingand/ortheproduct mayoccur. Thisproductmustbeplacedonastable,heat-resistantsurface. Thisproductisintendedfordomesticuseonly.Itshouldnotbeusedforcommercial purposes. Topreventpossiblehearingdamage,donotlistenathighvolumelevels forlongperiodsoftime. Warning:Keeptheproductawayfromflammablematerials. Batterysafety Thesupplyterminalsarenottobeshort-circuited. Intheeventofabatteryandcellleaking,donotallowtheliquidtocomeincontactwiththe skinoreyes.Ifcontacthasbeenmade,washtheaffectedareawithcopiousamountof waterandseekmedicaladvice. Donotuseanycellorbatterywhichisnotdesignedforusewiththeproduct. Secondarycellsandbatteriesneedtobechargedbeforeuse.Afterextendedperiodsof storage,itmaybenecessarytochargeanddischargethecellsorbatteriesseveraltimes toobtainmaximumperformance. Keepbatteriesoutofreachofchildren. Donotdisposedofbatteriesinafire. Donotdismantle,openorshredsecondarycellsorbatteries. Donotexposecellsorbatteriestoheatorfire. Donotcrush,puncture,dismantleorotherwisedamagebatteries. Donotstoreabove60°C. Avoidstorageindirectsunlight. Donotexposebatteriestoheatorfireastheymayexplode. Donotsubjectbatteriestomechanicalshock. Donotdisposeofexhaustedbatteriesinhouseholdwaste. Oncethebatterieshavebeenexhausted,disposeoftheunitatalocalrecyclingstation. Contactthelocalgovernmentofficesforfurtherdetails. Thisproductisfittedwitha2200mAhrechargeablebattery(non-removable). CareandMaintenance Wipethespeakerwithasoft,damp,lint-freeclothandallowtodrythoroughly. Thebucketcanbeseparatedfromthespeakerbasebyunscrewinginananticlockwise direction. Donot: Cleanthebucketorspeakersectioninadishwasher. Fullyimmersethespeakerinwateroranyotherliquid. Useanyabrasivecleaningsolventstocleanthespeaker,asthiscancausedamage. Exposethespeakertosharpobjects,whichmaycausedamage. Exposethespeakertoextremelyhighorlowtemperatures,asthiswillshortenthelifeof electronicdevices,destroythebatteryordistortcertainplasticparts. Dropthespeaker,astheinternalcircuitmaybecomedamaged. Attempttodisassemblethespeaker,asthismaycausedamagetothespeaker. Disposeofthespeakerinafire,asitwillresultinanexplosion. Usethespeakerasacontainerforconsumableliquid. Drinkdirectlyfromthespeaker. InstructionsforUse ChargingtheBattery Thespeakerisfittedwitha3.7V2200mAhbattery(non-removable).Itisrecommended thatthebatteryisfullychargedbeforefirstuse;thiswilltakeapprox.4hours. ConnectthemicroUSBendoftheUSBchargingcableintothe5Vchargingporton thespeakerandtheotherendtoacompatibleUSBport. Whilstcharging,theLEDindicatorlightwillilluminatered.Oncethebatteryhasfully charged,theLEDindicatorlightwillswitchoff. CarefullydisconnectbothendsoftheUSBchargingcableandstoreitsafelyforfuture use. **Maximumplaytimebasedon20%volumewithLEDlightfunctionswitchedoff. UsingtheLumiChillLEDIceBucketSpeaker BasicFunctionality Turnonthespeakerbypressingandholding‘ON/OFF/PLAY/PAUSE’forapprox..3 seconds. Pauseatrackbypressing‘ON/OFF/PLAY/PAUSE’;pushitagaintoresumethetrack. Pressandhold‘ON/OFF/PLAY/PAUSE’forapprox.3secondstoturnthespeakeroff. BluetoothMode STEP1:Oncethespeakerhasbeenturnedon,theLEDindicatorlightwillflashblueto signalthatthespeakerisreadytobepairedwithaBluetoothcompatibledevice. STEP2:SearchforthespeakerusingaBluetoothcompatibledevice.Select‘Lumi-Chill’ andpair.Onceaconnectionhasbeenmade,thespeakerwillplayatonetosignalthatthe devicesarepaired. STEP3:TounpairorremoveaBluetoothcompatibledevicefromthespeaker,turnoffthe Bluetoothfunctiononthecompatibledevice.Thespeakercannowbepairedwithanew compatibledevice. Note:Onceconnected,volumecanbecontrolledusingtherelevantcontrolsonthe Bluetoothcompatibledevice. Troubleshooting Thespeakerhasnopower. Thespeakerhasnopower. Chargethespeakerfollowingtheinstructionsinthesectionentitled‘ChargingtheBattery’. Thespeakerhasnosound. Thevolumelevelissettoolow. Checkthatthevolumelevelissetatanaudiblelevelandadjustaccordingly. Followtheinstructionsinthesectionentitled‘BluetoothMode’. UnabletopairaBluetoothdevicewiththespeaker. TheBluetoothdeviceisnotcompatiblewiththespeaker. CheckthattheBluetoothdeviceiscompatiblewiththespeakerandthattheBluetooth functionisswitchedon. Specifications ProductName:LumiChillLEDIceBucketSpeaker ProductCode:Lumi-Chill BluetoothVersion:5.0 WirelessRan…

Text truncated - open the document above for the full version.

Attestation Statements

Rev 1/26/2023 (Rapid Conn Inc) Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 08-25-2023 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: (2BBYR-LUMI-CHILL) [Rapid Conn Inc] (“the applicant”) certifies that, as of the date of the filing of the application, Rapid Conn Inc is our designated U.S. agent for service of process for the above referenced FCC ID. [Insert applicant name] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Rapid Conn Inc accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Rapid Conn Inc Address: 25172 Arctic Ocean Dr, STE 106 Lake Forest, CA 92630 United States Contact Person: Balaji Raghunathan Tel.: (949) 637-9280 Email: [email protected] FRN:0033980418 Sincerely, Rapid Conn Inc Rapid Conn Inc Balaji Raghunathan Balaji Raghunathan

Attestation Statements

Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: Rapid Conn Inc Address: 25172 ARCTIC OCEAN DR STE 106 LAKE FOREST, California 92630, United States Phone: +1-949-637-9280 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2023-08-24 Signature Date Name / Title: Balaji Raghunathan / VP of Operations Company: Rapid Conn Inc Address: 25172 ARCTIC OCEAN DR STE 106 LAKE FOREST, California 92630, United States Phone: +1-949-637-9280 Fax: N/A E-Mail: [email protected]

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BBYR-LUMI-CHILL Lumi-Chill We, applicant Company Name: Rapid Conn Inc Address: 25172 ARCTIC OCEAN DR STE 106 LAKE FOREST, California 92630, United States Phone: +1-949-637-9280 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2023-08-24 Signature Date Name / Title: Balaji Raghunathan / VP of Operations Company: Rapid Conn Inc Address: 25172 ARCTIC OCEAN DR STE 106 LAKE FOREST, California 92630, United States Phone: +1-949-637-9280 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BBYR-LUMI-CHILL Lumi-Chill For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2023-08-24 Signature Date Name / Title: Balaji Raghunathan / VP of Operations Company: Rapid Conn Inc Address: 25172 ARCTIC OCEAN DR STE 106 LAKE FOREST, California 92630, United States Phone: +1-949-637-9280 Fax: N/A E-Mail: [email protected]

External Photos

Page 1 of 4 FCC ID: 2BBYR-LUMI-CHILL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2BBYR-LUMI-CHILL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2BBYR-LUMI-CHILL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2BBYR-LUMI-CHILL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7

ID Label/Location Info

Page 1 of 1 FCC ID: 2BBYR-LUMI-CHILL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L2.5cm x 2.0cm) Label Location Lumi Chill LED ice bucket speaker Model: Lumi-Chill FCC ID: 2BBYR-LUMI-CHILL

Internal Photos

Page 1 of 4 FCC ID: 2BBYR-LUMI-CHILL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2BBYR-LUMI-CHILL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2BBYR-LUMI-CHILL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2BBYR-LUMI-CHILL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Antenna

RF Exposure Info

Page 1 of 3 FCC ID: 2BBYR-LUMI-CHILL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID : 2BBYR-LUMI-CHILL Product name : Lumi Chill LED ice bucket speaker Test Model : Lumi-Chill Power Supply : Input: DC 5V, 1000mA DC 3.7V by Rechargeable Li-ion Battery, 2200mAh Hardware Version : QT-098 AB5365A V1.0 20211028 Software Version : 486FE457 Bluetooth : 2402MHz ~ 2480MHz Channel Number : 40 channels for Bluetooth V5.0 (DTS) Channel Spacing : 2MHz for Bluetooth V5.0(DTS) Modulation Type : GFSK for Bluetooth V5.0 (DTS) Bluetooth Version : V5.0 Antenna Type : PCB Antenna Antenna Gain : 1.7dBi Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] ¡ [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm Page 2 of 3 FCC ID: 2BBYR-LUMI-CHILL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices Page 3 of 3 FCC ID: 2BBYR-LUMI-CHILL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4. Conducted Power Results <BT LE> Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 0.92 19 2440 -0.3 39 2480 -0.13 5. Manufacturing Tolerance <BT LE> GFSK (Peak) Channel Channel 0 Channel 19 Channel 39 Target (dBm) 0 0 0 Tolerance Âą(dB) 1.0 1.0 1.0 6. Evaluation Results 6.1 Standalone Evaluation B…

Text truncated - open the document above for the full version.

Test Report

Product specification Quick Reference Date All the technical data and information contained herein are subject to change without prior notice Antenna Layout &module on the system board Antenna Gain Gain Table Antenna module on the system board Frequency2.45GHz*1 Ant. Port Input Pwr. (dBm)0 (Typ. BT class 2 output power) Tot. Rad. Pwr. (dBm)-2.3 (Input pwr – loss pwr) Peak EIRP(dBm)1.3 Directivity (dBi)1(all direction antenna) Efficiency (dB)-2.3 (58.5%) Gain (dBi) 1.7 (Peak Gain XY-plane) Maximum Power (dBm)1.3 (XY-plane) Minimum Power (dBm)-4(XY-plane) Avg. Power (dBm)-0.5(XY-plane) Max/Min Ratio (dB)5.3(XY-plane) Max/Avg Ratio (dB)1.8(XY-plane) Min/Avg Ratio (dB)-3.5(XY-plane) Average Gain (dB)-0.5 (Avg Gain XY-plane) Unit in dBi @2.44GHz XY-planeXZ-planeYZ-planeEfficiency PeakAvg.PeakAvg.PeakAvg. Module Board 1.3-0.51.7-3.81.1-3.058.5% Shenzhen megahertz Technology Co., Ltd. Building A4, Yinlong Science Park, No. 292, Shenshan Road, Longgang District, Shenzhen, China ReturnLoss TheEnvironmentofAntennaRadiationPattern 3Dradiationpatterndiagram XY-planeXZ-planeYZ-plane

Test Report

Page 1 of 23 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BLE (Conducted Measurement) Product Name: Lumi Chill LED ice bucket speaker Test Model: Lumi-Chill Environmental Conditions Temperature: 23.5  C Relative Humidity: 52.2% ATM Pressure: 100.0 kPa Test Engineer: Ling Zhu Supervised by: Li Huan Page 2 of 23 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT BLE 1M 2402 Ant1 0.65 >=0.5 Pass NVNT BLE 1M 2440 Ant1 0.667 >=0.5 Pass NVNT BLE 1M 2480 Ant1 0.661 >=0.5 Pass Page 3 of 23 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT BLE 1M 2402MHz Ant1 -6dB Bandwidth NVNT BLE 1M 2440MHz Ant1 Page 4 of 23 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT BLE 1M 2480MHz Ant1 Page 5 of 23 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Total Power (dBm) Limit (dBm) Verdict NVNT BLE 1M 2402 Ant1 0.92 30 Pass NVNT BLE 1M 2440 Ant1 -0.3 30 Pass NVNT BLE 1M 2480 Ant1 -0.13 30 Pass Page 6 of 23 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT BLE 1M 2402MHz Ant1 Power NVNT BLE 1M 2440MHz Ant1 Page 7 of 23 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT BLE 1M 2480MHz Ant1 Page 8 of 23 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Total PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT BLE 1M 2402 Ant1 -15.92 8 Pass NVNT BLE 1M 2440 Ant1 -17.42 8 Pass NVNT BLE 1M 2480 Ant1 -16.96 8 Pass Page 9 of 23 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT BLE 1M 2402MHz Ant1 PSD NVNT BLE 1M 2440MHz Ant1 Page 10 of 23 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity PSD NVNT BLE 1M 2480MHz Ant1 Page 11 of 23 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.4 Band Edge Condition Mode Frequency (MHz) Antenna Max Value (dBc) Limit (dBc) Verdict NVNT BLE 1M 2402 Ant1 -56.37 -20 Pass NVNT BLE 1M 2480 Ant1 -54.7 -20 Pass Page 12 of 23 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Band Edge NVNT BLE 1M 2402MHz Ant1 Ref Band Edge NVNT BLE 1M 2402MHz Ant1 Emission Page 13 of 23 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Sh…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 34 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For Rapid Conn Inc Lumi Chill LED ice bucket speaker Test Model: Lumi-Chill Prepared for : Rapid Conn Inc Address : 25172 Arctic Ocean Drive #106, Lake Forest, CA-92630 Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : August 07, 2023 Number of tested samples : 2 Sample No. : A07143003-1, A07143003-2 Serial number : Prototype Date of Test : August 07, 2023 ~ August 14, 2023 Date of Report : August 14, 2023 Page 2 of 34 FCC ID: 2BBYR-LUMI-CHILL Report No.: LCSA07143003EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA07143003EA Date of Issue ................................... : August 14, 2023 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : Rapid Conn Inc Address ........................................... : 25172 Arctic Ocean Drive #106, Lake Forest, CA-92630 Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No. ................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. ........................... : Lumi Chill LED ice bucket speaker Trade Mark...................................... : LumiCharge Test Model ...................................... : Lumi-Chill Ratings ............................................ : Input: DC 5V, 1000mA DC 3.7V by Rechargeable Li-i…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Balaji Raghunathan(VP of Operations)
[email protected]949-637-9280Fax: 1-855-286-9267

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.20 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum peak conducted output power. The device can be installed at mixed portable/mobile exposure condition.