Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Oct 17, 2023
Application Purpose
Original Equipment
Date of Application
Oct 17, 2023
Equipment Note
Flik
Frequency Range
433.84600000 - 433.84600000
Company
Flicked LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FlikUserManual WelcometoFlik. GiveTheBird&WavetoDrivers Specifications: Dimension:L172*W108*H24mm Material:PC USB-CInput:5V0.5A USB-AtoCCable:1.5M 【REMOTECONTROLLED】:Withtheclickofabutton,youcancommunicatedriver feedbackinasafeandhilariousway.TheFLIKreplacesdangerousdriver communicationlikebrakechecking,yelling,etc..,workingdistance10M 【AUTOMATICBRIGHTNESSADJUSTMENT】:TheFLIKlightautomaticallyadjusts tobebrightduringthedayanddimatnight! 【EASYMOUNTING】:EasilyandsecurelymounttheFLIKanditsremotewiththe includedadhesiveVelcrostrips.Thehandlightattachestotheinteriorbackwindow whiletheremoteattachessafelytothedashboardortoyoukeychain.. 【PAIRING】:1sttimeuse,holdremote3safterinstallbattery 【BATTERY】:3-AAbatteriesareneededtopowerupthisdevice,remotewithbuiltin battery,CR2032 【CHARGING】:Chargingportonlychargeschargeablebattery 【MODEL】:toggletheswitchtochangebetweencarandofficemodel FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  -Reorient or relocate the receiving antenna.  -Increase the separation between the equipment and receiver.  -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  -Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Attestation Statements

Flicked LLC 8 The Green, Suite B, Dover, DE, 19901 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2023-10-11 To whom it may concern: We, Flicked LLC, hereby certify that the equipment for which authorization is sought (FCC ID: 2BC29- FLIK02) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Evan Tripp CEO Flicked LLC 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V03

Attestation Statements

Flicked LLC 8 The Green, Suite B, Dover, DE, 19901 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2023-10-11 U.S. Agent Designation Flicked LLC acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought FCC ID: 2BC29-FLIK02 Name and company of U.S. agent: Flicked LLC Physical U.S. address of agent: 8 The Green, Suite B, Dover, DE, 19901 FRN of U.S. agent: 0034293084 Email address of U.S. agent: [email protected] Flicked LLC acknowledges their obligation to accept service of process on behalf of Flicked LLC. Flicked LLC with the FRN [0034293084] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Evan Tripp CEO Flicked LLC Signature Tripp Evan CEO Flicked LLC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5 DocuSign Envelope ID: 8026674F-46B2-401F-B852-A48F852C4B5A

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2023-10-11> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2BC29-FLIK02 Flik 02 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. DocuSign Envelope ID: 8026674F-46B2-401F-B852-A48F852C4B5A Sincerely, Name/Title: Evan Tripp/CEO Company: Flicked LLC Address: 8 The Green, Suite B, Dover, DE, 19901 Phone: 00 1 (540) 846-1167 Fax: N/A E-Mail: [email protected] DocuSign Envelope ID: 8026674F-46B2-401F-B852-A48F852C4B5A

Cover Letter(s)

Flicked LLC 8 The Green, Suite B, Dover, DE, 19901 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2023-10-11 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2BC29-FLIK02 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Evan Tripp/CEO Company: Flicked LLC Address: 8 The Green, Suite B, Dover, DE, 19901 Phone: 00 1 (540) 846-1167 Fax: N/A E-Mail: [email protected] DocuSign Envelope ID: 8026674F-46B2-401F-B852-A48F852C4B5A

External Photos

FCC ID: 2BC29-FLIK02 TB-RF-074-1.0 Appendix III EUT External Photographs Photo 1 Appearance of EUT Photo 2 Appearance of EUT FCC ID: 2BC29-FLIK02 TB-RF-074-1.0 Photo 3 Appearance of EUT

ID Label/Location Info

FCC ID: 2BC29-FLIK02 TB-RF-074-1.0 Appendix IFCC ID Label Model No.: Flik 02 FCC ID: 2BC29-FLIK02 FCC ID: 2BC29-FLIK02 TB-RF-074-1.0 Appendix II ID Label Location ID LOCATION

Internal Photos

FCC ID: 2BC29-FLIK02 TB-RF-074-1.0 Appendix IV EUT Internal Photographs Photo 4 Internal of EUT Photo 5 Appearance of PCB Antenna FCC ID: 2BC29-FLIK02 TB-RF-074-1.0 Photo 6 Appearance of PCB

RF Exposure Info

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202309-0247-7 Page: 1 of 3 TB-RF-074-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 RF Exposure Evaluation FCC ID: 2BC29-FLIK02 1. Client Information Applicant : Flicked LLC Address : 8 The Green, Suite B, Dover, DE, 19901 Manufacturer : Flicked LLC Address : 8 The Green, Suite B, Dover, DE, 19901 2. General Description of EUT EUT Name : Flik HVIN/Model(s) No. : Flik 02 Model Different : ---- Product Description : Operation Frequency: 433.846 MHz Antenna Gain: PCB Antenna(1 dBi) Power Rating TX : DC CR2032 3V Power Rating RX Input: DC 5V DC 1.5V AA Rechargeable Li-ion battery Software Version : N/A Hardware Version : N/A Note: More test information about the EUT please refer the RF Test Report. Flipper Zero: Portable handheld electronic device featuring virtual pet, designed for education, development and prototyping of electronics and software. Report No.: TBR-C-202309-0247-7 Page: 2 of 3 TB-RF-074-1.0 The RF Exposure Evaluation for FCC: SAR Test Exclusion Calculations FCC: According to 447498 D04 Interim General RF Exposure Guidance v01. The SAR-based exemption formula of § 1.1307(b)(3)(i)(B), repeated here as Formula (B.2), applies for single fixed, mobile, and portable RF sources with available maximum time-averaged power or effective radiated power (ERP), whichever is greater, of less than or equal to the threshold P th (mW). This method shall only be used at separation distances from 0.5 cm to 40 cm and at frequencies from 0.3 GHz to 6 GHz (inclusive). P th is given by Formula (B.2). and f is in GHz, d is the separation distance (cm), and ERP 20cm is per Formula (B.1). The example values shown in Table B.2 are for illustration only. Table B.2—Example Power Thresholds (mW) Report No.: TBR-C-202309-0247-7 Page: 3 of 3 TB-RF-074-1.0 Calculation: Frequency (MHz) Max. Output Power (dBuV/m) Max. Output Power (dBm) Tolerance ± (dB) Output power (Max. Turn-up Procedure) (mW) Limit P th (mW) 433.846MHz 67.93 -22.63 -22±1 0.005 22 Note: For conducted measurements below 1000 MHz, the field strength shall be computed as specified in item d), and then an additional 4.7 dB shall be added as an upper bound on the field strength that would be observed on a test range with a ground plane for frequencies between 30 MHz and 1000 MHz, or an additional 6 dB shall be added for frequencies below 30 MHz. So: EIRP=E+20log3-104.8-(4.7 or 6) Note: At separation distance of ≤5 mm Conclusion: The measurement results comply with the FCC Limit per 47 CFR 2.1093 for the uncontrolled RF Exposure and SAR Exclusion Threshold per KDB 447498 v06. -----END OF REPORT-----

Test Report

URL:http://www.fengniaorf.com/ TEL:(0755)23227946??FAX:(0755)223227946-8005 specification applicant LCHSTAR ELECTRONICS CO.LTD type Antenna module on the system board project name 433 PCB Antenna versions 01 number 83040010078 Color Black DATE 2023/10/12 Antenna Layout & module on the system board frequency domain 433MHz±20Mhz characteristic impedance 50Ω standing-wave ratio (SWR) ≤2.0 polarization circular polarization gain 1dBi storage temperature -40°C~+85°C operating temperature -40°C~+85°C URL:http://www.fengniaorf.com/ TEL:(0755)23227946??FAX:(0755)223227946-8005 Laboratory test environment and equipment test item testing equipment S11、S12 、VSWR 、 LOSS network analyzer 8753E Efficiency 、 Gain 3D Radiation Pattern ETS 3Ddarkroom、8753E TRP、TIS ETS 3Ddarkroom、 CMW500 URL:http://www.fengniaorf.com/ TEL:(0755)23227946??FAX:(0755)223227946-8005 product drawing Inner conductor Outer conductor Jacket Insulation Specifications version number Revision date revised contents Revised 发行日期 date of issue A 2022.10.10 new increase Linda 2022.10.10 B 2022.10.20 revised Specification Format Joe 2022.10.20 C product description 1.1 This product is soft Teflon insulation series coaxial cable.Is suitable for the microwave equipment, wireless communication systems and equipment。 1.2 Product features : Excellent flexi-ability, good V.S.W.R, good shielding performance. Cable with data and structure diagram: 1.3 : structu re diagram

Test Report

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202309-0247-5 Page: 1 of 31 TB-RF-074-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 FCC Radio Test Report FCC ID: 2BC29-FLIK02 Report No. : TBR-C-202309-0247-5 Applicant : Flicked LLC Equipment Under Test (EUT) EUT Name : Flik Model No. : Flik 02 Series Model No. : ---- Brand Name : Flik Sample ID : HC-C-202309-0247-01-01-1#& HC-C-202309-0247-01-01-2# Receipt Date : 2023-09-26 Test Date : 2023-09-26 to 2023-10-10 Issue Date : 2023-10-10 Standards : FCC Part 15, Subpart C (15.231(a)) Test Method : ANSI C63.10:2013 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above, The EUT technically complies with the FCC requirements Test/Witness Engineer : Seven Wu Engineer Supervisor : Ivan Su Engineer Manager : Ray Lai This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202309-0247-5 Page: 2 of 31 TB-RF-074-1.0 Contents CONTENTS ............................................................................................................................................. 2 1. GENERAL INFORMATION ABOUT EUT ............................................................................. 5 1.1 Client Information ................................................................................................................. 5 1.2 General Description of EUT (Equipment Under Test) ................................................... 5 1.3 Block Diagram Showing the Configuration of System Tested ...................................... 6 1.4 Description of Support Units .............................................................................................. 6 1.5 Description of Test Mode .................................................................................................... 6 1.6 Description of Test Software Setting .............................................................................. 7 1.7 Measurement Uncertainty ................................................................................................ 7 1.8 Test Facility ........................................................................................................................ 8 2. TEST SUMMARY ....................................................................................................................... 9 3. TEST SOFTWARE ..................................................................................................................... 9 4. TEST EQUIPMENT .................................................................................................................. 10 5. CONDUCTED EMISSION TEST ........................................................................................... 12 5.1 Test Standard and Limit .................................................................................................... 12 5.2 Test Setup ........................................................................................................................... 12 5.3 Test Procedure ................................................................................................................... 13 5.4 Deviation From Test Standard ......................................................................................... 13 5.5 Test Data ............................................................................................................................. 13 6. RADIATED EMISSION TEST ................................................................................................ 14 6.1 Test Standard and Limit .................................................................................................... 14 6.2 Test Setup ........................................................................................................................... 15 6.3 Test Procedure ................................................................................................................... 17 6.4 Deviation From Test Standard ......................................................................................... 17 6.5 EUT Operating Condition ................................................................................................. 17 6.6 Test Data ............................................................................................................................. 17 7. BANDWIDTH ............................................................................................................................ 18 7.1 Test Standard and Limit .................................................................................................... 18 7.2 Test Setup ........................................................................................................................... 18 7.3 Test Procedure ................................................................................................................... 18 7.4 Deviation From Test Standard ......................................................................................... 18 7.5 EUT Operating Condition ................................................................................................. 18 7.6 Test Data ............................................................................................................................. 18 Report No.: TBR-C-202309-0247-5 Page: 3 of 31 TB-RF-074-1.0 8. RELEASE TIME MEASUREMENT ....................................................................................... 19 8.1 Test Standard and Limit .................................................................................................... 19 8.2 Test Setup ......…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2BC29-FLIK02 TB-RF-074-1.0 Appendix V EUT Test Photographs 15C Test Setup Photo of Setup for Radiated Emission (Above 1 GHz) Photo of Setup for Radiated Emission (Below 1 GHz) -----EN D OF REPORT-----

Contact Information

Applicant

Evan Tripp
[email protected]00 1 (540) 846-1167Fax: /

Test Firm

Shenzhen Toby Technology Co., Ltd.Ray Lai
[email protected]---

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.846 MHz - 433.846 MHz-
Confidentiality
Long Term