FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Enping Kyle Audio Equipment Factory/
  3. 2BC2N-SEM200

2BC2N-SEM200Wireless monitoring system

Enping Kyle Audio Equipment Factory
Wireless monitoring system - FCC ID 2BC2N-SEM200 - Enping Kyle Audio Equipment Factory
Click to zoom

Application Details

Equipment Class
DWM - Part 15 Wireless Microphone
Date of Grant
Apr 06, 2024
Application Purpose
Original Equipment
Date of Application
Apr 06, 2024
Equipment Note
Wireless monitoring system
Frequency Range
530.00000000 - 595.00000000
Company
Enping Kyle Audio Equipment Factory
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

530-595MHz 530-595MHz 530-595MHz NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation -- Consult the dealer or an experienced radio/TV technician for help. Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Attestation Statements

EnpingKyleAudioEquipmentFactory 2024/4/01 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:AttestationStatementsPart2.911(d)(5)(i)requestfor2BC2N-SEM200 [EnpingKyleAudioEquipmentFactory](“theapplicant”)certifiesthattheequipmentfor whichauthorizationissoughtisnot“covered”equipmentprohibitedfromreceivingan equipmentauthorizationpursuanttosection2.903oftheFCCrules. Sincerely, (Applicantsignature) (Applicantprintedname)chunboHuang EnpingKyleAudioEquipmentFactory 2024/4/01 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:AttestationStatementsPart2.911(d)(5)(ii)requestfor2BC2N-SEM200 [EnpingKyleAudioEquipmentFactory](“theapplicant”)certifiesthat,asofthedateof thefilingoftheapplication,theapplicantisnotidentifiedontheCoveredListasan entityproducing“covered”equipment. Sincerely, (Applicantsignature) (Applicantprintedname)chunboHuang

Cover Letter(s)

EnpingKyleAudioEquipmentFactory ProductSimilarityDeclaration EUTDescription:Wirelessmonitoringsystem ModelNo.:SEM200,SEM100,SEM100-1,SEM100-2,SEM200-1,SEM200- 2,SEM400,SEM600,SEM800,SEM1100,SEM2200,SEM2400,SEM2040, SEM2060,SEM4400,SEM4040,SEM2600,SEM2080,SEM2080-2,SEM2080- 4,SEM2080-6,SEM2080-8,SEM2080-10,SEM2800,AR1100,AR1100-1, AR1100-2,AR2200,AR2200-1,AR2200-2,AR200,AR400,AR600,AR800, AR2040,AR2060,AR2080,AR2080-2,AR2080-4,AR2080-6,AR2080-8, AR2080-10,AR2090,AR2090-2,AR2090-4,AR2090-6,AR2090-8,AR2090-10, ER2090,ER2090-2,ER2090-4,ER2090-6,ER2090-8,ER2090-10,SEM2090, SEM2090-2,SEM2090-4,SEM2090-6,SEM2090-8,SEM2090-10,AR200, AR100,AR400,AR600,AR800,AR100,ER100,ER200,ER400,ER600, ER2020,ER2040,ER2060,ER2080,ER1100,ER1200,AR1200,SEM1200, AR404,ER404,SEM404,AR440,ER440,SEM440,SR200,SR100,SR400, SR600,SR800,SR1100,SR2090,SR2080,SR2080-2,SR2080-4,SR2080-6, SR2080-8,SR2080-10,SR2040,SR2060,SR2200,TFT-S4,TFT-S4-2, TFT-S4-4,TFT-S4-6,TFT-S4-8,TFT-S4-10,DS100,DS100-2,DS100-4, DS100-6,DS100-8,DS100-10,DS200,DS200-2,DS200-4,DS200-6,DS200-8, DS200-10 FCCID:2BC2N-SEM200 We(EnpingKyleAudioEquipmentFactory)herebystatethatall themodelsareelectricalidenticalincludingthesamesoftware parameterandhardwaredesign(i.e.,circuitdesign,PCBLayout, RFmodule/circuit,antennatype(s)andantennalocation, componentsonPCB,etc.,),samemechanicalstructureand design(includingproductenclosure,materials,etc.,),theonly differenceisthemodelname. Signature: Name:chunboHuang Title:Manager Place,date:Apr01,2024

Cover Letter(s)

EnpingKyleAudioEquipmentFactory (2024/4/01) EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:CONFIDENTIALITYREQUESTFOR EUTNAME:Wirelessmonitoringsystem MODEL:SEM200,SEM100,SEM100-1,SEM100-2,SEM200-1,SEM200-2,SEM400, SEM600,SEM800,SEM1100,SEM2200,SEM2400,SEM2040,SEM2060,SEM4400, SEM4040,SEM2600,SEM2080,SEM2080-2,SEM2080-4,SEM2080-6,SEM2080-8, SEM2080-10,SEM2800,AR1100,AR1100-1,AR1100-2,AR2200,AR2200-1, AR2200-2,AR200,AR400,AR600,AR800,AR2040,AR2060,AR2080,AR2080-2, AR2080-4,AR2080-6,AR2080-8,AR2080-10,AR2090,AR2090-2,AR2090-4, AR2090-6,AR2090-8,AR2090-10,ER2090,ER2090-2,ER2090-4,ER2090-6, ER2090-8,ER2090-10,SEM2090,SEM2090-2,SEM2090-4,SEM2090-6,SEM2090-8, SEM2090-10,AR200,AR100,AR400,AR600,AR800,AR100,ER100,ER200,ER400, ER600,ER2020,ER2040,ER2060,ER2080,ER1100,ER1200,AR1200,SEM1200, AR404,ER404,SEM404,AR440,ER440,SEM440,SR200,SR100,SR400,SR600, SR800,SR1100,SR2090,SR2080,SR2080-2,SR2080-4,SR2080-6,SR2080-8,SR2080-10, SR2040,SR2060,SR2200,TFT-S4,TFT-S4-2,TFT-S4-4,TFT-S4-6,TFT-S4-8,TFT-S4-10, DS100,DS100-2,DS100-4,DS100-6,DS100-8,DS100-10,DS200,DS200-2,DS200-4, DS200-6,DS200-8,DS200-10 FCCID:2BC2N-SEM200 ToWhomItMayConcern: Thisletterservesasanofficialrequestforconfidentialityundersections0.457and0.459 ofCFR47.Wehaverequestedthatthe(listtheitemsthatarebeingrequestedfor confidentialityhere)requiredtobesubmittedwiththisapplicationbepermanently withheldfrompublicreview. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselectedabove arewithheldfrompublicviewforaperiodof______daysfromthedateoftheGrantof EquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Pleasecontactmeifthereisanyinformationyoumayneed. Sincerely, (Applicantsignature) (Applicantprintedname)chunboHuang Mustbesignedbytheapplicantcontactcitedastechnicalornon-technicalcontactonthe 731formprovidedtoEurofinsMETLabs,orbytheauthorizedagentifanappropriate authorizedagentletterhasbeenprovided.Letterssignedbytheapplicantshouldbe placedonapplicantletterhead.

Cover Letter(s)

EnpingKyleAudioEquipmentFactory (2024/4/01) EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:LETTEROFAGENTAUTHORIZATION ToWhomItMayConcern: We,theundersigned,herebyauthorize(FluxComplianceServiceLaboratory)toactonourbehalf inallmattersrelatingtoapplicationforequipmentauthorization,includingthesigningofall documentsrelatingtothesematters. Wealsoherebycertifythatnopartytotheapplicationauthorizedhereunderissubjecttothe denialofbenefits,includingFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseAct of1988,21U.S.C.853(a). Thisagreementexpiresoneyearfromthecurrentdate. Sincerely, (Applicantsignature) (Applicantprintedname)chunboHuang Mustbesignedbytheapplicantcontactcitedastechnicalornon-technicalcontactonthe 731formprovidedtoEurofinsMETLabs,orbytheauthorizedagentifanappropriate authorizedagentletterhasbeenprovided.Letterssignedbytheapplicantshouldbe placedonapplicantletterhead.

External Photos

Page 1 of 4ReportNo.:FCS202403246 Ex ternalphotos Photo1 Photo2 Page 2 of 4ReportNo.:FCS202403246 Photo3 Photo4 Page 3 of 4ReportNo.:FCS202403246 Photo5 Photo6 Page 4 of 4ReportNo.:FCS202403246 Photo7

ID Label/Location Info

LabelandLabelLocation FCCID:2BC2N-SEM200

Internal Photos

Page1of5ReportNo.:FCS202403246 Internalphotos Photo1 Photo2 Page2of5ReportNo.:FCS202403246 Photo3 Photo4 Page3of5ReportNo.:FCS202403246 Photo5 Photo6 Page4of5ReportNo.:FCS202403246 Photo7 Photo8 Page5of5ReportNo.:FCS202403246 Photo9 ANT

RF Exposure Info

Page1of2ReportNo.:FCS202403246W02 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com FCCRFExposure EUTDescription:Wirelessmonitoringsystem ModelNo.:SEM200,SEM100,SEM100-1,SEM100-2,SEM200-1,SEM200-2,SEM400,SEM600,SEM800, SEM1100,SEM2200,SEM2400,SEM2040,SEM2060,SEM4400,SEM4040,SEM2600,SEM2080,SEM2080-2, SEM2080-4,SEM2080-6,SEM2080-8,SEM2080-10,SEM2800,AR1100,AR1100-1,AR1100-2,AR2200, AR2200-1,AR2200-2,AR200,AR400,AR600,AR800,AR2040,AR2060,AR2080,AR2080-2,AR2080-4, AR2080-6,AR2080-8,AR2080-10,AR2090,AR2090-2,AR2090-4,AR2090-6,AR2090-8,AR2090-10,ER2090, ER2090-2,ER2090-4,ER2090-6,ER2090-8,ER2090-10,SEM2090,SEM2090-2,SEM2090-4,SEM2090-6, SEM2090-8,SEM2090-10,AR200,AR100,AR400,AR600,AR800,AR100,ER100,ER200,ER400,ER600,ER2020, ER2040,ER2060,ER2080,ER1100,ER1200,AR1200,SEM1200,AR404,ER404,SEM404,AR440,ER440,SEM440, SR200,SR100,SR400,SR600,SR800,SR1100,SR2090,SR2080,SR2080-2,SR2080-4,SR2080-6,SR2080-8, SR2080-10,SR2040,SR2060,SR2200,TFT-S4,TFT-S4-2,TFT-S4-4,TFT-S4-6,TFT-S4-8,TFT-S4-10,DS100,DS100-2, DS100-4,DS100-6,DS100-8,DS100-10,DS200,DS200-2,DS200-4,DS200-6,DS200-8,DS200-10 FCCID:2BC2N-SEM200 Equipmenttype:mobileequipment 1.Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhuman exposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) F=frequencyinMHz Formula:Pd=(P out *G)/(4*π*r 2 ) Where: Pd=powerdensityinmW/cm 2 , Pout=outputpowertoantennainmW; Page2of2ReportNo.:FCS202403246W02 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com G=gainofantennainlinearscale, π=3.14; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm2.Ifweknowthemaximumgainoftheantennaandthetotalpower inputtotheantenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitis reached. 2.TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. 3.TestResultofRFExposureEvaluation ANT1 CH/Frequency Outputpower(dBm/mW) Channel01 530.10MHz 5.58/3.61 Outputpower (dBm/mW) Antenna Gain(dBi) PowerDensity atR=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result ANT1 5.58/3.612.50.001281.0Pass Conclusion:NoSARisrequired

Test Report

专业天线服务商 深圳市飞敏科技有限公司 SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. 项目型号 P96 天线型号 测 试 魏月娥 审 核 夏兴喜 日 期 2022-08-29 天线测试报告 Antenna test report SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. TEL:0755-23035723 Mail:[email protected] URL:www.fmant.cn 测试设备和测试环境 Test equipment and test environment SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. TEL:0755-23035723 Mail:[email protected] URL:www.fmant.cn 测试设备 Test equipment 无源指标 增益 效率 3D方向图 有源指标 TRP总辐射功率 TIS总接收灵敏度 探头微波暗室 频率:0.4GHz至6GHz 主要测试指标 SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. TEL:0755-23035723 Mail:[email protected] URL:www.fmant.cn 测试设备 Test equipment Agilent E5071C矢量网络分析仪 频率:300 kHz至8.5GHz R&S CMW500 宽带无线通信测试仪 GSM/3G/4G WIFI/ Bluetooth NB-IoT SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. TEL:0755-23035723 Mail:[email protected] URL:www.fmant.cn R=5mm L=262mm 天线增益与效率 Antenna gain and efficiency SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. TEL:0755-23035723 Mail:[email protected] URL:www.fmant.cn 天线 Freq(MHz) Efficiency (%) Gian(dBi) 530 MHz 15.67 53 1.19 5 MHz 14.83 54 1.17 0 MHz 14.14 54 1.24 5 MHz 16.41 55 1.53 0 MHz 18.13 55 1.09 5 MHz 15.75 56 1.71 0 MHz 13.69 56 1.40 5 MHz 11.57 57 2.23 0 MHz 10.37 57 1.89 5 MHz 9.25 58 2.34 0 MHz 8.74 2.50 585 MHz 590 MHz 595 MHz 8. 8. 8.12 36 24 1.33 1.47 1.88 插入图片2 插入图片3 插入图片4 天线辐射方向图 Antenna Radiation Pattern SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. TEL:0755-23035723 Mail:[email protected] URL:www.fmant.cn 深圳市宝安区西乡固戍恒南一路C栋303 TEL:(86)755-23035723. FAX:0755-23036702 E-mail:[email protected] ADD: 303,building C,GUSHU Hengnan Road,Xixiang,Baoan district Shenzhen Thanks for your support! 感谢您的支持!

Test Report

FCCTestReport ReportNo:FCS202403246W01 Issuedfor Applicant: EnpingKyleAudioEquipmentFactory Address: 4thFloor,Building1,Building2,Jiangnan10thStreet,Dong'an Town,EnpingCity ProductName: Wirelessmonitoringsystem BrandName: N/A ModelName: SEM200 SeriesModel: SEM100,SEM100-1,SEM100-2,SEM200-1,SEM200-2,SEM400, SEM600,SEM800,SEM1100,SEM2200,SEM2400,SEM2040, SEM2060,SEM4400,SEM4040,SEM2600,SEM2080,SEM2080-2, SEM2080-4,SEM2080-6,SEM2080-8,SEM2080-10,SEM2800, AR1100,AR1100-1,AR1100-2,AR2200,AR2200-1,AR2200-2, AR200,AR400,AR600,AR800,AR2040,AR2060,AR2080,AR2080-2, AR2080-4,AR2080-6,AR2080-8,AR2080-10,AR2090,AR2090-2, AR2090-4,AR2090-6,AR2090-8,AR2090-10,ER2090,ER2090-2, ER2090-4,ER2090-6,ER2090-8,ER2090-10,SEM2090,SEM2090-2, SEM2090-4,SEM2090-6,SEM2090-8,SEM2090-10,AR200,AR100, AR400,AR600,AR800,AR100,ER100,ER200,ER400,ER600, ER2020,ER2040,ER2060,ER2080,ER1100,ER1200,AR1200, SEM1200,AR404,ER404,SEM404,AR440,ER440,SEM440,SR200, SR100,SR400,SR600,SR800,SR1100,SR2090,SR2080,SR2080-2, SR2080-4,SR2080-6,SR2080-8,SR2080-10,SR2040,SR2060, SR2200,TFT-S4,TFT-S4-2,TFT-S4-4,TFT-S4-6,TFT-S4-8, TFT-S4-10,DS100,DS100-2,DS100-4,DS100-6,DS100-8,DS100-10, DS200,DS200-2,DS200-4,DS200-6,DS200-8,DS200-10 FCCID: 2BC2N-SEM200 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial, SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Page2of30ReportNo.:FCS202403246W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TESTRESULTCERTIFICATION Applicant’sName ...................... :EnpingKyleAudioEquipmentFactory Address ...................................... : 4thFloor,Building1,Building2,Jiangnan10thStreet,Dong'an Town,EnpingCity Manufacture'sName................:EnpingKyleAudioEquipmentFactory Address ...................................... : 4thFloor,Building1,Building2,Jiangnan10thStreet,Dong'an Town,EnpingCity ProductDescription ProductName ........................... :Wirelessmonitoringsystem BrandName.............................:N/A ModelName .............................. :SEM200 SeriesModel..............................:Seepageoneofthereport TestStandards .......................... :FCCRulesandRegulationsPart15SubpartCsection15.236 TestProcedure..........................:ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedFCS,thetestresultsshowthattheequipmentundertest (EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFCS,thisdocument maybealteredorrevisedbyFCS,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest..................................: Date(s)ofperformanceoftests . :Mar15,2024~Mar25,2024 DateofIssue ................................. :Mar25,2024 TestResult.....................................:Pass Testedby: (ScottShen) Reviewedby : (DukeQian) Approvedby: (JackWang) Page3of30ReportNo.:FCS202403246W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TableofContents Page 1.SUMMARYOFTESTRESULTS..............................................................................................6 1.1TESTFACTORY................................................................................................................7 1.2MEASUREMENTUNCERTAINTY.....................................................................................7 2.GENERALINFORMATION.......................................................................................................8 2.1GENERALDESCRIPTIONOFTHEEUT..........................................................................8 2.2DESCRIPTIONOFTHETESTMODES..........................................................................10 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS.................11 2.4EQUIPMENTSLIST.........................................................................................................12 3.CONDUCTEDEMISSIONMEASUREMENT.........................................................................13 3.2TESTPROCEDURE........................................................................................................13 3.3TESTSETUP...................................................................................................................14 3.4TESTRESULTS...............................................................................................................15 4MAXIMUMRADIATEDPOWER..............................................................................................17 4.1LIMIT................................................................................................................................17 4.2TESTPROCEDURE........................................................................................................17 3.3TESTSETUP...................................................................................................................17 4.4TESTRESULTS...............................................................................................................17 5.OCCUPIEDBANDWIDTH......................................................................................................18 5.1LIMIT......................................................................................................................................18 5.2TESTPROCEDURE........................................................................................................18 5.3TESTSETUP...................................................................................................................18 5.4TESTRESULTS...............................................................................................................19 6.NECESSARYBANDWITH...................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page1of2ReportNo.:FCS202403246 RE Page2of2ReportNo.:FCS202403246 CE

Contact Information

Applicant

chunbo Huang(Manager)
[email protected]13824097035Fax: 13824097035

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]13510297284

Technical Specifications

#Rule PartsFrequency RangePower Output
115C530 MHz - 595 MHz-
Confidentiality
Long Term

Other Applications from Enping Kyle Audio Equipment Factory

Wireless microphone - FCC ID 2BC2N-T9 - Enping Kyle Audio Equipment Factory
2BC2N-T9

Wireless microphone

Nov 01, 2023

Equipment Class

DWM - Part 15 Wireless Microphone