Application Details

Equipment Class
JAB - Part 15 Class B Digital Device
Date of Grant
Dec 19, 2023
Application Purpose
Original Equipment
Date of Application
Dec 19, 2023
Equipment Note
LED display
Company
Targa GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Page 1 07.11.2023 Installation Guide: Targa LED Cashier Addon Display Sign i- this document online Page 2 10 (Form A) M5x8 3,9x13 1 X 1 X 1 X 1 X 1 X 2 X Ø 10mm Ø 5,5mm * Credits/Refererence:* Image: Flaticon.com ́. This cover was created using resources from Flaticon.com. Page 3 right left Credits/Refererence:* Image: Flaticon.com ́. This cover was created using resources from Flaticon.com. Page 4 * 1 2 Option A Option B Credits/Refererence:* Image: Flaticon.com ́. This cover was created using resources from Flaticon.com. * 3.9 x 13 mm Self-tapping screw screw in 10mm 3 mm distance +- 0,05 mm manual fine adjustment Page 5 3 4 Page 6 5 6 Page 7 7 Optional: Reinigung Acryl - Glas / Cleaning Acryl - Glas 8 Handlungsanweisung Acryl – Glas / General Handling Instruction Acryl Glas Deutsch English Acrylglas sollten Sie niemals trocken abwischen. Dadurch können Kratzer an der Oberfläche entstehen. Außerdem lädt sich die Acryl - Platte elektrostatisch auf und zieht Staub an. Acrylic glass should never be wiped dry. This may cause scratches on the surface. Also, the acrylic - sheet becomes electrostatically charged and attracts dust. Das Mikrofasertuch sollte frei von jedweder Verschmutzung sein. The microfiber cloth should be free of any dirt. Credits/Refererence:* Image: Flaticon.com ́. This cover was created using resources from Flaticon.com. * Page 8 Die Reinigung der Fläche sollte immer mit einem nebelfeuchtem Mikrofasertuch erfolgen. However, the surface should always be cleaned with a damp microfiber cloth. Erst senkrecht wischen, dann waagerecht. Keine kreisenden Bewegungen. First wipe vertically, then horizontally. No circular movements Restfeuchte zwecks Antistatik-Filmbildung abtrocknen lassen. Nicht nachreiben! Allow residual moisture to dry off to form an antistatic film. Do not rub! Technical Specification Description Dimension /(Quantity) Material Weight [g] Profile 142x40x14,5mm Aluminum 260,3 Display 272x125x8mm PMMA 325,0 Input Power/ Amperage Cable Plug 24V ⎓ PS2 according to EN 62368-1 ≤ 1,5W/62mA AWM Style 20276/4m RJ10 4P4C Cash register sign: (RJ10 4P4C) Page 9 Product marking: Attachment FCC HINTS FCC hints This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/ TV technician for help. Page 10

Users Manual

Page 1 06.12.2023 i- this document online Installation Guide: Targa LED Cashier Main Display Sign TKD-SBES-MD-IGB Page 2 * 10 (Form A) M5x8 3,9x13 Ø 10mm Ø 5,5mm Credits/Refererence:* Image: Flaticon.com ́. This cover was created using resources from Flaticon.com. Page 3 For more informations: see attachment right left Cable channel Cashier display 2200mm Credits/Refererence:* Image: Flaticon.com ́. This cover was created using resources from Flaticon.com. Page 4 1 2 Option A Option B * 3.9 x 13 mm Self-tapping screw screw in 10mm 3 mm distance +- 0,05 mm manual fine adjustment Opition A Opition B Credits/Refererence:* Image: Flaticon.com ́. This cover was created using resources from Flaticon.com. Page 5 3 4 * Credits/Refererence:* Image: Flaticon.com ́. This cover was created using resources from Flaticon.com. Page 6 5 6 Page 7 7 Optional: Reinigung Acryl – Glas / Cleaning Acryl - Glas 8 Handlungsanweisung Acrylglas + Aluminiumprofil / General Handling Instruction acryl glass + aluminium profile Deutsch English Acrylglas sollten Sie niemals trocken abwischen. Dadurch können Kratzer an der Oberfläche entstehen. Außerdem lädt sich die Acryl - Platte elektrostatisch auf und zieht Staub an. Acrylic glass should never be wiped dry. This may cause scratches on the surface. Also, the acrylic - sheet becomes electrostatically charged and attracts dust. Das Mikrofasertuch sollte frei von jedweder Verschmutzung sein. The microfiber cloth should be free of any dirt. Die Reinigung der Fläche sollte immer mit einem nebelfeuchtem Mikrofasertuch erfolgen. However, the surface should always be cleaned with a damp microfiber cloth. Erst senkrecht wischen, dann waagerecht. Keine kreisenden Bewegungen. First wipe vertically, then horizontally. No circular movements Restfeuchte zwecks Antistatik-Filmbildung abtrocknen lassen. Nicht nachreiben! Allow residual moisture to dry off to form an antistatic film. Do not rub! Credits/Refererence:* Image: Flaticon.com ́. This cover was created using resources from Flaticon.com. Page 8 Technical Specification Description Dimension /(Quantity) Material Weight [g] Profile 261x40x14,5mm Aluminum 279,1 Display 272x250x8mm PMMA 645,0 Input Power/ Amperage Cable Plug 24V ⎓ PS2 according to EN 62368-1 ≤ 1,5W/62mA ≤ 2,0W/82mA AWM Style 20276/4m RJ 10 4P4C Cash register sign: Page 9 Product marking: Page 10 Attachment FCC HINTS FCC hints This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/ TV technician for help. Page 11 Attachment Page 12

Attestation Statements

TARGA GmbH, Coesterweg 45, D-59494 Soest, Germany Form: RFT-AMER-TCB-OP-19n Revision: 1 Page 1 of 1 Date: 1/25/2023 Attention: Application Examiner Re: Covered List, located at https://www.fcc.gov/supplychain/coveredlist and 47 CFR parts §2.903 and §2.911(d)(5)(ii) of the FCC rules Applicant: TARGA GmbH, Coesterweg 45, D-59494 Soest, Germany FCC ID: 2BC5E-TKD-SBES To whom it may concern, [Insert company/applicant name] (“Applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to 47 CFR part §2.903 of the FCC rules and does not originate directly or indirectly from any company named on the covered list located in the link above or any subsidiary or affiliate thereof. Applicant further certifies that, as of the date of the filing of the application, the Applicant is not identified on the Covered List as an entity producing “covered” equipment and is not a subsidiary or affiliate of any such entity pursuant to 47 CFR part §1.50002 and required by 47 CFR part §2.911(d)(5)(ii) of the FCC rules. I HEREBY CERTIFY THAT I am authorized to make the representations above on behalf of the Applicant and agree to immediately notify Intertek if there is any change in the status identified above. Mike Decker executive director TARGA GmbH, Coesterweg 45, D-59494 Soest, Germany 2023-12-19

Cover Letter(s)

TARGA GmbH Registergericht / Geschäftsführer/ tel. +49 (29 21) 380 38-0 Coesterweg 45 Trade Register Arnsberg Managing Directors fax +49 (29 21) 380 38-90 D-59494 Soest HRB 12035 Matthias Klauke internet: Germany Ust.ID Nr. DE815741416 Andreas Brinkmann www.targa.gmbh WEEE-Reg.-Nr. DE 83403208 Dr. Domenico Jahn www.targa.de mail: [email protected] 12/13/2023 Intertek Testing Services NA Ltd. 70 Codman Hill Road Boxborough, MA 01719 Subject: Limited Agency Agreement TARGA GmbH FCC ID: 2BC5E-TKD-SBES To Whom It May Concern: We, TARGA GmbH, hereby authorized Mr. Dressler of Intertek to act as our Agent for the purpose of preparing application for FCC ID number 2BC5E-TKD-SBES under all applicable parts of the FCC rules and regulations. The effective date of this limited agency agreement is 12/13/2023. The Limited Agency Agreement expires on 03/31/2024, unless sooner terminated or extended by written notice to Intertek Testing Services and the Federal Communications Commission. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. The applicant is not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 U.S.C. 862, and no party to the application is subject to a denial of federal benefits pursuant to that section. If you have any questions or comments, please do not hesitate to contact me. Sincerely, Mike Decker Executive Director TARGA GmbH Seite 2 von 2

Cover Letter(s)

1(1) TARGA GmbH Coesterweg 45 59494 Soest Deutschland 12/13/2023 Attention: Application Examiner RE: Request for Confidentiality Applicant: TARGA GmbH FCC ID: 2BC5E-TKD-SBES To Whom It May Concern: Permanent Confidentiality Request is hereby submitted by TARGA GmbH to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: • Schematics • Detailed Block Diagrams • Detailed Operational/Functional Description Rationale for request for confidentiality: TARGA GmbH has invested considerable time and materials in research and development to produce the referenced product. If you have questions or need further information, please contact the undersigned. Sincerely, Mike Decker Executive Director TARGA GmbH

External Photos

EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPA-52190-A1-Pictures Anlage (Addendum) 5 2/9 Dokumentation des Prüflings (Documentation of the EUT) TKD-SBES-MD-APC

ID Label/Location Info

TKD-SBES-AOD-APC TARGA GmbH Coesterweg 45 59494 Soest GERMANY WEEE: Input: 24V XX/23 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ---------------------------------------------- FCC ID: 2BC5E-TKD-SBES

ID Label/Location Info

TKD-SBES-MD-APC TARGA GmbH Coesterweg 45 59494 Soest GERMANY WEEE: Input: 24V XX/23 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ---------------------------------------------- FCC ID: 2BC5E-TKD-SBES

Internal Photos

EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPA-52190-A1-Pictures Anlage (Addendum) 5 3/9 Dokumentation des Prüflings (Documentation of the EUT) TKD-SBES-AOD-APC EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPA-52190-A1-Pictures Anlage (Addendum) 5 4/9 Dokumentation des Prüflings (Documentation of the EUT)

Test Report

EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPB-52190-A1 2/23 1. Zusammenfassung der Ergebnisse, Emission (Summary of Results, emission) Messverfahren (Measurement) Norm (Standard) Ergebnis (Result) *1 P F NA NP RES Messung der Funkstörspannung am Netzübergabepunkt im Frequenzbereich von 150 kHz - 30 MHz (Measurement of the interference voltage (line conduction test) in the frequency range from 150 kHz up to 30 MHz) FCC PART 15, Subpart B, Class B §15.107 (47 CFR 15) ☒ 1 Messung der Funkstörfeldstärke im Frequenzbereich von 30 MHz - 1000 MHz (Measurement of the radiated interference in the frequency range from 30 MHz up to 1000 MHz) FCC PART 15, Subpart B, Class B §15.109 (47 CFR 15) ☒ 2 Messung der Funkstörfeldstärke im Frequenzbereich oberhalb 1000 MHz (Measurement of the radiated interference in the frequency above 1000 MHz) FCC PART 15, Subpart B, Class B §15.109 (47 CFR 15) ☒ 3 *1 P = erfüllt (pass) F = nicht erfüllt (fail) NA = nicht zutreffend (not applicable) NP = nicht durchgeführt auf Wunsch des Auftraggebers (not performed by request of the applicant) RES = Ergebnisse siehe in Anlage (results see in addendum) Bemerkungen (Remarks): ☒ Weitere Anlagen: Verwendete Leitungen : ☒ Bewertungskriterien : ☒ Dokumentation Prüfling : ☒ Dokumentation Aufbau : ☒ Messunsicherheit : ☒ (ohne Funktion) Messgeräteliste : ☒ ☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐☐ EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPB-52190-A1 3/23 2. Generelle Informationen zum Prüfling (General Information of the EUT): Bezeichnung des Prüfobjektes: LED Kassendisplay (Type of appliance) (LED cash register display) Schutzklasse des Prüflings: III (Protection class of the EUT) Mitgeliefertes Zubehör: (Submitted accessories) () Bedienungsanleitung mitgeliefert: Nein Relevante Einschränkung durch die Bedienungsanleitung: - (User manual supplied) (No) (Relevant limitation through the user manual) (-) Spezielle Bemerkungen zum Prüfling: - (Special remarks to the EUT) - Art des Gerätes: Tischgerät Der Prüfling verfügt über ein berührungsempfindliches Display: Nein (Type of EUT) (Table-top equipment) (EUT includes a touch-screen) (No) Versorgungsspannung: 120 V / 60 Hz (Mains voltage) Höchste interne Taktfrequenz: Keine Taktfrequenz vorhanden* (Highest internal frequency) (No clock frequency available)* * Vom Hersteller erklärt (Declared by the applicant) EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPB-52190-A1 4/23 3. Raum für zusätzliche Erläuterungen (Room for additional declarations): Verwendete Betriebszustände / Testprogramme: No. Beschreibung (Description) 1 1.Zahl rot; 2. Zahl grün, Zusatz blau (1. Number red, 2. number green, addition blue) 2 1.Zahl rot (1. Number red) 3 2.Zahl rot , Zusatz rot (2. Number red, addition red) 4 1.Zahl rot, 2. Zahl rot, Zusatz rot (1.Number red, 2. number red, addition red) (Used operation modes / test programs) Auflösung des Displays: - (Resolution of the display) Auslastung der Telekommunikationsschnittstelle, falls zutreffend: - Verwendetes Betriebssystem: (Used operating system) - (Load of the telecommunication ports, if applicable) Simulatoren, von OBL zur Verfügung gestellt: Netzteil OMRON S8PS-05024C (Powersupply OMRON S8PS-05024C) (Simulators, provided by OBL) Verschärfte Kundenanforderungen: Die Prüfungen wurden auf Kundenwunsch zusätzlich zu den normativen Anforderungen mit folgenden verschärften Anforderungen durchgeführt. (On request of the applicant the tests were carried out in addition to the normative requests with following tightened requirements.) ☒ Störaussendungen (Emission) Zutreffend (applicable) 5 dB unter dem normativen Grenzwert (5 dB under the normative Limit) Nicht zutreffend (not applicable) Zutreffend (applicable) 6 dB unter dem normativen Grenzwert (6 dB under the normative Limit) Nicht zutreffend (not applicable) (Tightened customer requirements) Bemerkung (Remark): - EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPB-52190-A1 5/23 4. Erklärung zur Übersetzung Deutsch / Englisch (Declaration regarding the translation German / English): Dieser Prüfbericht wurde von deutscher Sprache in englische Sprache übersetzt. Im Falle eines Zweifels an der Formulierung zählt die deutsche Version. (This Test Report was translated from German to English language. In case of doubt the German version shall prevail.) 5. Erklärung zu den Kürzeln der Prüfer (Declaration regarding the short forms of the test engineers): Kürzel (short form) = Prüfer (test engineer) ck = Christian Klostermann fh = Frank Huncke bb = Sascha Bierbaum mw = M. H. Wilke 6. Klimatische Bedingungen (Climatic conditions): Temperatur (temperature) : 15 °C - 35 °C Luftfeuchte (humidity) : 30 % - 60 % Luftdruck (atmospheric pressure) : 860 hPa – 1060 hPa Für die klimatischen Bedingungen während der Funkstörfeldstärkemessung siehe Anhang 2 und 3. (For climatic conditions during the radiated emission test see addendum 2 and 3.) EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPB-52190-A1 6/23 | | | | | | | 7. Allgemeine Angaben (General declarations): Absender der Lieferung: Targa GmbH Coesterweg 45 59494 Soest Deutschland / Germany (Sender of the delivery) Prüflabor und Prüfort: Obering. Berg & Lukowiak GmbH Löhner Straße 157 32609 Hüllhorst Deutschland / Germany (Test Laboratory and Place) Angaben zur Akkreditierung des Prüflabors: Durch die DAkkS nach DIN EN ISO/IEC 17025 : 2018 akkreditiertes Prüflabor. Die Akkreditierung gilt nur für den in der Urkundenanlage D-PL-12032-01-02 aufgeführten Akkreditierungsumfang. Die Deutsche Akkreditierungsstelle GmbH ist Unterzeichner der Multilateralen Abkommen von EA, ILAC und IAF zur gegenseitigen Anerkennung. (Testing laboratory accredited by DAkkS according to DIN EN ISO/IEC 17025 : 2018. The accreditation is only valid for the scope of accreditation listed in the document attachment D-PL-12032-01-02. The Deutsche Akkreditierungsstelle GmbH is a signatory of the Multilateral Agreements of EA, ILAC and IAF for mutual recog…

Text truncated - open the document above for the full version.

Test Setup Photos

EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPA-52190-A1-Pictures Anlage (Addendum) 5 1/9 Anlage 5 zu Prüfbericht Nr. TAR230614-EPA-52190-A (Addendum 5 to Test Report No. TAR230614-EPA-52190-A1) Diese Anlage besteht einschließlich diesem Deckblatt aus 6 Seiten. (This Addendum consists of 6 pages, including this cover page.) EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPA-52190-A1-Pictures Anlage (Addendum) 5 2/9 Dokumentation des Prüflings (Documentation of the EUT) TKD-SBES-MD-APC EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPA-52190-A1-Pictures Anlage (Addendum) 5 3/9 Dokumentation des Prüflings (Documentation of the EUT) TKD-SBES-AOD-APC EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPA-52190-A1-Pictures Anlage (Addendum) 5 4/9 Dokumentation des Prüflings (Documentation of the EUT) EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPA-52190-A1-Pictures Anlage (Addendum) 5 5/9 Simulatoren (Simulators) Vom Labor zur Verfügung gestellt. (Provided by the laboratory.) EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPA-52190-A1-Pictures Anlage (Addendum) 5 6/9 Blockschaltbild (Block diagram) Höchste interne Taktfrequenz: Kein Oszillator vorhanden (Highest internal frequency) (No clock oscillator available) EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPA-52190-A1-Pictures Anlage (Addendum) 5 7/9 Anlage 6 zu Prüfbericht Nr. TAR230614-EPA-52190-A1 (Addendum 6 to Test Report No. TAR230614-EPA-52190-A1) Diese Anlage besteht einschließlich diesem Deckblatt aus 3 Seiten. (This Addendum consists of 3 pages, including this cover page.) EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPA-52190-A1-Pictures Anlage (Addendum) 5 8/9 Dokumentation der Prüfaufbauten (Documentation of the test setup) Prüfung (test): Störaussendung, Messung der Funkstörspannung (emission, Measurement of interference voltage ) EMV Prüfbericht (EMC Test Report) 05.12.2023 TAR230614-EPA-52190-A1-Pictures Anlage (Addendum) 5 9/9 Dokumentation der Prüfaufbauten (Documentation of the test setup) Prüfung (test): Störaussendung, Messung der Funkstörfeldstärke (30 MHz – 1000 MHz) (emission, Measurement of radiated electromagnetic field (30 MHz – 1000 MHz))

Contact Information

Applicant

Mike Decker(Technical Manager)
[email protected]+49292138038Fax: +49 2921 38038-9244

Technical Contact

TARGA GmbHChristian Stamen
[email protected]00492921380380

Coesterweg 45, · Germany

Non-Technical Contact

TARGA GmbHMike Decker
[email protected]0049292138038

Test Firm

Obering, Berg & Lukowiak GmbHChristian Benthin
[email protected]49-5744-9296-0Fax: 49-5744-9296-15

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term