Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
NETVUEINC. 2.911(d)(5)(i)EquipmentTypeAttestationv1.2 Section2.911(d)(5)(i)Certification–EquipmentType Companyname:NETVUEINC. Address:1055EastColoradoBoulevard5thFloorPasadena,CA,91106 ProductName:BirdfyCam2Pro FCCID:2BC96NI-8611 Model(s):NI-8611,NI-8610,NI-8612,NI-8613,NI-8614,NI-8615,NI-8616,NI-8617,NI-8618,NI-8619 2.911(d)(5)(i)EquipmentType We,[NETVUEINC.](“theapplicant”)certifythattheequipmentforwhichauthorizationissought throughcertificationisnot: Prohibitedfromreceivinganequipmentauthorizationpursuantto§2.903;oftheFCCrules. Identifiedasanequipmenttypeinthe“CoveredList” NOTE1 Yourssincerely, Name:StoneFengDate:2024.08.30 TitleandCompanyname:Manager/NETVUEINC. NOTE1 “CoveredList ” ;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
NETVUEINC. 2.911(d)(5)(ii)ApplicantAttestationv1.3 Section2.911(d)(5)(ii)Certification–Applicant(CoveredList) Companyname:NETVUEINC. Address:1055EastColoradoBoulevard5thFloorPasadena,CA,91106 ProductName:BirdfyCam2Pro FCCID:2BC96NI-8611 Model(s):NI-8611,NI-8610,NI-8612,NI-8613,NI-8614,NI-8615,NI-8616,NI-8617,NI-8618,NI-8619 2.911(d)(5)(ii)Applicantfiling We,[NETVUEINC.](“theapplicant”)certifythat,asofthedateofthefilingoftheapplication,the applicantisisnotidentified NOTE1 onthe“CoveredList” NOTE2 ,establishedpursuantto§1.50002of thischapter,asanentityproducingcoveredcommunicationsequipment. Yourssincerely, Name:StoneFengDate:2024.08.30 TitleandCompanyname:Manager/NETVUEINC. NOTE1 Deleteoptionnotapplicabletothisapplication. NOTE2 “CoveredList ” ;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
NETVUEINC. 2.911(d)(7)USAAgentv1.3 Section2.911(d)(7)USAAgentforServiceofProcess Companyname:NETVUEINC. Address:1055EastColoradoBoulevard5thFloorPasadena,CA,91106 ProductName:BirdfyCam2Pro FCCID:2BC96NI-8611 Model(s):NI-8611,NI-8610,NI-8612,NI-8613,NI-8614,NI-8615,NI-8616,NI-8617, NI-8618,NI-8619 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[NETVUEINC.](“theapplicant”)designate[NETVUEINC.] NOTE1 forthepurpose ofacceptingserviceofprocessonbehalfoftheapplicant. Applicantconsent:WeAcknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminated allmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolving theequipment,whicheverislater. Agentobligation:WeAcknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,ortheconclusionofanyCommission-relatedadministrativeorjudicial proceedinginvolvingtheequipment,whicheverislater. USAAgent Companyname:NETVUEINC. Address:1055EastColoradoBoulevard 5thFloorPasadena,CA,91106 FRN:0034380907 ContactName:Stone.feng TelephoneNo:+1(866)749-567 Email:[email protected] Applicant Companyname:NETVUEINC. Address:1055EastColoradoBoulevard 5thFloorPasadena,CA,91106 FRN:0034380907 FCCGranteeCode:2BC96 ContactName:Stone.feng TelephoneNo:+1(866)749-567 Email:[email protected] NETVUEINC. 2.911(d)(7)USAAgentv1.3 Signature: Title:Manager Signature: Title:Manager Date:2024.8.30Date:2024.8.30 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the
NETVUEINC. AgentAuthorization Company:NETVUEINC. Address:1055EastColoradoBoulevard5thFloorPasadena,CA,91106 ProductName: BirdfyCam2Pro ModelNumber(s): NI-8611,NI-8610,NI-8612,NI-8613,NI-8614,NI-8615,NI-8616,NI-8617, NI-8618,NI-8619 ProductDescription: BirdfyCam2Pro WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2024.08.30 Name:StoneFeng Title:Manager Company: NETVUEINC.
NETVUEINC. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2024.08.30 Subject;RequestforConfidentiality FCCID:2BC96NI-8611 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:StoneFeng Title:Manager
NETVUEINC. ModelDifferent ProductName:BirdfyCam2Pro FCCID:2BC96NI-8611 Model(s):NI-8611,NI-8610,NI-8612,NI-8613,NI-8614,NI-8615,NI-8616,NI-8617, NI-8618,NI-8619 Allmodel’sthefunction,softwareandelectriccircuitarethesame,exceptthemodel number. Name:StoneFeng Date:2024-08-30 Title:Manager Signatureofapplicant:
Birdfy Cam 2 pro机身标贴 30mm 20mm Birdfy Cam 2 Pro Birdfy Model: NI-8611 FCC ID: 2BC96NI-8611 HVIN: N11BCB IC: 31482-NI8611 DC: 5V 1.5A IC: 31482-NI8611 Birdfy Cam 2 Pro Birdfy Model: NI-8610 FCC ID: 2BC96NI-8611 HVIN: N11BCB DC: 5V 1.5A IC: 31482-NI8611 Birdfy Cam 2 Pro Birdfy Model: NI-8612 FCC ID: 2BC96NI-8611 HVIN: N11BCB DC: 5V 1.5A
FCCID:2BC96NI-8611 RFExposureEvaluation Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequencyrange (MHz) Electricfield strength (V/m) Magneticfieldstrength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennainmW; G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthetotalpowerinputto theantenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitisreached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. TestResultofRFExposureEvaluation Modulation Frequency (MHz) Outputpower toantenna (dBm) Outputpower toantenna (mW) PowerDensity atR=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 802.11b 241217.1852.23960.0215141.0PASS 243716.7747.53350.0195761.0PASS 246217.0550.69910.0208801.0PASS 802.11g 241216.7847.64310.0196211.0PASS 243716.6446.13180.0189991.0PASS 246216.2341.97590.0172871.0PASS 802.11n20 241215.6836.98280.0152311.0PASS 243715.1032.35940.0133271.0PASS 246215.3534.27680.0141171.0PASS Remark:WIFIAntennagainis3.16dBi SoaSARtestisnotrequired
深圳市 深圳市 鑫域达科技 鑫域达科技 有限公司 有限公司 SHENGZHENXYDTELECOMMUNICATIONTECHNOLOGYCO.,LTD. 移动通信终端天线 Mobilecommunicationterminalantenna 产品设计与制造规格书 Productdesignandmanufacturingspecifications ◆客户名称/Customer:天和荣 ◆项目名称/Project:birdfy2主摄 ◆物料名称/Name:WiFiAntenna ◆天线材质/Antennamaterials:FPC ◆物料编号/Partno:XYD-THR-ZSWIFI-01 ◆设计/Designer: ◆审核/Check: ◆客户确认签章/Approved: 地址/Add:深圳市南山区西丽镇平山一路云谷二期8栋505 Rm505,8thbuilding,Yungu2ndperiod,pingshanNo.1Road,XiliTown,NanshanDistrict,ShenZhen,China 电话/Tel:86-755-83763273 传真/Fax:86-755-83763348 电邮/Email:[email protected] 目录 :/ list 1. 天线 2D 图 /Antenna2Ddiagram 2. 技术指标 /Technicaltarget 3. 动态测试说明 /Dynamictestinstruction 4. 天线安装图示/ Diagramofantennainstallation 5. 匹配电路 /MatchingCircuit 6. 天线测试数据 /Antennatestreport 7. 包装方式 /Packingmethod 1. 天线 2D 图 /Antenna2Ddiagram 2. 技术指标 /Technicaltarget A.电气性能/ElectricalParameter 工作频率范围/FrequencyRange2400~2500MHz 驻波比/VSWR 2400~2500MHz:<1.5 天线增益/Gain(Max) 2400~2500MHz:3.16dBi 平均辐射效率/ Averageradiationefficiency 2400~2500MHz:60.3% 阻抗/InputImpedance50ohm B.材料/Material FPC C.环境/EnvironmentalScience 工作温度/WorkingTemperature -30 ̊C~+85 ̊C 储藏温度/Storagetemperature -30 ̊C~+85 ̊C 3. 动态测试数据 --- 天线安置在设备里 /Dynamictestinstructions-Antennasareplacedin electronicscales 测试仪器/ Testinginstrument : AnritsCMW500+AnechoicChamber6X4X3m(3D-OTA) RF in/out Agilent5071B Agilent8960E5515C 4. 天线安装图示/Diagramofantennainstallation 5. 匹配电路 /MatchingCircuit (天线匹配未做修改/Theantennamatchhasnotbeenmodified) 6. 天线实际测试数据 /Antennatestreport 6.1)天线无源测试数据/ Passiveantennatestdata 6.2)天线有源测试数据/ Activeantennatestdata 6.3)天线效率/增益/方向图 AntennaEfficiency/gain/pattern 7. 包装方式 /Packingmethod 1.单个产品2D图/2Ddrawingoftheproduct 产品料号/ Theproductmaterial number XYD-THR- ZSWIFI-01 产品名称/ Productname birdfy2主摄 _WIFI/FPC 产品版本/ Productversion V3 2.箱内所有层堆放后的照片 /Photosofallstackedlayers inthebox 3.整箱封箱后的照片/Photoofthe wholecaseaftersealing 整版数量/ Numberoffullpages 按实际出货数量 /Inactual quantity 备注:每箱数量以实际为准,左侧图片为参考,按 实物为准。/Remarks:thequantityofeachbox shallbeactual,thepictureontheleftside shallbeforreference,andtheactualgoods shallberegardedasstandard. 储存条件:-10°至30°之间,湿度70%RH以下 的室内./Storageconditions:between-10° to30°,humidity70%Rhbelowtheindoor. 4.整包的照片/ Awholepackofphotos 5.整箱的箱表面贴的标签的照片/A photographofthelabelonthe surfaceoftheentirecase 注:上图中的图片只用做包装标准示范,不能用做最终资料审核。/Note:thepictureinthepictureaboveisonlyused forpackingstandarddemonstration,notforfinaldataaudit. 确认者 /Confirmer 杨小平/ YangXiaoping 日期/Date2024-4-11 注/Remark: 1.以上测试结果限于测试样机/Theabovetestresultsarelimitedtothetestprototype. 2.整机壳料工艺、软件版本、配件(摄像头FPC、喇叭、听筒、马达、电池等)、芯 片的改变都会导致整机天线性能变化。/Fullshellmaterialtechnology,softwareversion,accessories (camera,FPC,speaker,receiver,motor,battery,etc.),core Theperformanceofthewholeantennawillchangewiththechangeofthechip. 3.整机的环境处理(如接地位置、尺寸,屏蔽方式等)改变会导致整机性能变化。/Thechangeofenvironmental treatment(suchasgroundingposition,size,shieldingmode,etc.)ofthewholemachinewilllead tothechangeoftheperformanceofthewholemachine. 郑重申明/Solemnlydeclare: 此款天线设计、研发知识产权为我司所有,如发现有相同产品未经我司允许供应给贵司,我司将依法追 究相应法律责任,请尊重知识产权,您的支持是我们的无限动力,谢谢合作!/ThisantennadesignandR&D intellectualpropertyrightsareownedbyourcompany.Ifwefindthatthesameproductsaresupplied toyourcompanywithoutourpermission,wewillpursuethecorrespondinglegalresponsibility accordingtolaw.Pleaserespectintellectualpropertyrights.Yoursupportisourunlimitedpower. Thankyouforyourcooperation.
FCCTESTREPORT FCCID:2BC96NI-8611 Product: BirdfyCam2Pro ModelName: NI-8611,NI-8610,NI-8612,NI-8613,NI-8614, NI-8615,NI-8616,NI-8617,NI-8618,NI-8619 Brand: Birdfy ReportNo.: NCT24019450XE1-1 Preparedfor NETVUEINC. 1055EastColoradoBoulevard5thFloorPasadena,CA,91106 Preparedby ShenzhenNCTTestingTechnologyCo.,Ltd. A101&2FB2,Fuqiao6thArea,XintianCommunity,FuhaiStreet,BaoanDistrict, Shenzhen,People’sRepublicofChina TEL:400-8868-419 FAX:86-755-27790922 ReportNo.:NCT24019450XE1-1 Page2of35 Hotline:400-8868-419Fax:86-755-27790922http://www.ncttesting.cn 1TESTRESULTCERTIFICATION Applicant’sname :NETVUEINC. Address:1055EastColoradoBoulevard5thFloorPasadena,CA,91106 Manufacture's name :NETVUEINC. Address:1055EastColoradoBoulevard5thFloorPasadena,CA,91106 Productname:BirdfyCam2Pro Modelname: NI-8611,NI-8610,NI-8612,NI-8613,NI-8614,NI-8615, NI-8616,NI-8617,NI-8618,NI-8619 Standards:FCCCFR47Part15Section15.247 Testprocedure:ANSIC63.10:2013 Dateoftest:May08,2024-May28,2024 DateofIssue:May28,2024 ThisdevicedescribedabovehasbeentestedbyNCT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofNCT,thisdocumentmaybe alteredorrevisedbyNCT,personalonly,andshallbenotedintherevisionofthedocument. TestEngineer: KevenWu/Engineer TechnicalManager: HenryWang/Manager ReportNo.:NCT24019450XE1-1 Page3of35 Hotline:400-8868-419Fax:86-755-27790922http://www.ncttesting.cn Contents Page 1TESTRESULTCERTIFICATION...............................................................................................................................2 2TESTSUMMARY..........................................................................................................................................................5 3GENERALINFORMATION..........................................................................................................................................6 3.1GENERALDESCRIPTIONOFE.U.T.....................................................................................................................6 3.2CHANNELLIST.....................................................................................................................................................7 3.3TESTSITE............................................................................................................................................................8 3.4TESTSETUPCONFIGURATION............................................................................................................................8 3.5TESTMODE.........................................................................................................................................................9 4EQUIPMENTDURINGTEST....................................................................................................................................10 4.1EQUIPMENTSLIST.............................................................................................................................................10 4.2MEASUREMENTUNCERTAINTY.........................................................................................................................12 4.3DESCRIPTIONOFSUPPORTUNITS...................................................................................................................12 5CONDUCTEDEMISSION..........................................................................................................................................13 5.1E.U.T.OPERATION............................................................................................................................................13 5.2EUTSETUP.......................................................................................................................................................13 5.3TESTSET-UP(BLOCKDIAGRAMOFCONFIGURATION).................................................................................14 5.4MEASUREMENTPROCEDURE............................................................................................................................14 5.5CONDUCTEDEMISSIONLIMIT...........................................................................................................................14 5.6MEASUREMENTDESCRIPTION..........................................................................................................................14 5.7CONDUCTEDEMISSIONTESTRESULT.............................................................................................................14 6RADIATEDSPURIOUSEMISSIONS......................................................................................................................17 6.1EUTOPERATION...............................................................................................................................................17 6.2TESTSETUP......................................................................................................................................................18 6.3SPECTRUMANALYZERSETUP..........................................................................................................................19 6.4TESTPROCEDURE.............................................................................................................................................20 6.5SUMMARYOFTESTRESULTS...........................................................................................................................21 7CONDUCTBANDEDGEANDSPURIOUSEMISSIONSMEASUREMENT....................................................30 7.1TESTPROCEDURE.............................................................................................................................................30 7.2TESTRESULT....................................................................................................................................................30 ReportNo.…
Text truncated - open the document above for the full version.
TableofContents 1.-6dBBandwidth.......................................................................................................................................................2 2.99%OccupiedBandwidth....................................................................................................................................7 3.DutyCycle...............................................................................................................................................................12 4.MAX.OutputPower.............................................................................................................................................17 5.PowerSpectralDensity.......................................................................................................................................18 6.Bandedge................................................................................................................................................................23 7.SpuriousEmission.................................................................................................................................................29 Page2of37 FCCID&ICIDWIFI2.4 Part15.247&RSS-247TestData 1.-6dBBandwidth ConditionAntennaModulationFrequency(MHz)-6dBBW(MHz)limit(kHz)Result NVNTANT1802.11b2412.008.60500Pass NVNTANT1802.11b2437.008.09500Pass NVNTANT1802.11b2462.008.11500Pass NVNTANT1802.11g2412.0016.48500Pass NVNTANT1802.11g2437.0015.38500Pass NVNTANT1802.11g2462.0016.42500Pass NVNTANT1802.11n(HT20)2412.0017.72500Pass NVNTANT1802.11n(HT20)2437.0015.96500Pass NVNTANT1802.11n(HT20)2462.0017.67500Pass -6dB_Bandwidth_NVNT_ANT1_802_11b_2412 -6dB_Bandwidth_NVNT_ANT1_802_11b_2437 Page3of37 -6dB_Bandwidth_NVNT_ANT1_802_11b_2462 -6dB_Bandwidth_NVNT_ANT1_802_11g_2412 Page4of37 -6dB_Bandwidth_NVNT_ANT1_802_11g_2437 -6dB_Bandwidth_NVNT_ANT1_802_11g_2462 Page5of37 -6dB_Bandwidth_NVNT_ANT1_802_11n(HT20)_2412 -6dB_Bandwidth_NVNT_ANT1_802_11n(HT20)_2437 Page6of37 -6dB_Bandwidth_NVNT_ANT1_802_11n(HT20)_2462 Page7of37 2.99%OccupiedBandwidth ConditionAntennaModulationFrequency(MHz)99%%BW(MHz) NVNTANT1802.11b2412.0013.636 NVNTANT1802.11b2437.0013.153 NVNTANT1802.11b2462.0013.486 NVNTANT1802.11g2412.0017.460 NVNTANT1802.11g2437.0017.498 NVNTANT1802.11g2462.0017.241 NVNTANT1802.11n(HT20)2412.0018.251 NVNTANT1802.11n(HT20)2437.0018.166 NVNTANT1802.11n(HT20)2462.0018.142 99%_Occupied_Bandwidth_NVNT_ANT1_802_11b_2412 99%_Occupied_Bandwidth_NVNT_ANT1_802_11b_2437 Page8of37 99%_Occupied_Bandwidth_NVNT_ANT1_802_11b_2462 99%_Occupied_Bandwidth_NVNT_ANT1_802_11g_2412 99%_Occupied_Bandwidth_NVNT_ANT1_802_11g_2437 Page9of37 99%_Occupied_Bandwidth_NVNT_ANT1_802_11g_2462 99%_Occupied_Bandwidth_NVNT_ANT1_802_11n(HT20)_2412 Page10of37 99%_Occupied_Bandwidth_NVNT_ANT1_802_11n(HT20)_2437 99%_Occupied_Bandwidth_NVNT_ANT1_802_11n(HT20)_2462 Page11of37 Page12of37 3.DutyCycle ConditionAntennaModulationFrequency(MHz)Dutycycle(%)Dutyfactor(dB) NVNTANT1802.11b2412.001000.00 NVNTANT1802.11b2437.001000.00 NVNTANT1802.11b2462.001000.00 NVNTANT1802.11g2412.001000.00 NVNTANT1802.11g2437.001000.00 NVNTANT1802.11g2462.001000.00 NVNTANT1802.11n(HT20)2412.001000.00 NVNTANT1802.11n(HT20)2437.001000.00 NVNTANT1802.11n(HT20)2462.001000.00 Duty_Cycle_NVNT_ANT1_802_11b_2412 Duty_Cycle_NVNT_ANT1_802_11b_2437 Page13of37 Duty_Cycle_NVNT_ANT1_802_11b_2462 Duty_Cycle_NVNT_ANT1_802_11g_2412 Duty_Cycle_NVNT_ANT1_802_11g_2437 Page14of37 Duty_Cycle_NVNT_ANT1_802_11g_2462 Duty_Cycle_NVNT_ANT1_802_11n(HT20)_2412 Page15of37 Duty_Cycle_NVNT_ANT1_802_11n(HT20)_2437 Duty_Cycle_NVNT_ANT1_802_11n(HT20)_2462 Page16of37 Page17of37 4.MAX.OutputPower ConditionAntennaModulation Frequency (MHz) Detector Conducted Power(dBm) Antenna Gain(dB) Conducted Power limit(dBm) EIRP(dBm) EIRP limit(dBm) Result NVNTANT1802.11b2412.00Peak17.18 3.16 3020.3436Pass NVNTANT1802.11b2437.00Peak16.77 3.16 3019.9336Pass NVNTANT1802.11b2462.00Peak17.05 3.16 3020.2136Pass NVNTANT1802.11g2412.00Peak16.78 3.16 3019.9436Pass NVNTANT1802.11g2437.00Peak16.64 3.16 3019.8036Pass NVNTANT1802.11g2462.00Peak16.23 3.16 3019.3936Pass NVNTANT1802.11n(HT20)2412.00Peak15.68 3.16 3018.8436Pass NVNTANT1802.11n(HT20)2437.00Peak15.10 3.16 3018.2636Pass NVNTANT1802.11n(HT20)2462.00Peak15.35 3.16 3018.5136Pass Page18of37 5.PowerSpectralDensity ConditionAntennaModulation Frequency (MHz) PSD(dBm/30kHz) RB factor(dB) PSD(dBm/3kHz)limit(dBm/3kHz)Result NVNTANT1802.11b2412.00-0.12-10.00-10.128Pass NVNTANT1802.11b2437.00-0.12-10.00-10.128Pass NVNTANT1802.11b2462.000.51-10.00-9.498Pass NVNTANT1802.11g2412.00-7.43-10.00-17.438Pass NVNTANT1802.11g2437.00-2.91-10.00-12.918Pass NVNTANT1802.11g2462.00-6.38-10.00-16.388Pass NVNTANT1802.11n(HT20)2412.00-7.79-10.00-17.808Pass NVNTANT1802.11n(HT20)2437.00-3.07-10.00-13.078Pass NVNTANT1802.11n(HT20)2462.00-6.88-10.00-16.888Pass Power_Spectral_Density_NVNT_ANT1_802_11b_2412 Power_Spectral_Density_NVNT_ANT1_802_11b_2437 Page19of37 Power_Spectral_Density_NVNT_ANT1_802_11b_2462 Power_Spectral_Density_NVNT_ANT1_802_11g_2412 Power_Spectral_Density_NVNT_ANT1_802_11g_2437 Page20of37 Power_Spectral_Density_NVNT_ANT1_802_11g_2462 Power_Spectral_Density_NVNT_ANT1_802_11n(HT20)_2412 Page21of37 Power_Spectral_Density_NVNT_ANT1_802_11n(HT20)_2437 Power_Spectral_Density_NVNT_ANT1_802_11n(HT20)_2462 Page22of37 Page23of37 6.Bandedge ConditionAntennaModulation TX_Frequency (MHz) Max. Mark_frequency(MHz) Spurious level(dBm) limit(dBm)Result NVNTANT1802.11b2412.002397.024-37.525-15.563Pass NVNTANT1802.11b2462.002487.376-59.613-15.741Pass NVNTANT1802.11g2412.002399.824-40.019-25.279Pass NVNTANT1802.11g2462.002483.824-56.472-24.386Pass NVNTANT1802.11n(HT20)2412.002399.936-38.558-25.462Pass NVNTANT1802.11n(HT20)2462.002483.536-54.960-25.027Pass 1_Reference_Level_NVNT_ANT1_802_11b_2412 2_Bandedge_NVNT_ANT1_802_11b_2412 1_Reference_Level_NVNT_ANT1_802_11b_2462 Page24of37 2_Bandedge_NVNT_ANT1_802_11b_2462 1_Reference_Level_NVNT_ANT1_802_11g_2412 Page25of37 2_Bandedge_NVNT_ANT1_802_11g_24…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 52.24 mW |
BIRDFY SMART HUM FEEDER RUBY
Equipment Class
DTS - Digital Transmission SystemBirdfy Feeder Bamboo Mini
Equipment Class
DTS - Digital Transmission SystemBIRDFY SMART BIRD HOUSE CYAN
Equipment Class
DTS - Digital Transmission SystemBIRDFY SMART BIRD FEEDER CYAN
Equipment Class
DTS - Digital Transmission System