Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 19, 2024
Application Purpose
Original Equipment
Date of Application
May 19, 2024
Equipment Note
Smart Slim Panel
Frequency Range
2412.00000000 - 2462.00000000
Company
Dot Lighting (canada) Inc.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

TM smart TM smart FCC Cau�on: Any Changes or modifica�ons not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Opera�on is subject to the following two condi�ons: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired opera�on. IMPORTANT NOTE: Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protec�on against harmful interference in a residen�al installa�on. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc�ons, may cause harmful interference to radio communica�ons. However, there is no guarantee that interference will not occur in a par�cular installa�on. If this equipment does cause harmful interference to radio or television recep�on, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separa�on between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. ISED Warning This device complies with Innova�on, Science, and Economic Development Canada licence-exempt RSS standard(s). Opera�on is subject to the following two condi�ons: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired opera�on of the device. Le présent appareil est conforme aux CNR d' Innova�on, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploita�on est autorisée aux deux condi�ons suivantes : (1) l'appareil nedoit pas produire de brouillage, et (2) l'u�lisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscep�ble d'en comprome�re le fonc�onnement. The device is compliance with RF exposure guidelines, users can obtain Canadian informa�on on RF exposure and compliance.The minimum distance from body to use the device is 20cm. Le présent appareil est conforme Après examen de ce matériel aux conformité ou aux limites d’intensité de champ RF, les u�lisateurs peuvent sur l’exposi�on aux radiofréquences et la conformité and compliance d’acquérir les informa�ons correspondantes. La distance minimale du corps à u�liser le disposi�f est de 20cm This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Attestation Statements

CFR 47 §2.911(d)(5)(i) Attestation Letter Dot Lighting (canada) Inc. Address: 35 Riviera Dr Unit 16 Markham Ontario L3R 8N4 Canada Tel.: 647-972-7128 E-mail: [email protected] Attestation Letter Date: 2024-04-26 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID:2BCMV-MBWF Dot Lighting (canada) Inc. certifies that the equipment for which authorization is sought, is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Signature Print Name: YIMIN QIU Title: Director

Attestation Statements

CFR 47 §2.911 (d)(5)(ii) Attestation Letter Dot Lighting (canada) Inc. Address: 35 Riviera Dr Unit 16 Markham Ontario L3R 8N4 Canada Tel.: 647-972-7128 E-mail: [email protected] Attestation Letter Date: 2024-04-26 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID: 2BCMV-MBWF Dot Lighting (canada) Inc. certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature Print Name: YIMIN QIU Title: Director

Cover Letter(s)

Dot Lighting (canada) Inc. Address: 35 Riviera Dr Unit 16 Markham Ontario L3R 8N4 Canada Tel.: 647-972-7128 E-mail: [email protected] QA-FR-170-B 7/29/2014 FCC Authorization Date: 2024-04-26 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Dot Lighting (canada) Inc. the undersigned, hereby authorizes World Alliance Testing & Certification (Shenzhen) Co., Ltd to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by World Alliance Testing & Certification (Shenzhen) Co., Ltd on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely, Signature Print Name: YIMIN QIU Title: Director

Cover Letter(s)

Dot Lighting (canada) Inc. Address: 35 Riviera Dr Unit 16 Markham Ontario L3R 8N4 Canada Tel.: 647-972-7128 E-mail: [email protected] FCC Confidential Authorization Date: 2024-04-26 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2BCMV-MBWF In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Dot Lighting (canada) Inc. hereby requests long-term confidential treatment of information accompanying this application as outlined below:  Block Diagram  Schematics  Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature Print Name: YIMIN QIU Title: Director

Cover Letter(s)

Dot Lighting (canada) Inc. Address: 35 Riviera Dr Unit 16 Markham Ontario L3R 8N4 Canada Tel.: 647-972-7128 E-mail: [email protected] Attestation letter Date: 2024-04-26 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir or Madam, Our product Smart Slim Panel, Model Name: QLEDMB-4inch-10W-RGBWF, FCC ID: 2BCMV-MBWF, for marketing purpose, this product only supports 2.4G Wi-Fi (2412-2462MHz, 802.11b/g/n20/n40 modes). The other functions, bands and modes was disabled to use by manufacturer in the software, the end user has no capability to activate it. Sincerely, Signature: Print Name: YIMIN QIU Title : Director

External Photos

Report No.: RWAP202400204 Page 1 of 6 EUT EXTERNAL PHOTOGRAPHS Report No.: RWAP202400204 Page 2 of 6 Report No.: RWAP202400204 Page 3 of 6 Report No.: RWAP202400204 Page 4 of 6 Report No.: RWAP202400204 Page 5 of 6 Report No.: RWAP202400204 Page 6 of 6

ID Label/Location Info

Label Dot Lighting (canada) Inc. Smart Slim Panel Model NO.: QLEDMB-4inch-10W-RGBWF FCC ID: 2BCMV-MBWF IC: 31266-MBWF Label Location

Internal Photos

Report No.: RWAP202400204 Page 1 of 5 EUT INTERNAL PHOTOGRAPHS Report No.: RWAP202400204 Page 2 of 5 Report No.: RWAP202400204 Page 3 of 5 Report No.: RWAP202400204 Page 4 of 5 ANT Report No.: RWAP202400204 Page 5 of 5

RF Exposure Info

Report No.: RWAP202400204C Report Template: TR-4-E-011/V1.0 Page 1 of 7 RF Exposure Evaluation Report Report No.: RWAP202400204C Applicant: Dot Lighting (canada) Inc. Address: 35 Riviera Dr Unit 16 Markham Ontario L3R 8N4 Canada Product Name: Smart Slim Panel Product Model: QLEDMB-4inch-10W-RGBWF Multiple Models: N/A Trade Mark: N/A FCC ID: 2BCMV-MBWF Standards: 47 CFR §1.1307 KDB 447498 D04 Interim General RF Exposure Guidance v01 Test Date: 2024-03-05 Test Result: Complied Report Date: 2024-03-15 Reviewed by: Approved by: Abel Chen Project Engineer Jacob Kong Manager Prepared by: World Alliance Testing & Certification (Shenzhen) Co., Ltd No. 1002, East Block, Laobing Building, Xingye Road 3012, Xixiang street, Bao'an District, Shenzhen, Guangdong, People’s Republic of China This report may contain data that are not covered by the NVLAP accreditation and shall be marked with an asterisk “★” Report No.: RWAP202400204C Report Template: TR-4-E-011/V1.0 Page 2 of 7 Announcement 1.This test report shall not be reproduced except in full, without the written approval of World Alliance Testi ng & Certification (Shenzhen) Co., Ltd 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the limits of the above regulation. 4. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. 5. The information marked “#” is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. Revision History Version No. Issued Date Description 00 2024-03-15 Original Report No.: RWAP202400204C Report Template: TR-4-E-011/V1.0 Page 3 of 7 Contents 1 General Information ............................................................................................................................ 4 1.1 Client Information ...................................................................................................................... 4 1.2 Product Description of EUT ....................................................................................................... 4 1.3 Laboratory Location ................................................................................................................... 4 2 RF Exposure Evaluation ..................................................................................................................... 5 2.1 Standard .................................................................................................................................... 5 2.2 Result......................................................................................................................................... 7 Report No.: RWAP202400204C Report Template: TR-4-E-011/V1.0 Page 4 of 7 1 General Information 1.1 Client Information Applicant: Dot Lighting (canada) Inc. Address: 35 Riviera Dr Unit 16 Markham Ontario L3R 8N4 Canada Manufacturer: Dot Lighting (canada) Inc. Address: 35 Riviera Dr Unit 16 Markham Ontario L3R 8N4 Canada 1.2 Product Description of EUT The EUT is a Smart Slim Panel that contains 2.4G WLAN radio. Sample Serial Number 68-3 (assigned by WATC) Sample Received Date 2024-02-23 Sample Status Good Condition Frequency Range 2.4G WLAN: 2412MHz - 2462MHz Maximum Conducted Output Power 27.70dBm Modulation Technology DSSS, OFDM Antenna Gain # 2.21dBi Spatial Streams SISO (1TX, 1RX) Power Supply AC 120V/60Hz Operating temperature # -40 deg.C to +105 deg.C Adapter Information N/A Modification Sample No Modification by the test lab 1.3 Laboratory Location World Alliance Testing & Certification (Shenzhen) Co., Ltd No. 1002, East Block, Laobing Building, Xingye Road 3012, Xixiang street, Bao'an District, Shenzhen, Guangdong, People’s Republic of China Tel: +86-755-29691511, Email: [email protected] The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 463912, the FCC Designation No. : CN5040. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0160. Report No.: RWAP202400204C Report Template: TR-4-E-011/V1.0 Page 5 of 7 2 RF Exposure Evaluation 2.1 Standard According to §1.1307(b)(3)(i), For single RF sources (i.e., any single fixed RF source, mobile device, or portable device, as defined in paragraph (b)(2) of this section): A single RF source is exempt if: (A) The available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption may not be used in conjunction with other exemption criteria other than those in paragraph (b)(3)(ii)(A) of this section. Medical implant devices may only use this exemption and that in paragraph (b)(3)(ii)(A); (B) Or the available maximum time-averaged power or effective radiated power (ERP), whichever is greater, is less than or equal to the threshold Pth (mW) described in the following formula. This method shall only be used at separation distances (cm) from 0.5 centimeters to 40 centimeters and at frequencies from 0.3 GHz to 6 GHz (inclusive). Pth is given by: (C) Or using Table 1 and the minimum separation distance (R in meters) from the body of a nearby person for the frequency (f in MHz) at which the source operates, the ERP (watts) is no more than the calculated value prescribed for that frequency. For the exemption in Table 1 to apply, R must be at least λ/2π, where λ is the free-space operating wavelength in meters. If the ERP of a single RF source is not easily obtained, then the available maximum time-averaged power may be used in lieu of ERP if the physical dimensions of the radiating structure(s) do not exceed the electrical length of λ/4 or if the antenna gain is less than that of a h…

Text truncated - open the document above for the full version.

Test Report

Report No.: RWAP202400204A Report Template: TR-4-E-009/V1.0 Page 1 of 36 FCC Test Report Report No.: RWAP202400204A Applicant: Dot Lighting (canada) Inc. Address: 35 Riviera Dr Unit 16 Markham Ontario L3R 8N4 Canada Product Name: Smart Slim Panel Product Model: QLEDMB-4inch-10W-RGBWF Multiple Models: N/A Trade Mark: N/A FCC ID: 2BCMV-MBWF Standards: FCC CFR Title 47 Part 15C (§15.247) Test Date: 2024-02-26 to 2024-03-05 Test Result: Complied Report Date: 2024-03-15 Reviewed by: Approved by: Abel Chen Project Engineer Jacob Kong Manager Prepared by: World Alliance Testing & Certification (Shenzhen) Co., Ltd No. 1002, East Block, Laobing Building, Xingye Road 3012, Xixiang street, Bao'an District, Shenzhen, Guangdong, People’s Republic of China This report may contain data that are not covered by the NVLAP accreditation and shall be marked with an asterisk “★” Report No.: RWAP202400204A Report Template: TR-4-E-009/V1.0 Page 2 of 36 Announcement 1.This test report shall not be reproduced except in full, without the written approval of World Alliance Testi ng & Certification (Shenzhen) Co., Ltd 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the limits of the above regulation. 4. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. 5. The information marked “#” is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. Revision History Version No. Issued Date Description 00 2024-03-15 Original Report No.: RWAP202400204A Report Template: TR-4-E-009/V1.0 Page 3 of 36 Contents 1 General Information ............................................................................................................................ 4 1.1 Client Information ...................................................................................................................... 4 1.2 Product Description of EUT ....................................................................................................... 4 1.3 Antenna information .................................................................................................................. 4 1.4 Related Submittal(s)/Grant(s) .................................................................................................... 5 1.5 Measurement Uncertainty ......................................................................................................... 5 1.6 Laboratory Location ................................................................................................................... 5 1.7 Test Methodology ...................................................................................................................... 5 2 Description of Measurement .............................................................................................................. 6 2.1 Test Configuration ...................................................................................................................... 6 2.2 Test Auxiliary Equipment ........................................................................................................... 7 2.3 Test Setup .................................................................................................................................. 7 2.4 Test Procedure .......................................................................................................................... 9 2.5 Measurement Method.............................................................................................................. 10 2.6 Measurement Equipment ......................................................................................................... 11 3 Test Results ....................................................................................................................................... 12 3.1 Test Summary .......................................................................................................................... 12 3.2 Limit ......................................................................................................................................... 13 3.3 AC Line Conducted Emissions Test Data ................................................................................ 14 3.4 Radiated emission Test Data ................................................................................................... 16 3.5 RF Conducted Test Data ......................................................................................................... 24 3.5.1 6dB Emission Bandwidth and 99% Occupied Bandwidth ............................................ 24 3.5.2 Maximum Conducted Peak Output Power ................................................................... 24 3.5.3 Power Spectral Density ................................................................................................ 25 3.5.4 100 kHz Bandwidth of Frequency Band Edge ............................................................. 25 3.5.5 Duty Cycle .................................................................................................................... 25 4 Test Setup Photo ............................................................................................................................... 35 5 E.U.T Photo ........................................................................................................................................ 36 Report No.: RWAP202400204A Report Template: TR-4-E-009/V1.0 Page 4 of 36 1 General Information 1.1 Client Information Applicant: Dot Lighting (canada) Inc. Address: 35 Riviera Dr Unit 16 Markham Ontario L3R 8N4 Canada Manufacturer: Dot Lighting (canada) Inc. Address: 35 Riviera Dr Unit 16 Markham Ontario L3R 8…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: RWAP202400204 Page 1 of 2 TEST SETUP PHOTOGRAPHS AC Line Conducted Emission Report No.: RWAP202400204 Page 2 of 2 Radiated Emission Below 1GHz Above 1 GHz

Contact Information

Applicant

YIMIN QIU(Director)
[email protected]6479727128Fax: 905-6048832

Test Firm

World Alliance Testing & Certification (Shenzhen)Stefani Hu
[email protected]0755-29691511

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz589.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The device supports 20MHz and 40MHz bandwidths. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.