FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Cognition Controls Co./
  3. 2BCO5CC301

2BCO5CC301Smart Commercial Control

Cognition Controls Co.
Smart Commercial Control - FCC ID 2BCO5CC301 - Cognition Controls Co.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 01, 2024
Application Purpose
Original Equipment
Date of Application
Apr 01, 2024
Equipment Note
Smart Commercial Control
Frequency Range
2412.00000000 - 2462.00000000
Company
Cognition Controls Co.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

SmartCommercialControl UserGuide Version1.0.0 TableofContents TableofContents1 WelcometoCognitionControls2 Overview4 PowerCheck4 GettingStarted4 PairingaRemoteSensor4 Connectivity5 Configuration6 DataCommunication6 On-DeviceActions7 CognitionDashboard10 CognitionCommunications10 Permissions11 DeviceSpecifications12 HardwareRequirements12 TechnicalSpecifications12 SmartCommercialControlWireTerminalsandNotes13 DeviceInstallation15 IncludedinPackage15 InstallationTools15 InstallingtheSmartCommercialControl15 NavigatingtheCognitionDashboard17 <<willneedtoupdatefornewdashboardupdates>>17 QuickReferences21 AddTroubleshootingsection21 AdditionalInformation22 SettingupWiFiConnectiononDevice22 SmartCommercialControlUserGuide1 September2023 WelcometoCognitionControls AtCognitionControlswebelievethattechnologyispowerfulandcanassistinreducingenergy consumptioninthebuiltenvironmentwhilealsomanagingtheveryhumanandsubjective challengeofmaintainingcomfort.TheSmartCommercialControlispurposebuiltforlight commercial,retailandindustrialbuildings;andisapplicableinbothretrofitsandnewbuildings. OursolutionprovidesHVACprofessionalsandpropertyownerswithtoolsandinsightstobetter managetheircustomer’sequipmentandstrengthencustomerrelationships.Enduserswillfind thattheSmartCommercialControlintandemwiththeCognitionControlsDashboardprovides remotecontrolofcomfortandusefultoolsandinformationtoincreaseHVACenergysavings. Wethankyoufortrustinguswithyourbuilding'scomfort! SmartCommercialControlUserGuide2 September2023 FCCRegulations Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)This devicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation. ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttopart15of theFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceina residentialinstallation.Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalled andusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However, thereisnoguaranteethatinterferencewillnotoccurinaparticular installation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbe determinedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneor moreofthefollowingmeasures: -Reorientorrelocatethereceivingantenna. -Increasetheseparationbetweentheequipmentandreceiver. -Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected. -Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Changesormodificationsnotexpresslyapprovedbythemanufacturercouldvoidtheuser’sauthoritytooperatethe equipment. FCCRFRadiationExposureStatement ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforanuncontrolledenvironment.Tocomplywith FCCRFExposurecompliancerequirements,thisgrantisapplicabletoonlyMobileConfigurations.Theantennas usedforthetransmittermustbeinstalledtoprovideaseparationdistanceofatleast20cmfromallpersonsandmust notbeco-locatedoroperatinginconjunctionwith anyotherantennaortransmitter. ICNotice ThisdevicecomplieswithIndustryCanada’slicense-exemptRSSs.Operationissubject tothefollowingtwoconditions: 1.Thisdevicemaynotcauseinterference;and 2.Thisdevicemustacceptanyinterference,includinginterferencethatmaycause undesiredoperationofthedevice. SmartCommercialControlUserGuide3 September2023 L’appareilestconformeauRSSd’exemptiondelicenced’IndustrieCanada.LesopĂ©rationssont soumisesauxdeuxconditionssuivantes: 1.Cetappareilnepeutpascauserd’interfĂ©rence;Et 2.l’appareildoitacceptertouteinterfĂ©rence,ycompriscellesquipeuvententraĂźnerun fonctionnementindĂ©sirabledel’appareil. ICRadiationExposurestatement ThisdevicecomplieswithIcradiationexposurelimitssetforthforanuncontrolledenvironment .InordertoavoidthepossibilityofexceedingthelCradiofrequencyexposurelimits,human proximitytotheantennashallnotbelessthan20cmduringnormaloperation. L’appareilestconformeauxlimitesd’expositionaurayonnementICspĂ©cifiĂ©esdansunenvironnementnoncontrĂŽlĂ©. Afind’éviterlapossibilitĂ©dedĂ©passerlalimited’expositionauxRF LC,lecorpshumainnedoitpasĂȘtreĂ moinsde20cmdel’antennependantlefonctionnement normal. SmartCommercialControlUserGuide4 September2023 Overview PowerCheck TheSmartCommercialControlispoweredbytheHVACequipmentitcontrolsusingtheC-wire. -Pre-InstallCheck:Beforestartinganinstallation,confirmthepresenceandfunctionalityofthe C-wireattheexistingHVACcontrol. -NoC-wirepresent:IntheabsenceofaC-wire,onewillneedtobeinstalled.Furtherguidance canbefoundoncognitioncontrols.comunder"ToolsandGuides." GettingStarted EachSmartCommercialControlhasauniqueQRcodeonthebackoftheenclosure.Scanning theQRcodebeginstheinstallationprocess. -ScantheQR:Tobeginaninstall,scantheuniqueQRcodelocatedonthebackoftheSmart CommercialControl. -Followthestep-by-stepinstructions:Theinstallationflowisaquickstep-by-steptoguideto successfullyinstallTheSmartCommercialControl. -MultipleDevices:TheQRcodeoneachSmartCommercialControlisuniquetothatdevice.To ensureconnectionandconfigurationwiththeCognitiondashboardscantheQRcodeoneach devicetobeinstalled. PairingaRemoteSensor AremotesensorcanbequicklyandeasilypairedwithTheSmartCommercialControlfor enhancedmanagementoftrickyspace. -InstallationConsiderations:Beawareoffactorsthatmayobstructaccuratesensorreadings suchasinstallingdirectlyaboveaheat-emittingsourceordirectexposuretosunlight.Thesensor shouldbeinstalledwithin25feetoftheCognitiondevice. -RemoteSensorPairing&Installation:TheCognitionremotesensorseamlesslypairswiththe maindeviceviawirelessconnectivity.Eachsensorhasauniqueidentifier(color&shape)onthe backofitsenclosure.Thisidentifierwillbecriticalforpairingthesensorduringthedevice installation.Also,onthebackofthesensorisadouble-sidedadhesiveusedtomountthesensor tothedecidedsensorlocation. SmartCommercialControlUserGuide5 September2023 -OptimalRemoteSensorPlacement:Foridealperformanc


Text truncated - open the document above for the full version.

Attestation Statements

Cognition Controls Co. To: Federal Communications Commission Date: 2024/02/27 7435 Oakland Mills Road Columbia, MD 21046 USA Attestation Section 2.911(d)(5)(i) and Section 2.911(d)(5)(ii) (KDB 986446 D01 Covered Equipment) Section 2.911(d)(5)(i) Cognition Controls Co. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Section 2.911(d)(5)(ii) Cognition Controls Co. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Type of Equipment subject to FCC Certification:S-Guard FCC ID: 2BCO5CC301 If you have any questions, please feel free to contact me Sincerely, Signature: Print Name: Ty C Kartiganer Business NameCognition Controls Co. Email Address: [email protected]

Attestation Statements

[Cognition Controls Co.] [68 Harrison Ave.#605 ] [Boston/ Massachusetts] [United States] Date: [2024/02/27] Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: [2BCO5CC301 ] US Agent – Attestation Statement / Part 2.911(d)(7) [Cognition Controls Co.] certifies, that as of [2024/02/27], we have designated [ Cognition Controls Co.] to accept service of process on our behalf for FCC ID: [2BCO5CC301], FRN: 0034180638. [Cognition Controls Co.], accepts to maintain an agent of service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission- related administrative or judicial proceeding involving the equipment, whichever is later. Cognition Controls Co., accepts as of the date of the filing of this application, the obligation of being the designated agent for the purpose of accepting service of process on behalf of [Cognition Controls Co.] for FCC ID: [2BCO5CC301], FRN: 0034180638. Designated Agent Information: Company Name: Cognition Controls Co. FRN: 0034180638 Address: 68 Harrison Ave.#605, Boston, Massachusetts, United States Contact Person: Ty C Kartiganer Phone: 8608574604 Email: [email protected] Sincerely, Company: Cognition Controls Co. Company: Cognition Controls Co. Company Representative: Ty C Kartiganer Company Representative: Ty C Kartiganer Signature: Signature:

Cover Letter(s)

Cognition Controls Co. Request for Confidentiality Date: March 5, 2024 Subject: Confidentiality Request for: FCC ID: 2BCO5CC301 Pursuant to FCC 47 CRF 0.457(d), the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 1 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Schematics Short Term Permanent Test Setup Photos Short Term Permanent* User’s Manual *Note: ______(Insert Explanation as Necessary)______ Cognition Controls Co.has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TCB in the event information regarding the product or the product is made available to the public. TCB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, Signature: Print Name: Ty C Kartiganer Business NameCognition Controls Co. Email Address: [email protected]

Cover Letter(s)

Cognition Controls Co. (Date:2024/02/27) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (TA Technology (Shanghai) Co., Ltd. to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Print Name: Ty C Kartiganer Business NameCognition Controls Co. Email Address: [email protected]

External Photos

EUT Appearance Report No.: R2312A1440 TA Technology (Shanghai) Co., Ltd. TA-MB-01-032E Page 1 of 4 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. EUT Appearance EUT Appearance Report No.: R2312A1440 TA Technology (Shanghai) Co., Ltd. TA-MB-01-032E Page 2 of 4 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. EUT Appearance Report No.: R2312A1440 TA Technology (Shanghai) Co., Ltd. TA-MB-01-032E Page 3 of 4 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. a: EUT EUT Appearance Report No.: R2312A1440 TA Technology (Shanghai) Co., Ltd. TA-MB-01-032E Page 4 of 4 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. b: Battery Picture 1: Constituents of EUT

ID Label/Location Info

cognitioncontrols.com Model: CC-301 Serial: CCTHR3000100 FCC ID: 2BCO5CC301 IC: 31263-CC301 Designed and assembled in the United States.

Internal Photos

Internal photo FCC ID: 2BCO5CC301 TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 1 of 6 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Internal photo Internal photo FCC ID: 2BCO5CC301 TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 2 of 6 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Internal photo FCC ID: 2BCO5CC301 TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 3 of 6 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Internal photo FCC ID: 2BCO5CC301 TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 4 of 6 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Internal photo FCC ID: 2BCO5CC301 TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 5 of 6 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Internal photo FCC ID: 2BCO5CC301 TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 6 of 6 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.

RF Exposure Info

Prepared by: Wei Fangying Approved by: Fan Guangchang TA Technology (Shanghai) Co., Ltd. Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China TEL: +86-021-50791141/2/3 FAX: +86-021-50791141/2/3-8000 MPE TEST REPORT Applicant Cognition Controls Co. FCC ID 2BCO5CC301 Product Smart Commercial Control Brand Cognition Controls Model CC-301 Report No. R2312A1440-M1 Issue Date March 4, 2024 TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC 47 CFR Part 1 1.1310. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. MPE Test Report Report No.: R2312A1440-M1 TA Technology (Shanghai) Co., Ltd. TA-MB-01-014S Page 2 of 9 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Table of Contents 1 Test Laboratory ................................................................................................................................. 3 1.1 Notes of the Test Report ............................................................................................................ 3 1.2 Test Facility ................................................................................................................................ 3 1.3 Testing Location......................................................................................................................... 3 1.4 Laboratory Environment ............................................................................................................ 3 2 Description of Equipment Under Test ............................................................................................... 4 3 Maximum Tune up and Antenna Gain .............................................................................................. 5 4 MPE Limit .......................................................................................................................................... 6 5 RF Exposure Evaluation Result ........................................................................................................ 8 ANNEX A: The EUT Appearance ............................................................................................................. 9 MPE Test Report Report No.: R2312A1440-M1 TA Technology (Shanghai) Co., Ltd. TA-MB-01-014S Page 3 of 9 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1 Test Laboratory 1.1 Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA Technology (Shanghai) Co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2 Test Facility FCC (Designation number: CN1179, Test Firm Registration Number: 446626) TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission list of test facilities recognized to perform measurements. 1.3 Testing Location Company: TA Technology (Shanghai) Co., Ltd. Address: Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China City: Shanghai Post code: 201201 Country: P. R. China Contact: Fan Guangchang Telephone: +86-021-50791141/2/3 Fax: +86-021-50791141/2/3-8000 Website: https://www.eurofins.com/electrical-and-electronics E-mail: [email protected] 1.4 Laboratory Environment Temperature Min. = 18C, Max. = 25C Relative humidity Min. = 20%, Max. = 80% Ground system resistance < 0.5  Ambient noise is checked and found very low and in compliance with requirement of standards. Reflection of surrounding objects is minimized and in compliance with requirement of standards. MPE Test Report Report No.: R2312A1440-M1 TA Technology (Shanghai) Co., Ltd. TA-MB-01-014S Page 4 of 9 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 2 Description of Equipment Under Test Client Information Applicant Cognition Controls Co. Applicant address 68 Harrison Ave. #605, Boston, MASSACHUSETTS, USA Manufacturer Cognition Controls Co. Manufacturer address 68 Harrison Ave. #605, Boston, MASSACHUSETTS, USA General Technologies EUT Description Model CC-301 Lab internal SN R2312A1440/S01 Hardware Version V1 Software Version 1.0.0 Frequency Band TX (MHz) RX (MHz) LTE-M Band 2 1850 ~ 1910 1930 ~ 1990 LTE-M Band 4 1710 ~ 1755 2110 ~ 2155 LTE-M Band 5 824 ~ 849 869 ~ 894 LTE-M Band 12 699 ~ 716 729 ~ 746 LTE-M Band 13 777 ~ 787 746 ~ 756 LTE-M Band 25 1850 ~ 1915 1930 ~ 1995 LTE-M Band 26A 814 ~ 824 859 ~ 869 LTE-M Band 26B 824 ~ 849 869 ~ 894 LTE-M Band 66 1710 ~ 1780 2110 ~ 2180 LTE-M Band 85 698 ~ 716 728 ~ 746 Bluetooth 2400 ~ 2483.5 2400 ~ 2483.5 Wi-Fi 2.4G 2400 ~ 2483.5 2400 ~ 2483.5 Date of Sample Received December 25, 2023 Note: 1. The EUT is sent from the applicant to TA and the information of the EUT is declared by the applicant. 2. All indications of Pass/Fail in this report are opinions expressed by TA Technology (Shanghai) Co., Ltd. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. MPE Test Report Report No.: R2312A1440-M1 TA Technology (Shanghai) Co., Ltd. TA-MB-01-014S Page 5 of 9 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 3 Maximum Tune up and Antenna Gain The numeric gain (G) of the antenna with a gain specified in dB is determined by Numeric gain (G)=10^(antenna gain/10) Band Maximum Tune up Power Antenna Gain (dBi) Numeric Gain (dBm) (mW) LTE-M Band 2 22.00 158.489 1.60 1.445 LTE-M Band 4 22.00


Text truncated - open the document above for the full version.

Test Report

Prepared by: Zhu Chentao Approved by: Xu Kai TA Technology (Shanghai) Co., Ltd. Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China TEL: +86-021-50791141/2/3 FAX: +86-021-50791141/2/3-8000 RF TEST REPORT Applicant Cognition Controls Co. FCC ID 2BCO5CC301 Product Smart Commercial Control Brand Cognition Controls Model CC-301 Report No. R2312A1440-R5 Issue Date March 4, 2024 TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC CFR47 Part 15C (2023). The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. RF Test Report Report No.: R2312A1440-R5 TA Technology (Shanghai) Co., Ltd. TA-MB-04-005R Page 2 of 70 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENT 1. Test Laboratory ............................................................................................................................... 4 1.1. Notes of the Test Report ......................................................................................................... 4 1.2. Test Facility ............................................................................................................................. 4 1.3. Testing Location ...................................................................................................................... 4 2. General Description of Equipment Under Test ............................................................................... 5 2.1. Applicant and Manufacturer Information ................................................................................ 5 2.2. General Information ................................................................................................................ 5 3. Applied Standards ........................................................................................................................... 6 4. Test Configuration ........................................................................................................................... 7 5. Test Case Results ........................................................................................................................... 8 5.1. Unwanted Emission ................................................................................................................ 8 5.2. Conducted Emission ............................................................................................................. 63 6. Main Test Instruments................................................................................................................... 68 ANNEX A: The EUT Appearance ......................................................................................................... 69 ANNEX B: Test Setup Photos .............................................................................................................. 70 RF Test Report Report No.: R2312A1440-R5 TA Technology (Shanghai) Co., Ltd. TA-MB-04-005R Page 3 of 70 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Summary of Measurement Results Number Test Case Clause in FCC rules Verdict 1 Unwanted Emissions 15.247(d), 15.205, 15.209 PASS 2 Conducted Emissions 15.207 PASS Date of Testing: January 3, 2024 ~ February 19, 2024 Date of Sample Received: December 25, 2023 Note: All indications of Pass/Fail in this report are opinions expressed by TA Technology (Shanghai) Co., Ltd. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. Only Unwanted Emissions and Conducted Emissions is tested for CC-301 in this report. Other test items refer to the Module report (Report No.: R2103A0270-R1V2, FCC ID: 2AC7Z-ESPC3MINI1). RF Test Report Report No.: R2312A1440-R5 TA Technology (Shanghai) Co., Ltd. TA-MB-04-005R Page 4 of 70 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1. Test Laboratory 1.1. Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA Technology (Shanghai) Co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2. Test Facility FCC (Designation number: CN1179, Test Firm Registration Number: 446626) TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission list of test facilities recognized to perform measurements. A2LA (Certificate Number: 3857.01) TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory Accreditation to perform measurement. 1.3. Testing Location Company: TA Technology (Shanghai) Co., Ltd. Address: Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China City: Shanghai Post code: 201201 Country: P. R. China Contact: Xu Kai Telephone: +86-021-50791141/2/3 Fax: +86-021-50791141/2/3-8000 Website: https://www.eurofins.com/electrical-and-electronics E-mail: [email protected] RF Test Report Report No.: R2312A1440-R5 TA Technology (Shanghai) Co., Ltd. TA-MB-04-005R Page 5 of 70 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 2. General Description of Equipment Under Test 2.1. Applicant and Manufacturer Information Applicant Cognition Controls Co. Applicant address 68 Harrison Ave. #605, Boston, MASSACHUSETTS, USA Manufacturer Cognition Controls Co. Manufacturer address 68 Harrison Ave. #605, Boston, MASSACHUSETTS, USA 2.2. General Information EUT D


Text truncated - open the document above for the full version.

Test Report

OTA TEST REPORT TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in ANSI/IEEE Std 149-2008. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Prepared by: Peng Tao Approved by: Kai Xu TA Technology (Shanghai) Co., Ltd. No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China TEL: +86‐021‐50791141/2/3 FAX: +86‐021‐50791141/2/3‐8000 Applicant Espressif System (Shanghai) Co.,Ltd Product ESP32-C3-MINI-1 Model ESP-ANT D-H Report No. Y2102A0260-T2 Issue Date March 9, 2021 OTA Test Report Report No: Y2102A0260-T2 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 2 of 13 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENTS 1. Test Laboratory .............................................................................................................................. 3 1.1. Notes of the Test Report ................................................................................................... 3 1.2. Test facility ........................................................................................................................ 3 1.3. Testing Location ................................................................................................................ 3 1.4. Laboratory Environment .................................................................................................... 4 2. General Description of Equipment under Test ............................................................................... 5 2.1. Applicant and Manufacturer Information ............................................................................ 5 2.2. General information ........................................................................................................... 5 2.3. Test Date ........................................................................................................................... 5 2.4. Receiving Date .................................................................................................................. 5 2.5. Applied Standards ............................................................................................................. 6 3. Test Conditions .............................................................................................................................. 7 3.1. Test Configuration ............................................................................................................. 7 3.2. Test Measurement ............................................................................................................. 7 4. Test Results ................................................................................................................................... 8 4.1. Gain and Efficiency ............................................................................................................ 8 5. Equipment List ............................................................................................................................... 9 ANNEX A 3-D Pattern Plots ................................................................................................................... 10 ANNEX BThe EUT Appearance and Test Configuration ...................................................................... 12 B.1 EUT Appearance ................................................................................................................... 12 B.2 Test Configuration ................................................................................................................. 13 OTA Test Report Report No: Y2102A0260-T2 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 3 of 13 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1. Test Laboratory 1.1. Notes of the Test Report This report shall no


Text truncated - open the document above for the full version.

Contact Information

Applicant

Ty C Kartiganer(Lead Hardware Engineer)
[email protected]860-857-4604Fax: n/a

Test Firm

Eurofins TA Technology (Shanghai) Co., Ltd.Mr. Zhihui Liu
[email protected]86-21-50791141

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz71.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.