Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
lnstall the bulb in the glass lampshade ① OF F ON Wireless remote control RF01 ② 8H4H2H + - 2H 4H 8H Timer Brightness down Brightness up ON/OFF Control panel(Square or circular) ③ The warranty content is as follows: 1. One year warranty. 2.Ar tif icial damage to the appearance is not covered by the warranty. 3.Bulbs are consumables and are not covered by the warranty. CANDLE WARMER LAMP Candle warmer Lamp Manual + General safety information: Warning! Make sure that the power supply is switched off before beginning assembly! Please take note of the following symbols and safety information to prevent damage from Occurring due to improper assembly or use: Luminaires with this symbol do not require an earth wire for safe operation. This symbol shows that the luminaire should not be covered with insulation material. Assembly: The luminaire may only be connected to apower source that corresponds to the "Technical Specifications" of the uminaire. Changes: Do not make any changes to the luminaire or its connecting cable. Star t-up: Do not operate the luminaire if the luminaire itself or its connecting cable is visibly damaged. Light bulb: Only use the light bulbs specified on the luminaire. The maximum power of each light bulb must not be exceeded. Replacing the light bulb: Care instructions: switched off and make sure that moisture does not get into the terminals or on live parts. Do not use any cleaning agents as these leave marks. Anti scalding instructions: During the working process of the lamp, the bulb temperature is high, and it is strictly prohibited to touch!To prevent scalding The temperature is still h i gh w i t h i n 1 5 m i n u t e s a f t e r t u r n i n g o f f t h e l i gh t and cannot be touched. Before you replace the light bulb, make sure that the luminaire Only use the light bulb specified on the luminaire. is not connected to the power supply ! Light bulb become hot during usage. Leave them to cool down before replacing. Only clean the luminaire when it is cooled down and Description of use: 1.Install the bulb in the glass lampshade. 2.Place the bottled candle in the base groove of the base. 3.Insert the wax melting lamp power plug into the power socket, ensuring that the plug is fully in contact with the socket. 4. Touch the "Power" button on the lamp control panel with your finger, turn on the power, and use the "Dim -"/"Dim+" buttons to adjust the brightness of the light, thereby adjusting the irradiation temperature. 5. When using the remote control for the first time, it is necessary to match the code value between the remote control and the wax melting lamp. Only after successful matching can the remote control be used normally. (1)Pull out the battery electrode isolation film of the remote control to ensure normal power supply of the remote control; (2)When the wax melting lamp is in the "off " state of the power supply, long touch the "timer" button on the lamp control panel for 3-5 seconds. After both the timer and power indicator lights flash, release the button, and then long press and hold the "power" button on the remote control for about 2 seconds. At this time, the wax melting lamp is turned on, and when the light is on, the remote control function is successfully matched; (3)If the light is not on and the indicator light continues to flash, it indicates that the matching is not successful. At this time, the power supply of the wax melting lamp should be disconnected, wait for the indicator light to turn off, and then follow the steps of 5-2 to operate again. If the matching still cannot be achieved, please contact after-sales personnel for assistance in solving the problem; (4)If the light is not on and the indicator light continues to flash, it indicates that the matching is not successful. At this time, the power supply of the wax melting lamp should be disconnected, wait for the indicator light to turn off, and then follow the steps of 5-2 to operate again. If the matching still cannot be achieved, please contact after-sales personnel for assistance in solving the problem; (5)Please use the remote control correctly and repeat the code value matching every time the remote control is replaced. 2H 4H 8H Product requirements parameters: Light source: 220V/110V GU10 35W/50W*2 pcs. Height adjust: Telescopic height adjustment and left and right tightening(Figure 1). Dimming function: (Figure 2)or (Figure 3). Remote ControlControl Panel Precautions: 1. The candle's surface slowly melts for 3-5 minutes and heats it for 2-4 hours each time when electricity passes. 2. After five or six heating, the surface is filled with oil vapour and alayer of surface must be removed. You can continue to smell sweet. 3. The working principle ofa candle light is to heat it up by usinga light bulb. Never light a candle at the same time when in use. Height-adjusstable lamp pole ① T ig h t en E le vat ed Elevated Tighten CANDLE WARMER LAMP MAKE THE WASTEFUL ATMOSPHERE INSTANTLY FILL UP OPERATION INSTRUCTIONS P H R-2H G-4H B-8H POWER LED P H R-2H/G-4H/B-8H POWER LED
Foshan Nanhai district Shengyunda electronic technology factory FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date: September 8, 2023 FCCID: 2BCQM-RF Ref.#1: AttestationStatementsPart2.911(d)(5)(i)Filing (“FoshanNanhaidistrictShengyundaelectronictechnologyfactory”)certifiesthatthe equipmentforwhichauthorizationissoughtisnot“covered”equipmentprohibitedfrom receivinganequipmentauthorizationpursuanttosection2.903oftheFCCrules. Ref.#2: AttestationStatementsPart2.911(d)(5)(ii)Filing (“FoshanNanhaidistrictShengyundaelectronictechnologyfactory”)c ertifies that, as of the date of the filing of the application, the applicantis notidentified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates)as an entity producing “covered” equipment. Applicant: Foshan Nanhai district Shengyunda electronic technology factory Address:No. 405, 4th Floor, Block C, No.2 Lianhe Avenue, Luocun, Shishan Town, Nanhai District, Foshan City, Guangdong Province ContactPerson:Bingqing Li Tel:13510782848 E-mail:[email protected] Sincerely, Signature:
Foshan Nanhai district Shengyunda electronic technology factory * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 9/6/2023 ATTN.: Reviewing Engineer FCC ID: 2BCQM-RF Per section 2.911(d)(7) of the FCC rules, Foshan Nanhai district Shengyunda electronic technology factory certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: JOC Australia Inc Physical U.S. Company Address: 18351 Colima Road Ste 585 Rowland Heights,California,91748 United States of America Agent contact name/Title : Benjamin. Smith/Vice President Agent Email Address: [email protected]/[email protected] Tel No.: +1(626) 341 3408 FRN No.: 0033379421 The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Agent Signed (if different to Applicant): Signed: Signed: Printed name: Bingqing Li Printed name: Benjamin. Smith Title: Manager Title: Vice President Company Name:Foshan Nanhai district Shengyunda electronic technology factory Company Name: JOC Australia Inc Date: 9/6/2023 Date: 9/6/2023
1.AntennaDescription: AntennatypePCBantenna ModelRC401 Frequencyrange420MHz~450MHz ManufacturerShenzhenTangshangTechnologyCo.,LTD Address4018,Building34,ChentianIndustrialZone,Chentian Community,XixiangStreet,BaoanDistrict,Shenzhen 2.AntennaPhoto: 3.AntennaEfficiencyandGain: Frequency(MHz)420430440450 Efficiency(%)68.4770.5269.3874.73 Gain(dBi)0.420.460.500.47
1.AntennaDescription: AntennatypePCBantenna ModelRC401 Frequencyrange420MHz~450MHz ManufacturerShenzhenTangshangTechnologyCo.,LTD Address4018,Building34,ChentianIndustrialZone,Chentian Community,XixiangStreet,BaoanDistrict,Shenzhen 2.AntennaPhoto: 3.AntennaEfficiencyandGain: Frequency(MHz)420430440450 Efficiency(%)68.4770.5269.3874.73 Gain(dBi)0.420.460.500.47
Foshan Nanhai district Shengyunda electronic technology factory Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: September 8, 2023 Subject; Request for Confidentiality FCC ID: 2BCQM-RF To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) asconfidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Bingqing Li Title: Manager
FoshanNanhaidistrictShengyundaelectronictechnology factory No.405,4thFloor,BlockC,No.2LianheAvenue,Luocun,ShishanTown, NanhaiDistrict,FoshanCity,GuangdongProvince Productdifferencesstatement DATE:Sep.06,2023 We,FoshanNanhaidistrictShengyundaelectronictechnologyfactory,WirelessRemote Controlhasforty-fourkindsmodelRF01,RF02,RF03,RF04,RF05,RF06,RF07,RF08,RF09, RF10,RF11,RF12,RF13,RF14,RF15,RF16,RF17,RF18,RF19,RF20,RF21,RF22,RF23,RF24,R F25,RF26,RF27,RF28,RF29,RF30,RF31,RF32,RF33,RF34,RF35,RF36,RF37,RF38,RF39,RF 40,RF41,RF42,RF43,RF44.Theproductsareidenticalininteriorstructure,electricalcircuits andcomponents,justmodelnamesandcoloraredifferent. Company:FoshanNanhaidistrictShengyundaelectronictechnologyfactory Address:No.405,4thFloor,BlockC,No.2LianheAvenue,Luocun,ShishanTown,Nanhai District,FoshanCity,GuangdongProvince ContactPerson:BingqingLi/Manager Tel:13510782848 E-mail:[email protected]
Effective Date: April 2, 2020QSF 7.6.4-8 – Agent Authorization Letter TemplatePage 1 of 1 Revision Date:Revision: 0 Foshan Nanhai district Shengyunda electronic technology factory Date : 09/07/2023 Product Model Number: RF01,RF02.RF03.RF04.RF05.RF06.RF07.RF08.RF09.RF10.RF11.RF12.RF13.RF14. RF15.RF16.RF17.RF18.RF19.RF20.RF21.RF22.RF23.RF24.RF25.RF26.RF27.RF28.RF29.RF30.RF31.RF32.RF33.RF34. RF35,RF36,RF37,RF38,RF39,RF40,RF41,RF42,RF43,RF44 FCC ID : 2BCQM-RF To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: Testing Approval applications and procedures We declare thatORGANIZATION. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out byORGANIZATION. on our behalf shall have the same effect as acts of our own. By: Bingqing Li Contact Listed on FCC Wesbite Title:Manager Email: [email protected] On behalf of: Foshan Nanhai district Shengyunda electronic technology factory
FCCID:2BCQM-RF ExternalPhotosoftheEUT Fig.1 Fig.2 FCCID:2BCQM-RF Fig.3 Fig.4 FCCID:2BCQM-RF Fig.5 Fig.6
FCCID:2BCQM-RF labelandlocation Fig.1 FCCID:2BCQM-RF WirelessRemoteControl Model:RF01 Input:DC3.0V FoshanNanhaidistrictShengyundaelectronictechnology factory
FCCID:2BCQM-RF InternalPhotosoftheEUT Fig.1 Fig.2 Antenna FCCID:2BCQM-RF Fig.3
Page 1 of 2 RFExposureevaluation FCCID:2BCQM-RF 1.1.ApplicableStandard Accordingto§1.1307(b)(1),systemsoperatingundertheprovisionsofthissectionshallbeoperatedina mannerthatensuresthatthepublicisnotexposedtoradiofrequencyenergylevelinexcessofthe Commission’sguidelines. Accordingto§1.1310and§2.1093RFexposurerequirement KDB447498v06:MobileandPortableDevicesRFExposureProceduresandEquipmentAuthorization Policies 1.2.Requirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06Section4.3.1StandaloneSARtest exclusionconsiderations:“UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures, standalone1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposureconditions, bymeasurementornumericalsimulation,isnotrequiredwhenthecorrespondingSARTestExclusion Thresholdcondition,listedbelow,issatisfied.Thesetestexclusionconditionsarebasedonsource-based time-averagedmaximumconductedoutputpoweroftheRFchannelrequiringevaluation,adjustedfortune-up tolerance,andtheminimumtestseparationdistancerequiredfortheexposureconditions.22Theminimum testseparationdistanceisdeterminedbythesmallestdistancefromtheantennaandradiatingstructuresor outersurfaceofthedevice,accordingtothehostformfactor,exposureconditionsandplatformrequirements, toanypartofthebodyorextremityofauserorbystander(see5)ofsection4.1).ToqualifyforSARtest exclusion,thetestseparationdistancesappliedmustbefullyexplainedandjustifiedbytheoperating configurationsandexposureconditionsofthetransmitterandapplicablehostplatformrequirements,typically intheSARmeasurementorSARanalysisreport,accordingtotherequiredpublishedRFexposureKDB procedures.WhennootherRFexposuretestingorreportingisrequired,astatementofjustificationand compliancemustbeincludedintheequipmentapproval,inlieuoftheSARreport,toqualifyfortheSARtest exclusion.Whenrequired,thedevicespecificconditionsdescribedintheotherpublishedRFexposureKDB proceduresmustbesatisfiedbeforeapplyingtheseSARtestexclusionprovisions;forexample,handheldPTT two-wayradios,handsets,laptops&tabletsetc.23“ [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance,mm)] · [√f(GHz)] ≤3.0for1-gSARand≤7.5for10-gextremitySAR,where: •f(GHz)istheRFchanneltransmitfrequencyinGHz •PoweranddistanceareroundedtothenearestmWandmmbeforecalculation •Theresultisroundedtoonedecimalplaceforcomparison • 3.0and7.5arereferredtoasthenumericthresholdsinthestep2below Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis ≤ 50mmandfor transmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtestseparationdistanceis<5 mm,adistanceof5mmaccordingto5)insection4.1isappliedtodetermineSARtestexclusion. 1.3.Manufacturingtolerance Freq. (MHz) Fieldstrength(max)(dBuV/m) EIRP(max) (dBm) Turn-upPower (dB) Maxtuneup power (dBm) [P] 433.947074.64 -20.62-20.0±1-19.0 Note: EIRP=E-104.8+20logD,D=3 Page 2 of 2 2.EvaluationResult EvaluationResults Band/Modef(GHz) Antenna Distance (mm) RFoutputpower (includingtune-up tolerance) SARTest Exclusion Threshold SARTest Exclusion dBmmW SRD0.4335-19.0 0.0126 0.0017<3.0Yes 3.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1093fortheuncontrolledRFExposure andSARExclusionThresholdperKDB447498v06. .....................EndofReport.........................
ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. 101#,BuildingK&BuildingT,TheSecondIndustrialZone,JiazitangCommunity, FenghuangStreet,GuangmingDistrict,Shenzhen,China FCCPART15SUBPARTCTESTREPORT FCCPART15.231 ReportReferenceNo........................: FCCID. ................................................ : GRCTR230802030-01 2BCQM-RF Compiledby (position+printedname+signature) .. : TestingEngineerJimmyWang Supervisedby (position+printedname+signature)..: ProjectEngineerKelleyZhang Approvedby (position+printedname+signature) .. : ManagerSamWang Dateofissue.........................................:Sep.08,2023 TestingLaboratoryName................: ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. Address ................................................. : 101#,BuildingK&BuildingT,TheSecondIndustrialZone, JiazitangCommunity,FenghuangStreet,GuangmingDistrict, Shenzhen,China Applicant’sname ............................... :FoshanNanhaidistrictShengyundaelectronictechnology factory Address.................................................: No.405,4thFloor,BlockC,No.2LianheAvenue,Luocun,Shishan Town,NanhaiDistrict,FoshanCity,GuangdongProvince Testspecification .............................. : Standard................................................:FCCPart15.231 ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.isacknowledgedascopyrightownerand sourceofthematerial.ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.takesno responsibilityforandwillnotassumeliabilityfordamagesresultingfromthereader'sinterpretationofthe reproducedmaterialduetoitsplacementandcontext. Testitemdescription........................:WirelessRemoteControl TradeMark............................................:/ Manufacturer ......................................... :FoshanNanhaidistrictShengyundaelectronictechnology factory Model/Typereference.........................:RF01 ListedModels ...................................... : RF02,RF03,RF04,RF05,RF06,RF07,RF08,RF09,RF10,RF11,RF12, RF13,RF14,RF15,RF16,RF17,RF18,RF19,RF20,RF21,RF22,RF23, RF24,RF25,RF26,RF27,RF28,RF29,RF30,RF31,RF32,RF33,RF34, RF35,RF36,RF37,RF38,RF39,RF40,RF41,RF42,RF43,RF44 Ratings ................................................... :Buttoncell3.0V Modulation...........................................:ASK Frequency..............................................433.9470MHz Result.....................................................:PASS ReportNo.:GRCTR230802030-01Page 2 of 21 TESTREPORT EquipmentunderTest: WirelessRemoteControl Model/Type: RF01 ListedModels: RF02,RF03,RF04,RF05,RF06,RF07,RF08,RF09,RF10,RF11,R F12,RF13,RF14,RF15,RF16,RF17,RF18,RF19,RF20,RF21,RF2 2,RF23,RF24,RF25,RF26,RF27,RF28,RF29,RF30,RF31,RF32, RF33,RF34,RF35,RF36,RF37,RF38,RF39,RF40,RF41,RF42,R F43,RF44 Applicant: FoshanNanhaidistrictShengyundaelectronictechnology factory Address: No.405,4thFloor,BlockC,No.2LianheAvenue,Luocun, ShishanTown,NanhaiDistrict,FoshanCity,Guangdong Province Manufacturer: FoshanNanhaidistrictShengyundaelectronictechnology factory Address: No.405,4thFloor,BlockC,No.2LianheAvenue,Luocun, ShishanTown,NanhaiDistrict,FoshanCity,Guangdong Province TestResult:PASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. ReportNo.:GRCTR230802030-01Page 3 of 21 Contents 1TESTSTANDARDS..............................................................................................................................4 2SUMMARY.................................................................................................................................................5 2.1GeneralRemarks..........................................................................................................................................5 2.2ProductDescription.....................................................................................................................................5 2.3EquipmentUnderTest.................................................................................................................................5 2.4ShortdescriptionoftheEquipmentunderTest(EUT).............................................................................5 2.5BlockDiagramofTestSetup.......................................................................................................................5 2.6SpecialAccessories.....................................................................................................................................6 2.7RelatedSubmittal(s)/Grant(s)...................................................................................................................6 2.8Modifications.................................................................................................................................................6 3TESTENVIRONMENT........................................................................................................................7 3.1Addressofthetestlaboratory....................................................................................................................7 3.2TestFacility...................................................................................................................................................7 3.3Environmentalconditions............................................................................................................................7 3.4Summaryofmeasurementresults..............................................................................................................8 3.5Statementofthemeasurementuncertainty..............................................................................................8 3.6EquipmentsUsedduringtheTest..................................................................................................…
Text truncated - open the document above for the full version.
FCCID:2BCQM-RF TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.947 MHz - 433.947 MHz | - |