Instruction Manual Electric Patio Heater ZHQ1848-SPK-RM IMPORTANT RETAIN FOR FURTHER REFERENCE READ CAREFULLY ! Please read these instructions carefully before using your new halogen heater FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Unpack the heater making sure that all the items are present and that there are no components left in the box and that the heater head is free from any packing material. Using the detailed drawing and follow the steps to assemble your heater. Do not connect the heater to the electrical supply until all the assembly is complete. Do not connect the heater to the electrical supply if any of the components or the power cord is damaged in any way. If in doubt contact your supplier. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. WARNING: This heater is not equipped with a device to control the room temperature. Do not use this heater in small rooms when they are occupied by persons not capable of leaving the room on their own, unless constant supervision is provided. Children of less than 3 years should be kept away unless continuously supervised. Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance. CAUTION — Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present. Caution Only use the heater on a firm solid horizontal area where all the feet on the base are in contact with the floor. (Should the heater be tilted or fall over the auto cut off switch will activate) 1. Site the heater outside or in a large open area and well away from any obstructions such as branches or where the heater is near any objects that can be effected by heat, such as furniture, curtains or other inflammable objects (minimum distance 1 meter). 2. Do not use near bath tubs, wash areas or swimming pools. 3. Do not use in unventilated areas 4. Do not use where gas, petrol, paint or other inflammable goods are stored. 5. Do not push any items through, obstruct or cover the grill of the heater head. 6. Do not position immediately above or below an electrical socket. 7. Do not move when connected to an electrical supply and always wait for the patio heater to cool down before storing away. 8. Do not touch the heater head when in use. 9. Do not leave turned on and unattended especially when children and or animals are in the vicinity. 10. The indication of the different positions of switches shall be visible from a distance of 1M. 11. The Marking concerning covering shall be visible after the heater has been installed. It shall not be placed on the back of portable heaters. 12. The unit must be placed with the clearance of 100cm to the wall. 13. The unit must be correctly installed according to the instructions. 14. The unit must be securely placed on a horizontal and flat surface. 15. The unit is at high temperature during operation. It keeps hot for a period after shut down. Potential danger would occur when touching it during this period. 16. Don’t place the unit closed to curtain and/or other flammable objects. Otherwise there will be a danger of catching fire. 17. Don’t cover the unit with anything during operation or a short time after it’s shut down. 18. Don’t wrap the power supply cord on the unit. 19. The unit must be handled with care, and avoid vibration or hitting. 20. The unit must be securely grounded during operation. 21. If the unit gets damaged, it must be repaired by professional electricians. 22. When the power supply cord is damaged, it must be replaced by authorized agent or other professional people to avoid danger. 23. The unit must not be positioned under a socket. 24. When assembling, keep clear from any board or flammable material. 25. The unit must be supervised by adults if it’s used by a child. 26. It is not safe to install the unit by a swimming pool, in a bathroom or shower area. 27. The unit is for household use only. It is not safe to use on a building site, greenhouse, barn or stable where there’s flammable dust. 28. The head of the unit is at high temperature during operation. Unplug the unit and wait till it cools before cleaning. 29. Don’t use this unit in place where causticity or volatile air exists, i.e. dust, steam, gas, etc. 30. Don’t use this unit as a cloth drier or towel drier. 31. Don’t use this unit as a sauna heater. 32. Don’t use this unit as a room heater. 33. Don’t use this unit in place of animal propagating and raising. 34. Don’t immerse this unit into water for cleaning. 35. The unit should be plugged in a socket, which is easily visible and reachable. 36. One dark point may exist on the surface of the heating elements during the first few minutes after it is turned on. This is normal, and will not affect the performance of the unit. 37. The heater must not be located immediately below a socket-outlet. 38. Do not use this heater in the immediate surroundings of a bath, a shower or a swimmi…
Text truncated - open the document above for the full version.
Zhuhai Special Economic Zone Runwin Electric Co.,Ltd U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name: United Consulting Technology Services Co., Ltd. FRN: 0033495714 Contact Name: David Wu Street Address: 17800 CASTLETON ST STE 665 CITY OF INDUSTRY CA 91748 United States Telephone No: (626) 217-4022 Email: [email protected] This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature: Date: 2023/9/20 Signed by (Printed Name/Title): David Wu/CEO The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: Zhuhai Special Economic Zone Runwin Electric Co.,Ltd Grantee Code: 2BCTU FCC ID: 2BCTU-ZHQ1848 Contact Name: jiawei Sun Street Address: Qinshi Industrial Zone #33, Sanzao City/Province/Zip: zhuhai, Telephone No: 13825652128 Email: [email protected] Applicant Signature: Date: 2023/9/20 Signed by (Printed Name/Title): jiawei Sun / General manager
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 1 of 6 Appendix External Photos for GZCR2307000774HS Test Model No.: ZHQ1848-SPK-RM SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 2 of 6 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 3 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 4 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 5 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 6 of 6
ELECTRIC PATIO HEATER Model:ZHQ1848-SPK-RM Power supply:120V 60Hz power consumption:1500W Degree of protection:IP55 MADE IN CHINA MMYY Zhuhai Special Economic Zone Runwin Electric Co ., Ltd. SUITABLE FOR WET LOCATIONS CONVIENT AUX EMPLACEMENTS MOUILLés FCC ID: 2BCTU-ZHQ1848 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 1 of 7 Appendix Internal Photos for GZCR2307000774HS Test Model No.: ZHQ1848-SPK-RM SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 2 of 7 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 3 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 4 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 5 of 7 RF ANT SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 6 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 7 of 7
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230700077403 Page: 1 of 8 FCC ID: 2BCTU-ZHQ1848 Ricky Liu Manager RF EXPOSURE EVALUATION REPORT Application No.: GZCR2307000774HS Applicant:ZHUHAI SPECIAL ECONOMIC ZONE RUNWIN ELECTRIC CO., LTD Address of Applicant:QINSHI INDUSTRIAL ZONE, NO.33 SANZAO TOWN, ZHUHAI, 519040, GUANGDONG PROVINCE, CHINA. Manufacturer:ZHUHAI SPECIAL ECONOMIC ZONE RUNWIN ELECTRIC CO., LTD Address of Manufacturer:QINSHI INDUSTRIAL ZONE, NO.33 SANZAO TOWN, ZHUHAI, 519040, GUANGDONG PROVINCE, CHINA. Factory:ZHUHAI SPECIAL ECONOMIC ZONE RUNWIN ELECTRIC CO., LTD Address of Factory:QINSHI INDUSTRIAL ZONE, NO.33 SANZAO TOWN, ZHUHAI, 519040, GUANGDONG PROVINCE, CHINA. Equipment Under Test (EUT): EUT Name:ELECTRIC PATIO HEATER Model No.: ZHQ1848-SPK-RM Standard(s) : 47 CFR Part 1.1310 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2023-07-26 Date of Evaluation: 2023-08-25 Date of Issue: 2023-09-05 Evaluation Result: Pass* * In the configuration evaluated, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230700077403 Page: 2 of 8 Revision Record VersionReport No.DateRemark 01GZCR2307000774032023-09-05Original Authorized for issue by: Michael Huang/Project Engineer Vico Cui/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230700077403 Page: 3 of 8 2Evaluation Summary ItemStandardMethodRequirementResult RF Exposure KDB447498D01 General RF Exposure Guidance v06 KDB447498D01 General RF Exposure Guidance v06 47 CFR Part 1.1310Pass Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230700077403 Page: 4 of 8 3Contents Page 1Cover Page...............................................................................................................................................1 2Evaluation Summary................................................................................................................................3 3Contents....................................................................................................................................................4 4General Information.................................................................................................................................5 4.1Details of E.U.T.................................................................................................................................5 4.2Evaluating Location...........................................................................................................................5 4.3Facility...............................................................................................................................................6 4.4Deviation from Standards..................................................................................................................6 4.5Abnormalities from Standard Conditions...........................................................................................6 5Technical Requirements Specification..................................................................................................7 5.1RF Exposure Evaluation....................................................................................................................7 5.1.1Limit & Test Method......................................................................................................................7 5.1.2Conclusion....................................................................................................................................7 6EUT Constructional Details (EUT Photos).............................................................................................8 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230700077403 Page: 5 of 8 4General Information 4.1Details of E.U.T. Power supply:AC 120V, 60Hz Cable(s):3 wires x about 1.8m unscreened AC mains cable. Operation Frequency:2402MHz to 2480MHz Bluetooth Version:V5.0 classic only Modulation Type:GFSK, π/4DQPSK Number of Channels:79 Channel Spacing:1MHz Spectrum Spread Technology: Frequency Hopping Spread Spectrum(FHSS) Antenna Type:PIFA Antenna Gain:1.9 dBi 4.2Evaluating Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou Branch EMC Laboratory, 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, China 510663 Tel: +86 20 82155555Fax: +86 20 82075059 No tests were sub-contracted. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230700077403 Page: 6 of 8 4.3Facility The facility is recognized, certified, or accredited by the following organizations: ● ACMA SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory can also perform testing for the Australian/New Zealand Regulatory Compliance Mark (RCM). ● SGS UK(Certificate No.: 32), SGS-TUV SAARLAND and SGS-FIMKO Have approved SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory as a supplier of EMC TESTING SERVICES and SAFETY TESTING SERVICES. ● FCC Recognized Accredited Test Firm(Registration No.: 486818) SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been accredited and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Designation Number: CN5016, Test Firm Registration Number: 486818. ● ISED (Registration No.: 4620B, CAB identifier: CN0052) SGS-CSTC Standards Technical Services Co., Ltd., has been registered by Innovation Science a…
Text truncated - open the document above for the full version.
Product specification Quick Reference Date Antenna module on the system board Frequenc Range 2400 ~ 2500MHz Ant. Port Input Pwr. (dBm) 0 (Typ. BT class 2 output power) Tot. Rad. Pwr. (dBm) -1.2 (Input pwr – loss pwr) Peak EIRP(dBm) 1.2 Directivity (dBi) 1 (all direction antenna) Efficiency (dB) 6 0.2 % Gain (dBi) 1.2 (Avg Gain XY-plane) Maximum Power (dBm) 1.7 (XY-plane) Minimum Power (dBm) -4(XY-plane) Avg. Power (dBm) -0.5(XY-plane) Input Impendence(ohm) 50 Polarization Type V ertical & Horizontal V . S .W . R < 1.4 All the technical data and information contained herein are subject to ch ange without prior notice Antenna Layout & module on the system board Antenna Gain Gain Table Unit in dBi @2.44GHz XY-plane XZ-plane YZ-plane Efficiency Peak Avg. Peak Avg. Peak Avg. Module Board 1.2 -0.5 1.9 -3.6 1.1 -3.0 6 0.2 % KingRuiTeng Technologyco.,ltd A602, Building 168-8, Huantian Road, Tianliao, Yutang Street, Guangming New District, Shenzhen, Guangdong, China Retum Loss The Environment of Antenna Radiation Pattem 3D radiation pattern diagram XY-plane XZ-plane YZ-plane
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230700077402 Page: 1 of 80 FCC ID: 2BCTU-ZHQ1848 Ricky Liu Manager TEST REPORT Application No.: GZCR2307000774HS Applicant: ZHUHAI SPECIAL ECONOMIC ZONE RUNWIN ELECTRIC CO., LTD Address of Applicant: QINSHI INDUSTRIAL ZONE, NO.33 SANZAO TOWN, ZHUHAI, 519040, GUANGDONG PROVINCE, CHINA. Manufacturer: ZHUHAI SPECIAL ECONOMIC ZONE RUNWIN ELECTRIC CO., LTD Address of Manufacturer: QINSHI INDUSTRIAL ZONE, NO.33 SANZAO TOWN, ZHUHAI, 519040, GUANGDONG PROVINCE, CHINA. Factory: ZHUHAI SPECIAL ECONOMIC ZONE RUNWIN ELECTRIC CO., LTD Address of Factory: QINSHI INDUSTRIAL ZONE, NO.33 SANZAO TOWN, ZHUHAI, 519040, GUANGDONG PROVINCE, CHINA. Equipment Under Test (EUT): EUT Name: ELECTRIC PATIO HEATER Model No.: ZHQ1848-SPK-RM Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2023-07-26 Date of Test: 2023-07-31 to 2023-08-18 Date of Issue: 2023-09-05 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230700077402 Page: 2 of 80 Revision Record Version Report No. Date Remark 01 GZCR230700077402 2023-09-05 Original Authorized for issue by: Michael Huang/Project Engineer Vico Cui/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230700077402 Page: 3 of 80 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Other requirements Frequency Hopping Spread Spectrum System Hopping Sequence N/A 47 CFR Part 15, Subpart C 15.247(a)(1),(g),(h) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass Conducted Peak Output Power ANSI C63.10 (2013) Section 7.8.5 47 CFR Part 15, Subpart C 15.247(b)(1) Pass 20dB Bandwidth ANSI C63.10 (2013) Section 7.8.7 47 CFR Part 15, Subpart C 15.247(a)(1) Pass Carrier Frequencies Separation ANSI C63.10 (2013) Section 7.8.2 47 CFR Part 15, Subpart C 15.247a(1) Pass Hopping Channel Number ANSI C63.10 (2013) Section 7.8.3 47 CFR Part 15, Subpart C 15.247a(1)(iii) Pass Dwell Time ANSI C63.10 (2013) Section 7.8.4 47 CFR Part 15, Subpart C 15.247a(1)(iii) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 7.8.6 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 7.8.8 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230700077402 Page: 4 of 80 3 Contents Page 1 Cover Page ................................................................................................................................................ 1 2 Test Summary ........................................................................................................................................... 3 3 Contents .................................................................................................................................................... 4 4 General Information .................................................................................................................................. 6 4.1 Details of E.U.T. ................................................................................................................................. 6 4.2 Description of Support Units .............................................................................................................. 6 4.3 Measurement Uncertainty .................................................................................................................. 7 4.4 Test Location ...................................................................................................................................... 7 4.5 Test Facility ........................................................................................................................................ 7 4.6 Deviation from Standards ................................................................................................................... 8 4.7 Abnormalities from Standard Conditions ........................................................................................... 8 5 Equipment List .......................................................................................................................................... 9 6 Radio Spectrum Technical Requirement ............................................................................................. 13 6.1 Antenna Requirement ...................................................................................................................... 13 6.1.1 Test Requirement: ....................................................................................................................... 13 6.1.2 Conclusion ................................................................................................................................... 13 6.2 Other requirements Frequency Hopping Spread Spectrum System Hopping Sequence ............... 14 6.2.1 Test Requirement: ........................…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 1 of 3 Appendix Test Setup Photo for GZCR230700077402 Test Model No.: ZHQ1848-SPK-RM SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 2 of 3 Test Setup Photo Conducted Emissions at AC Power Line (150kHz-30MHz) Radiated Emissions which fall in the restricted bands & Radiated Spurious Emissions Above 1GHz SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 3 of 3 Radiated Spurious Emissions Below 1GHz
No.198 Kezhu Road, · Guangzhou, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.28 mW |