FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Dongguan Taishen Electronics Co., Ltd./
  3. 2BCU9-TS3001

2BCU9-TS3001Wireless Charging Night Light Alarm Clock

Dongguan Taishen Electronics Co., Ltd.
Wireless Charging Night Light Alarm Clock - FCC ID 2BCU9-TS3001 - Dongguan Taishen Electronics Co., Ltd.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Sep 17, 2023
Application Purpose
Original Equipment
Date of Application
Sep 17, 2023
Equipment Note
Wireless Charging Night Light Alarm Clock
Frequency Range
0.11000000 - 0.14800000
Company
Dongguan Taishen Electronics Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. I f this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Note:TheGranteeisnotresponsibleforchangmodifications not expressly approved by modifications could void the user's authority to exposure requirement. guidelines, the distance must be at least 20 cm supported by the operating and installation FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. such modifications could void the user's authority to operate the equipment. The device has been evaluated to meet general RF exposure requirement. To maintain compliance with FCC's RF exposure guidelines, the distance must be at least 20 cm between the radiator and your body, and fully supported by the operating and installation configurations of the transmitter and its antenna(s).

Attestation Statements

DongguanTaishenElectronicsCo.,Ltd. 4thFloor,No.1,Alley5,DihaoStreet,Baiguodong,ZhangmutouTown,Dongguan,Guangdong,C hina Date:2023-09-13 FederalCommunicationsCommission AuthorizationandEvaluationDivision 1435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2BCU9-TS3001 DongguanTaishenElectronicsCo.,Ltd.certifiesthat,asofthedateofthefilingofthe application,GSSSERVICEINCisourdesignatedU.S.agentforserviceofprocessforthe abovereferencedFCCID.DongguanTaishenElectronicsCo.,Ltd.acceptstomaintainan agentfornolessthanoneyearafterthegranteehasterminatedallmarketingandimportation ortheconclusionofanyCommission-relatedproceedinginvolvingtheequipment. GSSSERVICEINCaccepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: Name:GSSSERVICEINC Address:6547NAcademyBlvd#2266ColoradoSpringsCOLORADO80918UnitedStates FRN0033402082 ContactPerson:MichouxLogan Tel.:001-949-2990192 Email:[email protected] Sincerely, Signedonbehalfof DongguanTaishenElectronicsCo.,Ltd. SignedonbehalfofGSSSERVICEINC Name:qibinHuangName:MichouxLogan Title:OwnerTitle:Manager Date:2023-09-15Date:2023-09-15

Attestation Statements

DongguanTaishenElectronicsCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:September13,2023 FCCID:2BCU9-TS3001 Ref.#1:AttestationStatementsPart2.911(d)(5)(i)Filing DongguanTaishenElectronicsCo.,Ltd..certifiesthattheequipmentforwhichauthorization issoughtisnot“covered”equipmentprohibitedfromreceivinganequipmentauthorization pursuanttosection2.903oftheFCCrules. Ref.#2:AttestationStatementsPart2.911(d)(5)(ii)Filing DongguanTaishenElectronicsCo.,Ltd..certifiesthat,asofthedateofthefilingof theapplication,theapplicantisnotidentifiedontheCoveredListasanentity producing“covered”equipment. Applicant:DongguanTaishenElectronicsCo.,Ltd.Address:Room103,building2,No.2, JiaojiaoRoad,XiegangTown,DongguanCity,Guangdong ContactPerson:qibinHuang Email:[email protected] Telephone:+8613662755156 Sincerely, Signature:

Cover Letter(s)

DongguanTaishenElectronicsCo., Ltd. DateSeptember11, 2023 ProductModelNumber:TS-3001,TS-3002,TS-3003,TS-3004,TS-3005, TS-3006,TS-3007,TS-3008,TS-3009 FCC ID: 2BCU9-TS3001 To whomit may concern, Re:ProductCertificationRepresentativeAuthorizationLetter We authorizeQAI LaboratoriesLtd. 3980 North FraserWay, BurnabyB.C. CanadaV5J 5K5 to act on our behalfon all mattersconcerningthe above namedequipment. This shall includethe following: Testing Approvalapplicationsand procedures We declare that ORGANIZATION. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by ORGANIZATION. on our behalf shall have the same effect as acts of our own. By: ContactListedon FCC Wesbite Title: Owner Email:[email protected] Telephone:+86 13662755156 On behalfof: DongguanTaishenElectronicsCo., Ltd.

Cover Letter(s)

DongguanTaishenElectronicsCo.,Ltd.OfficeofOwnering Technology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:September13,2023 Subject;RequestforConfidentiality FCCID:2BCU9-TS3001 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:qibinHuang Title:Owner

Cover Letter(s)

DongguanTaishenElectronicsCo.,Ltd. ModelDifference Productdescription:WirelessChargingNightLightAlarmClock Modelname:TS-3001 TS-3002,TS-3003,TS-3004,TS-3005,TS-3006,TS-3007,TS-3008,TS-3009 FCCID:2BCU9-TS3001 AllmodelsusethesamecircuitandRFmodule,butthemodelnameandexterior coloraredifferent,andalltestsarebasedontheTS-3001. Regards Sincerely Client’ssignature: Client’sname/title:qibinHuang/Owner Contactinformation/address: DongguanTaishenElectronicsCo.,Ltd.4thFloor,No.1,Alley5,DihaoStreet,Baiguo dong,ZhangmutouTown,Dongguan,Guangdong,China

External Photos

FCCID:2BCU9-TS3001 EUTPHOTOS(ExternalPhotos) FCCID:2BCU9-TS3001 FCCID:2BCU9-TS3001 FCCID:2BCU9-TS3001 FCCID:2BCU9-TS3001 FCCID:2BCU9-TS3001 FCCID:2BCU9-TS3001 ※※※※※ENDOFREPORT※※※※※

ID Label/Location Info

Page1of4 SPECIFICATION ManufacturerDongguanTaishenElectronicsCo.,Ltd. Address 4thFloor,No.1,Alley5,DihaoStreet,Baiguodong,Zha ngmutouTown,Dongguan,Guangdong,China Productname:MPA2-10uH Modelname:MPA2-10uH DATE:2023/06/06 Version:A.0 Page2of4 VersionChangeHistory Rev.BeforeChangeAfterChange ChangeDate ApprovedBy A.0 newissue ----2023/06/06 Page3of4 SPECIFICATION DESC Ί19.5x45-6.5uH-0.1x24PX2P-45mmRevA.0 侀、DIMENSION:(mm) äșŒă€SCHEMATICDIAGRAM: A 49.5±0.25 B 45±1 C 19.5±0.5 D 5.5±0.3 E 3±1 S 45±2 Note: 1.Crossoutgoingline; 2.Wrap7mm(ref)widehigh- temperatureadhesivetape1- 2Tsaroundtheoutletposition; 3.Thecoilisattachedtoa circularhardmagneticdisk withslots,withamagneticdisk sizeof49.5±0.25mm,an innerholeof5.5mm,anda thicknessof1.0±0.1mm. Thetotalthicknessis2.2± 0.2mm Page4of4 侉、WindingSpecification: NO.TERMINALWIRETurnsWindingDirection 1SFHotairline 0.1*24PX2 10Ts 曛、ELECTRICALCHARACTERISTICS: TEMPERATURE:25±10°C,RELATIVEHUMIDITY:65±20% NO.ITEMTERMINALSPECIFICATIONTESTFREQUENCYTESTEQUIPMENTS 1IND.S-F3.8 u H±20%Individualcoil100KHz/1.0VLCZMETER1062B 2IND.S-F6.5uH±10%Addingmagnetic disks 100KHz/1.0VLCZMETER1062B 3DCRS-F≀90mΩ100KHz/1.0VLCZMETER502B 4QS-F≄39100KHz/1.0VLCZMETER502B PREPAREDBY/DATECHECKEDBY/DATE 2023/06/062023/06/06

ID Label/Location Info

Size:46mm*25mm FCCID:2BCU9-TS3001

Internal Photos

FCCID:2BCU9-TS3001 EUTPHOTO(InternalPhotos) FCCID:2BCU9-TS3001 FCCID:2BCU9-TS3001 FCCID:2BCU9-TS3001 FCCID:2BCU9-TS3001 FCCID:2BCU9-TS3001 FCCID:2BCU9-TS3001 ANT FCCID:2BCU9-TS3001 FCCID:2BCU9-TS3001 FCCID:2BCU9-TS3001 ※※※※※ENDOFREPORT※※※※※

RF Exposure Info

FCCID:2BCU9-TS3001 ProductName:WirelessChargingNightLightAlarmClock ProductModelNo.:TS-3001 TS-3002,TS-3003,TS-3004,TS-3005,TS-3006,TS-3007,TS-3008, TS-3009 ModelDifference:AllmodelsusethesamecircuitandRFmodule,butthemodelnameand exteriorcoloraredifferent,andalltestsarebasedontheTS-3001. TestAuxiliary:SmartphoneandPoweradapter Transmittingmode:KeeptheEUTincontinuouslywirelesschargingmode Powersupply:Input:9V3A(27W) USB-Aoutput:5V1A Wirelesschargingoutput:5Wor7.5Wor10Wor15WMax TestModes: Mode1Wirelesschargingmode(15W) Mode2Wirelesschargingmode(10W) Mode3Wirelesschargingmode(7.5W) Mode4Wirelesschargingmode(5W) Note:Allmodesweretested,onlytheworst-casewasrecordedinthereport.Mode1istheworstmode. RFExposureEvaluation 1MeasuringStandard KDB680106RFExposureWirelessChargingAppsv03r01 2Requirements Accordingtotheitem5ofKDB680106v03r01: Inductivewirelesspowertransferapplicationsthatmeetallofthefollowingrequirementsareexcludedfrom submittinganRFexposureevaluation. (1)Powertransferfrequencyislessthan1MHz. (2)Outputpowerfromeachprimarycoilislessthanorequalto15watts. (3)Thesystemmayconsistofmorethanonesourceprimarycoils,chargingoneormoreclients.Ifmorethan oneprimarycoilispresent,thecoilpairsmaybepoweredonatthesametime. (4)Clientdeviceisplaceddirectlyincontactwiththetransmitter. (5)Mobileexposureconditionsonly(portableexposureconditionsarenotcoveredbythisexclusion). (6)TheaggregateH-fieldstrengthsanywhereatorbeyond15cmsurroundingthedevice,and20cmaway fromthesurfacefromallcoilsthatbydesigncansimultaneouslytransmit,andwhilethosecoilsare simultaneouslyenergized,aredemonstratedtobelessthan50%oftheapplicableMPElimit. Remark:Meetalltheaboverequirements. Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) 3TestSetup 4TestProcedure 1)TheRFexposuretestwasperformedinanechoicchamber. 2)Themeasurementprobewasplacedattestdistance(15cmfromallsidesand20cmfromthetop)whichis betweentheedgeofthechargerandthegeometriccenterofprobe. 3)Thehighestemissionlevelwasrecordedandcomparedwithlimitassoonasmeasurementofeachpoints (A,B,C,D,E)werecompleted. 4)TheEUTwasmeasuredaccordingtothedictatesofKDB680106v03r01. RemarkTheEUT’stestpositionA,B,C,DandEisvalidfortheEandHfieldmeasurements. 5TestInstrumentslist TestEquipmentManufacturerModelNo.SN. Cal.Date (mm-dd-yy) Cal.Duedate (mm-dd-yy) ExposureLevelTesterNardaELT-400N-0231May12,2023May11,2024 Magneticfieldprobe 100cm 2 NardaELTprobe100cm 2 M0675May12,2023May11,2024 IsotropicElectricfield probe NardaEP-601611WX70332May12,2023May11,2024 6TestResult Wehaveevaluated1%,50%and99%batterychargingmode,andtheworstmode(1%)is showedinthisreport. E-FiledStrengthat15cmfromtheedgessurroundingtheEUT(V/m) FrequencyRange (MHz) Test PositionA Test PositionB Test PositionC Test PositionD Limits (V/m) 0.110-0.1480.500.540.550.53614 E-FiledStrengthat20cmfromthetopoftheEUT(V/m) FrequencyRange (MHz) Test PositionE Limits (V/m) 0.110-0.1480.52614 H-FiledStrengthat15cmfromtheedgessurroundingtheEUT(A/m) FrequencyRange (MHz) Test PositionA Test PositionB Test PositionC Test PositionD Limits (A/m) 0.110-0.1480.110.110.100.111.63 H-FiledStrengthat20cmfromthetopoftheEUT(A/m) FrequencyRange (MHz) Test PositionE Limits (A/m) 0.110-0.1480.141.63 7TestPhoto

Test Report

ProjectNo.:ZHT-230913002E Page 1 of 23 FCCTESTREPORT FCCID:2BCU9-TS3001 ReportNumber...................................:ZHT-230913002E DateofTest ....................................................... : Sep.13,2023toSep.15,2023 Dateofissue.........................................: Sep.15,2023 TestResult..........................................: PASS TestingLaboratory............................:GuangdongZhonghanTestingTechnologyCo.,Ltd. Address ............................................... : Room104,Building1,YibaolaiIndustrialPark,QiaotouCommunity, FuhaiStreet,Bao'anDistrict,Shenzhen,Guangdong,China Applicant'sname.............................: DongguanTaishenElectronicsCo.,Ltd. Address ............................................... : 4thFloor,No.1,Alley5,DihaoStreet,Baiguodong,ZhangmutouTo wn,Dongguan,Guangdong,China Manufacturer'sname......................: DongguanTaishenElectronicsCo.,Ltd. Address...............................................: 4thFloor,No.1,Alley5,DihaoStreet,Baiguodong,ZhangmutouTo wn,Dongguan,Guangdong,China Testspecification: Standard ................................................ :FCCCFRTitle47Part15SubpartC Testprocedure.....................................: / Non-standardtestmethod ................ :N/A ThisdevicedescribedabovehasbeentestedbyZHT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZHT,thisdocumentmay bealteredorrevisedbyZHT,personalonly,andshallbenotedintherevisionofthedocument. Productname ..................................... : WirelessChargingNightLightAlarmClock Trademark ........................................... : TS Model/Typereference.........................: TS-3001 TS-3002,TS-3003,TS-3004,TS-3005,TS-3006,TS-3007,TS-3008, TS-3009 Ratings..................................................: Input:9V3A(27W) USB-Aoutput:5V1A Wirelesschargingoutput:5Wor7.5Wor10Wor15WMax ProjectNo.:ZHT-230913002E Page 2 of 23 Testingprocedureandtestinglocation: TestingLaboratory..........................................:GuangdongZhonghanTestingTechnologyCo.,Ltd. Address............................................................:Room104,Building1,YibaolaiIndustrialPark,Qiaotou Community,FuhaiStreet,Bao'anDistrict,Shenzhen, Guangdong,China LeonLi Testedby(name+signature) ....................... : BaretWu Reviewer(name+signature) ....................... : LeviLeeApproved(name+signature).......................: ProjectNo.:ZHT-230913002E Page 3 of 23 TABLEOFCONTENTS 1.VERSION..................................................................................................................................4 2.TESTSUMMARY...................................................................................................................5 2.1TESTFACILITY...............................................................................................................................6 2.2MEASUREMENTUNCERTAINTY...............................................................................................6 3.GENERALINFORMATION..................................................................................................7 3.1GENERALDESCRIPTIONOFEUT............................................................................................7 3.2Testmode.........................................................................................................................................7 3.3BlockDiagramofEUTConfiguration...........................................................................................7 3.4TestConditions................................................................................................................................7 3.5DescriptionOfSupportUnits(ConductedMode).......................................................................8 3.6EQUIPMENTSLISTFORALLTESTITEMS.............................................................................9 4.CONDUCTEDEMISSIONTEST........................................................................................11 4.1CONDUCTEDEMISSIONMEASUREMENT...........................................................................11 4.1.1POWERLINECONDUCTEDEMISSIONLimits..................................................................11 4.1.2TESTPROCEDURE..................................................................................................................11 4.1.3DEVIATIONFROMTESTSTANDARD..................................................................................11 4.1.4TESTSETUP..............................................................................................................................12 4.1.5EUTOPERATINGCONDITIONS............................................................................................12 4.1.6TestResult..................................................................................................................................13 5.RADIATEDEMISSIONMEASUREMENT.......................................................................15 5.1RadiatedEmissionLimits.............................................................................................................15 5.2AnechoicChamberTestSetupDiagram...................................................................................16 5.3TestProcedure..............................................................................................................................16 5.4DEVIATIONFROMTESTSTANDARD.....................................................................................16 5.5TestResult......................................................................................................................................17 6.BANDWIDTHTEST.............................................................................................................20 7.ANTENNAREQUIREMENT..................................................


Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2BCU9-TS3001 EUTTESTPHOTOS ※※※※※ENDOFREPORT※※※※※

Contact Information

Applicant

qibin huang
[email protected]+8613662755156Fax: +8613662755156

Technical Contact

Dongguan Taishen Electronics Co., Ltd.
[email protected]

China

Test Firm

Guangdong Zhonghan Testing Technology Co., Ltd.Alex Wang
[email protected]86 18307618653

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.148 MHz-
Confidentiality
Long Term

Other Applications from Dongguan Taishen Electronics Co., Ltd.

2BCU9-TS-FT001

Ultrasonic level meter

Jan 22, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter