Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 04, 2024
Application Purpose
Original Equipment
Date of Application
Jan 04, 2024
Equipment Note
AirLight Pro
Frequency Range
2402.00000000 - 2480.00000000
Company
SZ ZUVI TECHNOLOGY CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

16) Do oot drop small pieces into the air ovtlet of the hair dryer, to avoid damaging the d的ce 17) Do oot place or store appliance where it can fall or be pulled into a tub or sink 18) Never block the air openings of the appliance or place it on a soft su什ace,such as a bed or couch, where the air openings may be blocked. Keep the air openings free of lint, hair, and the like 19) Never use wlh,le sleeping 20) Do oot place appliance on any su什acewhile it is operating 21) While using the appliance, keep your hair away from the air inlets 22) The appliance should never be left unattended wlhen plugged in If you are oo longer using the product, tum off虹unplugthe device 23) If the appliance falls into water, UNPLUG IT immediately DO NOT reach into the water 24) Do oot use an extension cord with this appliance 25) Do oot operate with a voltage converter 26) This hair dryer has an Appliance Leakage-Current-Interrupter to protect immersion (only a呾ab厄n the US). In the event of immerskm, the protective啦vicewill not allow the appliance to operate Periodically check the safety plug to verify that it is in proper working order Simply press the TEST button during operating The appliance should stop immediately To resume oper a ting, press the RESET button. If the TEST button does not work properly, contact Attersales Service 27) Do oot use wlhile bathing. 28) Do oot use attachments not recommended by the manufacturer 29) Do oot use outdoors or operate where aerosol (spra y ) products are being used 30) Do oot d'rect hot air toward eyes or other heat-sensitive areas 31)回MeansDOUBLE INSULATION SAVE THESE INSTRUCTIONS FCC Statement (US SKU only, no need for EU language) This equipment has been tested and found tD comply with the limits for a Class B digital device, pursuant tD part 15 of the FCC rules. These limits are designed to pr如dereasoniable protect,on against harmful interterence in a residential installation. This equipment generates, uses and can radiate radio frequency energy and,• not installed and used 1n acoordance with the 1nstruct1ons, may cause harmful 1nterlerence to radio communications. However, there is no guarantee that 1nterterence w,11 not occur in a particular installation. If this equipment does cause harmful 1nterlerence to radKJ or telev1s1on reception, which can be determined b f turning the equipment off and on, the user is encouraged to try to correct the interterence by one or more of the fo lowing measures -Reorient or relocate the rece1v1ng antenna. -I心reasethe separation between the equipment and r亟ver -Connect the equipment into an outlet on a circuit different from that to which the recer.,er�connected -Consult the dealer or an experienced rad1o{N technician f汀help To assure continued compliance, any changes or modificalioos not expressly approved by the party Respon叩efor compliance coo Id void the user's authority to operate this equipment (Example-use only sh哟ed intertace cables心nconnecting to computer or perip归aldevices) This equipment complies with Part 15 of the FCC Rules. Operation is subject to the followi心twoconditions (1)This deVJCe may not cause harmful 1nterterence, and (2)Th1s deVJCe must accept any 1nterterence rece殴d,includ1心1nterterencethat may cause und蕊iredoperation The device has been evaluated to meet general RF exposure requirement. The device can be used 1n portable exposure co心on w付<>Ut restriction Com p liance Information Supplier's Declaration of Conformity We, Zuvi Inc Address 12090,ange Street, Wilmington, New Castle, Delaware 19601 Internet contact in妇atKJnc www Zuv1L1fe com as the responsible party, declares that the below product has been test according to FCC rules and compliant with FCC rules andregula沁ns Product Name: 心Light Pro [TBD) Model Number: HS200 [TBD) P把ase be ad1nsed This device complies with Part 15 of the FCC Rules. Operation Is subject to the f必wing two conditions: (1) This dev心e may not cause harmful ,nte面ence, and(2) This device mustaccept 1nterlere飞e received, 1nclud1ng 1nterterence that may cause undesired operation 6©2023 L'Oreal Professionnel & Zuvi. All Rights Reserved Specifications Alrllghl Pro D1mens1ons Weight Rated Power Rated Voltage Ope「atingTemperature Bluetooth specificat,on Operating F「equency Transmitter Power (EIRP) Other RF specification Operating Frequency T『ansmitterPower (EIRP) 阶s content ,s subJect to change 265 x 98 x 84mm 615g 2100W (EU/UK/India)/ 1875W (US) 230V-, 50Hz(EU/\JK/lndia)/ 125V-, 60Hz(US) 5-40 ° C Bluetooth 5.3 2400-2483.SMHz <OdBm 119-135KHz <-20dBm Please find the latest version on ou「 official websrte Contact Us Official website www.zuvi.us ©2023 L'Oreal Professionnel & Zuvi. All Rights R蕊erved.9

Attestation Statements

SZ ZUVI TECHNOLOGY CO., LTD. Covered Equipment Certification Attestation Letter 12/14/2023 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2BCUI-HS200 SZ ZUVI TECHNOLOGY CO., LTD. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List , the applicant should include an explanation on why the equipment is not “covered” equipment. SZ ZUVI TECHNOLOGY CO., LTD. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signature: Name: Daniel Lou Phone: +86 755-86967225 Fax: / E-Mail: [email protected]

Cover Letter(s)

SZ ZUVI TECHNOLOGY CO., LTD. Date: 2023.12.14 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID:_ 2BCUI-HS200____ Product Name:__AirLight Pro ________ Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...) ☒ Schematics ☐ Parts List ☒ Block Diagram ☐ Tune-Up Info ☒ Operational Description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. In addition we hereby request the following exhibits contained in this application to be temporarily (short-term confidentiality) withheld from the public disclosure ☒ for an initial period of 180 days ☐ until: ☐ not applicable ☒ External Photos ☒ Test Setup Photos ☒ Internal Photos ☒ Users Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457(d), disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application. Signature: Name: Daniel Lou SZ ZUVI TECHNOLOGY CO., LTD. Phone: +86 755-86967225 Fax: / E-Mail: [email protected]

Cover Letter(s)

SZ ZUVI TECHNOLOGY CO., LTD. \\192.168.1.200\sz-ctc\09_工程部\RF实验室\2023年案件\11月\CTC231025-008 汝原 HS200 RED Uk FCC ID\1.资料\1.3 申请资料 \Letter\POA_Letter_140225.docx Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2023.12.14 SUBJECT: FCC Application for FCC ID: 2BCUI-HS200 To Whom It May Concern: We, the undersigned, hereby authorize _ Titto Zhao _ at _CTC Laboratories, Inc. on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by _ Titto Zhao _ on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Signature: Name: Daniel Lou Phone: +86 755-86967225 Fax: / E-Mail: [email protected]

Cover Letter(s)

SZ ZUVI TECHNOLOGY CO., LTD. Date: 20223.12.14 FCC ID: 2BCUI-HS200 Dear Sir/Madam, We, SZ ZUVI TECHNOLOGY CO., LTD. Hereby declares the Product name: AirLight Pro, Model no.: HS200, Have done SDOC certification. Sincerely, Signature: Name: Daniel Lou Phone: +86 755-86967225 Fax: / E-Mail: [email protected]

External Photos

External Photographs

ID Label/Location Info

Label Label Location 1.

Internal Photos

Page 1 of 7 Internal Photographs Page 2 of 7 Page 3 of 7 Page 4 of 7 RF ID Antenna Page 5 of 7 BLE Antenna Page 6 of 7 Page 7 of 7

Operational Description

SHENZHENB&TTECHNOLOGYCo.,Ltd ZHONGSHANB&TTECHNOLOGYCo.,Ltd -1- SPECIFICATIONFORAPPROVAL CUST OMER:Shenzhen Ai-Thinker Technology Co., Ltd CUS PART NO:PB-03 PART NAME:2.4G WLAN Antenna Edition:1.0 EditorYuan Nannan2021/12/13 VerifierGuan Ning2021/12/13 ApproverXu Fuqiang2021/12/13 SHENZHENB&TTECHNOLOGYCo.,Ltd ZHONGSHANB&TTECHNOLOGYCo.,Ltd Address: 3-4/F, Building A, Dongfang Industrial Park, Nanlang Town, Zhongshan City, Guangdong Province, China SHENZHENB&TTECHNOLOGYCo.,Ltd ZHONGSHANB&TTECHNOLOGYCo.,Ltd -2- Directory 1、Performance parameter .................................................................3 2、 VSWR ...................................................................................4 3 、 Passive test data ....................................................................4 4、 Radiation pattern .....................................................................5 SHENZH ENB&TTECHNOLOGYCo.,Ltd ZHONGSHANB&TTECHNOLOGYCo.,Ltd -3- Productspecification 1、 Performance parameter Name2.4G WLAN Antenna Model TypePCBPrint Antenna ELECTRICAL SPECTFICATIONS Frenquency Range2400-2500MHz Band Width100MHz Impedance50Ω VSWR< 2.0 Max Gain2.56dBi PolarizationVertical/Horizontal RadiationOmnidirectional Power50 W MECHANICAL SPECTFICATIONS ConnectorWelding type Working Temperature-40°C - + 85°C Limit Temperature-40°C - + 125°C SHENZHENB&TTECHNOLOGYCo.,Ltd ZHONGSHANB&TTECHNOLOGYCo.,Ltd -4- 2、VSWR 3、Passive test data: Frequency (MHz) 2400 2410 2420 2430 2440 2450 2460 2470 2480 2490 2500 Gain (dBi)1.952.101.962.112.042.282.302.392.352.562.36 Efficiency (%)54.5156.6955.3457.6256.2058.5658.0758.3256.8859.1556.37 SHENZHENB&TTECHNOLOGYCo.,Ltd ZHONGSHANB&TTECHNOLOGYCo.,Ltd -5- 4、Radiation pattern 2400MHz 2450MHz 2500MHz

RF Exposure Info

SZ ZUVI TECHNOLOGY CO., LTD. SAR COMPLIANCE REPORT Report Type: FCC SAR assessment report Model: HS200 REPORT NUMBER: 2311A1300SHA-004 ISSUE DATE: December 7, 2023 DOCUMENT CONTROL NUMBER: TTRFFCCSAR-01_V2 © 2022 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRFFCCSAR-01_V2© 2022 Intertek Page 2 of 7 Report no.: 2311A1300SHA-004 Applicant: SZ ZUVI TECHNOLOGY CO., LTD. Room 613, HKUST SZ IER Building, Yuexing 1st Road, Nanshan District, Shenzhen, Guangdong, China 518057 Manufacturer: SZ ZUVI TECHNOLOGY CO., LTD. Room 613, HKUST SZ IER Building, Yuexing 1st Road, Nanshan District, Shenzhen, Guangdong, China 518057 Factory SZ ZUVI FUYONG INTELLIGENT MANUFACTURING TECHNOLOGY CO. , LT D. Room 301, Building A, Kebixin Industrial Park, No. 47 Fuyuan 1st Road, Bao'an District, Shenzhen, Guangdong Province, China 518103 FCC ID: 2BCUI-HS200 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 447498 D04 Interim General RF Exposure Guidance v01 FCC Part2.1091, FCC Part2.1093 FCC Part1.1307(b) PREPARED BY: REVIEWED BY: Project Engineer Damon Ding Reviewer Eric Li Report No.: 2311A1300SHA-004 TEST REPORT TTRFFCCSAR-01_V2© 2022 Intertek Page 3 of 7 Revision History Report No. Version Description Issued Date 2311A1300SHA-004 Re v. 0 1 Initial issue of report December 7, 2023 Report No.: 2311A1300SHA-004 TEST REPORT TTRFFCCSAR-01_V2© 2022 Intertek Page 4 of 7 1 GENERAL INFORMATION 1.1 Description of Equipment Under Test (EUT) Product name: AirLight Pro Model: HS200 Description of EUT: EUT is an AirLight Pro . EUT supports RF ID and Bluetooth function. Rating: 120Vac/60Hz, 1800W Category of EUT: Class B EUT type: Table top Floor standing Software Version: / Hardware Version: / Sample received date: 2023.11.14 Date of test: 2023.11.14-2023.12.7 1.2 Technical Specification Frequency Band: 2402MHz to 2480MHz Support Standards: Bluetooth Low Energy Type of Modulation: GFSK Channel Number: 40 Date Rate 1Mbps Channel Separation: 2MHz Antenna Information: 2.39dBi, PCB antenna Frequency Range: 121kHz~128kHz Modulation: / Antenna: Coil antenna Report No.: 2311A1300SHA-004 TEST REPORT TTRFFCCSAR-01_V2© 2022 Intertek Page 5 of 7 1.3 Description of Test Facility Name: Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Telephone: 86 21 61278200 Te l e fa x : 86 21 54262353 The test facility is recognized, certified, or accredited by these organizations: CNAS Accreditation Lab Registration No. CNAS L0139 FCC Accredited Lab Designation Number: CN0175 IC Registration Lab CAB identifier.: CN0014 VCCI Registration Lab Member No.: 3598 (Registration No.: R-14243, G-10845, C-14723, T-12252) A2LA Accreditation Lab Certificate Number: 3309.02 Report No.: 2311A1300SHA-004 TEST REPORT TTRFFCCSAR-01_V2© 2022 Intertek Page 6 of 7 2 SAR Assessment Test result: Pass 2.1 SAR Test Exclusion Limit This method shall only be used at separation distances up to 40 cm and at frequencies from 0.3 GHz to 6 GHz (inclusive). P th is given by Formula below: f is in GHz, d is the separation distance (cm), and ERP 20cm is per Formula above. The example values shown in below are for illustration only. Frequency (MHz) Distance (mm) 5 10 15 20 25 30 35 40 45 50 300 39 65 88 110 129 148 166 184 201 217 450 22 44 67 89 112 135 158 180 203 226 835 9 25 44 66 90 116 145 175 207 240 1900 3 12 26 44 66 92 122 157 195 236 2450 3 10 22 38 59 83 111 143 179 219 3600 2 8 18 32 49 71 96 125 158 195 5800 1 6 14 25 40 58 80 106 136 169 2.2 Assessment Results As we can see from the BLE test report 2311A1300SHA-001: The highest EIRP adjusted with tune-up tolerance is: 3.81dBm=2.404mW 2.404mW < 3mW (Test Exclusion Thresholds of 2450MHz at 5mm). Report No.: 2311A1300SHA-004 TEST REPORT TTRFFCCSAR-01_V2© 2022 Intertek Page 7 of 7 As we can see from the RF ID test report 2311A1300SHA-002: The highest test data with is: 85.46dBuV/m = 0.0187 V/m < 614 V/m BLE and RF ID can transmit simultaneously 2.404mW / 3mW + 0.0187 V/m / 614 V/m = 0.801 < 1 Therefore, the SAR requirement is deemed to be satisfied without test. ******************************************* END ************************************

Test Report

SZ ZUVI TECHNOLOGY CO., LTD. RF TEST REPORT Report Type: FCC Part 15.247 & ISED RSS-247 RF report Model: HS200 REPORT NUMBER: 2311A1300SHA-001 ISSUE DATE: December 7, 2023 DOCUMENT CONTROL NUMBER: TTRF15.247-02_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15.247-02_V1 © 2018 Intertek Page 2 of 56 Report no.: 2311A1300SHA-001 Applicant: SZ ZUVI TECHNOLOGY CO., LTD. Room 613, HKUST SZ IER Building, Yuexing 1st Road, Nanshan District, Shenzhen, Guangdong, China 518057 Manufacturer: SZ ZUVI TECHNOLOGY CO., LTD. Room 613, HKUST SZ IER Building, Yuexing 1st Road, Nanshan District, Shenzhen, Guangdong, China 518057 Factory SZ ZUVI FUYONG INTELLIGENT MANUFACTURING TECHNOLOGY CO., LTD. Room 301, Building A, Kebixin Industrial Park, No. 47 Fuyuan 1st Road, Bao'an District, Shenzhen, Guangdong Province, China 518103 FCC ID: 2BCUI-HS200 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 47CFR Part 15 (2017): Radio Frequency Devices (Subpart C) ANSI C63.10 (2013): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices PREPARED BY: REVIEWED BY: Project Engineer Damon Ding Reviewer Eric Li Report No.: 2311A1300SHA-001 TEST REPORT TTRF15.247-02_V1 © 2018 Intertek Page 3 of 56 Content REVISION HISTORY................................................................................................................................................ 5 MEASUREMENT RESULT SUMMARY ..................................................................................................................... 6 1 GENERAL INFORMATION ............................................................................................................................. 7 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ................................................................................................ 7 1.2 TECHNICAL SPECIFICATION ................................................................................................................................ 7 1.3 DESCRIPTION OF TEST FACILITY .......................................................................................................................... 8 2 TEST SPECIFICATIONS ................................................................................................................................. 10 2.1 STANDARDS OR SPECIFICATION ........................................................................................................................ 10 2.2 MODE OF OPERATION DURING THE TEST ............................................................................................................ 10 2.3 TEST SOFTWARE LIST ..................................................................................................................................... 11 2.4 TEST PERIPHERALS LIST................................................................................................................................... 11 2.5 TEST ENVIRONMENT CONDITION: ..................................................................................................................... 11 2.6 INSTRUMENT LIST ......................................................................................................................................... 12 2.7 MEASUREMENT UNCERTAINTY ......................................................................................................................... 14 3 MINIMUM 6DB BANDWIDTH ..................................................................................................................... 15 3.1 LIMIT ......................................................................................................................................................... 15 3.2 MEASUREMENT PROCEDURE .......................................................................................................................... 15 3.3 TEST CONFIGURATION ................................................................................................................................... 15 3.4 TEST RESULTS OF MINIMUM 6DB BANDWIDTH ................................................................................................... 15 4 MAXIMUM CONDUCTED OUTPUT POWER AND E.I.R.P. ............................................................................. 16 4.1 LIMIT ......................................................................................................................................................... 16 4.2 MEASUREMENT PROCEDURE .......................................................................................................................... 16 4.3 TEST CONFIGURATION ................................................................................................................................... 17 4.4 TEST RESULTS OF MAXIMUM CONDUCTED OUTPUT POWER ....................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Setup

Contact Information

Applicant

Daniel Lou(Compliance Manager)
[email protected]+86 755-86967225Fax: N/A

Test Firm

Intertek Testing Services (Shanghai FTZ) Co., Ltd.Leah Xu
[email protected]86-21-61278200

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.40 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.