Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 29, 2025
Application Purpose
Original Equipment
Equipment Note
IP Phone
Frequency Range
2402.00000000 - 2480.00000000
Company
Fanvil Link Technology Co.,LTD
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Fanvil Link Technology Co.,LTD Address: 13th Floor, Building 2, Runzhi R&D Center, Xin'an Street, Bao'an District, Shenzhen, Guangdong, China Tel: +86 15089240223 Email: [email protected] Attestation Letter FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: 2025-07-02 To Whom It May Concern, Our product IP Phone, model: J600W, X303W, X301W, J303W, FCC ID: 2BCUQ-J600W, For use in America, this product only supports BDR (GFSK), EDR (π/4-DQPSK, 8DPSK); BLE 1M/2M; 2.4G Wi-Fi (2412-2462MHz; 802.11 b/g/n20/n40/ax20/ax40 modes), 5G Wi-Fi (5150- 5250MHz, 5725-5850MHz; 802.11a/n20/n40/ac20/ac40/ac80/ax20/ax40/ax80 modes). The other functions, bands and modes were disabled to use by manufacturer in the software, and for 802.11ax mode, it only supports full RU configuration not partial RU, the partial RU was also disabled by software, the end user has no capability to activate it. Sincerely, Signature: Mengjiao Hu Certified Engineer

Attestation Statements

CFR 47 §2.911(d)(5)(i) Attestation Letter Fanvil Link Technology Co.,LTD Address: 13th Floor, Building 2, Runzhi R&D Center, Xin'an Street, Bao'an District, Shenzhen, Guangdong, China Tel: +86 15089240223 Email: [email protected] Attestation Letter Date: 2025-07-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID: 2BCUQ-J600W Fanvil Link Technology Co.,LTD certifies that the equipment for which authorization is sought, is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Signature Mengjiao Hu Certified Engineer

Attestation Statements

CFR 47 §2.911 (d)(5)(ii) Attestation Letter Fanvil Link Technology Co.,LTD Address: 13th Floor, Building 2, Runzhi R&D Center, Xin'an Street, Bao'an District, Shenzhen, Guangdong, China Tel: +86 15089240223 Email: [email protected] Attestation Letter Date: 2025-07-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID: 2BCUQ-J600W Fanvil Link Technology Co.,LTD certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature Mengjiao Hu Certified Engineer

Attestation Statements

U.S. AGENT LETTER OF ATTESTATION Date: 2025-07-02 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2BCUQ-J600W Fanvil Link Technology Co.,LTD certifies that, as of the date of the filing of the application, EMCTEK is our designated U.S. agent for service of process for the above referenced FCC ID. Fanvil Link Technology Co.,LTD accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. EMCTEK accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: EMCTEK Address:11788 Big Canyon Lane, San Diego, CA 92131 USA FRN: 0037012671 Tel.: + (858) 401-9073 Email: [email protected] Signed by (printed name): Fang Liu Signature: Applicant: Fanvil Link Technology Co.,LTD Address: 13th Floor, Building 2, Runzhi R&D Center, Xin'an Street, Bao'an District, Shenzhen, Guangdong, China FRN: 0034227223 Tel: +86 15089240223 Email: [email protected] Signed by (printed name): Mengjiao Hu Signature:

Cover Letter(s)

Fanvil Link Technology Co.,LTD Address: 13th Floor, Building 2, Runzhi R&D Center, Xin'an Street, Bao'an District, Shenzhen, Guangdong, China Tel: +86 15089240223 Email: [email protected] QA-FR-170-B 7/29/2014 FCC Authorization Date: 2025-07-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Fanvil Link Technology Co.,LTD, the undersigned, hereby authorizes Bay Area Compliance Laboratories Corp. (Shenzhen) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. (Shenzhen) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely, Signatures Mengjiao Hu Certified Engineer

Cover Letter(s)

Fanvil Link Technology Co.,LTD Address: 13th Floor, Building 2, Runzhi R&D Center, Xin'an Street, Bao'an District, Shenzhen, Guangdong, China Tel: +86 15089240223 Email: [email protected] FCC Confidential Authorization Date: 2025-07-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2BCUQ-J600W In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Fanvil Link Technology Co.,LTD hereby requests long-term confidential treatment of information accompanying this application as outlined below:  Block Diagram  Schematics  Operation Description  Software Security Description As well as short-term confidential treatment of information accompanying this application for a period of 180 days after grant is issued as outlined below:  Internal Photos  User’s Manual  External Photos  Test Set-up Photos The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Mengjiao Hu Certified Engineer

Cover Letter(s)

Fanvil Link Technology Co.,LTD Address: 13th Floor, Building 2, Runzhi R&D Center, Xin'an Street, Bao'an District, Shenzhen, Guangdong, China Tel: +86 15089240223 Email: [email protected] Product Similarity Declaration Date: 2025-07-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir/Madam, We, Fanvil Link Technology Co.,LTD hereby declare that we have a product named as IP Phone, model: J600W; FCC ID: 2BCUQ-J600W, was tested by Bay Area Compliance Laboratories Corp. (Shenzhen), Meanwhile, for our marketing purpose, we would like to list a series model (X303W, X301W, J303W) on reports and certificate, all the models are identical in electrically, the difference is the model name , shell button, antenna and LED indicator are differences. There is no other difference. We confirm that all information above is true, and we’ll be responsible for all the consequences. Please contact me if you have any question. Sincerely, Signature, Mengjiao Hu Certified Engineer

ID Label/Location Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2501S52427E-RF EXHIBIT A - FCC ID LABEL AND LOCATION Model: J600W FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925) Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2501S52427E-RF Model: X303W FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925) Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2501S52427E-RF Model: X301W FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925) Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2501S52427E-RF Model: J303W FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C TR-EM-RF001 Page 135 of 137 Version 4.1 RF EXPOSURE EVALUATION MPE-Based Exemption Applicable Standard According to subpart 2.1091 systems operating under the provisions of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in excess of the communication guidelines. According to KDB 447498 D04 v01 Interim General RF Exposure Guidance MPE-Based Exemption: General frequency and separation-distance dependent MPE-based effective radiated power(ERP) thresholds are in Table B.1 [Table 1 of § 1.1307(b)(3)(i)(C)] to support an exemption from further evaluation from 300 kHz through 100 GHz. R is the minimum separation distance in meters f = frequency in MHz Result Antenna Gain # ERP Mode Frequency (MHz) Tune up conducted power # (dBm) (dBi)(dBd)(dBm) (mW) Evaluation Distance (m) ERP Limit (mW) BT2402-24802.55.9 3.75 6.25 4.22 0.2768 BLE2402-24802.55.9 3.75 6.25 4.22 0.2768 2.4G Wi-Fi2412-246221.0 5.9 3.75 24.75 298.54 0.2768 5.2G Wi-Fi5180-524018.0 6.1 3.95 21.95 156.68 0.2768 5.8G Wi-Fi5745-582518.0 5.6 3.45 21.45 139.64 0.2768 Note: 1. The tune up conducted power and antenna gain was declared by the applicant. 2. 0dBd=2.15dBi 3. The BT, 2.4G and 5G Wi-Fi cannot transmit at same time. To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm from nearby persons. Result: Compliant

Test Report

Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018Fax: +86-755-33320008www.baclcorp.com.cn TR-EM-RF001 Page 1 of 137 Version 4.1 TEST REPORT Applicant Name:Fanvil Link Technology Co.,LTD Address:13th Floor, Building 2, Runzhi R&D Center, Xin'an Street, Bao'an District, Shenzhen, Guangdong, China Report Number:2501S52427E-RF-00C FCC ID:2BCUQ-J600W Test Standard (s) FCC PART 15.247 Sample Description Product Type:IP Phone Model No.:J600W Multiple Model(s) No.:X303W, X301W, J303W Trade Mark: Date Received:2025-04-09 Issue Date:2025-09-17 Test Result:Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By:Approved By: Bruce LinNancy Wang RF EngineerRF Supervisor Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C TR-EM-RF001 Page 2 of 137 Version 4.1 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ..........................................................................................................................3 GENERAL INFORMATION ........................................................................................................................................4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)......................................................................................4 OBJECTIVE ....................................................................................................................................................................4 TEST METHODOLOGY....................................................................................................................................................4 MEASUREMENT UNCERTAINTY .....................................................................................................................................5 TEST FACILITY ..............................................................................................................................................................5 SYSTEM TEST CONFIGURATION ...........................................................................................................................6 SUMMARY OF TEST RESULTS ..............................................................................................................................10 TEST EQUIPMENT LIST ..........................................................................................................................................11 REQUIREMENTS AND TEST PROCEDURES ......................................................................................................13 AC LINE CONDUCTED EMISSIONS...............................................................................................................................13 RADIATED EMISSIONS .................................................................................................................................................15 20 DB EMISSION BANDWIDTH .....................................................................................................................................18 CHANNEL SEPARATION TEST ......................................................................................................................................20 QUANTITY OF HOPPING CHANNEL TEST .....................................................................................................................21 TIME OF OCCUPANCY (DWELL TIME) .........................................................................................................................22 PEAK OUTPUT POWER MEASUREMENT .......................................................................................................................23 BAND EDGES ...............................................................................................................................................................24 CONDUCTED SPURIOUS EMISSION...............................................................................................................................25 ANTENNA REQUIREMENT .....................................................................................................................................26 TEST DATA AND RESULTS .....................................................................................................................................27 AC LINE CONDUCTED EMISSIONS...............................................................................................................................27 RADIATED EMISSIONS .................................................................................................................................................40 RF CONDUCTED DATA ..............................................................................................................................................134 RF EXPOSURE EVALUATION ..............................................................................................................................135 EUT PHOTOGRAPHS .........…

Text truncated - open the document above for the full version.

Test Report

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 1 of 37 Appendix C RF Test: General Information Project No.:2501S52427E-RF EUT Number:314C-1 Operating Mode:Transmitting Test Conditions:Temperature: 25-28°C Relative Humidity:51-27% ATM Pressure:100-101kPa Test Engineer:Lee Li&Rainbow Zhu Test Date:2025-04-19 ~ 2025-09-10 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 2 of 37 20dB Emission Bandwidth Test Result Test ModeAntennaFrequency[MHz] 20dB EBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 24020.9482401.5322402.480------ 24410.9482440.5322441.480------ DH1Ant1 24800.9482479.5322480.480------ 24021.3112401.3372402.648------ 24411.3082440.3372441.645------ 2DH1Ant1 24801.3082479.3342480.642------ 24021.2812401.3612402.642------ 24411.2782440.3612441.639------ 3DH1Ant1 24801.2782479.3612480.639------ Test Graphs DH1_Ant1_2402 DH1_Ant1_2441 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 3 of 37 DH1_Ant1_2480 2DH1_Ant1_2402 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 4 of 37 2DH1_Ant1_2441 2DH1_Ant1_2480 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 5 of 37 3DH1_Ant1_2402 3DH1_Ant1_2441 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 6 of 37 3DH1_Ant1_2480 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 7 of 37 Occupied Channel Bandwidth Test Result Test ModeAntennaFrequency[MHz] OCB [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 24020.8482401.57442402.4226------ 24410.8482440.57442441.4226------ DH1Ant1 24800.8482479.57442480.4226------ 24021.1872401.40362402.5904------ 24411.1812440.40362441.5844------ 2DH1Ant1 24801.1782479.40062480.5784------ 24021.1692401.42462402.5934------ 24411.1692440.42462441.5934------ 3DH1Ant1 24801.1662479.42462480.5904------ Test Graphs DH1_Ant1_2402 DH1_Ant1_2441 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 8 of 37 DH1_Ant1_2480 2DH1_Ant1_2402 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 9 of 37 2DH1_Ant1_2441 2DH1_Ant1_2480 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 10 of 37 3DH1_Ant1_2402 3DH1_Ant1_2441 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 11 of 37 3DH1_Ant1_2480 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 12 of 37 Maximum conducted output power Test Result Peak Test ModeAntennaFrequency[MHz] Conducted Peak Power [dBm] Conducted Limit[dBm] Verdict 24022.43≤20.97PASS 24410.66≤20.97PASS DH1Ant1 2480-0.01≤20.97PASS 24021.88≤20.97PASS 24410.11≤20.97PASS 2DH1Ant1 2480-0.56≤20.97PASS 24022.29≤20.97PASS 24410.57≤20.97PASS 3DH1Ant1 2480-0.13≤20.97PASS Test Graphs DH1_Ant1_2402 DH1_Ant1_2441 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 13 of 37 DH1_Ant1_2480 2DH1_Ant1_2402 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 14 of 37 2DH1_Ant1_2441 2DH1_Ant1_2480 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 15 of 37 3DH1_Ant1_2402 3DH1_Ant1_2441 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 16 of 37 3DH1_Ant1_2480 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 17 of 37 Carrier frequency separation Test Result Test ModeAntennaFrequency[MHz]Result[MHz]Limit[MHz]Verdict DH1Ant1Hop1.003≥0.874PASS Note: Only the BDR (GFSK) mode result is reported since EDR (π /4-DQPSK) and EDR (8DPSK) modes have the exact same channel plan, and the limit is the maximum 20dB bandwidth *2/3 Test Graphs DH1_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 18 of 37 Time of occupancy Test Result Test ModeAntennaFrequency[MHz] Burst Width [ms] Total Hops [Num] Result[s]Limit[s]Verdict DH1Ant1Hop0.3643300.12≤0.4PASS DH3Ant1Hop1.6131600.258≤0.4PASS DH5Ant1Hop2.8531100.314≤0.4PASS 2DH1Ant1Hop0.3743300.123≤0.4PASS 2DH3Ant1Hop1.6181400.227≤0.4PASS 2DH5Ant1Hop2.8591100.314≤0.4PASS 3DH1Ant1Hop0.3743300.123≤0.4PASS 3DH3Ant1Hop1.6161700.275≤0.4PASS 3DH5Ant1Hop2.8601100.315≤0.4PASS Note 1: A period time=0.4*79=31.6(S), Result=Burst Width*Total hops Note 2: Total hops=Hopping Number in 3.16s*10 Note 3: Hopping Number in 3.16s=Total of highest signals in 3.16s(Second high signals were other channel) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 19 of 37 Test Graphs DH1_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 20 of 37 DH3_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 21 of 37 DH5_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 22 of 37 2DH1_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 23 of 37 2DH3_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 24 of 37 2DH5_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 25 of 37 3DH1_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 26 of 37 3DH3_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 27 of 37 3DH5_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 28 of 37 Number of hopping channels Test Result Test ModeAntennaFrequency[MHz]Result[Num]Limit[Num]Verdict DH1Ant1Hop79≥15PASS 2DH1Ant1Hop79≥15PASS 3DH1Ant1Hop79≥15PASS Test Graphs DH1_Ant1_Hop 2DH1_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2501S52427E-RF-00C Page 29 of 37 3DH1_Ant1_Hop Bay Area Compliance Laboratories Corp. …

Text truncated - open the document above for the full version.

Test Report

东莞市一佳电子通讯科技有限公司 Dongguan YiJia Electronics Communication Technology Co.,Ltd. 规格承认书 SPECIFICATION FOR APPROVAL 日期 Date 2022/12/29 编号 File No 22122902 版本 Revision 1.0 客户 CUSTOMER: 方位 客户料号 CUSTOMER NO: J303W 品名 WIFI双频Antenna L 90mm 品名 PART NAME: WIFI双频Antenna L=90mm 供方料号 SUPPLIER NO: YJL01.106.041.302A 送样日期 Date: 送样数量Q“TY: 客户确认CUSTOMER APPROVED BY APPROVALCHIEFSUPERVISOR 供方确认SUPPLIER SIGNATURE APPROVALCHECKDESIGN add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 APPROVALCHECKDESIGN ChenGuoqiangXieLiChenXingyi YJ-RD-F04-A 承认书项目表 NO . 内容 (Contents) 页数 (Number of Page) 页码 (Page Code) 1 承认书封面(Spec Cover) 11 承认书封面(p) 2 承认书项目表(Spec Item ) 12 3 工程成品图(Drawing) 13 4 天线规格(Antenna Specification) 14 5 S参数测试(S Parameter ) 15 6 无源测试(Passive Test ) 36 ~ 8 7 方向图(Radiation Pattern ) 29 ~ 10 8 有源测试(Active Test ) 111 9 天线装配图(At P fil) 212 139 天线装配图(Antenna Profile) 212 ~ 13 10 材质证明(Material Certificate ) 2514 ~ 38 11 RoHS报告(RoHS Test Report ) **** add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 12N/AN/AN/A 13--- 天线规格 Antenna Specification Electrical Properties Frequency 2.4-2.5GHz 5.15-5.85GHz Impedance50 Ohm Nominal V.S.W.R 2.5 [email protected] 2.0 [email protected] 44dBi@24-25GHz Gain 4.4 [email protected] 5.6 [email protected] RadiationOmni-directional PolarizationLinear Physical Properties ConnectorNone Cable TypeO.D.1.13mm Cable Length90mm Cable ColorBlack add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Operating Temp.-40 ~ +85 ̊C Storage Temp / Humidity 25±5 ̊C / <70% Antenna Performance Test Agilent Antenna Performance Te s t Agilent E5071B SS Parameter Test // WIFI Antenna add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Antenna Passive TestAntenna Passive Te s t ZZ Y X X Z Y add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Passive Test For WiFi Antenna(2.4G) FreqEffiEffiGain (MHz)(%)(dB)(dBi) 2400 49.7 -3.0 4.1 2410 50.5 -3.0 3.9 2420 48.9 -3.1 3.7 2430 48.8 -3.1 3.9 2440 48.9 -3.1 4.1 2450 50.7 -3.0 4.4 2460 47.8 -3.2 3.7 2470 50.0 -3.0 4.0 2480 48.5 -3.1 3.9 add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 2490 49.2 -3.1 4.2 2500 46.2 -3.4 3.8 Passive Test For WiFi Antenna(5.8G) FreqEffiEffiGain (MHz)(%)(dB)(dBi) 515063.7 -2.0 4.1 520062.4 -2.1 4.2 525060 02241525060.0 -2.2 4.1 530059.4 -2.3 4.1 535057.7 -2.4 3.9 540059.4 -2.3 4.6 545058.3 -2.3 4.6 550053.2 -2.7 4.6 555057.4 -2.4 5.3 560061.7 -2.1 5.2 565055.7 -2.5 4.8 570055.9 -2.5 5.1 575066 11856 add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 575066.1 -1.8 5.6 580065.8 -1.8 5.5 585059.7 -2.2 4.8 Radiation Pattern For WIFI Antenna(2450MHz) add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For WIFI Antenna(5500MHz) add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Active Test For WIFI Antenna Band Channel Data Rate TRP Data Rate TIS WIFI 2.4G 802.11b 1 11Mbps 14.2 11Mbps -82.5 6 14.2 -81.3 11 13.8 -81.7 WIFI 2.4G 802.11g 1 54Mbps 12.8 54Mbps -69.7 6 12.4 -68.6 11 12.2 -69.1 WIFI 2.4G 80211n 1 MCS7 11.2 MCS7 -65.4 6 10.6 -65.6 802.11n 11 10.5 -65.0 149 16.2 -67.2 add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 WIFI 5G 802.11a 54Mbps54Mbps157 16.0 -68.0 165 15.7 -67.3 Device WIFI Antenna add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 WIFI Antenna add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 , 安 全 資 料 表 版權2021-01-10 PSM-800FSDM-A/SMH-800 1 ,一、化學品與廠商資料 化學品名稱:液態熱固軟板油墨 PSM-800FSDM-A/SMH-800 其他名稱: 建議用途及限制使用:柔性电路板(PI/Cu) ,手機天線板 製造者、輸入者或供應者名稱、地址及電話:製造者:優立實業股份有限公司 住址:桃園市觀音區經建四路22號 電話:886-3-4836651 緊急聯絡電話/傳真電話:電話:886-3-4836651、傳真:886-3-4837487 二、危害辨識資料 化學品危害分類: 健康及環境危害:急毒性物質(吞食)第 4 級、腐蝕/刺激皮膚物質第2級、嚴重損傷/刺激眼睛物質第2A級、皮膚 過敏物質第1級、致癌物質第2級、水環境之危害物質(急毒性)第2級。 標示內容: 象 徵 符 號: 警 示 語:警告 危害警告訊息: 吞食有害 造成皮膚刺激 造成嚴重眼睛刺激 可能造成皮膚過敏 懷疑致癌 對水生生物有毒 危害防範措施: 置容器於通風良好的地方 遠離高温 使用時勿吃、喝 衣服一經污染,立即脫掉 戴眼罩/護面罩 若與眼睛接觸,立刻以大量的水洗滌後洽詢醫療 戴上合適的手套 勿吸入氣體/煙氣/蒸氣/霧氣 使用前取得說明 置放於上鎖處 在瞭解所有安全防範措施之前切勿處置 避免釋放至環境中 其他危害:- 三、成份辨識資料 混合物: 中英文名稱:液態熱固軟板油墨PSM-800FSDM-A/SMH-800 化學性質: 危害成分之中英文名稱 化學文摘社登記號碼(CAS No.) 濃度或濃度範圍(成分百分比) 環氧丙烯酸酯寡聚物Epoxy acrylate oligmer 28064-14-4 50 % 二氧化矽Fused silica 7631-86-9 13 % 芳香族溶劑Aromatic solvent 64742-94-5 4 % , 安 全 資 料 表 版權2021-01-10 PSM-800FSDM-A/SMH-800 2 二丙二醇甲基醚Methyl dipropylene glycol 34590-94-8 4% 碳黑Carbon black 1333-86-4 3.5 % 硫酸鋇BaSO4 13462-86-7 24 % 光敏劑及其它Photoinitiator and the others 5495-84-1 1.5 % 四、急救措施 不同暴露途徑之急救方法: 吸 入:1.施救前先做好自身的防護措施。 2.移走污染源或將患者移至新鮮空氣處。 3.若有病人呼吸停止,立即由受過訓的人施以人工呼吸,若心跳停止,施行心肺復甦術,當患者吸入和吞下 毒性物質時,別直接使用口對口人工呼吸,應使用單向給氣式之口袋型面罩和其他醫療器材來執行人工呼 吸。 4.保持患者安靜及維持正常體溫。6.儘速就醫治療。 皮膚接觸:儘快以緩和流動的水沖洗受污染區域至少20 分鐘,沖水前,脫掉污染的衣物、鞋子、皮飾品。 眼睛接觸:立即將眼皮撐開用緩和流動的水沖洗受污眼睛至少20 分鐘,並立即就醫。 食 入:1.若患者即將喪失意識,或已喪失意識或痙攣,不可餵食任何東西。 2.不可催吐,並給予240-300ml 的水。 3.如果自發性嘔吐,讓其漱口,並反覆給水。 最重要症狀及危害效應:- 對急救人員之防護:- 對醫師之提示:- 五、滅火措施 適用滅火劑:化學乾粉、酒精泡沫、二氧化碳、噴水,大火:噴水、水霧、泡沫水霧。 滅火時可能遭遇之特殊危害: 1.其蒸氣及熱分解物易燃及有毒。 2.其蒸氣較空氣重,能傳播至遠處之火源處,發生回火。 3.蒸氣與大氣結合可能會發生爆炸。 4.當此物質在室內、室外或下水道有蒸氣爆炸危險。 特殊滅火程序: 1.在安全距離的地方滅火,保持在上風位置。 2.可用水冷卻容器,分散蒸氣沖洗外洩並稀釋外洩物,保護搶救人員。 3.用水噴灑露在火焰中的容器四週,使容器冷卻,直到火勢被撲滅為止。離開容器的本端以維安全。 4.撲滅或移開所有引燃源。 消防人員之特殊防護裝備:消防人員必須配戴空氣呼吸器、消防衣及防護手套。 六、洩漏處理方法 個人應注意事項: 1.限制人員進入,直至外溢區完全清理乾淨為止。 2.由受過訓之人員負責清理之工作。 3.穿戴適當的個人防護裝備。 環境注意事項: 1.移去引火源。 2.保持洩漏區通風。 3.處在上風處,避免進入低處。 4.在不危及人員安全情況下,搬移或隔離易燃和可燃物。 5.隔離污染源至少100 至200 公尺。 清理方法: 1.不可碰觸外洩物。 , 安 全 資 料 表 版權2021-01-10 PSM-800FSDM-A/SMH-800 3 2.避免外洩物進入下水道或密閉的空間內。 3.在安全許可的情形下,設法阻止或減少溢漏。 4.用不會和外洩物反應的泥土、沙或相似穩定且不可燃的物質圍堵外洩物。 5.少量溢漏時,用不會和外洩物反應之吸收劑吸收。已污染的吸收劑和外洩物具有同樣的 6.危害性,須置於加蓋並標示的適當容器裡。用水沖洗溢漏區域。 7.大量溢漏時:連絡消防、緊急處理單位及供應商以尋求協助。 七、安全處置與儲存方法 處置: 1.貯存於陰涼乾燥涼好通風的地方,並避免陽光直射、熱及引火源。 2.遠離不容物如強氧化物、強酸、水。 3.使用接地、與無火花之電器儀器、通風系統。 4.小量時貯存於冰箱,並使用防爆炸冰箱。 5.設外洩警報系統。 6.須貯存區與工作區隔離,並限制人員出入貯存區,並貼示警告標語。 7.避免碰撞,並就近設滅火系統。 8.不可單獨工作,另一人需隨時待命救援。 9.在工作區使用許可裝運燃燒性液體的容器,並且所有桶槽、轉裝容器都要接地,且須接觸到裸金屬。 10.使用最小可能的量,並在指定區內,使用適合的通風系統。 11.標示容器,當不使用時要緊蓋。 儲存: 1.貯存於陰涼乾燥涼好通風的地方,並避免陽光直射、熱及引火源。 2.小量時貯存於冰箱,並使用防爆炸冰箱。 3.須貯存區與工作區隔離,並限制人員出入貯存區,並貼示警告標語。 4.標示容器,當不使用時要緊蓋。 八、暴露預防措施 工程控制: 1.單獨使用步產生火花、接地的通風系統。 2.排氣口直接通到室外、並採取保護的重要措施。 3.大量使用此物質時,可能需要局部排氣裝置和製程密閉。 4.供給充分新鮮空氣以補充排氣系統抽出的空氣。 控制參數:- 八小時日時量平均容許濃度/短時間時量平均容許濃度/最…

Text truncated - open the document above for the full version.

Test Report

规格承认书 SPECIFICATION FOR APPROVAL 日期 Date 2025/03/28 编号 File No 25032803 版本 Revision 1.0 客户 CUSTOMER: 客户料号 CUSTOMER NO: J600 品名 PARTNAME: WIFI Antenna L=55mm 供方料号 SUPPLIERNO: YJL01.106.078.301A 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 SUPPLIERNO: YJL01.106.078.301A 送样日期Date: 送样数量Q'TY: 客户确认CUSTOMER APPROVED BY APPROVALCHIEFSUPERVISOR 供方确认SUPPLIER SIGNATURE APPROVALCHECKDESIGN ChenGuoqiangXieLiChenXingyi YJ-RD-F04-A Fanvil Add: Yuanfu Industrial Zone, No. 59, Muyu Road, Shatou Community, Chang'an Town, Dongguan City 承认书项目表 NO . 内容 (Contents) 页数 (Number of Page) 页码 (Page Code) 1 承认书封面(Spec Cover) 11 2 承认书项目表(Spec Item ) 12 3 工程成品图(Drawing) 13 4 天线规格(Antenna Specification) 14 5 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 5 6 无源测试(Passive Test ) 35 ~ 7 7 方向图( Radiation Pattern ) 78 ~ 14 8 有源测试(Active Test ) 115 9 10 11 12N/AN/AN/A 13--- Add: Yuanfu Industrial Zone, No. 59, Muyu Road, Shatou Community, Chang'an Town, Dongguan City N/AN/AN/A N/AN/AN/A N/AN/AN/A N/AN/AN/A 天线规格 Antenna Specification Electrical Properties Frequency 2.4-2.5GHz 5.15-5.85GHz Impedance50 Ohm Nominal V.S.W.R 2.0 [email protected] 2.5 [email protected] Gain 5.9 [email protected] 6.1 [email protected] RadiationOmni-directional 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 RadiationOmni-directional PolarizationLinear Physical Properties ConnectorNone Cable TypeO.D.1.13mm Cable Length55mm Cable ColorBlack Operating Temp.-40 ~ +85 ̊C Storage Temp / Humidity 25±5 ̊C / <70% Add: Yuanfu Industrial Zone, No. 59, Muyu Road, Shatou Community, Chang'an Town, Dongguan City Agilent E5071C S Antenna Performance Test 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 S Parameter Test // WiFi Antenna Add: Yuanfu Industrial Zone, No. 59, Muyu Road, Shatou Community, Chang'an Town, Dongguan City Passive Test For WiFi Antenna(2.4G) Freq (MHz) Effi (%) Effi (dB) Gain (dBi) 2400 58.2 -2.4 4.7 2410 59.3 -2.3 4.8 2420 58.9 -2.3 4.8 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 2430 59.5 -2.3 4.9 2440 59.8 -2.2 4.9 2450 60.2 -2.2 5.4 2460 60.7 -2.2 5.2 2470 61.4 -2.1 5.8 2480 61.2 …

Text truncated - open the document above for the full version.

Contact Information

Applicant

mengjiao Hu
[email protected]Fax: N/A

Test Firm

Bay Area Compliance Laboratories Corp (Shenzhen)Nana Liu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.70 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Fanvil Link Technology Co.,LTD

USB Workstation - FCC ID 2BCUQ-DB36 - Fanvil Link Technology Co.,LTD
2BCUQ-DB36

USB Workstation

Aug 12, 2026

Equipment Class

DTS - Digital Transmission System
2BCUQ-W626W

Wi-Fi Phone

Aug 06, 2026

Equipment Class

DTS - Digital Transmission System
Bluetooth Key - FCC ID 2BCUQ-BK01 - Fanvil Link Technology Co.,LTD
2BCUQ-BK01

Bluetooth Key

Jun 22, 2026

Equipment Class

DTS - Digital Transmission System
Bluetooth Key - FCC ID 2BCUQ-BK05 - Fanvil Link Technology Co.,LTD
2BCUQ-BK05

Bluetooth Key

Jun 17, 2026

Equipment Class

DTS - Digital Transmission System
Elevator Card Reader - FCC ID 2BCUQ-WR02 - Fanvil Link Technology Co.,LTD
2BCUQ-WR02

Elevator Card Reader

May 12, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter