Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
www.bovetech.com Installation & User Guide BECO Y Ultrasonic Water Meter Read this Guide before installing the meter Copyright© 2023 Bove Intelligent Technology Co., Ltd Thank you for choosing our products ⚫ The contents of this manual are subject to change without prior notice as a result of continuing improvements to the meter’s performance and functions. ⚫ Every effort has been made in the preparation of this manual to ensure the accuracy of its contents. However, should you have any questions or find any errors, please contact BOVE TECHNOLOGY. ⚫ Copying or reproducing all or any part of the contents of this manual without the permission of BOVE TECHNOLOGY is strictly prohibited. Bove Intelligent Technology Co., Ltd Add: Level 5, Building 5, No. 36, Changsheng South Road, Jiaxing, Zhejiang, China, 314000 Tel: +86 573 83525916 Fax: +86 573 83525912 Email: [email protected] www.bovetech.com Copyright© 2023 Bove Intelligent Technology Co., Ltd CONTENT 1. General Information ..................................................................................................................................... 1 2. Technical Specification ................................................................................................................................ 1 2.1 Flow Sensor ............................................................................................................................................................................... 1 2.2 Calculator ................................................................................................................................................................................... 1 2.3 Completer meter ........................................................................................................................................................................ 2 2.4 Physical dimensions .................................................................................................................................................................... 4 3. Power Supply ............................................................................................................................................... 4 4. Interface & Communication ......................................................................................................................... 4 4.1 IrDA ............................................................................................................................................................................................ 4 4.2 M-BUS(Optional) ........................................................................................................................................................................ 4 4.3 RS485 (Optional) ....................................................................................................................................................................... 5 4.4 LoRaWAN (Optional) .................................................................................................................................................................. 5 4.5 Sigfox (Optional) ........................................................................................................................................................................ 5 5. Operation & Display ..................................................................................................................................... 6 5.1 Operations on how to display ..................................................................................................................................................... 7 6. Alert and Error ............................................................................................................................................ 12 7. FCC regulatory conformance ..................................................................................................................... 13 8. IC regulatory conformance ........................................................................................................................ 14 Copyright© 2023 Bove Intelligent Technology Co., Ltd 1. General Information Please note that the following installation conditions must be obeyed: Pressure requirement: MAP16. Electromagnetic environmental class: E1 Mechanical environmental class: M1 Mechanical environmental condition: B Installation requirement: There must be a minimum of 25 cm between signal cables and other installations. Note: Seal or any safety marks on the meter must not be damaged or removed and doing so will void the warranty and calibration of the meter. 2. Technical Specification 2.1 Flow Sensor The flow sensor is a device used to measure the velocity of flow by using the principle of ultrasound. It can measure the average velocity along the path of an emitted beam of ultrasound by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow. The flow measurement is based on an acoustic wave time of flight principle. The flow meter body is equipped with 2 ultrasonic transducers facing 2 acoustic reflectors. Flow sensor data: Manufacturer Bove Type BECO Y Accuracy class Class 2 MAP 16 bar Max pressure loss ≤ 63 kPa Max admissible temperature (optional) 30°C / 50°C / 70°C Limits of temperature (Θmin and Θmax) (optional) 0.1-30°C / 0.1-50°C / 0.1-70°C Installation requirements No straight pipe required Basic mounting orientation and other specified orientations 360° Mechanical environmental condition B Electromagnetic environmental class E1 Mechanical environmental class M1 2.2 Calculator Copyright© 2023 Bove Intelligent Technology Co., Ltd The calculator is a device that calculates the flow volume consumed based on signals from the flow sensor. It’s also the meter's control, display, and data store part. Calculator data: Manufacturer Bove Mechanical environmental condition …
Text truncated - open the document above for the full version.
Zhejiang Bove Intelligent Technology Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 10-07-2023 Ref: Attestation Statements Part 2.911(d)(S)(ii) Filing FCC ID: 2BCZQBECOY Zhejiang Bove Intelligent Technology Co., Ltd. certifies that, as of the date of the filing of the application, the applicant j!_ 血 identifie d on the Covered List (as a specifically named entity or any of its subsidiarie s or affiliates) as an entity producing "covered" equipment Sincerely, 少刁厄· Zhang Hua Rev 1/26/2023
Report No.: BL-SZ2390973-AW 1 / 4 EUT EXTERNAL PHOTOS FRONT VIEW OF EUT CLOSE-UP Report No.: BL-SZ2390973-AW 2 / 4 REAR VIEW OF EUT LEFT VIEW OF EUT Report No.: BL-SZ2390973-AW 3 / 4 RIGHT VIEW OF EUT TOP VIEW OF EUT Report No.: BL-SZ2390973-AW 4 / 4 BOTTOM VIEW OF EUT Accessory-Infrared Sensor --BLANK BELOW--
Report No.: BL-SZ2390973-AI 1 / 3 EUT INTERNAL PHOTOS EUT UNCOVER VIEW MAIN BOARD TOP VIEW (WITH SHIELDING) Report No.: BL-SZ2390973-AI 2 / 3 MAIN BOARD TOP VIEW (WITHOUT SHIELDING) MAIN BOARD REAR VIEW RF Chip Report No.: BL-SZ2390973-AI 3 / 3 Antenna BATTERY --BLANK BELOW-- FPC Antenna
Report No.: BL-SZ2390973-701 Tel: +86-755-66850100 E-mail: [email protected] Page No. 1 / 10 Web: www.titcgroup.com Template No.: TRP-FCC-Mobile (2022-08-15) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China TEST REPORT Applicant: Zhejiang Bove Intelligent Technology Co., Ltd. Address: Level 5, Building 5, No. 36, Changsheng South Road, Jiaxing, Zhejiang, China, 314000 Equipment Type: Ultrasonic Water Meter Model Name: BECOY Brand Name: BOVE TECHNOLOGY FCC ID: 2BCZQBECOY Test Standard: 47 CFR Part 2.1091 (refer to section 3.1) Sample Arrival Date: Sep. 21, 2023 Test Date: Sep. 25, 2023 - Sep. 26, 2023 Date of Issue: Sep. 27, 2023 ISSUED BY: Shenzhen BALUN Technology Co., Ltd. Tested by: Xiong Lining Checked by: Xu Rui Approved by: Tolan Tu (Testing Director) _______________ _______________ _______________ Report No.: BL-SZ2390973-701 Tel: +86-755-66850100 E-mail: [email protected] Page No. 2 / 10 Web: www.titcgroup.com Template No.: TRP-FCC-Mobile (2022-08-15) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Revision History Version Issue Date Revisions Content Rev. 01 Sep. 27, 2023 Initial Issue TABLE OF CONTENTS 1 GENERAL INFORMATION ......................................................................................................... 3 1.1 Test Laboratory .............................................................................................................. 3 1.2 Test Location .................................................................................................................. 3 2 PRODUCT INFORMATION ......................................................................................................... 4 2.1 Applicant Information ...................................................................................................... 4 2.2 Manufacturer Information ............................................................................................... 4 2.3 General Description for Equipment under Test (EUT) ................................................... 4 2.4 Ancillary Equipment ........................................................................................................ 4 2.5 Technical Information ..................................................................................................... 5 3 SUMMARY OF TEST RESULT ................................................................................................... 6 3.1 Test Standards ............................................................................................................... 6 4 DEVICE CATEGORY AND LEVELS LIMITS .............................................................................. 7 5 ASSESSMENT RESULT ............................................................................................................. 9 5.1 Output Power ................................................................................................................. 9 5.2 Tune-up power ............................................................................................................... 9 5.3 RF Exposure Evaluation Result ..................................................................................... 9 5.4 Conclusion ...................................................................................................................... 9 Report No.: BL-SZ2390973-701 Tel: +86-755-66850100 E-mail: [email protected] Page No. 3 / 10 Web: www.titcgroup.com Template No.: TRP-FCC-Mobile (2022-08-15) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1 GENERAL INFORMATION 1.1 Test Laboratory Name Shenzhen BALUN Technology Co., Ltd. Address Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Phone Number +86 755 6685 0100 1.2 Test Location Name Shenzhen BALUN Technology Co., Ltd. Location Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1/F, Building B, Ganghongji High-tech Intelligent Industrial Park, No. 1008, Songbai Road, Yangguang Community, Xili Sub-district, Nanshan District, Shenzhen, Guangdong Province, P. R. China Accreditation Certificate The laboratory is a testing organization accredited by FCC as a accredited testing laboratory. The designation number is CN1196. Report No.: BL-SZ2390973-701 Tel: +86-755-66850100 E-mail: [email protected] Page No. 4 / 10 Web: www.titcgroup.com Template No.: TRP-FCC-Mobile (2022-08-15) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 2 PRODUCT INFORMATION 2.1 Applicant Information Applicant Zhejiang Bove Intelligent Technology Co., Ltd. Address Level 5, Building 5, No. 36, Changsheng South Road, Jiaxing, Zhejiang, China, 314000 2.2 Manufacturer Information Manufacturer Zhejiang Bove Intelligent Technology Co., Ltd. Address Level 5, Building 5, No. 36, Changsheng South Road, Jiaxing, Zhejiang, China, 314000 2.3 General Description for Equipment under Test (EUT) EUT Name Ultrasonic Water Meter Model Name Under Test BECOY Series Model Name N/A Description of Model name differentiation N/A Hardware Version V1.2 Software Version V1.1.12 Dimensions (Approx.) N/A Weight (Approx.) N/A 2.4 Ancillary Equipment Ancillary Equipment 1 Battery Brand Name N/A Model No. ER26500 Serial No. N/A Capacitance 8500 mAh Rated Voltage 3.6 V Limit Charge Voltage N/A Ancillary Equipment 2 Battery Brand Name N/A Model No. SPC Serial No. N/A Capacitance 45 mAh Rated Voltage N/A Limit Charge Voltage N/A Report No.: BL-SZ2390973-701 Tel: +86-755-66850100 E-mail: [email protected] Page No. 5 / 10 Web: www.titcgroup.com Template No.: TRP-FCC-Mobile (2022-08-15) Add: Block B, 1/F, Baisha Science and Technology …
Text truncated - open the document above for the full version.
- 1 - SPECIFICATION FOR APPROVAL CUSTOMER:Zhejiang Bove Intelligent Technology Co., Ltd. UPPLIER:MyAntenna PRODUCT MODEL:B8-TH_V1.1 PRODUCT NAME:B8-TH_V1.1 FPC antenna PRODUCT CODE: M01-0400600R0A/M04-0101780R0A/ M04-0102580R0A CUSTOMER SIGNATURE: CUSTOMER SEAL: 供应商签名 SUPPLIERSIGNATURE :供应商盖章 SUPPLIERSEAL : 注意:请将此副本作为您的批准证明回签! NOTE:PLEASERETURNTHIS COPYAS A CERTIFICATIONOF YOURAPPROVAL 编制Preparedby : 董春玲 日期Date: 202 3.04 .10 Add: 深圳市南山科技园南区R3-A 栋 405 室 Tel:0755 -86503881 Fax: 0755 -27801677 - 3 - PERFORMANCE PARAMETER 1.Electrical Characteristics 1 Frequency Range 863MHz-928MHz 2V.S.W.R<3.5 3 peak Gain 0.89dBi 4 Impendence50Ω 5 Polarization linear polarization 2.Mechanical parameters 1Measure FPC:52.0*31.15mm/Φ1.13*60mm 2 颜色 Colour black 3.Environment Condition 1 Working Temp -40°C~85°C - 4 - TESTING CURVE 1. Matching circuit - 5 - TESTING CURVE 2. Performance test 2.1 V.S.W.R Data list Freq /M Hz863868915928 VSWR2.592.461.842.91 - 6 - TESTING CURVE 3. Passive testing 3.1 Efficiency and Gain - 7 - Data list Freq(MHz)Gain(dBi)EfficiencyFreq(MHz)Gain(dBi)Efficiency 863-0.5136.848980.8140.40 868-0.6336.579030.8941.62 8730.0540.219080.6140.43 8780.1040.829130.2237.68 8830.0639.26918-0.0435.43 8880.1838.389230.5435.61 8930.5139.089280.4832.28 - 8 - TESTING CURVE 3.2 3D Map 3.3 2D Figure - 9 - SCHEDULE DRAWING B8-TH_V1.1 V1.0 5 0~10 ±0.10 10~18±0.15 18~ 30±0.20 30~ 40±0.25 Third Angle 40~ ±0.30 Approved by Part No. Date Designed by Checked by Scale mm Location Project Material Part Name Unit RF Angle 1:1 深 圳 摩 天 射 频 技 术 有 限 公 司 ShenZhen MyAntenna RF Technology Co.,Ltd DWG No. Date B8-TH_V1.1天 线 A0 Rev New drawing Description Date 20220322 Remark No. Name Material ColorTreatmentAmountRemark 1 黑 色 1 1 2 黑 色 同 轴线 FPC B8-TH_V1.1 M01-0400600R0A 1 2 Φ1.13mm
Report No.: BL-SZ2390973-602 Tel: +86-755-66850100 E-mail: [email protected] Page No. 1 / 51 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China TEST REPORT Applicant: Zhejiang Bove Intelligent Technology Co., Ltd. Address: Level 5, Building 5, No. 36, Changsheng South Road, Jiaxing, Zhejiang, China, 314000 Equipment Type: Ultrasonic Water Meter Model Name: BECOY Brand Name: BOVE TECHNOLOGY FCC ID: 2BCZQBECOY Test Standard: 47 CFR Part 15 Subpart C (refer to section 3.1) Sample Arrival Date: Sep. 21, 2023 Test Date: Sep. 25, 2023 - Sep. 26, 2023 Date of Issue: Sep. 27, 2023 ISSUED BY: Shenzhen BALUN Technology Co., Ltd. Tested by: Yu Yingyuan Checked by: Ye Hongji Approved by: Liao Jianming (Technical Director) _______________ _______________ _______________ Report No.: BL-SZ2390973-602 Tel: +86-755-66850100 E-mail: [email protected] Page No. 2 / 51 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Revision History Version Issue Date Revisions Rev. 01 Sep. 27, 2023 Initial Issue TABLE OF CONTENTS 1 GENERAL INFORMATION ......................................................................................................... 4 1.1 Test Laboratory .............................................................................................................. 4 1.2 Test Location .................................................................................................................. 4 2 PRODUCT INFORMATION ......................................................................................................... 5 2.1 Applicant Information ...................................................................................................... 5 2.2 Manufacturer Information ............................................................................................... 5 2.3 General Description for Equipment under Test (EUT) ................................................... 5 2.4 Technical Information ..................................................................................................... 6 3 SUMMARY OF TEST RESULTS ................................................................................................. 7 3.1 Test Standards ............................................................................................................... 7 3.2 Test Verdict .................................................................................................................... 7 4 GENERAL TEST CONFIGURATIONS ........................................................................................ 8 4.1 Test Environments ......................................................................................................... 8 4.2 Test Equipment List ........................................................................................................ 8 4.3 Measurement Uncertainty .............................................................................................. 8 4.4 Description of Test Setup ............................................................................................... 9 4.5 Measurement Results Explanation Example ................................................................ 12 5 TEST ITEMS .............................................................................................................................. 13 5.1 Antenna Requirements ................................................................................................. 13 5.2 Output Power ............................................................................................................... 14 5.3 Occupied Bandwidth .................................................................................................... 16 5.4 Conducted Spurious Emission ..................................................................................... 17 5.5 Band Edge (Authorized-band band-edge) .................................................................... 19 5.6 Conducted Emission .................................................................................................... 21 Report No.: BL-SZ2390973-602 Tel: +86-755-66850100 E-mail: [email protected] Page No. 3 / 51 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 5.7 Radiated Spurious Emission ........................................................................................ 22 5.8 Band Edge (Restricted-band band-edge) ..................................................................... 24 5.9 Power Spectral density (PSD) ...................................................................................... 25 ANNEX A TEST RESULT ............................................................................................................. 26 A.1 Output Power ............................................................................................................... 26 A.2 Occupied Bandwidth .................................................................................................... 27 A.3 Conducted Spurious Emissions ................................................................................... 29 A.4 Band Edge (Authorized-band band-edge) .................................................................... 32 A.5 Conducted Emissions ................................................................................................... 33 A.6 Radiated Spurious Emission ........................................................................................ 34 A.7 Band Edge (Restricted-band band-edge) ...................................................................…
Text truncated - open the document above for the full version.
Report No.: BL-SZ2390973-AR 1 / 4 TEST SETUP PHOTOS 1 Radiated Test Photo Below 30MHz Close-up Report No.: BL-SZ2390973-AR 2 / 4 30MHz-1GHz Close-up Report No.: BL-SZ2390973-AR 3 / 4 Above 1GHz Close-up Report No.: BL-SZ2390973-AR 4 / 4 2 Conducted Test Photo Conducted Test-LoRa-Hopping Conducted Test-LoRa-DTS --BLANK BELOW--
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 915.9 MHz - 927.1 MHz | 55.90 mW |