FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Quanzhou Wurui Electronics Co., Ltd./
  3. 2BD8I-GLOBAL-PTT

2BD8I-GLOBAL-PTTWALKIETALKIE

Quanzhou Wurui Electronics Co., Ltd.
WALKIETALKIE - FCC ID 2BD8I-GLOBAL-PTT - Quanzhou Wurui Electronics Co., Ltd.
Click to zoom

Application Details

Equipment Class
PCF - PCS Licensed Transmitter held to face
Date of Grant
Jan 04, 2024
Application Purpose
Original Equipment
Date of Application
Jan 04, 2024
Equipment Note
WALKIETALKIE
Frequency Range
2565.00000000 - 2645.00000000
Company
Quanzhou Wurui Electronics Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1.Key description 1. PTT  PTT key 2. Key 1:  Signal status 3. Key 2:  Battery status 4. Knob 1:  Power/ volume 5. Knob 2:  switch 2.Indicator light status Indicator light Tx red Rx green charging red Finish charging green This device complies with part 15 of the FCC Rules . Operation is subject to the following two condit ions: (1) this device ma y not cau se harmfu l interference, an d (2) this device must accept any interference received, including interference tha t ma y cau se undesired operation. Any changes or modifications not expres sly approved by th e party responsible for compliance coul d voi d th e user's authority to operate the equipment. NOTE: This equipment has been tested an d foun d to comp ly with th e limits for a Class B digital device, pursuant to Pa rt 15 of the FCC Rules . Thes e limits are designed to provid e reasonable protection against harmful interference in a residential installation. This equipment generates, use s an d ca n radiat e rad io frequency energ y and, if no t installed an d use d in accordance with th e instructions, ma y cau se harmful interference to radio communications. However, the re is n o guarantee tha t interference will no t occur i n a particular installation. If this equipment does cause harmful interference to radio or television reception, which ca n be determined by turn ing th e equipment off an d on , the user is encouraged to try to correc t the interference by one or mo re of the following measures: -- Reorient or relocate the receiving antenna. -- Increa se th e separation betwee n th e equipment an d receiver. -- Connect the equipment into an outle t on a circu it different from tha t to which th e receiver is connected. -- Consu lt th e dealer or an experienced radio/TV technician for help. The devic e has bee n evaluated to mee t genera l RF exposu re requirement. The dev ice ca n be used in portable exposure condit ion withou t restriction Specifi c Absorption Rate (SAR) information: This product meets the government's requirements for exposure to radi o wave s. The guidelines are base d on standards that were deve loped by independent scientific organizations through periodic an d thorough evaluation of scientific studies. The standards include a substantial safe ty margin designed to assu re the safe ty of all persons regardless of ag e or health. FCC RF Exposure Information and Statement The SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. Device types: G5 (FCC ID: 2BD8I-GLOBAL-PTT) has also been tested against this SAR limit. The highest SAR value reported under this standard during product certification for properly worn on the body is 1.30 W/Kg, Hotspot is 1.30 W/Kg, Front of face is 0.49 W/Kg. This device was tested for typical body -worn operations with the product kept 10mm from the body. To maintain compliance with FCC RF exposure requirements, use accessories that maintain a 10mm separation distance between the user's body and the product. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided. Body-worn Operation This device was tested for typical body-worn operations. To comply with RF exposure requirements, a minimum separation distance of 10mm must be maintained between the user' s body and the product, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body-worn accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna.

Attestation Statements

(Quanzhou Wurui Electronics Co., Ltd.) (December 23, 2023) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2BD8I-GLOBAL-PTT) [Quanzhou Wurui Electronics Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) CHEN XIANWU (Quanzhou Wurui Electronics Co., Ltd.) (December 23, 2023) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2BD8I-GLOBAL-PTT) [Quanzhou Wurui Electronics Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) CHEN XIANWU

Cover Letter(s)

Quanzhou Wurui Electronics Co., Ltd. (December 23, 2023) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (WALKIETALKIE / G5, G0, G1, G2, G3, G4, G6, G7, G8, G9, G10, G11, G12, G13, G14, G15, G16, G17, G18, G19, G20, G300, G318, G388, G500, G5288 / FCC ID: 2BD8I-GLOBAL-PTT ) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☒ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: CHEN XIANWU Title: General Manager

Cover Letter(s)

Quanzhou Wurui Electronics Co., Ltd. (December 22, 2023) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTB Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: CHEN XIANWU Title: General Manager

External Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 4 Model: G5 External Photos ANT Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 4

ID Label/Location Info

FCC ID LABEL: Label Location: FCC ID: 2BD8I-GLOBAL-PTT Model: G5

Internal Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 7 Model: G5 Internal Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 7 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 7 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 7 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 5 of 7 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 6 of 7 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 7 of 7

RF Exposure Info

Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 85 TEST REPORT Compiled by: Reviewed by: Approved by: Zhang Mao cheng Martin Feng Rita Xiao / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Product Name: WALKIETALKIE FCC ID: 2BD8I-GLOBAL-PTT Trademark: global-ptt Model Number: G5, G0, G1, G2, G3, G4, G6, G7, G8, G9, G10, G11, G12, G13, G14, G15, G16, G17, G18, G19, G20, G300, G318, G388, G500, G5288 Prepared For: Quanzhou Wurui Electronics Co., Ltd. Address: No. 6, Xiaguang 4th, Xiamei Village, Xiamei Town, Nanan City, Quanzhou City, Fujian Province Manufacturer: Quanzhou Wurui Electronics Co., Ltd. Address: No. 6, Xiaguang 4th, Xiamei Village, Xiamei Town, Nanan City, Quanzhou City, Fujian Province Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Oct. 18, 2023 Sample tested Date: Oct. 18, 2023 to Dec. 15, 2023 Issue Date: Dec. 15, 2023 Report No.: CTB231214040RHX Test Standards FCC 47 CFR Part2(2.1093), FCC 47 CFR Part1( 1.1310) FCC 47 CFR Part1( 1.1307), ANSI/IEEE C95.1-2019 IEEE 1528-2013 & Published RF Exposure KDB Procedures Test Results PASS Remark: This is SAR test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB231214040RHX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 85 Contents Page 1 COVER PAGE ......................................................................................................................................... 1 CONTENTS ....................................................................................................................................................................... 2 1. VERSION .................................................................................................................................................................. 4 2. PRODUCT INFORMATION AND TEST SETUP............................................................................................... 5 2.1 PRODUCT INFORMATION ................................................................................................................................... 5 3 EQUIPMENT USED DURING TEST ................................................................................................................... 6 3.1 EQUIPMENT LIST ............................................................................................................................................... 6 3.2 TEST EQUIPMENT CALIBRATION ....................................................................................................................... 7 4 SAR INTRODUCTION ........................................................................................................................................... 8 4.1 INTRODUCTION .................................................................................................................................................. 8 4.2 SAR DEFINITION ............................................................................................................................................... 8 5 SAR MEASUREMENT SETUP ............................................................................................................................. 9 5.1 SAR MEASUREMENT SETUP ...................................................................................................................... 9 5.2 DASY5 E-FIELD PROBE SYSTEM .................................................................................................................... 10 5.3 PROBE SPECIFICATION ..................................................................................................................................... 10 5.4 ISOTROPIC E-FIELD PROBE .............................................................................................................................. 10 5.5 PHANTOMS ...................................................................................................................................................... 11 5.6 DEVICE HOLDER .............................................................................................................................................. 11 6 SAR TEST PROCEDURE .................................................................................................................................... 12 6.1 SCANNING PROCEDURE ................................................................................................................................... 12 6.2 EXTRAPOLATION ............................................................................................................................................. 15 6.3 EAR REFERENCE POINT ................................................................................................................................... 15 6.4 DEVICE REFERENCE POINTS ............................................................................................................................ 15 6.5 TEST CONFIGURATION – POSITIONING FOR CHEEK / TOUCH ........................................................................... 15 6.6 TEST CONFIGURATION – POSITIONING FOR EAR / 15° TILT ............................................................................. 17 6.7 TEST POSITION – BODY CONFIGURATIONS .......................…

Text truncated - open the document above for the full version.

RF Exposure Info

In Collaboratio n wi th CALIBRATION LABORATORY 尺咚多���中 国认 可 舫CNAS校准 国 际互 认 -:;" - ^ Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, China ...... � 左心、 § 、骂雪 Tel: +86-10-62304633-2079 Fax: +86-10-62304633-2504 E-mail: [email protected] http://www.chinattl.cn Client CTB Certificate No: 223-60014 CALIBRATION CERTIFICATE Object Calibration P「ocedure(s) Calibration date D2600V2 - SN: 1101 FF-211-003-01 Calibration Procedures for dipole validation kits January 12, 2023 This calib「ationCertificate documents the traceab小tyto national standa「ds,which realize the physical units of measu 「ements(SI).The measurements and the uncertainties with confidence p「obab仆ityare given on the following pages and are part of the certificate All calibrations have been conducted in the closed labo「atoryfacility: environment temperature(22士3) ° C and humidity<70%. Calibration Equipment used (M&TE c咄calfor calibration) Primary Standards ID# Cal Date(Calibrated by, Cert巾cateNo.) Scheduled Calibration Power Meter NRP2 106276 May-23 Power sensor NRP6A 101369 May-23 Reference Probe EX3DV4 SN 7600 Nov-23 DAE4 SN 771 Feb-23 Secondary Standards ID# 12-May-22(CTTL, No.J20X02965) 12-May-22(CTTL, No.J20X02965) 30-Nov-22(CTTL-SPEAG, No.Z20-60421) 1 O-Feb-22(CTTL-SPEAG, No.Z20-60017) Cal Date(Calibrated by, Certificate No.) Scheduled Calibration Signal Generate「E4438C MY49071430 25-Feb-22 (CTTL, No.J20X00516) Network Analyzer E5071 C MY46110673 10-Feb-22 (CTTL, No.J20X00515) Feb-23 F eb-23 Name Function Signature Calibrated by: Zhao Jing SAR Te st Engineer it Reviewed by: Lin Hao SAR Test Engineer 啡羌 Approved by: Qi Dianyuan SAR Project Leader 一分三 Issued: January 15, 2023 This calibration certificate shall not be reproduced except in full without written approval of the laboratory Certificate No: Z23-600 I 4 Page I of 6 In Collaboration with 呈 CALIBRATION LABORATORY Add: No.51 Xueyuan Road, Hai小anDistrict, Beijing, 100191, China Tel: +86-10-62304633-2079 Fax: +86-10-62304633-2504 E-mail: [email protected] http://www.chinattl.cn Glossary: TSL ConvF NIA tissue simulating liquid sensitivity in TSL / NORMx,y,z not applicable or not measu「ed Calibration is Performed According to the Following Standards: a)I EC/IEEE 62209-1528, "Measurement Procedure for The Assessment of Specific Absorption Rate of Human Exposure to Radio Frequency Fields from Hand-held and Body-mounted Wireless Communication Devices- Part 1528: Human Models, Instrumentation and Procedures (Frequency range of 4 MHz to 10 GHz)", October 2020 b)KDB 865664, "SAR Measurement Requirements for 100 MHz to 6 GHz" . . . . Additional Documentation: c) DASY4/5 System Handbook Methods Applied and Interpretation of Parameters: . Measurement Conditions: Further details are available from the Validation Report at the end of the certificate. All figures stated in the certificate are valid at the frequency indicated. . Antenna Parameters with TSL: The dipole is mounted with the spacer to position its feed point exactly below the center marking of the flat phantom section, with the arms oriented p arallel to the body axis. . Feed Point Impedance and Return Loss: These parameters are measured with the dipole positioned under the liquid filled phantom. The impedance stated is transformed from the measurement at the SMA connector to the feed point. The Return Loss ensures low reflected power. No uncertainty required. Electrical Delay: One-way delay between the SMA connector and the antenna feed point No uncertainty required. SAR measured: SAR measured at the stated antenna input power. SAR normalized: SAR as measured, normalized to an input power of 1 Wat the antenna connector. SAR for nominal TSL parameters: The measured TSL parameters are used to calculate the nominal SAR result. The reported uncertainty of measurement is stated as the standard uncertainty of Measurement multiplied by the coverage factor k=2, which for a normal distribution Corresponds to a coverage probability of approximately 95% Certificate No: Z23-60014 Page 2 of 6 In Collabo rati on with CALIBRATION LABORATORY Add: No.51 Xueyuan Road, Haidian District, Beijing, I 00191, China Tel: +86-10-62304633-2079 Fax: +86-10-62304633-2504 E-mail: [email protected] http://www.chinattl.cn Measurement Conditions DASY system configuration, as fa DASY Version DASY52 V52.10.4 Extrapolation Advanced Extrapolation Phantom Triple Flat Phantom 5.1 C Distance Dipole Center - TSL 10 mm with Spacer Zoom Scan Resolution dx, dy, dz = 5 mm Frequency 2600 MHz土1MHz Head TSL parameters The fo Temperature Permittivity Conductivity Nominal Head TSL parameters 22.0 ° C 39.0 1.96 mho/m Measured Head TSL parameters (22 0士0.2) ° C 40.1士6% 1.95 mho/m士6% Head TSL temperature change during test <1.0 ° C ---- ---- d a pplied SAR result with Head TSL 3 Condition SAR averaged over 1 cm (1 g) of Head TSL SAR measured 250 mW input power 14.2 W/kg SAR to「 nominalHead TSL parameters no「malizedto 1 W 57.3 W/kg士18.8% (/r-2) 3 Condition SAR averaged over 10 cm (10 g) of Head TSL SAR measured 250 mW input power 6.25 W/kg SAR for nominal Head TSL parameters normalized to 1 W 25.1 W/kg士18.7% (/r-2) Certificate No: Z23-60014 Page 3 of 6 ln Collaborati on with CALIBRATION LABORATORY Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, Chma Tel: +86-10-62304633-2079 Fax: +86-10-62304633-2504 E-mail: [email protected] http://www.chinattl.cn Appendix(Additional assessments outside the scope of CNAS L0570) Antenna Parameters with Head TSL Impedance, transfo「med to feed point 48.40-6.46j0 Return Loss - 23.4d8 General Antenna Parameters and Design Electrical Delay (one direction) 1.065 ns After long term use with 1 OOW radiated power, only a slight warming of the dipole near the feed point can be measured. The dipole is made of standard semi rigid coaxial cable. The center conductor of the feeding line is directly connected to the second arm of the dipole. The antenna is therefore short-circuited for DC-signals. On some of the dipoles, small end caps a「e…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT Compiled by: Reviewed by: Approved by: Zhou Kui Arron Liu Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Product Name: WALKIETALKIE FCC ID: 2BD8I-GLOBAL-PTT Trademark: global-ptt Model Number: G5, G0, G1, G2, G3, G4, G6, G7, G8, G9, G10, G11, G12, G13, G14, G15, G16, G17, G18, G19, G20, G300, G318, G388, G500, G5288 Prepared For: Quanzhou Wurui Electronics Co., Ltd. Address: No. 6, Xiaguang 4th, Xiamei Village, Xiamei Town, Nanan City, Quanzhou City, Fujian Province Manufacturer: Quanzhou Wurui Electronics Co., Ltd. Address: No. 6, Xiaguang 4th, Xiamei Village, Xiamei Town, Nanan City, Quanzhou City, Fujian Province Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Oct. 18, 2023 Sample tested Date: Oct. 18, 2023 to Dec. 05, 2023 Issue Date: Dec. 05, 2023 Report No.: CTB231205005RFX Te s t Standards FCC Part 2, 22, 24E, 27 Test Results PASS Remark: This is LTE radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB231205005RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 36 TABLE OF CONTENT Test Report Declaration Page 1. VERSION ........................................................................................................................................ 3 2. TEST SUMMARY ........................................................................................................................... 4 3. MEASUREMENT UNCERTAINTY ................................................................................................. 5 4. PRODUCT INFORMATION AND TEST SETUP ............................................................................ 6 4.1 Product Information .......................................................................................................................... 6 4.2 Test Setup Configuration .................................................................................................................. 7 4.3 Support Equipment........................................................................................................................... 7 4.4 Test Mode ........................................................................................................................................ 7 4.5 Test Environment ............................................................................................................................. 7 5. TEST FACILITY AND TEST INSTRUMENT USED ....................................................................... 8 5.1 Test Facility ...................................................................................................................................... 8 5.2 Test Instrument Used ....................................................................................................................... 8 6. RF EXPOSURE ............................................................................................................................ 10 6.1 Standard Applicable ....................................................................................................................... 10 6.2 Test Result ..................................................................................................................................... 10 7. RF OUTPUT POWER ................................................................................................................... 11 7.1 Standard Applicable ....................................................................................................................... 11 7.2 Test Procedure ............................................................................................................................... 11 7.3 Summary of Test Results/Plots ...................................................................................................... 12 8. PEAK-TO-AVERAGE RATIO (PAR) OF TRANSMITTER ........................................................... 24 8.1 Standard Applicable ....................................................................................................................... 24 8.2 Test Procedure ............................................................................................................................... 24 8.3 Summary of Test Results ............................................................................................................... 24 9. EMISSION BANDWIDTH ............................................................................................................. 25 9.1 Standard Applicable ....................................................................................................................... 25 9.2 Test Procedure ............................................................................................................................... 25 9.3 Summary of Test Results/Plots ...................................................................................................... 25 10. OU T OF BAND EMISSIONS AT ANTENNA TERMINAL ............................................................ 26 10.1 Standard Applicable ..................................................................................................................... 26 10.2 Test Procedure ......................................…

Text truncated - open the document above for the full version.

Test Report

Report 1 Conducted output power Band Bandwidth (MHz) UL Channel RB Size RB Position Modulation Power (dBm) high Limit (dBm) Verdict Band2 1.4 18607 1 #0 QPSK 24.64 37 PASS Band2 1.4 18607 1 #Mid QPSK 24.68 37 PASS Band2 1.4 18607 1 #Max QPSK 24.61 37 PASS Band2 1.4 18607 3 #0 QPSK 24.54 37 PASS Band2 1.4 18607 3 #Max QPSK 24.53 37 PASS Band2 1.4 18607 6 #0 QPSK 23.43 37 PASS Band2 1.4 18607 1 #0 QAM16 23.48 37 PASS Band2 1.4 18607 1 #Mid QAM16 23.55 37 PASS Band2 1.4 18607 1 #Max QAM16 23.48 37 PASS Band2 1.4 18607 3 #0 QAM16 23.58 37 PASS Band2 1.4 18607 3 #Max QAM16 23.65 37 PASS Band2 1.4 18607 6 #0 QAM16 22.34 37 PASS Band2 1.4 18900 1 #0 QPSK 23.63 37 PASS Band2 1.4 18900 1 #Mid QPSK 23.65 37 PASS Band2 1.4 18900 1 #Max QPSK 23.56 37 PASS Band2 1.4 18900 3 #0 QPSK 23.60 37 PASS Band2 1.4 18900 3 #Max QPSK 23.55 37 PASS Band2 1.4 18900 6 #0 QPSK 22.74 37 PASS Band2 1.4 18900 1 #0 QAM16 22.91 37 PASS Band2 1.4 18900 1 #Mid QAM16 22.94 37 PASS Band2 1.4 18900 1 #Max QAM16 22.89 37 PASS Band2 1.4 18900 3 #0 QAM16 22.75 37 PASS Band2 1.4 18900 3 #Max QAM16 22.73 37 PASS Band2 1.4 18900 6 #0 QAM16 21.84 37 PASS Band2 1.4 19193 1 #0 QPSK 23.41 37 PASS Band2 1.4 19193 1 #Mid QPSK 23.37 37 PASS Band2 1.4 19193 1 #Max QPSK 23.24 37 PASS Band2 1.4 19193 3 #0 QPSK 23.38 37 PASS Band2 1.4 19193 3 #Max QPSK 23.22 37 PASS Band2 1.4 19193 6 #0 QPSK 22.45 37 PASS Band2 1.4 19193 1 #0 QAM16 22.40 37 PASS Band2 1.4 19193 1 #Mid QAM16 22.32 37 PASS Band2 1.4 19193 1 #Max QAM16 22.22 37 PASS Band2 1.4 19193 3 #0 QAM16 22.43 37 PASS Band2 1.4 19193 3 #Max QAM16 22.30 37 PASS Band2 1.4 19193 6 #0 QAM16 21.65 37 PASS Band2 3 18615 1 #0 QPSK 24.55 37 PASS Band2 3 18615 1 #Mid QPSK 24.57 37 PASS Band2 3 18615 1 #Max QPSK 24.44 37 PASS Band2 3 18615 8 #0 QPSK 23.40 37 PASS Band2 3 18615 8 #Max QPSK 23.50 37 PASS Report Band2 3 18615 15 #0 QPSK 23.40 37 PASS Band2 3 18615 1 #0 QAM16 23.63 37 PASS Band2 3 18615 1 #Mid QAM16 23.69 37 PASS Band2 3 18615 1 #Max QAM16 23.67 37 PASS Band2 3 18615 8 #0 QAM16 22.33 37 PASS Band2 3 18615 8 #Max QAM16 22.35 37 PASS Band2 3 18615 15 #0 QAM16 22.25 37 PASS Band2 3 18900 1 #0 QPSK 23.63 37 PASS Band2 3 18900 1 #Mid QPSK 23.63 37 PASS Band2 3 18900 1 #Max QPSK 23.60 37 PASS Band2 3 18900 8 #0 QPSK 22.75 37 PASS Band2 3 18900 8 #Max QPSK 22.73 37 PASS Band2 3 18900 15 #0 QPSK 22.70 37 PASS Band2 3 18900 1 #0 QAM16 22.90 37 PASS Band2 3 18900 1 #Mid QAM16 22.88 37 PASS Band2 3 18900 1 #Max QAM16 22.81 37 PASS Band2 3 18900 8 #0 QAM16 21.96 37 PASS Band2 3 18900 8 #Max QAM16 21.93 37 PASS Band2 3 18900 15 #0 QAM16 21.80 37 PASS Band2 3 19185 1 #0 QPSK 23.46 37 PASS Band2 3 19185 1 #Mid QPSK 23.42 37 PASS Band2 3 19185 1 #Max QPSK 23.15 37 PASS Band2 3 19185 8 #0 QPSK 22.48 37 PASS Band2 3 19185 8 #Max QPSK 22.43 37 PASS Band2 3 19185 15 #0 QPSK 22.42 37 PASS Band2 3 19185 1 #0 QAM16 22.42 37 PASS Band2 3 19185 1 #Mid QAM16 22.34 37 PASS Band2 3 19185 1 #Max QAM16 22.11 37 PASS Band2 3 19185 8 #0 QAM16 21.71 37 PASS Band2 3 19185 8 #Max QAM16 21.67 37 PASS Band2 3 19185 15 #0 QAM16 21.62 37 PASS Band2 5 18625 1 #0 QPSK 24.74 37 PASS Band2 5 18625 1 #Mid QPSK 24.70 37 PASS Band2 5 18625 1 #Max QPSK 24.57 37 PASS Band2 5 18625 12 #0 QPSK 23.42 37 PASS Band2 5 18625 12 #Max QPSK 23.41 37 PASS Band2 5 18625 25 #0 QPSK 23.47 37 PASS Band2 5 18625 1 #0 QAM16 23.91 37 PASS Band2 5 18625 1 #Mid QAM16 23.86 37 PASS Band2 5 18625 1 #Max QAM16 23.78 37 PASS Band2 5 18625 12 #0 QAM16 22.23 37 PASS Band2 5 18625 12 #Max QAM16 22.24 37 PASS Band2 5 18625 25 #0 QAM16 22.37 37 PASS Band2 5 18900 1 #0 QPSK 23.87 37 PASS Report Band2 5 18900 1 #Mid QPSK 23.72 37 PASS Band2 5 18900 1 #Max QPSK …

Text truncated - open the document above for the full version.

Contact Information

Applicant

XIANWU CHEN
[email protected]13538214502Fax: 13538214502

Test Firm

Shenzhen CTB Testing Technology Co., Ltd.Rita Xiao
[email protected]86-13538218145

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
14272.56 GHz - 2.65 GHz319.15 mW18M0W7D0.1 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is ERP for frequencies below 1 GHz, and EIRP for frequencies above1 GHz. This device supports bandwidths of 1.4/3/5/10/15/20 MHz for LTE Bands 2 and 4, bandwidths of 1.4/3/5/10 MHz for LTE Band 5, bandwidths of 5/10/15/20 MHz for LTE Bands 7, 38 and 41, and bandwidths of 5/10 MHz for LTE Bands 40. For body worn operation, this product has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the product a minimum of 10mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. Highest reported SAR for Head (front of face), Body-worn accessory and product specific (wireless router) are 0.49W/kg, 1.30W/kg, 1.30W/kg respectively.