Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Model: X380 Robotic vacuum cleaner Use only with <K12V190060U> supply unit / {X380} docking station Zhiyi (Zhongshan) Technology Co., Ltd. No. 39, Donghui Road, Cuiheng New District,528400 Zhongshan, Guangdong, PEOPLE'S REPUBLIC OF CHINA Input: 19V 0.6A Battery: Li-ion www.iliferobot.com MADE IN CHINA FCC ID2BD8J-X380 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. LABEL Label location
LABEL Label location Model: X380S Robotic vacuum cleaner Zhiyi (Zhongshan) Technology Co., Ltd. No. 39, Donghui Road, Cuiheng New District,528400 Zhongshan, Guangdong, PEOPLE'S REPUBLIC OF CHINA Input: 19V 0.6A Battery: Li-ion Use only with {X380S} docking station www.iliferobot.com MADE IN CHINA FCC ID2BD8J-X380 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Report Number: 68.910.24.0034.01A EMC_SZ_FR_23.03 MPE Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 8 FCC Maximum Permissible Exposure (MPE) Report Report Number : 68.910.24.0034.01A Date of Issue: 2024-07-26 Model : X380, X380W, X380S, X381, X381S, X382, X382S, G9, V9, G9 Pro, V9 Pro, V9 Plus Product Type : Robotic Vacuum Cleaner Applicant : Zhiyi (Zhongshan) Technology Co., Ltd. Address : No. 39, Donghui Road, Cuiheng New District, 528400 Zhongshan, Guangdong, PEOPLE’S REPUBLIC OF CHINA Manufacturer : Zhiyi (Zhongshan) Technology Co., Ltd. Address : No. 39, Donghui Road, Cuiheng New District, 528400 Zhongshan, Guangdong, PEOPLE’S REPUBLIC OF CHINA Test Result : ◼ Positive Negative Total pages including Appendices : 8 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 68.910.24.0034.01A EMC_SZ_FR_23.03 MPE Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 8 1 Table of Contents 1 Table of Contents .................................................................................................................. 2 2 Details about the Test Laboratory .......................................................................................... 3 3 Description of the Equipment Under Test .............................................................................. 4 4 General Information ............................................................................................................... 5 5 RF Exposure Requirements ................................................................................................... 6 6 FCC MPE Limits .................................................................................................................... 7 7 RF Exposure Evaluation (FCC) ............................................................................................. 8 7.1 Calculation of Power Density for Single Transmission.................................................... 8 7.2 Conclusion ...................................................................................................................... 8 Report Number: 68.910.24.0034.01A EMC_SZ_FR_23.03 MPE Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 8 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, 518052 China FCC Designation Number: CN5009 FCC Registration No.: 514049 Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 Report Number: 68.910.24.0034.01A EMC_SZ_FR_23.03 MPE Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 8 3 Description of the Equipment Under Test Product: Robotic Vacuum Cleaner Model no.: X380, X380W, X380S, X381, X381S, X382, X382S, G9, V9, G9 Pro, V9 Pro, V9 Plus FCC ID: 2BD8J-X380 Ratings: For X380, X380W, X381, X382, G9 and V9: 19V, 0.6A (for robotic vacuum cleaner); 100-240V, 50/60Hz, 0.35A (for AC adapter) For X380S, X381S, X382S, G9 Pro, V9 Pro and V9 Plus: 19V, 0.6A (for robotic vacuum cleaner); 120VAC, 60Hz, 550W (for Dust collector station) Battery: 14.4Vdc, 2.6Ah Accessories: Dust collector station & Docking station & AC adapter RF Transmission Frequency: 2412MHz-2462MHz No. of Operated Channel: 11 for 802.11b/g/n20; 7 for 802.11n40 Modulation: 802.11b: CCK, DSSS 802.11g/n20/n40: BPSK, QPSK, 16-QAM, 64-QAM Antenna Type: PCB antenna Antenna Gain: 0.86 dBi Description of the EUT: The EUT is a Robotic Vacuum Cleaner supports 2.4GHz Wi-Fi function. NOTE 1: The above EUT’s information is declared by manufacturer. Please refer to the specifications or user’s manual for more detailed description. Model differences as below: Item Model No. Charging unit Remark: a X380, X380W, X381, X382, G9, V9 AC adapter X380 and other models (X380W, X381, X382, G9, V9) are the same except the different appearance and model name. b X380S, X381S, X382S, G9 Pro, V9 Pro, V9 Plus Dust collector station X380 and X380S are the same except the charging unit, different appearance and model name. All models in this item b are the same except the different appearance and model name. All models have same schematics, PCB layout and RF module, only the charging accessories is different. Unless otherwise specified, the model X380 was chosen as representative model to perform all the tests. Report Number: 68.910.24.0034.01A EMC_SZ_FR_23.03 MPE Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 5 of 8 4 General Information Any use for advertising purposes must be granted in writing. This technical report may…
Text truncated - open the document above for the full version.
±♠≠...↔♠↑≡↑∑ ⊂•±÷•∂ ⋅∂÷•∫∧≥ƒ∂±÷ ∨≥≡...↔↑°±∂...← ⊄≡...•±°≥°÷ƒ ⇐°〉⌠ ↔≈ ⇒≈≈↑≡←←∑ ⇑♠∂≥≈∂±÷ ⌠ ∇°〉 ⊕♠ ⇐•°±÷∞•∂ ⊆°≈⌠ ∉♠≈°±÷ ⇔∂←↔↑∂...↔⌠ ⌠ ⊂•±÷•∂⌠ ⇐•∂± ⇒±↔≡±± ∇′′≡∑ ⋅∧∫∉⊄ ∠±∫°↑≈ ⇐•∂↓ ⇒±↔≡±± ⇒±↔≡±± ⊄ƒ↓≡∑ ∉⇐⇑ ±↔≡±± ⇒±↔≡±± ∧↑≡→♠≡±...ƒ ⇑±≈∑ ∫⋅∞ ⇒±↔≡±± ¬∂±∑ 〉 ♣〉 ⋅∧∫∉⊄ ⇒±↔≡±± ⊂↓≡...∂≠∂...↔∂°± Outline Summary Purpose Antenna design and test for Mojito. Result as following. Agenda Test Environment and Equipment Antenna Positions Test Result : VSWR Test Result : Efficiency Test Result : 2D Radiation Pattern Result & Suggestions S-Parameter test Testing range from 9KHz to 8.5GHz or 300KHz~6.5GHz Network Analyzer(Agilent-E5071C or R&S ZVL) Test Environment and Equipments The Gain, Efficiency,Directivity and 2/3D Pattern 3D Anechoic Chamber Testing range from 700MHz to 6GHz Chamber Room Size: L*W*H=9*4.7*4.7 M VSWR Testing range from 9KHz to 8.5GHz or 300KHz~6.5GHz Network Analyzer(Agilent-E5071C or R&S ZVL) Test Environment and Equipments Dimension 3D Total Date Total/Fr equency Ant. Port Input Tot.Rad.Pwr .(dBm) Peak EIRP(dBm) Directivity (dBi) Efficienc y(dB) Efficiency (%) Gain(dBi) 2400 0 -3.361413 0.389235 3.750648 -3.361413 46.116748 0.389235 2412 0 -3.50011 0.670378 4.170489 -3.50011 44.6672240.670378 2437 0 -3.422525 0.246844 3.669369 -3.422525 45.472360.246844 2442 0 -3.515487 0.299056 3.814544 -3.515487 44.5093510.299056 2450 0 -3.602275 0.864485 4.46676 -3.602275 43.6287240.864485 2462 0 -3.497353 0.488575 3.985927 -3.497353 44.6955950.488575 2484 0 -3.579493 0.226577 3.80607 -3.579493 43.8581880.226577 2500 0 -3.611696 1.051473 4.663169 -3.611696 43.5341821.051473 0 0.2 0.4 0.6 0.8 1 1.2 24002412243724422450246224842500 Gain(dBi) 42 43 44 45 46 47 48 49 50 24002412 243724422450246224842500 Efficiency(%) Frequency = 2400 MHz d BmXY- Pl aneXZ- Pl aneYZ- Pl ane H- Pol . ( Peak. )0. 139977- 2. 090171 - 3. 032668 V- Pol . ( Peak. )- 3. 795009- 5. 1371- 3. 269062 H+V. (Peak.)0. 389235- 1. 523236- 0. 898339 H- Pol . ( Avg. )- 3. 264823- 5. 228177- 7. 948598 V- Pol . ( Avg. )- 8. 029977- 10. 711423- 8. 683427 H+ V. ( Av g . )- 2. 01392- 4. 146155- 5. 290189 AngleXY-PlaneXZ-PlaneYZ-Plane H- Pol . ( Peak. )21090240 V- Pol . ( Peak. )60210120 H+V. (Peak.)15060120 Frequency = 2450 MHz d BmXY- P l a n eXZ - P l a n eYZ - P l a n e H- Pol . ( Peak. )0. 40764- 0. 699603 - 3. 588694 V- Pol . ( Peak. )- 3. 331827- 5. 890321- 4. 315256 H+V. (Peak.)0. 8644850. 036144- 0. 926499 H- Pol . ( Avg. )- 3. 601958- 4. 81098- 8. 781966 V- Pol . ( Avg. )- 7. 389187- 10. 593998- 8. 767373 H+V. ( Avg. )- 2. 084898- 3. 793313- 5. 764364 AngleXY- P l a n eXZ - P l a n eYZ - P l a n e H- Pol . ( Peak. )24090120 V- Pol . ( Peak. )60120120 H+V. (Peak.)24090120 Frequency = 2500 MHz d BmXY- Pl aneXZ- Pl aneYZ- Pl ane H- Pol . ( Peak. )0. 899152- 0. 849051 - 5. 443866 V- Pol . ( Peak. )- 3. 294259- 6. 126252- 0. 737176 H+V. (Peak.)1. 051473- 0. 048972- 0. 013941 H- Pol . ( Avg. )- 3. 342121- 4. 686666- 8. 809909 V-Pol. (Avg.)- 6. 92073- 10. 702135- 7. 421952 H+V. ( Avg. )- 1. 762506- 3. 71654- 5. 050418 AngleXY- Pl aneXZ- Pl aneYZ- Pl ane H- Pol . ( Peak. )24090 120 V- Pol . ( Peak. )270150210 H+V. (Peak.)24090210
Report Number: 68.910.24.0034.01 EMC_SZ_FR_82 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 66 FCC - TEST REPORT Report Number : 68.910.24.0034.01 Date of Issue: 2024-07-26 Model : X380, X380W, X380S, X381, X381S, X382, X382S, G9, V9, G9 Pro, V9 Pro, V9 Plus Product Type : Robotic Vacuum Cleaner Applicant : Zhiyi (Zhongshan) Technology Co., Ltd. Address : No. 39, Donghui Road, Cuiheng New District, 528400 Zhongshan, Guangdong, PEOPLE’S REPUBLIC OF CHINA Manufacturer : Zhiyi (Zhongshan) Technology Co., Ltd. Address : No. 39, Donghui Road, Cuiheng New District, 528400 Zhongshan, Guangdong, PEOPLE’S REPUBLIC OF CHINA Test Result : ◼ Positive Negative Total pages including Appendices : 66 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation chapter A-3.4. Report Number: 68.910.24.0034.01 EMC_SZ_FR_82 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 66 1 Table of Contents 1 Table of Contents .................................................................................................................. 2 2 Details about the Test Laboratory .......................................................................................... 3 3 Description of the Equipment under Test ............................................................................... 4 4 Summary of Test Standards .................................................................................................. 5 5 Summary of Test Results....................................................................................................... 6 6 General Remarks ................................................................................................................... 7 7 Test Setups ............................................................................................................................ 8 7.1 Radiated Test Setups ..................................................................................................... 8 7.2 Conducted RF Test Setups ............................................................................................ 9 7.3 AC Power Line Conducted Emission Test Setups .......................................................... 9 8 Systems Test Configuration ................................................................................................. 10 9 Technical Requirement ........................................................................................................ 11 9.1 Conducted Emission ..................................................................................................... 11 9.2 Conducted Output Power ............................................................................................. 18 9.3 6dB Bandwidth ............................................................................................................. 19 9.4 Power Spectral Density ................................................................................................ 26 9.5 Spurious RF Conducted Emissions .............................................................................. 33 9.6 Band Edge .................................................................................................................... 46 9.7 Spurious Radiated Emissions for Transmitter ............................................................... 51 10 Test Equipment List ......................................................................................................... 64 11 System Measurement Uncertainty ................................................................................... 66 Report Number: 68.910.24.0034.01 EMC_SZ_FR_82 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 66 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 FCC Registration No.: 514049 FCC Designation Number: CN5009 Report Number: 68.910.24.0034.01 EMC_SZ_FR_82 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 66 3 Description of the Equipment under Test Product: Robotic Vacuum Cleaner Model no.: X380, X380W, X380S, X381, X381S, X382, X382S, G9, V9, G9 Pro, V9 Pro, V9 Plus FCC ID: 2BD8J-X380 Ratings: For X380, X380W, X381, X382, G9 and V9: 19V, 0.6A (for robotic vacuum cleaner); 100-240V, 50/60Hz, 0.35A (for AC adapter) For X380S, X381S, X382S, G9 Pro, V9 Pro and V9 Plus: 19V, 0.6A (for robotic vacuum cleaner); 120VAC, 60Hz, 550W (for Dust collector station) Battery: 14.4Vdc, 2550mAh Accessories: Dust collector station & Docking station & AC adapter RF Transmission Frequency: 2412MHz-2462MHz for 802.11b/g/n20; 2422MHz-2452MHz for 802.11n40 No. of Operated Channel: 11 for…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.42 GHz - 2.45 GHz | 63.10 mW |
Robotic Vacuum Cleaner
Equipment Class
DTS - Digital Transmission SystemRobot Vacuum Cleaner with 2.4GHz Wi-Fi
Equipment Class
DTS - Digital Transmission System