FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Guangdong Fenergy Technology Co., Ltd/
  3. 2BDF9-AT1705

2BDF9-AT170555W Wireless Charging Station

Guangdong Fenergy Technology Co., Ltd
55W Wireless Charging Station - FCC ID 2BDF9-AT1705 - Guangdong Fenergy Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Dec 21, 2023
Application Purpose
Original Equipment
Date of Application
Dec 21, 2023
Equipment Note
55W Wireless Charging Station
Frequency Range
0.11000000 - 0.20500000
Company
Guangdong Fenergy Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

55W Wireless Charging Station 55W Wireless Chargeing Station Model 55W Wireless Chargeing Station AT1705 Specifications 55 Wireless Chargeing Station This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Radiation Exposure Statement The FCC certification of this device refers to RF exposure testing performed in typical operating conditions, where a person is no closer than 20 centimeters from the device surface at all times, except for non-repetitive patterns with transient time intervals in the order of a second. Only in the stated conditions, the device is shown to fully comply with the FCC RF Exposure requirements of KDB 447498.

Attestation Statements

Guangdong Fenergy Technology Co., Ltd Bui!中ng35, Zone 5, Huaide Cuigang Industrial Park, Fuyong Street, Bao'an District, Shenzhen Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7 435 Oakland Mills Road Columbia, MD 21046 2023/12/08 U S Aqent Des,qnatlon Guangoong Fene「gy Technolog,J Co., Ltd acknowledges their consent to「the foll叨ing contact located in the United States to act as thei「agentto「service of process to「the equipment to「whichauthorization is sought (FCC ID: 2BDF9-AT1705) Name and company of U. S. agent: Physical U.S. add「ess of agent: FRN of U.S. agent: Email adctess of U.S. agent: Atomi Inc 10West33 St- Suite 520New York, NY 10001, New York. Un ite d States 0032288656 [email protected] Atomi Inc acknoWle句esthei「obligationto accept service of p「ocesson behalf of Guangoong Fene「gy Technology Co., Ltd Guangdong Fene屯yTechnolog,J Co . , Ltd with the FRN [0034437087] accepts its obligation to maintain an agent to「serviceof process in the United States to「no less than one yea「afte「eithe「the grantee has permanently terminated all ma「Ketingand importation of the applicable equipment within the U.S., o「the conclusion of any Commission-related administrati v e o「jucicialproceeding involving the e中ipment, whichever is late「 By signing this form, we confi「m the above and that we a「e awa「e of the application re中1「ementslisted un知§ 2 .911 (d)[l) The information p「ovidedin this letter is based on the refe「encedrule parts of Tit l e 47 of the CFR as wen as KDB 986446 D01 �� ;;;: i :� i :;: ��;: i . st. In case the U.S. agent changes, the grantee is obligated to notify S OA ' n 'CX P)二6 · i 1uo11v snli•puuj 8P Since 飞 l y, 1沁队i Signatu「e Iris Wei Certified enginee「 Guangdong Fene「gy Technolog,J Co., Ltd N o- nc 1j WonJ Signatu「e Nancywa n g Manage「 Atomi Inc

External Photos

Shenzhen BANTEK Testing Co., Ltd. Page 1 of 5 Report No.: BTEK231020009AE001 Appendix EUT Photos for BTEK231020009AE001 Shenzhen BANTEK Testing Co., Ltd. Page 2 of 5 Report No.: BTEK231020009AE001 External Shenzhen BANTEK Testing Co., Ltd. Page 3 of 5 Report No.: BTEK231020009AE001 Shenzhen BANTEK Testing Co., Ltd. Page 4 of 5 Report No.: BTEK231020009AE001 Shenzhen BANTEK Testing Co., Ltd. Page 5 of 5 Report No.: BTEK231020009AE001

Internal Photos

Shenzhen BANTEK Testing Co., Ltd. Page 1 of 7 Report No.: BTEK231020009AE001 Appendix EUT Photos for BTEK231020009AE001 Shenzhen BANTEK Testing Co., Ltd. Page 2 of 7 Report No.: BTEK231020009AE001 Internal Shenzhen BANTEK Testing Co., Ltd. Page 3 of 7 Report No.: BTEK231020009AE001 Shenzhen BANTEK Testing Co., Ltd. Page 4 of 7 Report No.: BTEK231020009AE001 Shenzhen BANTEK Testing Co., Ltd. Page 5 of 7 Report No.: BTEK231020009AE001 Shenzhen BANTEK Testing Co., Ltd. Page 6 of 7 Report No.: BTEK231020009AE001 Shenzhen BANTEK Testing Co., Ltd. Page 7 of 7 Report No.: BTEK231020009AE001

RF Exposure Info

Shenzhen BANTEK Testing Co., Ltd. Page 1 of 12 Report No.: BTEK231020009AE002 RF Exposure Report For Applicant Name: Guangdong Fenergy Technology Co., Ltd Address: Building 35, Zone 5, Huaide Cuigang Industrial Park, Fuyong Street, Bao 'an District, Shenzhen EUT Name: 55W Wireless Charging Station Brand Name: atomi Model Number: AT1705 Issued By Company Name: Shenzhen BANTEK Testing Co., Ltd. Address: A5&A6,Building B1&B2,No.45 Gangtou Road,BoganCommunity, Shajing Street,Bao'an District, Shenzhen,Guangdong,China 518104 Report Number: BTEK231020009AE002 Test Standards: 47 CFR PART 1, Subpart I, Section 1.1310 47 CFR PART 2, Subpart J, Section 2.1091 FCC ID: 2BDF9-AT1705 Test Conclusion: Pass Test Date: 2023-11-16 to 2023-12-05 Date of Issue: 2023-12-05 Prepared By: Elma Yang /Project Engineer Date: 2023-12-05 Approved By: Damon Su / EMC Manager Date: 2023-12-05 * In the configuration tested, the EUT complied with the standards specified above. Shenzhen BANTEK Testing Co., Ltd. Page 2 of 12 Report No.: BTEK231020009AE002 Revision History Version Issue Date Revisions Content R_V0 2023-12-05 Original Note: Once the revision has been made, then previous versions reports are invalid. Shenzhen BANTEK Testing Co., Ltd. Page 3 of 12 Report No.: BTEK231020009AE002 Table of Contents 1. Introduction............................................................................................................................................................................................ 4 1.1 Identification of Testing Laboratory ................................................................................................................................. 4 1.2 Identification of the Responsible Testing Location ...................................................................................................... 4 1.3 Laboratory Condition ........................................................................................................................................................... 4 1.4 Announcement ....................................................................................................................................................................... 4 2. Product Information .............................................................................................................................................................................. 5 2.1 Application Information ....................................................................................................................................................... 5 2.2 Manufacturer Information .................................................................................................................................................... 5 2.3 Factory Information .............................................................................................................................................................. 5 2.4 General Description of Equipment under Test (EUT)................................................................................................... 5 2.5 Technical Information........................................................................................................................................................... 5 3. Test Requirement ................................................................................................................................................................................. 6 1.1 Assessment Result ............................................................................................................................................................... 8 1.1 Test Set-up Photo .................................................................................................................................................................. 9 Shenzhen BANTEK Testing Co., Ltd. Page 4 of 12 Report No.: BTEK231020009AE002 1. Introduction 1.1 Identification of Testing Laboratory Company Name: Shenzhen BANTEK Testing Co., Ltd. Address: A5&A6,Building B1&B2,No.45 Gangtou Road,BoganCommunity, Shajing Street,Bao'an District, Shenzhen,Guangdong,China 518104 Phone Number: +86(755) 2334 4200 Fax Number: +86(755) 2334 4200 1.2 Identification of the Responsible Testing Location Test Location: Shenzhen BANTEK Testing Co., Ltd. Address: A5&A6,Building B1&B2,No.45 Gangtou Road,BoganCommunity, Shajing Street,Bao'an District, Shenzhen,Guangdong,China 518104 Description: All measurement facilities used to collect the measurement data are located at A5&A6,Building B1&B2,No.45 Gangtou Road,BoganCommunity, Shajing Street,Bao'an District, Shenzhen,Guangdong,China 518104 FCC Registration Number: 264293 Designation Number: CN1356 1.3 Laboratory Condition Ambient Temperature: 20°C to 25°C Ambient Relative Humidity: 45% to 55% Ambient Pressure: 100 kPa to 102 kPa 1.4 Announcement (1) The test report is invalid if not marked with the signatures of the persons responsible for preparing, reviewing and approving the test report. (2) This document may not be altered or revised in any way unless done so by BANTEK and all revisions are duly noted in the revisions section. (3) Content of the test report, in part or in full, cannot be used for publicity and/or promotional purposes without prior written approval from the laboratory. (4) The laboratory is only responsible for the data released by the laboratory, except for the part provided by the applicant. Shenzhen BANTEK Testing Co., Ltd. Page 5 of 12 Report No.: BTEK231020009AE002 2. Product Information 2.1 Application Information Company Name: Guangdong Fenergy Technology Co., Ltd Address: Building 35, Zone 5, Huaide Cuigang Industrial Park, Fuyong Street, Bao 'an District, Shenzhen 2.2 Manufacturer Information Company Name: Guangdong Fenergy Technology Co., Ltd Address: Building 35, Zone 5, Huaide Cuigang Industrial Park, Fuyong Street, Bao 'an District, Shenzhen 2.3 Factory Information Company Name: Guangdong Fenergy Techno…

Text truncated - open the document above for the full version.

Test Report

廣州市億華富電子有限公司 承認書 SpecificationForApproval 客戶(Customer):明新能 名稱(Name):两線圈S7A-15W 產品規格:0.08*105P9TS絲包線 (ProductSpecification) 日期(Date):2023.11.07 ApprovedIssue ZHENGYIHUALiuMin 客戶判定(CustomerJudgment): □承認Approved□不合格Rejected□條件認可ConditionalApproval 客戶承認CustomerApprovedBy 地址/Address 广州市增城区小楼镇腊圃村下元街十二巷20号 TEL:18825718180 產品規格承認書 SPECIFICATION FOR APPROVAL ■產品形狀和尺寸Product Apperance & Dimensions 产品具体图片所示 注 : 兩個線圈近頂端 ■產品電氣特性Product Electrical characteristics 參數(Parameter)數值(Value) 電感(Inductance) :7.0 μH ± 0.5 Q值(Q Value) :80 ± 1% (Min.) 直流電阻(DC Resistance) :0.039 ± 5% Ω 測試儀器(Testing Instrument) :LCR-106X @100kHz, 1Vrms;TH2512B At 25°C 线圈距磁片边缘1-1.5MM 两中心距离35±1MM 线圈距磁片边缘1-1.5MM 天线增益 (Gain) : 0dBi

Test Report

Shenzhen BANTEK Testing Co., Ltd. Page 1 of 27 Report No.: BTEK231020009AE001 Test Report Applicant Name: Guangdong Fenergy Technology Co., Ltd Address: Building 35, Zone 5, Huaide Cuigang Industrial Park, Fuyong Street, Bao 'an District, Shenzhen EUT Name: 55W Wireless Charging Station Brand Name: atomi Model Number: AT1705 Issued By Company Name: Shenzhen BANTEK Testing Co., Ltd. Address: A5&A6,Building B1&B2,No.45 Gangtou Road,BoganCommunity, Shajing Street,Bao'an District, Shenzhen,Guangdong,China 518104 Report Number: BTEK231020009AE001 Test Standards: 47 CFR Part 15 Subpart C FCC ID: 2BDF9-AT1705 Test Conclusion: Pass Test Date: 2023-11-16 to 2023-12-05 Date of Issue: 2023-12-05 Prepared By: Elma Yang /Project Engineer Date: 2023-12-05 Approved By: Damon Su / EMC Manager Date: 2023-12-05 * In the configuration tested, the EUT complied with the standards specified above. Shenzhen BANTEK Testing Co., Ltd. Page 2 of 27 Report No.: BTEK231020009AE001 Revision History Version Issue Date Revisions Content R_V0 2023-12-05 Original Note: Once the revision has been made, then previous versions reports are invalid. Shenzhen BANTEK Testing Co., Ltd. Page 3 of 27 Report No.: BTEK231020009AE001 Table of Contents 1. Introduction............................................................................................................................................................................................ 4 1.1 Identification of Testing Laboratory ................................................................................................................................. 4 1.2 Identification of the Responsible Testing Location ...................................................................................................... 4 1.3 Laboratory Condition ........................................................................................................................................................... 4 1.4 Announcement ....................................................................................................................................................................... 4 2. Product Information .............................................................................................................................................................................. 5 2.1 Application Information ....................................................................................................................................................... 5 2.2 Manufacturer Information .................................................................................................................................................... 5 2.3 Factory Information .............................................................................................................................................................. 5 2.4 General Description of Equipment under Test (EUT)................................................................................................... 5 2.5 Technical Information........................................................................................................................................................... 5 3. Summary of Test Results .................................................................................................................................................................... 7 3.1 Test Standards ....................................................................................................................................................................... 7 3.2 Summary of Test Result ...................................................................................................................................................... 7 3.3 Uncertainty of Test ................................................................................................................................................................ 8 4. Test Configuration ................................................................................................................................................................................ 9 4.1 Environment Condition ........................................................................................................................................................ 9 4.2 Test Equipment List .............................................................................................................................................................. 9 4.3 Test Auxiliary Equipment .................................................................................................................................................. 10 4.4 Test Setup ............................................................................................................................................................................. 11 5. Test Items ............................................................................................................................................................................................ 13 5.1 Antenna Requirements ...................................................................................................................................................... 13 5.2 20dB Occupied Bandwidth ............................................................................................................................................... 14 5.3 AC Power Line Conducted Emissions ........................................................................................................................... 15 5.4 Radiated Spurious Emission ............................................................................................................................................ 16 ANNEX A Test Results ............................................................................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen BANTEK Testing Co., Ltd. Page 1 of 3 Report No.: BTEK231020009AE001 Appendix Setup Photos for BTEK231020009AE001 Shenzhen BANTEK Testing Co., Ltd. Page 2 of 3 Report No.: BTEK231020009AE001 Radiated Emissions(Above 30MHz) Radiated Emissions(Below 30MHz) Shenzhen BANTEK Testing Co., Ltd. Page 3 of 3 Report No.: BTEK231020009AE001 Power Line Conducted Emissions

Contact Information

Applicant

Iris Wei
[email protected]13476117818Fax: 13476117818

Test Firm

Shenzhen BANTEK Testing Co., Ltd.Taylor Wu
[email protected]+86 0755-23344200

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term
Grant Notes
The FCC certification of this device refers to RF exposure testing performed in typical operating conditions, where a person is no closer than 20 centimeters from the device surface at all times, except for non-repetitive patterns with transient time intervals in the order of a second. Only in the stated conditions, the device is shown to fully comply with the FCC RF Exposure requirements of KDB 447498.