Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Section Company n Address: 11 Xiangjiaota Product Na FCCID: 2B Model(s): P 2.911(d)(5 ) We, [Shen z which autho Pro Ide n Yours sinc e Name: pete Title: man a Company n Signature: NOTE 1 “Covered List https://www.f c References; 1) 986446 D 0 https://apps.fc 2) Federal R e https://www.fe munications-s Sh 2.911(d) name: Shen 10, Building ang Commu ame: Magne DK8-PC25H PC25HL01, )(i) Equipm zhen Microg orization is hibited fro m ntified as an erely, er cheng ager name: Shen ”; is the List o cc.gov/supplyc 01 Covered Eq cc.gov/oetcf/kd egister docume ederalregister. supply-chain-t henzhen )(5)(i) Ce nzhen Micro g A1, Yuanc unity, Bantia etic Charger HL01 PC25HL01 mentType gravity Tech sought thro m receiving n equipmen nzhen Micro of Equipment a chain/covered quipment v01 db/forms/FTS ent 2022-2826 gov/documen hrough-the Microg ertificatio ogravity Tec chuang Spa an Street, Sh r A, PC25H L hnology Co. ough certific an equipme nt type in the ogravity Tec and Services C list SearchResul t 63 published o nts/2023/02/06 ravity Te on – Equi chnology Co ce Xuexian henzhen, C L01B, PC25 ., Ltd] (“the cation is not ent authoriz e “Covered chnology Co Covered By S tPage.cfm?sw on 02/06/23 6/2022-28263/ echnolog 2. ipmentTy o., Ltd g Garden, N China 5HL01C applicant”) t: zation pursu List” NOTE 1 o., Ltd ection 2 of Th witch=P&id=32 /protecting-ag gy Co., 911 (d)(5)(i) Eq ype No. 33, Zho certify that uant to § 2.9 D e Secure Netw 5672 ainst-national - Ltd quipment Type A onghao 2nd the equipm 903; of the F Date: Nov. 1 works Act, ava -security-threa Attestation v1.2 d Road, ment for FCC rules. 14, 2023 ailable at ats-to-the-com 2 m
Section Company n Address: 11 Xiangjiaota Product Na FCCID: 2B Model(s): P 2.911(d)(5 ) We, [Shenz filing of the pursuant t o Yours sinc e Name: pet e Title: man a Company n Signature: NOTE 1 Delete option NOTE 2 “Covered List https://www.f c References; 1) 986446 D 0 https://apps.fc 2) Federal R e https://www.fe munications-s Sh 2.911(d) name: Shen 10, Building ang Commu ame: Magne DK8-PC25H PC25HL01, )(ii) Applica zhen Microg application o §1.50002 erely, er cheng ager name: Shen not applicable ”; is the List o cc.gov/supplyc 01 Covered Eq cc.gov/oetcf/kd egister docume ederalregister. supply-chain-t henzhen )(5)(ii) Ce nzhen Micro g A1, Yuanc unity, Bantia etic Charger HL01 PC25HL01 ant filing gravity Tech n, the applic of this chap nzhen Micro e to this applic of Equipment a chain/covered quipment v01 db/forms/FTS ent 2022-2826 gov/documen hrough-the Microg ertificatio ogravity Tec chuang Spa an Street, Sh r A, PC25H L hnology Co. cant is not i pter, as an e ogravity Tec cation. and Services C list SearchResul t 63 published o nts/2023/02/06 ravity Te on – App chnology Co ce Xuexian henzhen, C L01B, PC25 ., Ltd] (“the identified NO entity produ chnology Co Covered By S tPage.cfm?sw on 02/06/23 6/2022-28263/ echnolog plicant (C o., Ltd g Garden, N China 5HL01C applicant”) OTE 1 on the “ cing covere o., Ltd ection 2 of Th witch=P&id=32 /protecting-ag gy Co., 2.911 (d)(5 Covered L No. 33, Zho certify that, “Covered Li ed commun Dat e e Secure Netw 5672 ainst-national - Ltd 5)(ii) Applicant A List ) onghao 2nd , as of the d ist” NOTE 2 , es ications eq e: Nov. 14, works Act, ava -security-threa Attestation v1.3 d Road, date of the stablished uipment. 2023 ailable at ats-to-the-com 3 m
Co m Ad d 2nd Pr o Mo d Pr o We act We an d issu our Sig Na m Title Com S mpany: Sh dress: 110 d Road, Xia oduct Name del Numbe oduct Desc authorize M on our beha declare tha d certificatio ues concern behalf shal nature: me: e: mpany: Shenzhe enzhen Mic 0, Building angjiaotang e: Magnetic er(s): PC25H ription: Ma MiCOM Lab alf on all ma at MiCOM L n of equipm ning the app ll have the s peter che manager Shenzhen en Micro Agen crogravity A1, Yuanc g Commun c Charger HL01, PC2 agnetic Cha bs Inc., 575 atters conce Labs Inc. is ment to the r proval applic same effect ng n Micrograv ogravity nt Auth Technolog huang Spa ity, Bantian 5HL01A, P arger Boulder C o erning the c allowed to f regulatory a cation. Any t as acts of vity Techno y Techn horizat gy Co., Ltd ace Xuexian n Street, S C25HL01 B ourt, Pleasa certification forward all i agencies as and all acts our own. ology Co., ology C tion ng Garden henzhen, C B, PC25HL0 anton, Califo of above na information s required a s carried ou Date: Ltd Co., Ltd , No. 33, Zh China 01C ornia 94566 amed equip related to t nd to discu ut by MiCOM Nov. 14, 20 honghao 6, USA, to pment. the approva ss any M Labs on 023 al
Office o Federa 7435 O Columb USA Subjec t FCC ID To Wh o Pursua are req u docume These d propriet might b In addi t in Title busine s authoriz For 4 O For 1 It is ou r corresp docume authoriz Sincer e Signatu Name: Title: m S of Engineeri l Communic Oakland Mills bia, MD 210 t; Request f D: 2BDK8-P om It May C nt to the pro uesting the ents from pu documents tary informa be harmful to Schemat Block Di Parts Lis Operatio Tune-up tional to abo 47 CFR §2 ss sensitive zed devices External Test Set Internal P User Ma 45 days, pu OR 180 days pu r understand pondence du ents and thi zation is iss ely, ure: peter chen g anager henzhe ing Techno cations Com s Road 046 for Confiden PC25HL01 Concern, ovisions of t Commissio ublic disclos contain det ation in ope o our comp tic Diagram agram st onal Descrip Procedure ove mention .803 and th informatio n s, we reque Photos tup Photos Photos anual rsuant to P u ursuantto KD ding that all uring the ce s informatio sued. g n Microg logy mmission ntiality the Commis on to withho sure indefin tailed syste ration of th e any and wo m ption ned docume e importatio n remains c st Short Te ublic Notice DB 726920 l measurem ertification re on will be av gravity T ssion’s rule old the follow nitely. m and equi e equipmen ould give co ents, in orde on rules in T confidential rm Confide e DA 04-170 0 D01. ment test rep eview proce vailable for Technolo s Title 47 S wing attach pment desc nt. The publ ompetitors a er to comply Title 47 CFR until the act ntiality of th 05. ports, FCC ess cannot public revi e ogy Co. Sections §0. hment(s) as criptions an ic disclosu r an unfair ad y with the m R §2.1204, tual market he following ID label for be granted ew once the , Ltd Date: Nov. 457 and § 0 confidentia d are consi re of these d vantage in marketing re while ensu ting of newly attachmen mat and as confide n e grant of eq 14, 2023 0.459, we al dered as documents the market . egulations ring that y t(s); ntial quipment .
To W We, Mo d softw Test Ple a Sig Na m Title S Whom It May Shenzhen M del Number: ware and ele t sample mo ase contact m nature: me: p e: m henzhe Mo y Concern, Microgravity PC25HL01, ectric circuit a del: PC25HL me if you hav peter cheng manager en Micro odel Di Technology PC25HL01 A are the same L01. ve any quest g ogravity fferenc Co., Ltd (Ma A, PC25HL01 e, only with p tion. y Techn ce Dec agnetic Charg 1B, PC25HL0 product mode nology C claratio ger); Trade 01C; All mod el named diff Date: Co., Ltd on Mark: HALO del’s the func ferent. Nov. 14, 2 O BLK; ction, 023
Annex A External Photos Report No.: HK2311035216-1E/2E Page 1 of 3 Report No.: HK2311035216-1E/2E Page 2 of 3 Report No.: HK2311035216-1E/2E Page 3 of 3
FCC ID LABEL: Ca. 30mm x 10mm Label Location FCC ID: 2BDK8-PC25HL01
Annex B Internal Photos Report No.: HK2311035216-1E/2E Page 1 of 4 Antenna Report No.: HK2311035216-1E/2E Page 2 of 4 Report No.: HK2311035216-1E/2E Page 3 of 4 Report No.: HK2311035216-1E/2E Page 4 of 4
Page 1 of 11 Report No.: HK2311035216-2E FCC Test Report Test Report On Behalf of Shenzhen Microgravity Technology Co., Ltd For Magnetic Charger Model No.: PC25HL01, PC25HL01A, PC25HL01B, PC25HL01C FCC ID: 2BDK8-PC25HL01 Prepared For: Shenzhen Microgravity Technology Co., Ltd 110, Building A1, Yuanchuang Space Xuexiang Garden, No. 33, Zhonghao 2nd Road, Xiangjiaotang Community, Bantian Street, Shenzhen, China Prepared By: Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Nov. 03, 2023 ~ Nov. 13, 2023 Date of Report: Nov. 13, 2023 Report Number: HK2311035216-2E Page 2 of 11 Report No.: HK2311035216-2E Test Result Certification Applicant’s Name ................. : Shenzhen Microgravity Technology Co., Ltd Address.................................. : 110, Building A1, Yuanchuang Space Xuexiang Garden, No. 33, Zhonghao 2nd Road, Xiangjiaotang Community, Bantian Street, Shenzhen, China Manufacture's Name ............ : Shenzhenyiqizhao Technology Co.,Ltd Address.................................. : 201, Floor 2, Building 6, Yunli Intelligent Park, No. 3, Changfa Middle Road, Yangmei Community, Bantian Street, Shenzhen, Guangdong, China Product Description Trade Mark ................................ : HALO BLK Product Name ........................... : Magnetic Charger Model and/or Type Reference: PC25HL01, PC25HL01A, PC25HL01B, PC25HL01C Standards ............................. : FCC CFR 47 PART 18, KDB 680106 D01 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of Performance of Tests ............ : Nov. 03, 2023 ~ Nov. 13, 2023 Date of Issue ........................................... : Nov. 13, 2023 Test Result ............................................... : Pass Testing Engineer : (Gary Qian) Technical Manager : (Eden Hu) Authorized Signatory : (Jason Zhou) Page 3 of 11 Report No.: HK2311035216-2E Note: 1. For a more de tailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2. Frequency Band: 112-205KHz Channel List Channel Frequency (KHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 01 140 The EUT antenna is Coil Antenna. No antenna other than that furnished by the responsible party shall be used with the device. 2. Summary of Test Results 2.1 Test procedures according to the technical standards: FCC KDB 680106 D01 RF Exposure Wireless Charging Apps v03r01 FCC CFR 47 Standard Section Test Item Judgment Remark FCC CFR 47 part1, 1.1310 KDB 680106 D01v03r01 (3)(3) Magnetic Field Strength (H) (A/m) PASS 2.2 Measurement Uncertainty The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 All Emissions, Radiated(<30M)(9KHz-30MHz) ±3.90dB 2 Temperature ±0.5°C 3 Humidity ±2% Page 4 of 11 Report No.: HK2311035216-2E 2.3 Test Instruments Description Brand Model No. S/N Calibrated Date Calibrated Until Electric and Magnetic Field Analyzer narda EHP-200AC180ZX11028 Feb. 17, 2023 Feb. 16, 2024 NOTE: 1. The calibration interval of the above test instruments is 12 months. 2.4 Test Mode Test Item Te s t mode Description MPE Test Cases Mode 1AC/DC Adapter+ EUT + Mobile Phone (Battery Status: <1%) Mode 2AC/DC Adapter+ EUT + Mobile Phone (Battery Status: <50%) Mode 3AC/DC Adapter+ EUT + Mobile Phone (Battery Status: >95%) Note: 1. All modes and configurations above have been tested, Only the result of the worst case was recorded in the report, the worst-case configuration is Mode 1. 2. For Radiated Emission, 3axis were chosen for testing for each applicable mode. 3. The Mobile Phone provided by Lab. 4. According to the manufacturer's design principle, the wireless charging power will reach its maximum when the client device's battery level is between 1% and 10%. Page 5 of 11 Report No.: HK2311035216-2E 3. Maximum Permissible Exposure Limit of Maximum Permissible Exposure Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180 / f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1 30 Note 1: f = frequency in MHz; *Plane-wave equivalent power density. Note 2: For the applicable limit, see FCC 1.1310, 680106 D01 RF Exposure Wireless Charging Apps v03. Note 3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. Page 6 of 11 Report No.: HK2311035216-2E 4. Test Procedure a. For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of (H-field & E- field strengths for all sides is 15cm, H-field strengths of top side is 20cm). E and H field strength measurements or numerical modeling may be used to d…
Text truncated - open the document above for the full version.
Page 1 of 22 Report No.: HK2311035216-1E FCC Test Report Test Report On Behalf of Shenzhen Microgravity Technology Co., Ltd For Magnetic Charger Model No.: PC25HL01, PC25HL01A, PC25HL01B, PC25HL01C FCC ID: 2BDK8-PC25HL01 Prepared For: Shenzhen Microgravity Technology Co., Ltd 110, Building A1, Yuanchuang Space Xuexiang Garden, No. 33, Zhonghao 2nd Road, Xiangjiaotang Community, Bantian Street, Shenzhen, China Prepared By: Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Nov. 03, 2023 ~ Nov. 13, 2023 Date of Report: Nov. 13, 2023 Report Number: HK2311035216-1E Page 2 of 22 Report No.: HK2311035216-1E Test Result Certification Applicant’s Name ................. : Shenzhen Microgravity Technology Co., Ltd Address.................................. : 110, Building A1, Yuanchuang Space Xuexiang Garden, No. 33, Zhonghao 2nd Road, Xiangjiaotang Community, Bantian Street, Shenzhen, China Manufacture's Name ............ : Shenzhenyiqizhao Technology Co.,Ltd Address.................................. : 201, Floor 2, Building 6, Yunli Intelligent Park, No. 3, Changfa Middle Road, Yangmei Community, Bantian Street, Shenzhen, Guangdong, China Product Description Trade Mark ................................ : HALO BLK Product Name ........................... : Magnetic Charger Model and/or Type Reference: PC25HL01, PC25HL01A, PC25HL01B, PC25HL01C Standards ............................. : FCC CFR 47 PART 18 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of Performance of Tests ............ : Nov. 03, 2023 ~ Nov. 13, 2023 Date of Issue ........................................... : Nov. 13, 2023 Test Result ............................................... : Pass Testing Engineer : (Gary Qian) Technical Manager : (Eden Hu) Authorized Signatory : (Jason Zhou) Page 3 of 22 Report No.: HK2311035216-1E Table of Contents Page 1 . Test Summary 5 1.1 . Test Procedures and Results 5 1.2 . Information of the Test Laboratory 5 1.3 . Measurement Uncertainty 5 2. General Information 6 2.1. General Description of EUT 6 2.2. Carrier Frequency of Channels 7 2.3. Operation of EUT during Testing 7 2.4. Description of Test Setup 8 2.5. Description of Support Units 9 2.6. Measurement Instruments List 10 3. Conducted Emission Test 11 3.1. Block Diagram of Test Setup 11 3.2. Conducted Power Line Emission Limit 11 3.3. Test Procedure 11 3.4. Test Result 12 4. Radiated Emissions 14 4.1. Block Diagram of Test Setup 14 4.2. Rules and Specifications 15 4.3. Test Procedure 15 4.4. Test Result 16 5. Antenna Requirement 19 6. Photographs of Test 20 7. Photos of the EUT 22 Page 4 of 22 Report No.: HK2311035216-1E ** Modified History ** Revision Description Issued Data Remark Revision 1.0 Initial Test Report Release Nov. 13, 2023 Jason Zhou Page 5 of 22 Report No.: HK2311035216-1E 1. Test Summary 1.1. Test Procedures and Results Description of Test Section Number Result Conducted Emissions Test 18.307 COMPLIANT Radiated Emission Test 18.305 COMPLIANT Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. 1.2. Information of the Test Laboratory Shenzhen HUAK Testing Technology Co., Ltd. Add.: 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Testing Laboratory Authorization: A2LA Accreditation Code is 4781.01. FCC Designation Number is CN1229. Canada IC CAB identifier is CN0045. CNAS Registration Number is L9589. 1.3. Measurement Uncertainty Measurement Uncertainty Conducted Emission Expanded Uncertainty =2.71dB, k=2 Radiated emission expanded uncertainty(9kHz-30MHz) = 3.90dB, k=2 Radiated emission expanded uncertainty(30MHz-1000MHz)= 3.90dB, k=2 Radiated emission expanded uncertainty(Above 1GHz) = 4.28dB, k=2 Page 6 of 22 Report No.: HK2311035216-1E 2. General Information 2.1. General Description of EUT Equipment: Magnetic Charger Model Name: PC25HL01 Series Models: PC25HL01A, PC25HL01B, PC25HL01C Model Difference: All model's the function, software and electric circuit are the same, only with product model named different. Test sample model: PC25HL01. Trade Mark: HALO BLK FCC ID: 2BDK8-PC25HL01 Antenna Type: Coil Antenna Antenna Gain: 0dBi Operation Frequency: 112KHz~205KHz Test Frequency: 140KHz Number of Channels: 1 Modulation Type: ASK Power Source: Input: DC5V/2A, 9V/2A, 12V/2A Output: 5W/7.5W/10W/15W (Max) Power Rating: Input: DC5V/2A, 9V/2A, 12V/2A Output: 5W/7.5W/10W/15W (Max) Page 7 of 22 Report No.: HK2311035216-1E 2.2. Carrier Frequency of Channels Operation Frequency each of channel Channel Frequency 01 140KHz 2.3. Operation of EUT during Testing Test Item Test mode Description Radiated & Conducted Test Cases Mode 1 AC/DC Adapter+ EUT +Wireless load (Full Load) Mode 2 AC/DC Adapter+ EUT +Wireless load (Half Load) Mode 3 AC/DC Adapter+ EUT +Wireless load (Null Load) Note: 1. All modes and configurations above have been tested, Only the result of the worst case was recorded in the report, the worst-case configuration is Mode 1. 2. For Radiated Emission, 3axis were chosen for testing for each applicable mode. 3. The wireless load replaces the Mobile Phone by Lab. 4. According to the manufacturer's design principle, the wireless charging power will reach its maximum when the client device's battery level is between 1% an…
Text truncated - open the document above for the full version.
Report No.: HK2311035216-1E/2E Radiated Emission Report No.: HK2311035216-1E/2E Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.112 MHz - 0.205 MHz | - |