Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
:LUHOHVV6FUHHQ0LUURULQJZLWK$QGURLG3KRQHV )URPWKHKRPHVFUHHQWDSĀ0LUDFDVWā :LUHOHVV6FUHHQ0LUURULQJZLWKL3KRQH 8VLQJ)HDWXUHV 8VLQJ)HDWXUHV 7XUQRQ:L)LRQWKHSURMHFWRUVHOHFWĀ6FUHHQ0LUURULQJā2Q\RXUSKRQHDQGWKHQFRQQHFWWRWKHSURMHFWRUE\VHOHFWLQJWKHFRUUHVSRQGLQJĀ'HYLFH1DPHāGLVSOD\HGRQWKHSURMHFWRU )URPWKHKRPHVFUHHQWDSĀ$LU3LQ3URāDŽ&RQQHFWERWKWKHVPDUWSKRQHDQGWKHSURMHFWRUWRWRWKHVDPH:L)LQHWZRUN 7XUQRQWKHĀ6FUHHQ0LUURULQJāIXQFWLRQRQ\RXUSKRQHDQGF RQQHFW WRWKHSURMHFWRU )))))))))) UUUUUU R P W K H K R P H V F U H H Q W D S Ā 0 L U D F D V W ā 3RUWDEOH+'3URMHFWRU_8VHU0DQXDO 3RUWDEOH+'3URMHFWRU_8VHU0DQXDO 3RUWDEOH+'3URMHFWRU_8VHU0DQXDO 3RUWDEOH+'3URMHFWRU_8VHU0DQXDO 3RUWDEOH+'3URMHFWRU_8VHU0DQXDO FCC Warnning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: ЬReorient or relocate the receiving antenna. ЬIncrease the separation between the equipment and receiver. ЬConnect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
Shenzhen Huaying Communication Co., LTD 4/F, Building 5, Saitu Digital Industrial Factory, No. 137, Bulan Road, Jihua Street, Longgang District, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024/09/02 U.S. Agent Designation Shenzhen Huaying Communication Co., LTD acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BDN3-HY6): Name and company of U.S. agent: GSS SERVICE INC Physical U.S. address of agent: 6547 N Academy Blvd #2266 Colorado Springs COLORADO 80918 United States FRN of U.S. agent: 0033402082 Email address of U.S. agent: [email protected] GSS SERVICE INC acknowledges their obligation to accept service of process on behalf of Shenzhen Huaying Communication Co., LTD Shenzhen Huaying Communication Co., LTD with the FRN [0034509794] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Kevin Chen Manager Shenzhen Huaying Communication Co., LTD Signature Michoux Logan PM GSS SERVICE INC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5
Shenzhen Huaying Communication Co., LTD 4/F, Building 5, Saitu Digital Industrial Factory, No. 137, Bulan Road, Jihua Street,Longgang District, Shenzhen,China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-9-5 To whom it may concern: We, Shenzhen Huaying Communication Co., LTD, hereby certify that the equipment for which authorization is sought (FCC ID: 2BDN3-HY6) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Kevin Chen Manager Shenzhen Huaying Communication Co., LTD 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V03
Shenzhen Huaying Communication Co., LTD Add: 4/F, Building 5, Saitu Digital Industrial Factory, No. 137, Bulan Road, Jihua Street,Longgang District, Shenzhen,China Date: 2024-9-5 FCC ID: 2BDN3-HY6 Dear Sir/Madam, We, Shenzhen Huaying Communication Co., LTD Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: Projector Model no.: HY6, HY7, HY8, HY9, HY10, HY11, HY12, HY13, HY15, HY16, HY17, HY18,HY19, HY20 Sincerely, Name/Title: Kevin Chen/Manager Company: Shenzhen Huaying Communication Co., LTD Address: 4/F, Building 5, Saitu Digital Industrial Factory, No. 137, Bulan Road, Jihua Street,Longgang District, Shenzhen,China Phone: 8618565882979 Fax: N/A E-Mail: [email protected]
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2024-9-5> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2BDN3-HY6 HY6 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Kevin Chen/Manager Company: Shenzhen Huaying Communication Co., LTD Address: 4/F, Building 5, Saitu Digital Industrial Factory, No. 137, Bulan Road, Jihua Street,Longgang District, Shenzhen,China Phone: 8618565882979 Fax: N/A E-Mail: [email protected]
Shenzhen Huaying Communication Co., LTD 4/F, Building 5, Saitu Digital Industrial Factory, No. 137, Bulan Road, Jihua Street,Longgang District, Shenzhen,China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-9-5 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2BDN3-HY6 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Kevin Chen/Manager Company: Shenzhen Huaying Communication Co., LTD Address: 4/F, Building 5, Saitu Digital Industrial Factory, No. 137, Bulan Road, Jihua Street,Longgang District, Shenzhen,China Phone: 8618565882979 Fax: N/A E-Mail: [email protected]
FCC ID: 2BDN3-HY6 External Photos of the EUT FCC ID: 2BDN3-HY6 FCC ID: 2BDN3-HY6
Label and Location Size: L: 2.0cm*W: 1.0cm Label and Location FCC ID : 2BDN3-HY6
FCC ID: 2BDN3-HY6 Internal Photos of the EUT FCC ID: 2BDN3-HY6 FCC ID: 2BDN3-HY6 FCC ID: 2BDN3-HY6 FCC ID: 2BDN3-HY6 WIFI ANT FCC ID: 2BDN3-HY6 FCC ID: 2BDN3-HY6 BT ANT FCC ID: 2BDN3-HY6 FCC ID: 2BDN3-HY6
RF Exposure evaluation FCC ID: 2BDN3-HY6 Exposure category: General population/uncontrolled environment EUT Type: Production Unit Device Type: Mobile Device 1. Reference According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1091 RF exposure is calculated. KDB447498 D01: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies 2. Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 3. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 4. Antenna Information HY6 can only use antennas certificated as follows provided by manufacturer; Antenna No. Model No. of antenna: Type of antenna: Gain of the antenna (Max.) Frequency range: BT / PCB antenna 1.08 dBi for 2400-2500MHz; 2.4GWIFI Internal antenna 0.85 dBi for 2400-2500MHz; 5.2GWIFI / Internal antenna 1.12dBi for 5180-5240MHz 5.8GWIFI / Internal antenna 1.28dBi for 5745-5825MHz 5. Manufacturing Tolerance Mode Max. Peak Conducted Output Power (dBm) Max. tune-up BT 2.18 2.0±1 BLE -1.27 -1.0±1 2.4GWIFI 14.98 15.0±1 Mode Max. Average Conducted Output Power (dBm) Max. tune-up 5.2GWIFI 13.33 13.0±1 5.8GWIFI 12.68 13.0±1 6. Standalone MPE Result As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =20cm, as well as the gain of the used antenna is refer to section, the RF power density can be obtained. Modulation Type Output power Antenna Gain (dBi) Antenna Gain (linear) MPE (mW/cm 2 ) MPE Limits (mW/cm 2 ) dBm mW BT 3.0 1.9953 1.08 1.2823 0.0005 1.0000 BLE 0.0 1.0000 1.08 1.2823 0.0003 1.0000 2.4GWIFI 16.0 39.8107 0.85 1.2162 0.0096 1.0000 5.2GWIFI 14.0 25.1189 1.12 1.2942 0.0065 1.0000 5.8GWIFI 14.0 25.1189 1.25 1.3335 0.0067 1.0000 Remark: 1. Output power (Peak) including turn-up tolerance; 2. MPE evaluate distance is 20cm from user manual provide by manufacturer. 7. simultaneous MPE Result 2.4GWIFI MPE (Ratio) BLE MPE (Ratio) simultaneous MPE (Ratio) MPE Limits (Ratio) 0.0096 0.0005 0.0101 1.0000 8. Conclusion The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of mobile device. ----------------THE END OF REPORT---------------
1. Antenna Description: Antenna type Internal antenna Model HY6-BT Frequency range 2400-2500MHz Manufacturer Shenzhen Huayin Communication Co. LTD ANT Peak Gain 1.08 dBi 2. Antenna Photo: Length: 14.43mm Width: 5.40mm 3. Test Equipment & Conditions 3.1 Test instrument VSWR is tested using Agilent E5071B connected to a hand mechanism, and the status is free space. 3.2 Test environment and methods 4.Antenna Radiation Pattern 2400MHz 2450MHz 2500MHz
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ..................... : FCC ID............................................. : CTA24082001502 2BDN3-HY6 Compiled by ( position+printed name+signature) . : File administrators Jinghua Xiao Supervised by ( position+printed name+signature) . : Project Engineer Xudong Zhang Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Aug. 28, 2024 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ............................ : Shenzhen Huaying Communication Co., LTD Address ............................................ : 4/F, Building 5, Saitu Digital Industrial Factory, No. 137, Bulan Road, Jihua Street, Longgang District, Shenzhen, China Test specification ........................... : Standard ........................................... : FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Projector Trade Mark ....................................... : N/A Manufacturer .................................... : Shenzhen Huaying Communication Co., LTD Model/Type reference ...................... : HY6 Listed Models .................................. : HY7, HY8, HY9, HY10, HY11, HY12, HY13, HY15, HY16, HY17, HY18, HY19, HY20 Modulation ....................................... : GFSK, Π/4DQPSK, 8DPSK Frequency ......................................... From 2402MHz to 2480MHz Rating ............................................... : AC 110-240V, 50/60Hz Result ............................................... : PASS Report No.: CTA24082001502 Page 2 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Projector Model /Type : HY6 Listed Models : HY7, HY8, HY9, HY10, HY11, HY12, HY13, HY15, HY16, HY17, HY18, HY19, HY20 Applicant : Shenzhen Huaying Communication Co., LTD Address : 4/F, Building 5, Saitu Digital Industrial Factory, No. 137, Bulan Road, Jihua Street, Longgang District, Shenzhen, China Manufacturer : Shenzhen Huaying Communication Co., LTD Address : 4/F, Building 5, Saitu Digital Industrial Factory, No. 137, Bulan Road, Jihua Street, Longgang District, Shenzhen, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA24082001502 Page 3 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 T E S T S T A N D A R D S .................................................................. 4 2 S U M M A R Y ............................................................................. 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Equipment Under Test 5 2.4 Short description of the Equipment under Test (EUT) 5 2.5 EUT operation mode 6 2.6 Block Diagram of Test Setup 6 2.7 Related Submittal(s) / Grant (s) 6 2.8 Modifications 6 3 T E S T E N V I R O N M E N T ............................................................... 7 3.1 Address of the test laboratory 7 3.2 Test Facility 7 3.3 Environmental conditions 7 3.4 Summary of measurement results 8 3.5 Statement of the measurement uncertainty 8 3.6 Equipments Used during the Test 9 4 T E S T C O N D I T I O N S A N D R E S U L T S ............................................ 11 4.1 AC Power Conducted Emission 11 4.2 Radiated Emission 14 4.3 Maximum Peak Output Power 20 4.4 20dB Bandwidth 21 4.5 Frequency Separation 25 4.6 Number of hopping frequency 27 4.7 Time of Occupancy (Dwell Time) 29 4.8 Out-of-band Emissions 33 4.9 Pseudorandom Frequency Hopping Sequence 42 4.10 Antenna Requirement 43 5 T E S T S E T U P P H O T O S O F T H E E U T .......................................... 44 6 P H O T O S O F T H E E U T ............................................................. 45 Report No.: CTA24082001502 Page 4 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules Part 15.247: Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz. ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices Report No.: CTA24082001502 Page 5 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai…
Text truncated - open the document above for the full version.
FCC ID: 2BDN3-HY6 Test Setup Photos of the EUT
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.70 mW |

smart watch
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
smart watch
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter