Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
3" 2"
REVISIONS SYM DESCRIPTION DCO DATE APPROVED 1 Initial Release 24005 06/21/24 MRC Signature Date 24 Walpole Park S., Unit 1 Walpole, MA 02081 1-800-795-0817 Drawn By: M. Cummings 06/21/24 Approvals: M. Cummings, Engineering 06/21/24 Tune Up Procedure Combine 6 6-Channel In-Ear Monitor TX Combiner Size Dwg. No. A 3073-6601 Sheet 1 of 2 RF Venue Tune Up Procedure, Combine 6 6/22/2024 2 of 2 3073-6601 Rev 1 1. FCC ID This Tune Up Procedure applies to FCC ID 2BDOJ-COMBINE6 2. Purpose This document is a procedure for verifying proper operation of the RF Venue Combine6 In-Ear Monitor Transmitter Combiner. It is intended to satisfy the requirements for a Tune Up Procedure for licensed devices under Part 74 per 47 CFR Part §2.1033(c)(12). There are no tuning adjustments or other calibration steps required during manufacturing or use for the device. All RF circuits are implemented with fixed values. During manufacturing, each device is tested to ensure proper operation and that the output power is within specified limits as documented in the referenced emissions test report. 3. Reference Documents Combine 6 User Guide Emissions Test Report 105431768BOX-001 4. Test Equipment Requirements The following equipment is required to perform this procedure. All equipment used must be calibrated per the manufacturer’s specifications. Equivalent equipment may be substituted with approval of the quality control manager. Keysight FieldFox RF Analyzer N9912A. An equivalent signal generator, spectrum analyzer or other RF measuring device may be used provided it is approved by the quality manager and supports the following: Frequency range to cover from 400 MHz to 700 MHz minimum Output power of +1 dBm at 539 MHz Two RG-58 50-ohm BNC cables, 3’ long. Cables should have a known loss and be periodically calibrated. 5. Procedure Set the RF Analyzer to generate a nominal +1 dBm continuous wave tone at 539 MHz. This is the TEST INPUT signal. Connect the generator port of the analyzer to the measurement port with one of the 3’ RG-58 cables (INPUT CABLE) and record the measured power Pin. Confirm Pin is greater than +0 dBm. Power on the DUT. Disconnect the INPUT CABLE from the analyzer’s measurement port and connect it to ACTIVE INPUT channel 1 of the DUT. The other input ports are left disconnected. Connect the ACTIVE OUTPUT port of the DUT to the analyzer’s measurement port using a second 3’ RG-58 cable with known loss Loc (dB). Record the measured output power Pout in dBm. Repeat for each channel. Calculate the DUT gain per channel as follows: Gdut (dB) = Pout (dBm) – Pin (dBm) + Loc (dB) 6. Test Limits The DUT gain shall be between -3 and +1 dB for each channel. Out-of-specification units shall be dispositioned as non-conforming material per RF Venue standard procedure.
RF VENUE, INC. MPE REPORT SCOPE OF WORK MPE Calculation on 6-to-1 Active RF Combiner REPORT NUMBER 105431768BOX-001.1 ISSUE DATE REVISION DATE January 23, 2024 March 4, 2024 DOCUMENT CONTROL NUMBER Non-Specific Radio Report Shell Rev. December 2017 © 2017 INTERTEK Non-Specific Radio Report Shell Rev. December 2017 Page 2 of 8 Client: RF Venue, Inc. – Model RF Venue Combine 6 MPE CALCULATION REPORT (FULL COMPLIANCE) Report Number: 105431768BOX-001.1 Project Number: G105431768 Report Issue Date: January 23, 2024 Report Revision Date: March 4, 2024 Model(s) Tested: RF VENUE COMBINE 6 Standards: FCC Part 1 Subpart I, April 2021 Procedures Implementing the National Environmental Policy Act of 1969 §1.1307 Actions that may have a significant environmental effect, for which Environmental Assessments (EAs) must be prepared. Tested by: Client: Intertek 70 Codman Hill Road Boxborough, MA 01719 USA RF Venue, Inc. 72 Nickerson Rd Ashland, MA 01721 USA Report prepared by Report reviewed by Vathana Ven / Sr. EMC Staff Engineer Kouma Sinn / Sr. EMC Staff Engineer This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Report Number: 105431768BOX-001.1 Issued: January 23, 2024 Revised: March 4, 2024 Non-Specific Radio Report Shell Rev. December 2017 Page 3 of 8 Client: RF Venue, Inc. – Model RF Venue Combine 6 Table of Contents 1 Introduction and Conclusion ..................................................................................................................... 4 2 Evaluation Summary ................................................................................................................................ 4 3 Client Information .................................................................................................................................... 5 4 Description of Equipment Under Test and Variant Models ......................................................................... 5 5 Power Density Calculation ........................................................................................................................ 6 6 Revision History ....................................................................................................................................... 8 Intertek Report Number: 105431768BOX-001.1 Issued: January 23, 2024 Revised: March 4, 2024 Non-Specific Radio Report Shell Rev. December 2017 Page 4 of 8 Client: RF Venue, Inc. – Model RF Venue Combine 6 1 Introduction and Conclusion This evaluation report covers for a mobile device subject to routine environmental evaluation for RF exposure. A mobile device is defined as a transmitting device designed to generally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter’s radiating structurer(s) and the body of the user or nearby persons. The evaluation indicated in section 2.0 were performed on the product constructed as described in section 4.0. The remaining sections are the verbatim text from the actual evaluation during the investigation. These sections include the evaluation name, the specified Method, and Results. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product evaluated complies with the requirements of the standard(s) indicated. The results obtained in this report pertain only to the item(s) evaluated. Intertek does not make any claims of compliance for samples or variants which were not evaluated. 2 Evaluation Summary Section Test full name Result 3 Client Information - 4 Description of Equipment Under Evaluation and Variant Models - 5 System Setup and Method - 6 Power Density Calculation (FCC §1.1310) Compliant 7 Revision History - Intertek Report Number: 105431768BOX-001.1 Issued: January 23, 2024 Revised: March 4, 2024 Non-Specific Radio Report Shell Rev. December 2017 Page 5 of 8 Client: RF Venue, Inc. – Model RF Venue Combine 6 3 Client Information This EUT was evaluated at the request of: Client: RF Venue, Inc. 72 Nickerson Rd. Ashland, MA 01721 USA Contact: Matt Glass Telephone: (800) 795-0817 Email: [email protected] 4 Description of Equipment Under Test and Variant Models Manufacturer: RF Venue, Inc. 72 Nickerson Rd. Ashland, MA 01721 USA Description of Equipment Under Test (provided by client) The EUT is a 6-to-1 Active RF Combiner. Equipment Under Test Power Configuration Rated Voltage Rated Current Rated Frequency Number of Phases 100-240 VAC 1.0 A 50/60 Hz 1 Variant Models: The following variant models have been identified by the manufacturer as being electrically identical models, depopulated models, or with reasonable similarity to the model(s) tested. Intertek does not make any claims of compliance for samples or variants which were not tested. None Intertek Report Number: 105431768BOX-001.1 Issued: January 23, 2024 Revised: March 4, 2024 Non-Specific Radio Report Shell Rev. December 2017 Page 6 of 8 Client: RF Venue, Inc. – Model RF Venue Combine 6 5 Power Density Calculation 5.1 Requirement(s) FCC §1.1310 Radiofrequency radiation expos…
Text truncated - open the document above for the full version.
RF VENUE, INC. TEST REPORT SCOPE OF WORK Emissions Testing of the 6-to-1 Active RF Combiner REPORT NUMBER 105431768BOX-001R1 ISSUE DATE [REVISED DATE] 01/12/2024 06/27/2024 DOCUMENT CONTROL NUMBER Non-Specific Radio Report Shell Rev. October 2022 © 2022 INTERTEK Non-Specific Radio Report Shell Rev. October 2022 Page 2 of 69 Client: RF Venue, Inc. – Model: RF Venue Combine 6 EMISSIONS TEST REPORT (FULL COMPLIANCE) Report Number: 105431768BOX-001R1 Project Number: G105431768 Report Issue Date: 01/12/2024 Report Revision Date: 06/27/2024 Model(s) Tested: RF VENUE COMBINE 6 Model(s) Partially Tested: None Model(s) Not Tested but declared equivalent by the client: None Standards: FCC PART 74, Subpart H:2024 – Low Power Auxiliary Stations KDB 935210 D02 Signal Boosters Certification v04r02 KDB 935210 D05 Industrial Booster Basic Meas v01r04 KDB 971168 D03 IM Emission Repeater Amp v01 Tested by: Client: Intertek 70 Codman Hill Road Boxborough, MA 01719 USA RF Venue, Inc. 72 Nickerson Rd Ashland, MA 01721 USA Report prepared by Report reviewed by Vathana Ven / Senior Staff Engineer Kouma Sinn / Senior Staff Engineer This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Report Number: 105431768BOX-001R1 Issued: 01/12/2024 Revised: 06/27/2024 Non-Specific Radio Report Shell Rev. October 2022 Page 3 of 69 Client: RF Venue, Inc. – Model: RF Venue Combine 6 Table of Contents 1 Introduction and Conclusion .............................................................................................................. 4 2 Test Summary ...................................................................................................................................... 4 3 Client Information ................................................................................................................................ 5 4 Description of Equipment Under Test and Variant Models ............................................................. 5 5 System Setup and Method .................................................................................................................. 7 6 RF Output Power (Mean Input Power vs. Mean Output Power) ...................................................... 8 7 Occupied Bandwidth (Input vs. Output) .......................................................................................... 18 8 Transmitter Unwanted Emission (Radiated or Conducted)........................................................... 34 9 Emission Masks ................................................................................................................................. 54 10 AC Mains Conducted Emissions .................................................................................................. 65 11 Revision History ............................................................................................................................. 69 Intertek Report Number: 105431768BOX-001R1 Issued: 01/12/2024 Revised: 06/27/2024 Non-Specific Radio Report Shell Rev. October 2022 Page 4 of 69 Client: RF Venue, Inc. – Model: RF Venue Combine 6 1 Introduction and Conclusion The tests indicated in section 2.0 were performed on the product constructed as described in section 4.0. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. Intertek does not make any claims of compliance for samples or variants which were not tested. 2 Test Summary Section Test full name Result 3 Client Information -- 4 Description of Equipment Under Test and Variant Models -- 5 System Setup and Method -- 6 RF Output Power FCC Part 74.861(e)(1)(ii), KDB 935210 D05 Industrial Booster Basic Meas v01r04 Section 3.5 Pass 7 Occupied Bandwidth FCC Part 74.861(e)(5), KDB 935210 D05 Industrial Booster Basic Meas v01r04 Section 3.4 Pass 8 Transmitter Unwanted Emissions (Radiated or Conducted), Intermodulation Emissions FCC Part 74.861(e)(6), KDB 971168 D03 IM Emission Repeater Amp v01 Pass 9 Emission Masks FCC Part 74.861(e)(7) Pass 10 Conducted Emissions on AC Mains FCC Part 15.207 Pass 11 Revision History -- Intertek Report Number: 105431768BOX-001R1 Issued: 01/12/2024 Revised: 06/27/2024 Non-Specific Radio Report Shell Rev. October 2022 Page 5 of 69 Client: RF Venue, Inc. – Model: RF Venue Combine 6 3 Client Information This EUT was tested at the request of: Client: RF Venue, Inc. 72 Nickerson Rd. Ashland, MA 01721 USA Contact: Matt Glass Telephone: (800) 795-0817 Email: [email protected] 4 Description of Equipment Under Test and Variant Models Manufacturer: RF Venue, Inc. 72 Nickerson Rd. Ashland, MA 01721 USA Equipment Under Test Description Manufacturer Mod…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 74H | 470 MHz - 608 MHz | 21.00 mW | 184KF3E | 2.5000000000 ppm |
In-Ear Monitor Transmitter Combiner
Equipment Class
DWM - Part 15 Wireless MicrophoneIn-Ear Monitor Transmitter Combiner
Equipment Class
DWM - Part 15 Wireless Microphone