Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Dec 03, 2023
Application Purpose
Original Equipment
Date of Application
Dec 03, 2023
Equipment Note
Portable Power Station
Frequency Range
0.11300000 - 0.20500000
Company
Shenzhen Hongyou Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1. Please keep dry and keep away from fire. 2. Do not disassemble, puncture, perform irregular operations on the exposed ports or strongly impact the product. 3. Be careful about yourself and anyone else when transporting. 4. For children or people with limited intelligence, please pay attention to use under the protection of guardians. 5. It is strictly forbidden to use accessories other than our company for the power extension port. All consequences caused by illegal operation shall be borne by the customer. 6. It is strictly forbidden to use it in a waterproof bag or other protective cover to avoid excessive internal temperature of the device and cause danger HSECPTOW-G63 Portable Power Station User Manual 7.Please recycle and throw product according to local law. Warning 2 Keynotes The product uses the following terms to classify the potential hazards that may be caused by improper operation. Attention If you do not follow the instructions, it may cause property damage and minor injuries. External electrical appliances need to be within the power and voltage range of the interface Cautious If you do not follow the instructions, it may cause property damage and serious injury. Warning If you do not follow the instructions, it may cause large property damage, major accidents and serious injuries. Important reminder Please reading the user manual and familiarize yourself with the functions of the product before operation. If it is not operated correctly, may cause serious injury to itself or others, or cause product damage and property loss. Our company does not assume any legal responsibility. Do not use parts that are not provided or recommended by our company. You must strictly follow our company's guidelines to install and use the product. Otherwise, you will not be able to get our company's free after-sales service. Be sure to read the user manual carefully before assembling, setting up and using it. Product safety guidelines Improper use may cause fire or property rights or personal injury. Be sure to use the product in accordance with the following safety guidelines. 3 Product use 1. It is strictly forbidden to make the product come into contact with any liquid. Do not immerse the product in water or get it wet. Do not use this equipment in rain or humid environment. Otherwise, the battery may ignite spontaneously, and may even cause an explosion. 2. It is strictly forbidden to use unofficial parts. If you need to replace it, Please consult the purchasing channel for relevant purchasing information. The company is not responsible for product failures or accidents caused by the use of products that are not officially provided by the company. 3.Before installing or unplugging Spare battery modules of the device, please keep the power supply of the device turned off. Do not remove or insert Spare battery modules when the power of the device is turned on, otherwise the power interface may be damaged. This product should be used in an ambient temperature of -20°C to 60°C. Too high temperature (above 60°C) may cause the battery to catch fire or even explode. If the temperature is too low (below -20C), the product performance will be severely reduced, and it may not meet the normal use requirements. It can be used normally after returning to normal temperature. 5.It is forbidden to use this equipment in a strong static electricity or strong magnetic field environment, as it may not work properly. Otherwise, some protection functions of the device may fail, causing serious failure of the device. 6. It is forbidden to disassemble or pierce the product with sharp objects in any way. Otherwise, the product will malfunction, catch fire or even explode. 7. The equipment must not be used again after it has been severely dropped or hit by an external force. 4 8. If the product accidentally falls into the water during use, place it in a safe open area until the product is completely dry. The dried product should not be used again and should be properly disposed of according to the disposal method in this article. If the product catches fire, it is recommended to use fire extinguishing equipment in the following order: sand, fire blanket, dry powder and carbon dioxide fire extinguisher. 9. Do not place the equipment outdoors or in a pressure cooker. 10. It is forbidden to use wires or other metal objects to avoid short circuit of the product. 11. Do not place heavy objects on the machine. 12. If the machine is dirty, wipe it with a dry cloth. Otherwise it will lead to poor contact, resulting in energy consumption or failure to charge. Product charging 1. The machine must be charged using the Adapter officially designated by the company. The company will not be responsible for all consequences caused by charging using a Adapter that is not officially designated by the company. 2. When charging, please place the machine on the ground where there is no flammable or combustible materials around, such as cement. Please be on-site to supervise the product while it is charging to prevent accidents. 3. After continuous full-load discharge, if the product battery is in a high temperature state, it is recommended to cooled the device till it is in room temperature before charging, otherwise charging may be prohibited, the rechargeable environment temperature of the battery is 0°C-40°C, and the ideal charging environment temperature (20°C-30°C) can greatly extend the service life of the battery. 5 Product storage and transportation 1. Please store the equipment out of reach of children. If a child accidentally swallows parts, seek medical attention immediately. 2. If the machine prompts severely low battery after use, please charge it before storing. Otherwise, long-term storage may cause damage to the battery inside the product. If the battery of the machine is severely insufficient and the idle time is too long, the battery will enter the deep sleep mode. If the battery needs to be awakened from deep slee…

Text truncated - open the document above for the full version.

External Photos

Page 1 of 5FCC ID: 2BDOR-HSECPTOW Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. EUT Constructional Details External EUT Photo Photo 1 Photo 2 Page 2 of 5FCC ID: 2BDOR-HSECPTOW Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 3 Photo 4 Page 3 of 5FCC ID: 2BDOR-HSECPTOW Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 5 Photo 6 Page 4 of 5FCC ID: 2BDOR-HSECPTOW Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 7 Photo 8 Page 5 of 5FCC ID: 2BDOR-HSECPTOW Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 9 Photo 10 ---The End---

ID Label/Location Info

Label FCCID:2BDOR-HSECPTOW

Internal Photos

Page1of20FCCID: 2BDOR-HSECPTOW DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. EUTConstructionalDetails InternalEUTPhoto Photo1 Photo2 Page2of20FCCID: 2BDOR-HSECPTOW DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo3 Photo4 Antenna Page3of20FCCID: 2BDOR-HSECPTOW DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo5 Photo6 Page4of20FCCID: 2BDOR-HSECPTOW DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo7 Photo8 Page5of20FCCID: 2BDOR-HSECPTOW DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo9 Photo10 Page6of20FCCID: 2BDOR-HSECPTOW DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo11 Photo12 Page7of20FCCID: 2BDOR-HSECPTOW DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo13 Photo14 Page8of20FCCID: 2BDOR-HSECPTOW DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo15 Photo16 Page9of20FCCID: 2BDOR-HSECPTOW DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo17 Photo18 Page10of20FCCID: 2BDOR-HSECPTO W DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo19 Photo20 Page11of20FCCID: 2BDOR-HSECPTO W DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo21 Photo22 Page12of20FCCID: 2BDOR-HSECPTO W DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo23 Photo24 Page13of20FCCID: 2BDOR-HSECPTO W DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo25 Photo26 Page14of20FCCID: 2BDOR-HSECPTO W DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo27 Photo28 Page15of20FCCID: 2BDOR-HSECPTO W DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo29 Photo30 Page16of20FCCID: 2BDOR-HSECPTO W DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo31 Photo32 Page17of20FCCID: 2BDOR-HSECPTO W DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo33 Photo34 Page18of20FCCID: 2BDOR-HSECPTO W DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo35 Photo36 Page19of20FCCID: 2BDOR-HSECPTO W DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo37 Photo38 Page20of20FCCID: 2BDOR-HSECPTO W DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo39 Photo40 ------End------

RF Exposure Info

Page 1 of 6 FCCID:2BDOR-HSECPTOW RFExposureEvaluation 1MeasuringStandard KDB680106RFExposureWirelessChargingAppsv03r01 2Requirements Accordingtotheitem5ofKDB680106v03r01: Inductivewirelesspowertransferapplicationsthatmeetallofthefollowingrequirementsareexcludedfrom submittinganRFexposureevaluation. (1)Powertransferfrequencyislessthan1MHz. (2)Outputpowerfromeachprimarycoilislessthanorequalto15watts. (3)Thesystemmayconsistofmorethanonesourceprimarycoils,chargingoneormoreclients.Ifmorethan oneprimarycoilispresent,thecoilpairsmaybepoweredonatthesametime. (4)Clientdeviceisplaceddirectlyincontactwiththetransmitter. (5)Mobileexposureconditionsonly(portableexposureconditionsarenotcoveredbythisexclusion). (6)TheaggregateH-fieldstrengthsanywhereatorbeyond15cmsurroundingthedevice,and20cm awayfromthesurfacefromallcoilsthatbydesigncansimultaneouslytransmit,andwhilethose coilsaresimultaneouslyenergized,aredemonstratedtobelessthan50%oftheapplicableMPE limit. Remark:Meetalltheaboverequirements. Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Page 2 of 6 FCCID:2BDOR-HSECPTOW 3TestSetup 4TestProcedure 1)TheRFexposuretestwasperformedinanechoicchamber. 2)Themeasurementprobewasplacedattestdistance(15cmfromallsidesand20cmfromthetop)whichis betweentheedgeofthechargerandthegeometriccenterofprobe. 3)Thehighestemissionlevelwasrecordedandcomparedwithlimitassoonasmeasurementofeachpoints (A,B,C,D,E)werecompleted. 4)TheEUTwasmeasuredaccordingtothedictatesofKDB680106D01v03. Remark:TheEUT’stestpositionA,B,C,DandEisvalidfortheEandHfieldmeasurements. 5Descriptionofthetestmode Equipmentundertestwasoperatedduringthemeasurementunderthefollowing conditions: Test Mode Description Mode1 ACAdapter+EUT+ Load Record Mode2 TesttheEUTinidlemode. Pre-tested Note:1.Alltestmodeswerepre-tested,butweonlyrecordedtheworstcaseinthisreport. 2.Unfoldedandfoldedmodeweretested,butweonlyrecordedtheworstcase. Page 3 of 6 FCCID:2BDOR-HSECPTOW 6PeripheralList 7TestInstrumentslist TestEquipmentManufacturerModelNo.SN. Cal.Date (mm-dd-yy) Cal.Duedate (mm-dd-yy) ElectricandMagnetic FieldAnalyzer NardaEHP-200A180ZX1050521.06.202220.06.2024 8TestResult E-FiledStrengthat15cmfromtheedgessurroundingtheEUT(V/m) UnitTestmode TM1 Test Position A Test Position B Test Position C Test Position D Test Position E 50% Limits (V/m) Limits (V/m) V/mPhoneport 93.123104.51193.22892.25690.347 307614 H-FiledStrengthat15cmfromtheedgessurroundingtheEUT(A/m) UnitTestmode TM1 Test Position A Test Position B Test Position C Test Position D Test Position E 50% Limits (A/m) Limits (A/m) A/mPhoneport 0.2310.2190.2300.1890.170 0.8151.63 H-FiledStrengthat20cmfromthetopoftheEUT(A/m) UnitTestmode TM1 Test PositionE 50%Limits (A/m) Limits (A/m) TM1 A/mPhoneport 0.202 0.8151.63 Note:Alltestmodeswerepre-tested,butweonlyrecordedtheworstcaseinthisreport. N o. EquipmentManufacturerModelNo.SerialNo.Powercordsignalcable 1 Wireless charger receiver SLY15WN/A N/AN/A 2Adapter Shenzhen Liankelilong Electronic Technology Co.,Ltd. LK150-2000350N/AN/AN/A Page 4 of 6 FCCID:2BDOR-HSECPTOW 9TestSetupphoto TestPositionA-15cmfromtheedgeofEUTtothegeometriccenteroftheprobe TestPositionB-15cmfromtheedgeofEUTtothegeometriccenteroftheprobe Page 5 of 6 FCCID:2BDOR-HSECPTOW TestPositionC-15cmfromtheedgeofEUTtothegeometriccenteroftheprobe TestPositionD-15cmfromtheedgeofEUTtothegeometriccenteroftheprobe Page 6 of 6 FCCID:2BDOR-HSECPTOW TestPositionE-15cmfromtheedgeofEUTtothegeometriccenteroftheprobe TestPositionE-20cmfromtheedgeofEUTtothegeometriccenteroftheprobe ***Endofreport***

Test Report

Page1of23ReportNo.:AIT23112003FW1 DongguanYaxu(AiT)TechnologyLimited No.22,JinqianlingThirdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. FCCTESTREPORT ClientInformation: Applicant:ShenzhenHongyouTechnologyCo.,Ltd. Applicantadd.: Room702,Building2AB,QianqianlingRow,TangweiCommunity,Fenghuang Street,GuangmingDistrict,ShenzhenCity,GuangdongProvince,China Manufacturer:ShenzhenHongyouTechnologyCo.,Ltd. Manufactureradd.: Room702,Building2AB,QianqianlingRow,TangweiCommunity,Fenghuang Street,GuangmingDistrict,ShenzhenCity,GuangdongProvince,China ProductInformation: ProductName:PortablePowerStation ModelNo.:HSECPTOW-G63,HSECPTOW-R63,HSECPTOW-G32,HSECPTOW-R32 BrandName:N/A FCCID:2BDOR-HSECPTOW Applicablestandards:FCCCFRTitle47Part15SubpartC PreparedBy: DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang,Huangjiang,Dongguan, Guangdong,China Tel.:+86-769-82020499Fax.:+86-769-82020495 DateofReceipt:Nov.20,2023DateofTest:Nov.21,2023~Nov.23,2023 DateofIssue:Nov.24,2023TestResult:Pass ThisdevicedescribedabovehasbeentestedbyDongguanYaxu(AiT)TechnologyLimitedandthe testresultsshowthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements. Anditisapplicableonlytothetestedsampleidentifiedinthereport. Note:Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofDongguan Yaxu(AiT)TechnologyLimited,thisdocumentmaybealteredorrevisedbyDongguanYaxu(AiT) TechnologyLimited,personalonly,andshallbenotedintherevisionofthedocument.Thistest reportmustnotbeusedbytheclienttoclaimproductendorsement. Reviewedby:Approvedby: SimbaHuangSeal.chen Page2of23ReportNo.:AIT23112003FW1 DongguanYaxu(AiT)TechnologyLimited No.22,JinqianlingThirdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. 1Contents Page COVERPAGE 1CONTENTS..................................................................................................................................................................2 2TESTSUMMARY........................................................................................................................................................5 2.1STATEMENTOFTHEMEASUREMENTUNCERTAINTY..................................................................................................5 2.2MEASUREMENTUNCERTAINTY.................................................................................................................................5 3TESTFACILITY...........................................................................................................................................................6 3.1DEVIATIONFROMSTANDARD...................................................................................................................................6 3.2ABNORMALITIESFROMSTANDARDCONDITIONS........................................................................................................6 3.3TESTLOCATION......................................................................................................................................................6 4GENERALINFORMATION.........................................................................................................................................7 4.1EUTTESTMODE....................................................................................................................................................8 4.2DESCRIPTIONOFTESTSETUP.................................................................................................................................8 4.3PERIPHERALLIST....................................................................................................................................................9 4.4EUTPERIPHERALLIST...........................................................................................................................................9 5EQUIPMENTSLISTFORALLTESTITEMS...........................................................................................................10 6CONDUCTEDEMISSIONTEST...............................................................................................................................11 6.1CONDUCTEDEMISSIONMEASUREMENT.....................................................................................................11 6.2POWERLINECONDUCTEDEMISSIONLIMITS................................................................................................11 6.3TESTPROCEDURE...........................................................................................................................................11 6.4DEVIATIONFROMTESTSTANDARD..............................................................................................................11 6.5TESTSETUP......................................................................................................................................................12 6.6EUTOPERATINGCONDITIONS.......................................................................................................................12 6.7TESTRESULT.......................................................................................................................................................13 7RADIATEDEMISSIONMEASUREMENT................................................................................................................15 7.1RADIATEDEMISSIONLIMITS..................................................................................................................................15 7.2ANECHOICCHAMBERTESTSETUPDIAGRAM.........................................................................................................16 7.3TESTPROCEDURE................................................................................................................................................16 7.4DEVIATIONFROMTESTSTANDARD..............................................................................................................16 7.5TESTRESULT........................................................................…

Text truncated - open the document above for the full version.

Test Report

ITE 线圈规格图Coil specifications picture MSpec. L9.5UH±5% Q值130MAX D.C.R0.06ΩMax A50±1mm B45±1mm C20±0.5mm D40±2mm E3±2mm Operation Frequency: 113kHz-205kHz Antenna Gain: 0dBi

Test Setup Photos

Page1of2FCCID: 2BDOR-HSECPTOW DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. TestSetupPhoto RadiatedEmission Page2of2FCCID: 2BDOR-HSECPTOW DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. ConductedEmission ------End------

Contact Information

Applicant

Shangzheng Sun
[email protected]14774938904Fax: N/A

Test Firm

Dongguan Yaxu (AiT) Technology LimitedCoin Tang
[email protected]+86 0769-82020499-21

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.113 MHz - 0.205 MHz-
Confidentiality
Long Term