FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD/
  3. 2BDRK-S5

2BDRK-S5S5 wireless microphone

ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD
S5 wireless microphone - FCC ID 2BDRK-S5 - ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD
Click to zoom

Application Details

Equipment Class
TLD - Licensed LPAS Device
Date of Grant
Nov 28, 2023
Application Purpose
Original Equipment
Date of Application
Nov 28, 2023
Equipment Note
S5 wireless microphone
Frequency Range
540.00000000 - 564.75000000
Company
ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

I Hand held microphone(Transmitter) J ①Infrared synchronization window Infrared synchronizatio n window臼n receive synchronous data sent from the receive巳the tran号mitterto work in the frequency of the re�1ver. E二百iightlit:'Fi;e":肖condsback light turns off. �� c When the back light blinks tti.at indicate ba忧:eryis dead, reolace the ba忧eries as soon as oo随 i (§) Power switch, mute button Short press: power turn on, the power on Press mute I unmute. Press 3 seconas: tum off. ④T ransmit power adiustment RF H high power, RF1. low-power, short distan四use,tuned to RF L l9w-powers恼钮,to reduce the transmit powe口inte『ferencefrom other 但vi四s and redu田J>Owerconsumption, keep battery for longer time. @Intelligent mute switch Shor1 p陪ss the intelligen! mute switc的to turn on _pr o仔theautomatic mute function, intelligent mute is turned on indi臼ted ''1JJ, no indi臼ted when tum o何. ”寸_ l �售� i !!t: n �!f1�C - �吃:h�_r:il_:_: - - -- - -- - -- - -- - - - - -- - -- - -- - -- - -- -- - - - - -- - - - - - - 『、 、 : In Uie i啪”ig创microphonemode ', : 1.microphone automatically en阳the mu阳mode川enU,e microphone d。”notoperate for more than 5 i ! 国conds,ifmicrophone have It回句圃硝口nautomatically resum画theworking mode; ; ; 2.microphone d 口回not口pe阻恒formore than 5『ninu恒玩世lemicrophone auton回ti回llyen阳百thesleep : n回串andsto � t闹闹mlttlngsignals to the receiver.If microphone have。”ration刷刷na四callye幅降 I WOf中dngmode; ; 3.Miα-ophone no opera! for mo陪than 15minu也s,伽e system will automatically tum o霄U,e microphor悟, ',_and ne国bbe manually刷刷刷onto work nonnall萨 ,’ 写『』--------------------------------------------------------------’ SCREEN FOR HANDHOLDER 1 111111 rrr» 心+ |刊 .000 MICROPHONE 吊J (3}-一一斗’[ �MUTE 融 (!)The indication for frequency. (2)"Mute ” flashes that means it has been mute. @Indication for power of batte叩.It have been changed t。newone when :::::Ji is flashing. ④lntellingent microphone mute indication. turn on have this log。 Ba忧eryreplacement Counter clock wiser,。tationof the tube b。dy to the microphone, threads are screwed out, back to slide bod¥ is exposed out of the batterv slot in the correct battery, replace1he batte『y. Svstem microch。ne bv acoustic devices and sochisticated erectronic device composition use caution whe币 custody, forbid dropping, beat the severe impact, otherwise, microphones are e叫to 6e broken. e m;电亘古国司百E画茸3国ml耳唱· Carrierfrequency: UHF540-564.75MHz Channel number: 100Channel, Frequency interval: 50Hz-1 B KHz RF mode: High-perf ormance integrated IC RF bandwidth:24.75MHz SNR:>105dB Dynamic range: >100dB THD: <1.0%@1KHz Working temperature range:-18-50°C Working range: About 150M R eceiver Receive mode: High-performance integrated IC and Double demodulation true diversity Sensitivity range:>-105dB/m(20dB SNR) Display mode:LCD Audio output :Two c hannel Mixed output/Two channel balance/Unbalanced Trans『n itter RF frequency accuracy:±50ppm<1 OKHz Frequency offset:25KHz Harmonic:<-45dB/c Output power:>10dB/m Display: LCD(Hand-held microphone) Current c。nsumption:<1 50mA@3V Power supply:AA 1.5V *2PCS Battery life: > 8 hours �宽E田 1.Receive『:1pcs 3.Audio cable: 1 pcs 5. Antenna:4pcs 7.lnstructi。n Book:1 pcs 2.Hand-held microphone:2pcs 4.Powe「Adapter:1 pcs 6.1.5V AAbattery:4pcs 。 FCC Warning This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. The users manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment Radiation Exposure Statement The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Attestation Statements

ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 11/26/2023 U.S. Agent Designation ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BDRK-S5): Name and company of U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD. ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD with the FRN 0034527226 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Since rely, Signature PEIYU TAN MANAGER ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD Signature Tim Payne Manager FCC US Agent, LLC 48_[model] US_Agent_2.911(d)(7)-U, V05

Attestation Statements

Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD Address: A1, AREA 1, ENPING INDUSTRIAL PARK OF JIANGMEN INDUSTRIAL TRANSFER ZONE, ENPING GUANGDONG 529400, China Phone: +86-750-7811717 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-11-24 Name / Title: PEIYU TAN / MANAGER Company: ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD Address: A1, AREA 1, ENPING INDUSTRIAL PARK OF JIANGMEN INDUSTRIAL TRANSFER ZONE, ENPING GUANGDONG 529400, China Phone: +86-750-7811717 Fax: +86-750-7821392 E-Mail: [email protected]

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BDRK-S5 S5, H6, ES-U2, ES-U1, ES-601, M3, UW950, UW970, UW980, UW780, S1, ES-888 We, applicant Company Name: ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD Address: A1, AREA 1, ENPING INDUSTRIAL PARK OF JIANGMEN INDUSTRIAL TRANSFER ZONE, ENPING GUANGDONG 529400, China Phone: +86-750-7811717 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Sincerely, Signature Date:2023-11-24 Name / Title: PEIYU TAN / MANAGER Company: ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD Address: A1, AREA 1, ENPING INDUSTRIAL PARK OF JIANGMEN INDUSTRIAL TRANSFER ZONE, ENPING GUANGDONG 529400, China Phone: +86-750-7811717 Fax: +86-750-7821392 E-Mail: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BDRK-S5 S5, H6, ES-U2, ES-U1, ES-601, M3, UW950, UW970, UW980, UW780, S1, ES-888 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Procedure The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-11-24 Name / Title: PEIYU TAN / MANAGER Company: ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD Address: A1, AREA 1, ENPING INDUSTRIAL PARK OF JIANGMEN INDUSTRIAL TRANSFER ZONE, ENPING GUANGDONG 529400, China Phone: +86-750-7811717 Fax: +86-750-7821392 E-Mail: [email protected]

Cover Letter(s)

ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD A1, AREA 1, ENPING INDUSTRIAL PARK OF JIANGMEN INDUSTRIAL TRANSFER ZONE, ENPING GUANGDONG 529400, China Date: November 24, 2023 FCC ID: 2BDRK-S5 Model Number: S5, H6, ES-U2, ES-U1, ES-601, M3, UW950, UW970, UW980, UW780, S1, ES-888 To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD hereby declare that our product (S5 wireless microphone) Model Number: S5, H6, ES-U2, ES-U1, ES-601, M3, UW950, UW970, UW980, UW780, S1, ES-888 board, Schematic, Hardware version, Software version, structure and internal photos are same, named and appearance differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name / Title: PEIYU TAN / MANAGER Company: ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD Address: A1, AREA 1, ENPING INDUSTRIAL PARK OF JIANGMEN INDUSTRIAL TRANSFER ZONE, ENPING GUANGDONG 529400, China Phone: +86-750-7811717 Fax Number: +86-750-7821392 E-Mail: [email protected]

External Photos

Page 1 of 3 FCC ID:2BDRK-S5 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 3 FCC ID:2BDRK-S5 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 3 FCC ID:2BDRK-S5 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6

ID Label/Location Info

Page 1 of 1 FCC ID:2BDRK-S5 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L: 2.0cm x W: 1.5cm) Label Location S5 wireless microphone Model: S5 FCC ID:2BDRK-S5

Internal Photos

Page 1 of 3 FCC ID:2BDRK-S5 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 3 FCC ID:2BDRK-S5 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 3 FCC ID:2BDRK-S5 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Antenna

RF Exposure Info

Page 1 of 2 FCC ID:2BDRK-S5 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information Product name S5 wireless microphone Test Model S5 Additional Model No. H6,ES-U2,ES-U1,ES-601,M3,UW950,UW970,UW980,UW780,S1, ES-888,UW960,S7,M1 Model Declaration PCB board, structure and internal of these model(s) are the same, So no additional models were tested Power supply DC 3.0V by 2*AA Batteries Hardware Version TX: ES-P7TX-MXW Software Version RX: ES-2CHFJRX-V4-MXW(540-590MHZ) Frequency Range 540MHz-564.75MHz Channel Number 100 channels Modulation Type FM Antenne Description Internal Antenna, 2.5dBi (Max.) Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Portable Device 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.23 “ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. Page 2 of 2 FCC ID:2BDRK-S5 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 3. Refer evaluation method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices 4. Conducted Power Results Test Mode Frequency (MHz) Measured Maximum Peak Power(dBm) Limits (dBm) Verdict FM 540.00 12.974 24 PASS FM 552.25 12.697 24 PASS FM 564.75 12.535 24 PASS 5. Manufacturing tolerance FM Channel(MHz) (Peak) Frequency 540.00 552.25 564.75 Target (dBm) 12 12 12 Tolerance ±(dB) 1.0 1.0 1.0 6. Evaluation Results Band/Mode f (GHz) Antenna Distance (mm) RF output power SAR Test Exclusion Threshold SAR Test Exclusion dBm mW FM 0.54000 5 13 19.9526 2.9324< 3.0 Yes FM 0.55225 5 13 19.9526 2.9655< 3.0 Yes FM 0.56475 5 13 19.9526 2.9989< 3.0 Yes Remark: 1. Output power including tune up tolerance; 2. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 of KDB447498 is applied to determine SAR test exclusion. 7. Conclusion The measurement results comply with the FCC Limit per 47 CFR 2.1093 for the uncontrolled RF Exposure and SAR Exclusion Threshold per KDB 447498 v06. .......................THE END OF REPORT.........................

Test Report

Page 1 of 30 FCC ID:2BDRK-S5 Report No.: LCSA10263032EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD S5 wireless microphone Test Model: S5 Additional Model No.: Please Refer to Page 6 Prepared for : ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD Address : A1, AREA 1, ENPING INDUSTRIAL PARK OF JIANGMEN INDUSTRIAL TRANSFER ZONE, ENPING CITY, GUANGDONG PROVINCE, CHINA Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : October 27, 2023 Number of tested samples : 2 Sample No : A10263032-1, A10263032-2 Serial number : Prototype Date of Test : October 27, 2023 ~ November 22, 2023 Date of Report : November 24, 2023 Page 2 of 30 FCC ID:2BDRK-S5 Report No.: LCSA10263032EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 74 Report Reference No. ................. : LCSA10263032EA Date of Issue ................................... : November 24, 2023 Testing Laboratory Name ............. : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD Address ........................................... : A1, AREA 1, ENPING INDUSTRIAL PARK OF JIANGMEN INDUSTRIAL TRANSFER ZONE, ENPING CITY, GUANGDONG PROVINCE, CHINA Test Specification Standard .......................................... : FCC CFR 47 PART 74 Test Report Form No. ................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. ........................... : S5 wireless microphone Trade Mark ...................................... : EALSEM Test Model ..................................... : S5 Ratings ............................................ : DC 3.0V by 2*AA Batteries Result ............................................ : Positive Compiled by: Supervised by: Approved by: Jack Liu/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 30 FCC ID:2BDRK-S5 Report No.: LCSA10263032EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Model........................... : S5 EUT......................................... : S5 wireless microphone Applicant............................... : ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD Address.................................. : A1, AREA 1, ENPING INDUSTRIAL PARK OF JIANGMEN INDUSTRIAL TRANSFER ZONE, ENPING CITY, GUANGDONG PROVINCE, CHINA Telephone............................... : / Fax.......................................... : / Manufacturer........................ : ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD Address................................... : A1, AREA 1, ENPING INDUSTRIAL PARK OF JIANGMEN INDUSTRIAL TRANSFER ZONE, ENPING CITY, GUANGDONG PROVINCE, CHINA Telephone............................... : / Fax.......................................... : / Factory................................... : ENPING YIXING ELECTRONIC EQUIPMENT CO., LTD Address................................... : A1, AREA 1, ENPING INDUSTRIAL PARK OF JIANGMEN INDUSTRIAL TRANSFER ZONE, ENPING CITY, GUANGDONG PROVINCE, CHINA Telephone............................... : / Fax.......................................... : / Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA10263032EA November 24, 2023 Date of issue Page 4 of 30 FCC ID:2BDRK-S5 Report No.: LCSA10263032EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Revision Issue Date Revision Content Revised By 000 November 24, 2023 Initial Issue -- Page 5 of 30 FCC ID:2BDRK-S5 Report No.: LCSA10263032EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Ya…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 1 FCC ID:2BDRK-S5 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photos of the EUT Below 1GHz Above 1GHz

Contact Information

Applicant

PEIYU TAN
[email protected]0750-7811717Fax: 0750-7821392

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
174H540 MHz - 564.75 MHz19.80 mW111KF3E5.0900000000 ppm
Confidentiality
Long Term
Grant Notes
Power listed is maximum peak conducted output power. This filing meets the SAR threshold exclusion set forth in KDB 447498 and therefore can be used in mobile/portable configurations. The antenna used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.