FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Chengdu Lelian Zhichuang Technology Co., Ltd/
  3. 2BDZT-UBX01

2BDZT-UBX01UltraBARX

Chengdu Lelian Zhichuang Technology Co., Ltd
UltraBARX - FCC ID 2BDZT-UBX01 - Chengdu Lelian Zhichuang Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 05, 2026
Application Purpose
Original Equipment
Equipment Note
UltraBARX
Frequency Range
2402.00000000 - 2480.00000000
Company
Chengdu Lelian Zhichuang Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

โ†—

Attestation Statements

โ†—
โ†—

Cover Letter(s)

โ†—
โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

RF Exposure Info

โ†—

Test Report

โ†—
โ†—
โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates,uses and can radiate radio frequency energy and,if not installed and used in accordance with the instructions,may cause harmful interference to radio communications. However,there is no guarantee that interference will not occur in a particlar installation.If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body

Attestation Statements

Rev1/26/2023 ChengduLelianZhichuangTechnologyCo.,Ltd FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:8-25-2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BDZT-UBX01 ChengduLelianZhichuangTechnologyCo.,Ltdcertifiesthattheequipmentforwhichauthorizationis soughtisnotโ€œcoveredโ€equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules. ChengduLelianZhichuangTechnologyCo.,Ltdcertifiesthattheequipmentforwhichauthorizationis soughtdoesnotincludecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc. oranyofitssuccessorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyof itssuccessorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB 986446D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature) (Applicantprintedname)ChenXiaoLin Rev1/26/2023 ChengduLelianZhichuangTechnologyCo.,Ltd FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:8-25-2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BDZT-UBX01 ChengduLelianZhichuangTechnologyCo.,Ltdcertifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofits subsidiariesoraffiliates)asanentityproducingโ€œcoveredโ€equipment. Sincerely, (Applicantsignature) (Applicantprintedname) ChenXiaoLin

Attestation Statements

ChengduLelianZhichuangTechnologyCo.,Ltd No.202,floor2,building1,No.1288,HuandaoRoad,hightechZone,Chengdu,SichuanProvince U.S.AgentLetterofAttestation To:FederalCommunicationsCommission 7435OaklandMillsRoad,Columbia,MD21046,USA Date:Aug.31,2026 Ref: AttestationStatementโ€“Part 2.911(d)(7)filing FCCID:2BDZT-UBX01 ChengduLelianZhichuangTechnologyCo.,Ltd(โ€œtheapplicantโ€)certifiesthat,asofthedateofthe filingoftheapplication,[LOBOSIOWAINC](โ€œtheagentโ€)isourdesignatedU.S.agentforserviceof processfortheabovereferenceFCCID.Theapplicantacceptstomaintainanagentforserviceof processintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolvingtheequipment, whicheverislater.TheapplicantfurtheracknowledgesitisourresponsibilitytoinformtheFCC whenevertheagentinformationchanges. [LOBOSIOWAINC]("theagent)understanditistheagent'sobligationtoacceptserviceofprocess intheUnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddress. DesignatedU.S.Agent CompanyName:LOBOSIOWAINC FRN:0036413961 Address:4623BittercreekDrColoradoSpringsco 80922Us Signature: ContactPerson:HarleyLi Tel:(818)818-0538Email:[email protected] Applicant CompanyName:ChengduLelianZhichuangTechnologyCo.,Ltd FRN:0038354379 Address:No.202,floor2,building1,No.1288, HuandaoRoad,hightechZone,Chengdu,Sichuan ProvinceChina Signature: ContactPerson:ChenXiaoLin Tel:17780586225Email:[email protected]

Cover Letter(s)

ChengduLelianZhichuangTechnologyCo.,Ltd Date๏ผš8-25-2026 ProductModelNumber:UltraBARX FCCID ๏ผš 2BDZT-UBX01 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: ๏‚ทTesting ๏‚ทApprovalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By:ChenXiaoLin ContactListedonFCCWesbite (Applicantsignature) Title:Manager Email:[email protected] Telephone:17780586225 Onbehalfof:ChengduLelianZhichuangTechnologyCo.,Ltd.

Cover Letter(s)

ChengduLelianZhichuangTechnologyCo.,Ltd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:August27,2026 Subject;RequestforConfidentiality FCCID: 2BDZT-UBX01 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommissionโ€™srulesTitle47Sectionsยง0.457andยง0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFRยง2.803andtheimportationrulesinTitle47CFRยง2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name: ChenXiaoLin Title: Manager

Cover Letter(s)

ChengduLelianZhichuangTechnologyCo.,Ltd ProductSimilarityDeclaration EUTDescription:UltraBARX ModelNo.:UBX01 SeriesModel:UBX02,UBX03,UBX04,UBX05,CB01,CB02,CB03,CB04, CB05,VC01,VC02,VC03,VC04,VC05,SC01,SC02,SC03, SC04,SC05,DK01,DK02,DK03,DK04,DK05,KK01,KK02, KK03,KK04,KK05,FK01,FK02,FK03,FK04,FK05 We(ChengduLelianZhichuangTechnologyCo.,Ltd)hereby statethatallthemodelsareelectricalidenticalincludingthesame softwareparameterandhardwaredesign(i.e.,circuitdesign,PCB Layout,RFmodule/circuit,antennatype(s)andantennalocation, componentsonPCB,etc.,),samemechanicalstructureand design(includingproductenclosure,materials,etc.,),theonly differenceisthemodelnameandcolour. Signature: Name:ChenXiaoLin Title:QualityManager Place,date:Aug.25,2026

External Photos

Page1of5ReportNo.:FCS202607303 Externalphotos Photo1 Photo2 Page2of5ReportNo.:FCS202607303 Photo3 Photo4 Page3of5ReportNo.:FCS202607303 Photo5 Photo6 Page4of5ReportNo.:FCS202607303 Photo7 Photo8

ID Label/Location Info

LabelandLabelLocation FCCID:2BDZT-UBX01 Thisdevicecomplieswithpart15oftheFCCRules. Operationissubjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)thisdevicemustacceptanyinterferencereceived, includinginterferencethatmaycauseundesired operation. L*W:3cm*2cm labelandWhitefont

Internal Photos

Page1of3ReportNo.:FCS202607303 Internalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202607303 Photo3 Photo4 WiFiANT Page3of3ReportNo.:FCS202607303 Photo5 BluetoothANT Photo6 Page4of3ReportNo.:FCS202607303 Photo7 Photo8 Page5of3ReportNo.:FCS202607303 Photo9

RF Exposure Info

Page 1 of 2 ReportNo.:FCS202607303H01 FCCRFExposure EUTDescription:UltraBARX ModelNo.:UBX01,UBX02,UBX03,UBX04,UBX05,CB01,CB02,CB03,CB04,CB05,VC01,VC02, VC03,VC04,VC05,SC01,SC02,SC03,SC04,SC05,DK01,DK02,DK03,DK04,DK05, KK01,KK02,KK03,KK04,KK05,FK01,FK02,FK03,FK04,FK05 FCCID:2BDZT-UBX01 Equipmenttype:mobileequipment RFExposureEvaluation Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhuman exposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequencyrange (MHz) Electricfield strength (V/m) Magneticfieldstrength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3โ€“3.06141.63*(100)6 3.0โ€“30 1842/f4.89/f *(900/f 2 ) 6 30โ€“30061.40.1631.06 300โ€“1500f/3006 1500โ€“100,000 5 6 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3โ€“1.346141.63*(100)30 1.34โ€“30 824/f2.19/f *(180/f 2 ) 30 30โ€“30027.50.0730.230 300โ€“1500f/150030 1500โ€“100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennain mW;G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthetotalpower inputtotheantenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitis reached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. No.FCS202607303H01 1.TestResultofRFExposureEvaluation BT Frequency(MHz) Output power(dBm) Maxtune- up(mW) Min. distance(cm) Calc. thresholds LimitResult 2402 3.05 2.0184 20.00 0.00071 1.0000Pass 2441 3.39 2.182720.000.000771.0000Pass 2480 3.42 2.1979 20.00 0.00078 1.0000Pass BLE Frequency(MHz) Output power(dBm) Maxtune- up(mW) Min. distance(cm) Calc. thresholds LimitResult 2402 2.64 1.8365 20.00 0.00065 1.0000Pass 2440 2.56 1.8030 20.00 0.00064 1.0000Pass 2480 2.90 1.949820.000.000691.0000Pass WiFi TestModel Conductedp ower (dBm)๏ผ‰ Maxtune- up(mW Min. distance(cm) Calc. thresholds LimitResult 802.11b9.258.414020.000.002981.0000Pass 802.11g9.148.203520.000.002901.0000Pass 802.11n209.298.491820.000.003001.0000Pass BT+WIFI MAX PowerDensity (S) (mW/cm2) Bluetooth MAX PowerDensity (S) (mW/cm2) WiFi TotalRatio LimitResult 0.000780.003000.003781Pass Conclusion:NoSARisrequired

Test Report

One-stopcommunicationRFantennasolutionserviceprovider 1 ShenzhenAnweiWirelessTechonlogyCo.Ltd APPROVALSHEET CustomerAIKSTechnologySpecsCorbar PartNumber AW006-Corbar-021-A0 AW006-Corbar-022-A0 FrequencyBand WIFIAntenna BTAntenna ColorblackEditionREV:A0 SalespersonzhulixinDesignsonghang StructureQINYUNLINConfirmsongweibing Date2026/06/18SigningDate2026/06/18 Address: 2nd Floor, East Building, Building 5, Yifenghua Industrial Park, Huaning Road, Company: Shenzhen Anwei Wireless Technology Co., Ltd. Dalang Subdistrict, Longhua District, Shenzhen, Guangdong Province, China Antenna Type:FPC Antenna One-stopcommunicationRFantennasolutionserviceprovider 2 CONTENTS ไธ€ใ€Productspecifications ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 ไบŒใ€Electricalperformance ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 1.Specificationsandstandards ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 2.Antennamatchingcircuit ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 ไธ‰ใ€Parametertesting ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 1.Testsetup ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 2.Testresults ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 ๅ››ใ€Activetestsetup ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4-6 1.Thetestsite ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 2.Testresults ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5--6 3.Antennaassemblymethod ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 ไบ”ใ€Recommendationsandconclusions ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 ๅ…ญใ€Structuraldrawings ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8-10 One-stopcommunicationRFantennasolutionserviceprovider 3 ไธ€ใ€Productspecifications ThereportmainlyprovidestheparametertestofCorbarWIFI/BTantennaperformance. ไบŒใ€Electricalperformance 1.Specificationsandstandards Thebond-matrix-2.0antennaoperatesinthefrequencybandof2400-2480MHZ /5100-5800MHZ,whereresonanceoccursinthisband.ใ€‚ 2Antennamatchingcircuit Nochangesmade Antennastructure:FPC+coaxialcable One-stopcommunicationRFantennasolutionserviceprovider 4 ไธ‰ใ€Parametertesting 1.Testsetup VSWRThetestdeviceisconnectedinsequenceasfollows:๏ผš E5071BNetworkanalyzerโ†’50ohmcoaxialCableโ†’110mmlongcoppertubeโ†’Testfixture Handlingoftestfixtures๏ผš ASMA-Jconnectorispulledoutfromthe50-ohmtestpointoftheantennaonthe mobilephonePCBwithahardcable,connectedtothecoppertubewithachoke,and thenconnectedtootherdevicesinturn. 2.Testresults Everythingisnormalใ€‚ ๅ››ใ€Activetestsetup Theactivetestdeviceisconnectedinsequenceasfollows: Agilent8960โ†’50ohmcoaxialCableโ†’SatimoSG16testsystemโ†’Mobilephonetobetested 1.Thetestsite AWmicrowaveanechoicchamber:Thetestfrequencyrangeis400MHz-6GHz,the quietzoneis40cmindiameter,andthereflectivityislessthan-90dB. 2.Testresults One-stopcommunicationRFantennasolutionserviceprovider 5 Themaximumradiationpowerandmaximumreceptionsensitivityreflectthe maximumpowerradiationvalueandthebestreceptionperformanceofthe antennaintheentireradiationspace.TRPandTISreflecttheaverage radiationpowerandaveragereceptionsensitivityoftheantenna,thatis,the overallreceptionperformanceoftheantennaใ€‚ ThefollowingistheresultoftheCorbarActicetesting๏ผš One-stopcommunicationRFantennasolutionserviceprovider 6 followingistheresultoftheCorbarpassivetesting๏ผš Antennaassemblymethod๏ผš One-stopcommunicationRFantennasolutionserviceprovider 7 ไบ”ใ€Recommendationsandconclusions Thisreportisbasedontheantennaelectricalperformancemeasuredbythe machineprovidedbythecustomer,pleasereviewitcarefully.ใ€‚ ๅ…ญใ€Structuraldrawings AsshowninFigurebelow One-stopcommunicationRFantennasolutionserviceprovider 8 One-stopcommunicationRFantennasolutionserviceprovider 9 One-stopcommunicationRFantennasolutionserviceprovider 10 JoinHandsToCreateTheFuture

Test Report

FCCTestReport ReportNo:FCS202607303W02 Issuedfor Applicant:ChengduLelianZhichuangTechnologyCo.,Ltd Address: No.202,floor2,building1,No.1288,HuandaoRoad,high techZone,Chengdu,SichuanProvinceChina ProductName:UltraBARX BrandName:N/A ModelName:UBX01 SeriesModel: UBX02,UBX03,UBX04,UBX05,CB01,CB02,CB03,CB04, CB05,VC01,VC02,VC03,VC04,VC05,SC01,SC02,SC03, SC04,SC05,DK01,DK02,DK03,DK04,DK05,KK01,KK02, KK03,KK04,KK05,FK01,FK02,FK03,FK04,FK05 FCCID:2BDZT-UBX01 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:0769-27280901Fax:0769-27280901http://www.FCS-lab.com Page 2 of35ReportNo.:FCS202607303W02 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:0769-27280901Fax:0769-27280901http://www.FCS-lab.com TESTRESULTCERTIFICATION Applicantโ€™sName ...................... : ChengduLelianZhichuangTechnologyCo.,Ltd Address......................................: No.202,floor2,building1,No.1288,HuandaoRoad,high techZone,Chengdu,SichuanProvinceChina Manufacture'sName................: ChengduLelianZhichuangTechnologyCo.,Ltd Address ...................................... : No.202,floor2,building1,No.1288,HuandaoRoad,high techZone,Chengdu,SichuanProvinceChina ProductDescription ProductName...........................: UltraBARX BrandName...............................: N/A ModelName .............................. : UBX01 SeriesModel..............................: Seethefirstpageofthereport TestStandards .......................... :FCCRulesandRegulationsPart15SubpartC,Section247 TestProcedure .......................... : ANSIC63.10-2020+Cor.1-2023+C63.10a-2024+Erratato C63.10a-2024 ThisdevicedescribedabovehasbeentestedbyFluxComplianceServiceLaboratory,thetestresults showthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditis applicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFluxCompliance ServiceLaboratory,thisdocumentmaybealteredorrevisedbyFluxComplianceServiceLaboratory, personalonly,andshallbenotedintherevisionofthedocument.. DateofTest ................................... : Date(s)ofperformanceoftests.:Jul.212026~Aug.062026 DateofIssue ................................. :Aug.062026 TestResult ..................................... :Pass Testedby: (orangeOuYang) Reviewedby : (Jayden) Approvedby: ( JackWang ) Page 3 of35ReportNo.:FCS202607303W02 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:0769-27280901Fax:0769-27280901http://www.FCS-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS..............................................................................................6 1.1TESTFACTORY................................................................................................................7 1.2MEASUREMENTUNCERTAINTY.....................................................................................7 2.GENERALINFORMATION.......................................................................................................8 2.1GENERALDESCRIPTIONOFTHEEUT..........................................................................8 2.2BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED.............10 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS.................11 2.4EQUIPMENTSLIST.........................................................................................................12 3.CONDUCTEDEMISSIONMEASUREMENT.........................................................................13 4.6DBBANDWIDTH..................................................................................................................17 4.1Limit..................................................................................................................................17 4.2TestProcedure.................................................................................................................17 4.3Testsetup.........................................................................................................................17 4.4Testresults.......................................................................................................................18 4.5OriginalTestData.............................................................................................................18 5.CONDUCTEDOUTPUTPOWER...........................................................................................20 5.1LIMIT................................................................................................................................20 5.2TESTPROCEDURE........................................................................................................20 5.3TESTSETUP...................................................................................................................20 5.5TESTRESULTS...............................................................................................................20 6.BANDEDGEANDSPURIOUS(CONDUCTED)....................................................................21 6.1LIMIT................................................................................................................................21 6.2TESTPROCEDURE........................................................................................................21 6.3TESTSETUP...................................................................................................................21 6.4TESTRESULTS...............................................................................................................22 6.5Originaltestdata..............................................................................................................22 7.POWERSPECTRALDENSITY..............................................................................................24 โ€ฆ

Text truncated - open the document above for the full version.

Test Report

FCCTestReport ReportNo:FCS202607303W03 Issuedfor Applicant:ChengduLelianZhichuangTechnologyCo.,Ltd Address: No.202,floor2,building1,No.1288,HuandaoRoad,high techZone,Chengdu,SichuanProvinceChina ProductName:UltraBARX BrandName:N/A ModelName:UBX01 SeriesModel: UBX02,UBX03,UBX04,UBX05,CB01,CB02,CB03,CB04, CB05,VC01,VC02,VC03,VC04,VC05,SC01,SC02,SC03, SC04,SC05,DK01,DK02,DK03,DK04,DK05,KK01,KK02, KK03,KK04,KK05,FK01,FK02,FK03,FK04,FK05 FCCID: 2BDZT-UBX01 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com Page2of52ReportNo.:FCS202607303W03 TESTRESULTCERTIFICATION Applicantโ€™sName ...................... : ChengduLelianZhichuangTechnologyCo.,Ltd Address......................................: No.202,floor2,building1,No.1288,HuandaoRoad,high techZone,Chengdu,SichuanProvinceChina Manufacture'sName................: ChengduLelianZhichuangTechnologyCo.,Ltd Address......................................: No.202,floor2,building1,No.1288,HuandaoRoad,high techZone,Chengdu,SichuanProvinceChina ProductDescription ProductName ........................... : UltraBARX BrandName ............................. : N/A ModelName .............................. : UBX01 SeriesModel..............................: Seethefirstpageofthereport TestStandards .......................... :FCCRulesandRegulationsPart15SubpartC,Section247 TestProcedure .......................... : ANSIC63.10-2020+Cor.1-2023+C63.10a-2024+Erratato C63.10a-2024 ThisdevicedescribedabovehasbeentestedbyFluxComplianceServiceLaboratory,thetestresults showthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditis applicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFluxCompliance ServiceLaboratory,thisdocumentmaybealteredorrevisedbyFluxComplianceServiceLaboratory, personalonly,andshallbenotedintherevisionofthedocument.. DateofTest..................................: Date(s)ofperformanceoftests.:Jul.212026~Aug.062026 DateofIssue ................................. :Aug.062026 TestResult ..................................... :Pass Testedby: (orangeOuYang) Reviewedby : (jayden) Approvedby: (JackWang) FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com Page3of52ReportNo.:FCS202607303W03 TableofContentsPage 1.SUMMARYOFTESTRESULTS..............................................................................................6 1.1TESTFACTORY................................................................................................................7 1.2MEASUREMENTUNCERTAINTY.....................................................................................7 2.GENERALINFORMATION.......................................................................................................8 2.1GENERALDESCRIPTIONOFTHEEUT..........................................................................8 2.2BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED.............10 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS.................11 2.4EQUIPMENTSLIST.........................................................................................................12 3.6DBBANDWIDTH..................................................................................................................13 3.1Limit..................................................................................................................................13 3.2TestProcedure.................................................................................................................13 3.3Testsetup.........................................................................................................................13 3.4Testresults.......................................................................................................................14 4.CONDUCTEDOUTPUTPOWER...........................................................................................20 4.1limit...................................................................................................................................20 4.2testprocedure..................................................................................................................20 4.3TESTSETUP...................................................................................................................20 4.5testresults........................................................................................................................20 5.POWERSPECTRALDENSITY..............................................................................................21 5.1LIMIT................................................................................................................................21 5.2TESTPROCEDURE........................................................................................................21 5.3TESTSETUP...................................................................................................................21 5.4TESTRESULTS...............................................................................................................22 5.5originaltestdata...............................................................................................................23 6.Bandedgeandspurious(conducted).................................................................................28 6.1LIMIT................................................................................................................................28 6.2TESTPROCEDURE............................................................โ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Page1of2 ReportNo.:FCS202607303 RE๏ผˆBelow1GHz๏ผ‰ RE๏ผˆAbove1GHz๏ผ‰ Page2of2 ReportNo.:FCS202607303 CE

Contact Information

Applicant

Chen XiaoLin(Manager)
[email protected]Fax: 17780586225

Technical Contact

LOBOS IOWA INCHarley Li Li
[email protected]

4623 Bittercreek Dr Colorado Springs co 80922 Us ยท United States

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.94 mW
215C2.41 GHz - 2.46 GHz8.49 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Chengdu Lelian Zhichuang Technology Co., Ltd

Astrion Remote Control - FCC ID 2BDZT-HA100 - Chengdu Lelian Zhichuang Technology Co., Ltd
2BDZT-HA100

Astrion Remote Control

Jun 18, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter