Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jul 13, 2026
Application Purpose
Original Equipment
Equipment Note
RED LIGHT THERAPY REMOTE CONTROL
Frequency Range
433.92000000 - 433.92000000
Company
YOUNGY HEALTH CO.,LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User manual RED LIGHT THERAPY BW-RJ-Y01 1. Product appearance 2. Technical Specifications Technical Specifications Model YG60 YG300 LED Type 3W LED 3W LED LED QTY 60pcs 300pcs LED power 180w 900w Wavelength(nm) 660/850 630/660/810/830/850 Beam Angle 30 degree 30 degree Timer Control 1-30mins 1-30mins Technical Specifications Model YG60 YG300 Cooling Fans Quantity 2 pc 4 pcs Product size 400*170*60mm 910*298*60mm EMF Emission 0μT @ 3inches 0μT @ 3inches Sound(dB)@15cm 52 DB 52 DB Flicker No Flicker No Flicker Input voltage AC 110-240V 50/60Hz AC 110-240V 50/60Hz Working Temperature –20°C to 6 0 °C –20°C to 6 0 °C Life Span 50000 hours 50000 hours Warranty 2 Years 2 Years 3.Operation Instructions 3.1 Control Panel Operation(YG60)  Rock the switch labeled RED or NIR to the "I" position to activate the respective light; rock to the "O" position to deactivate it. The RED and NIR light modules may be used individually or in combination. 3.2 Control Panel Operation(YG300)  Press the touch screen icon "RED" to start red light, press again to turn it off;  Press the touch screen icon "NIR" to start near infrared light, press again to turn it off;  Press the "TIME+" to increase time;  Press the "TIME-" to reduce time; 3.3 Remote Control Note(YG300)  Press the ON/OFF button to turn the device on or off;  Press the ALL area of the top-left button to start both the RED and NIR lights simultaneously;  Press the cycle icon area of the top-left button to toggle between the individual RED light and NIR light;  Press the TIME+ button to increase time;  Press the TIME- button to reduce time;  The remote control is rechargeable via USB Type-C interface. No batteries are required; simply connect it to a USB Type-C charger for charging. 4.Accessories included Rolling Base X1 (YG60 model not include) Remote controller X1 (YG60 model not include) 5. Product features  This kind of light penetrates deep into your skin, working wonders on improving the clarity and tone. It's not just surface-level – it goes deep into the bones and muscles, making it excellent for boosting elastin and collagen production. Red Light at 630 nm 660 nm Most of red light absorbed by your skin,leading to increase collagen production and optimal skin health Near Infrared light at 810 nm 830 nm 850 nm Near Infrared light penetrates deeper within your body-enhancing muscle recovery and reducing joint pain 6. How to use it 1.Distance: Apply the light from 3-60 CM to the body. 2.Session Time: Exposure each area for 5-30 minutes, depending on distance, Repeat on other areas if desired 3.Frequency: Do this 2 times to 14 times a week until results are felt. 4,Maintenance: Continue using several times a week. 7. Tips  This light is for indoor use only. and please do not use in the wet environment.  Please cut off the power when stop working.  Please do not place it near any heat source. 8. Can this hurt my eyes? The typical human eye responds to wavelengths 400nm to 700nm. The light coming from this device is either visible red/blue or invisible infrared.  Infrared light is beneficial to the eyes, just as it is elsewhere on the body. Safety goggles are not necessary to use with infrared.  Red light is bright and can be uncomfortable to use directly on the eyes. Closing your eyes is usually enough to use red light directly on the face. 8. CAUTION AND WARNING  Avoid prolonged exposure of the product to high temperatures and high humidity.  Ensure that lamps are used at the specified voltage and frequency.  Refrain from polishing the metal parts of the lamps with a powder polisher. Instead, use a dry cloth or duster to clean any dust accumulated behind the lamps. This cleaning routine is recommended once a week. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure statement The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Attestation Statements

YOUNGY HEALTH CO.,LTD Covered Equipment Certification Attestation Letter 7/7/2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2BE2A-BWRJY01 YOUNGY HEALTH CO.,LTD (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. YOUNGY HEALTH CO.,LTD (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. YOUNGY HEALTH CO.,LTD (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). <Signature>: Name: Hailong Li Title: Manager Company: YOUNGY HEALTH CO.,LTD Date: 7/7/2026

Attestation Statements

YOUNGY HEALTH CO.,LTD * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 7/7/2026 TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTN.: Reviewing Engineer FCC ID: 2BE2A-BWRJY01 FRN of applicant: 0034942458 Per section 2.911(d)(7) of the FCC rules, [YOUNGY HEALTH CO.,LTD] (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Herland International Trading Inc FCC Registration Number (FRN): 0036324101 Physical U.S. Company Address: 1370 Valley Vista Dr Ste 200 Diamond Bar California 91765- 3921 Contact Person: Jianfeng Gao Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Signed: Printed name: Hailong Li Title: Manager Company Name: YOUNGY HEALTH CO.,LTD Date: 7/7/2026 Agent Signed (if different from Applicant): Signed: Printed name: Jianfeng Gao Title: Manager Company Name: Herland International Trading Inc Date: 7/7/2026

Cover Letter(s)

YOUNGY HEALTH CO.,LTD 2026-07-07 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen DL Testing Technology Co., Ltd.(101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China)to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with YOUNGY HEALTH CO.,LTD(No.34, Hehuan Road,High-Tech Development Zone, Hefei, Anhui, China) <Signature>: Name: Hailong Li Title: Manager Company: YOUNGY HEALTH CO.,LTD

Cover Letter(s)

YOUNGY HEALTH CO.,LTD 2026-07-07 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Compliance Testing, LLC to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). Sincerely, <Signature>: Name: Hailong Li Title: Manager Company: YOUNGY HEALTH CO.,LTD

Cover Letter(s)

YOUNGY HEALTH CO.,LTD 2026-07-07 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2BE2A-BWRJY01 Product Name: RED LIGHT THERAPY REMOTE CONTROL Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...)  Schematics  Block diagram  Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name: Hailong Li Title: Manager Company: YOUNGY HEALTH CO.,LTD

External Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(External Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※

ID Label/Location Info

Size:32*28mm M/N: BW-RJ-Y01 FCC ID: 2BE2A-BWRJY01 Label location

Internal Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(Internal Photos) Shenzhen DL Testing Technology Co., Ltd. ANT Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※

RF Exposure Info

FCC ID: 2BE2A-BWRJY01 RF Exposure Evaluation According to KDB 447498 D01 V06 and part 2.1093,Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f (GHz) ] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where f (GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison EIRP=E Meas +20log(d Meas )-104.7 EIRP is the equivalent isotropically radiated power, in dBm E Meas is the field strength of the emission at the measurement distance, in dBμV/m d Meas is the measurement distance, in m Here, Field strength (dBuV/m) EIRP (dBm) Max tune-up (mW) Frequency (MHz) Min. distance(mm) Calc. thresholds limit 61.53 -33.63 0.0004 433.92 5 0.00006 3.0 So a SAR test is not required

Test Report

Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260527050R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 27 FCC Part 15C Test Report FCC ID: 2BE2A-BWRJY01 Applicant: YOUNGY HEALTH CO.,LTD Address: No.34, Hehuan Road,High-Tech Development Zone, Hefei, Anhui, China Manufacturer: YOUNGY HEALTH CO.,LTD Address: No.34, Hehuan Road,High-Tech Development Zone, Hefei, Anhui, China Product Name: RED LIGHT THERAPY REMOTE CONTROL Trade Mark: N/A Model Number: BW-RJ-Y01, YG-MINI, YG-MINI2, YG180, YG936 Date of Receipt: May. 27, 2026 Test Date: May. 27, 2026 - Jun. 10, 2026 Date of Report: Jun. 10, 2026 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China Applicable Standards: FCC PART 15 C 15.231 ANSI C63.10:2020 Test Result: Pass Report Number: DLE-260527050R Prepared (Test Engineer): Alisa Song Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260527050R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 27 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 4 1.1 MEASUREMENT UNCERTAINTY 4 2 . GENERAL INFORMATION 5 2.1 GENERAL DESCRIPTION OF EUT 5 2.2 DESCRIPTION OF TEST MODES 5 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 6 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 6 2.5 TABLE OF PARAMETERS OF TEST SOFTWARE SETTING 6 2.6 EQUIPMENTS LIST FOR ALL TEST ITEMS 7 3 . EMC EMISSION TEST 8 3.1 CONDUCTED EMISSION MEASUREMENT 8 3.1.1 POWER LINE CONDUCTED EMISSION LIMITS 8 3.1.2 TEST PROCEDURE 8 3.1.3 DEVIATION FROM TEST STANDARD 8 3.1.4 TEST SETUP 9 3.1.5 EUT OPERATING CONDITIONS 9 3.1.6 TEST RESULTS 9 3.2 RADIATED EMISSION MEASUREMENT 12 3.2.1 RADIATED EMISSION LIMITS 12 3.2.2 TEST PROCEDURE 13 3.2.3 DEVIATION FROM TEST STANDARD 13 3.2.4 TEST SETUP 14 3.2.5 EUT OPERATING CONDITIONS 15 3.2.6 TEST RESULTS (BETWEEN 9KHZ – 30 MHZ) 16 3.2.7 TEST RESULTS (BETWEEN 30MHZ – 1GHZ) 17 3.2.8 TEST RESULTS (1GHZ~25GHZ) 20 4 . BANDWIDTH TEST 21 4.1 APPLIED PROCEDURES / LIMIT 21 4.1.1 TEST PROCEDURE 21 4.1.2 DEVIATION FROM STANDARD 21 4.1.3 TEST SETUP 21 4.1.4 EUT OPERATION CONDITIONS 21 4.1.5 TEST RESULTS 22 5 . CALCULATION OF AVERAGE FACTOR 23 5.1 APPLIED PROCEDURES / LIMIT 23 5.1.1 TEST PROCEDURE 23 5.1.2 TEST SETUP 23 5.1.3 EUT OPERATION CONDITIONS 23 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260527050R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 27 Table of Contents Page 5.1.4 TEST RESULTS 24 6 . TRANSMISSION CEASE TIME 25 6.1 APPLIED PROCEDURES / LIMIT 25 6.1.1 TEST PROCEDURE 25 6.1.2 DEVIATION FROM STANDARD 25 6.1.3 TEST SETUP 25 6.1.4 EUT OPERATION CONDITIONS 25 6.1.5 TEST RESULTS 26 7 . ANTENNA REQUIREMENT 27 7.1 STANDARD REQUIREMENT 27 7.2 EUT ANTENNA 27 8 . TEST SEUUP PHOTO 27 9 . EUT PHOTO 27 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260527050R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 27 1.. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.231) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS 15.209,15.231b Fundamental &Radiated Spurious Emission Measurement PASS 15.231a Transmission cease time PASS 15.215 20dB Bandwidth PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Test lab: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China FCC Test Firm Registration Number: 854456 Designation Number: CN1307 IC Registered No.: 27485 CAB ID.: CN0118 1.1. MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Conducted Emission Test ±2.56dB 2 RF power,conducted ±0.42dB 3 Spurious emissions,conducted ±2.76dB 4 All emissions,radiated(<1G) ±3.65dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% 8 20dB Bandwidth ±0.2MHz Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260527050R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 27 2.. GENERAL INFORMATION 2.1. GENERAL DESCRIPTION OF EUT Product Name: RED LIGHT THERAPY REMOTE CONTROL Trade Mark: N/A Model Number: BW-RJ-Y01, YG-MINI, YG-MINI2, YG180, YG936 Test Model: BW-RJ-Y01 Model Difference All models are same as the samples except model name and appearance color, they have the same structure and circuit. Operation Frequency: 433.92MHz Channel numbers: 1 Channels Modulation technology: ASK Antenna Type: Internal Antenna Antenna gain: 1.5dBi Power supply: DC 3.7V from battery DC 5V from type-c Note: 1.For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2.The EUT’s all information provided by client. 2.2. DESCRIPTION OF TEST MODES Note: (1) New battery is used during the test. (2) The test was conducted by pressing the middle button of the product. To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was ev…

Text truncated - open the document above for the full version.

Test Report

ShenzhenYuanDongliDigitalTechnologyCo.,Ltd. Address:3F,BuildingA,RuixingSciencePark,No.6SanheRoad,DalangPeakCommunity,LonghuaDistrict,Shenzhen Phone:86-755-8326-6570Fax:86-755-83255400 1 BluetoothAntennaSampleAcknowledgement BTAntennaProductApproval Time:2020-12-4 1.IntroductiontoAntennas OurBluetoothantennaisdirectlyfabricatedonaPCBboardusingacopper-solderedandtin-plated process.ThecopperfoilthicknessisH/HOZ,andtheboardismadeofFR-4materialwitha1.0mm thickness. She nz hen Yua n Dong li DigitalTechnologyCo ., Ltd. Address:3F, BuildingA, RuixingSciencePark, No.6 SanheRoad, DalangPeak Community,Longhua District,Shenzhen Phone:86-755-8326-6570Fax: 86-755-83255400 2 II . Antenna Shape 1. Dimension diagram: mm ShenzhenYuanDongliDigitalTechnologyCo.,Ltd. Address:3F,BuildingA,RuixingSciencePark,No.6SanheRoad,DalangPeakCommunity,LonghuaDistrict,Shenzhen Phone:86-755-8326-6570Fax:86-755-83255400 3 III.AntennaParameters Antennacenterfrequency:433MHz;bandwidth:420-446MHz;gain:1.5dBi(omnidir- ectional),resonatinginthisfrequencyband.Thetablebelowliststheantenna'skeyparameters. 433Mbuilt-inantenna Frequency(MHz)420~446MHz VSWR≤1.92 Impedance50OhmNominal PolarizationVerticalpolarization Powercapacity 1W Gain (Peak)1.5dBi Standingwavebandwidth ≥26MHz Productiveness>25%

Test Setup Photos

Shenzhen DL Testing Technology Co., Ltd. EUT TEST PHOTO Radiated Measurement Photos Shenzhen DL Testing Technology Co., Ltd. Conducted Measurement Photos ※※※※※ END OF REPORT ※※※※※

Contact Information

Applicant

Hailong Li(Manager)
[email protected]Fax: 400-666-1616

Technical Contact

Herland International Trading IncJianfeng Gao
[email protected]

1370 Valley Vista Dr Ste 200 Diamond Bar, CA 91765 · Diamond Bar, California · United States

Test Firm

Shenzhen DL Testing Technology Co., Ltd.Jade Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term
Grant Notes
Power listed is conducted.