FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Shuye Technology Co.,Ltd./
  3. 2BE2Y-LFHDSW4

2BE2Y-LFHDSW4Hair Dryer

Shenzhen Shuye Technology Co.,Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 03, 2026
Application Purpose
Original Equipment
Equipment Note
Hair Dryer
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Shuye Technology Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Jun 2026

ID Label/Location Info

26.01.28 16.78 mm 33.56 mm D51B ⻛筒镭雕文件 黑雕 深圳术叶创新科技有限公司 2 3 . 2 3 m m 1 3 . 0 6 m m D51B风筒镭雕美规26-05-06

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/2 Report No.: SZCR260500214003 Page: 1 of 9 Keny Xu EMC Laboratory Manager RF EXPOSURE EVALUATION REPORT Application No.: SZCR2605002140HS Applicant: Shenzhen Shuye Technology Co.,Ltd. Address of Applicant: Room1301, Building T7, Qianwan 1st Road No.399, Qianhai Kerry Business Center, Nanshan, Shenzhen, Guangdong, China Manufacturer: Shenzhen Shuye Technology Co.,Ltd. Address of Manufacturer: Room1301, Building T7, Qianwan 1st Road No.399, Qianhai Kerry Business Center, Nanshan, Shenzhen, Guangdong, China Factory: Dongguan Laifen Electronic Technology Co., Ltd. Address of Factory: Room 201. Building 3, No.2 Xinghui Road, Songshanhu Tech Park, Dongguan, Guangdong, China Equipment Under Test (EUT): EUT Name: Hair Dryer Model No.: LFHD SW 4 Trade Mark: FCC ID: 2BE2Y-LFHDSW4 Standard(s) : FCC Rules 47 CFR §2.1093 KDB 447498 D04 interim General RF Exposure Guidance v01 Date of Receipt: 2026-05-19 Date of Evaluation: 2026-05-26 to 2026-06-06 Date of Issue: 2026-06-15 Evaluation Result: Pass* * In the configuration evaluated, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/2 Report No.: SZCR260500214003 Page: 2 of 9 Revision Record Version Chapter Date Modifier Remark 01 2026-06-15 Original Authorized for issue by: Martin Tang/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/2 Report No.: SZCR260500214003 Page: 3 of 9 2 Contents Page 1 Cover Page ................................................................................................................................................ 1 2 Contents .................................................................................................................................................... 3 3 General Information .................................................................................................................................. 4 3.1 General Description of E.U.T. ............................................................................................................ 4 3.2 Details of E.U.T. ................................................................................................................................. 4 3.3 Separation Distance ........................................................................................................................... 4 3.4 Test Location ...................................................................................................................................... 5 3.5 Test Facility ........................................................................................................................................ 5 3.6 Deviation from Standards ................................................................................................................... 5 3.7 Abnormalities from Standard Conditions ........................................................................................... 5 4 FCC Radiofrequency radiation exposure limits .................................................................................... 6 4.1 Blanket 1 mW Blanket Exemption ...................................................................................................... 6 4.2 MPE-based Exemption ...................................................................................................................... 6 4.3 SAR-based Exemption ....................................................................................................................... 7 5 Measurement and Calculation ................................................................................................................. 9 5.1 Maximum transmit power ................................................................................................................... 9 5.2 RF Exposure Calculation ................................................................................................................... 9 6 EUT Constructional Details (EUT Photos) ............................................................................................. 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/2 Report No.: SZCR260500214003 Page: 4 of 9 3 General Information 3.1 General Description of E.U.T. Product Type: Portable device Mobile device Fixed device 3.2 Details of E.U.T. Power supply: AC 110-120V, 60Hz, 1500W Cable(s): AC cable: about 2.5m length, unshielded Operation Frequency: 2402MHz to 2480MHz Bluetooth Version: 5.4 Modulation Type: GFSK Number of Channels: 40 Channel Spacing: 2MHz Antenna Type: ceramic antenna Antenna Gain: 3.12dBi Antenna Number: 1 Remark:The information in this section is provided by the applicant or manufacturer, SGS is not liable to the accuracy, suitability, reliability or/and integrity of the information. 3.3 Separation Distance Minimum test separation distance for head/body: 10mm Minimum test separation distance for limb: 0mm Remark: This minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/2 Report No.: SZCR260500214003 Page: 5 of 9 3.4 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Nanshan District, Shenzhen, Guangdong, China. 518057. Tel: +86 755 2601 2053 Fax: +86 755 2671 0594 No tests were sub-contracted. 3.5 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC St…

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/2 Report No.: SZCR260500214002 Page: 1 of 76 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZCR2605002140HS Applicant: Shenzhen Shuye Technology Co.,Ltd. Address of Applicant: Room1301, Building T7, Qianwan 1st Road No.399, Qianhai Kerry Business Center, Nanshan, Shenzhen, Guangdong, China Manufacturer: Shenzhen Shuye Technology Co.,Ltd. Address of Manufacturer: Room1301, Building T7, Qianwan 1st Road No.399, Qianhai Kerry Business Center, Nanshan, Shenzhen, Guangdong, China Factory: Dongguan Laifen Electronic Technology Co., Ltd. Address of Factory: Room 201. Building 3, No.2 Xinghui Road, Songshanhu Tech Park, Dongguan, Guangdong, China Equipment Under Test (EUT): EUT Name: Hair Dryer Model No.: LFHD SW 4 Trade Mark: FCC ID: 2BE2Y-LFHDSW4 Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2026-05-19 Date of Test: 2026-05-26 to 2026-06-06 Date of Issue: 2026-06-15 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/2 Report No.: SZCR260500214002 Page: 2 of 76 Revision Record Version Chapter Date Modifier Remark 01 2026-06-15 Original Authorized for issue by: Eisen Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/2 Report No.: SZCR260500214002 Page: 3 of 76 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2020) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2020) Section 6.10.5 & 11.12 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2020) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2020) Section 6.6 & 11.12 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Maximum Conducted Output Power ANSI C63.10 (2020) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2020) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectral Density ANSI C63.10 (2020) Section 11.10.3 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2020) Section 6.10.4 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2020) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/2 Report No.: SZCR260500214002 Page: 4 of 76 3 Contents Page 1 Cover Page ................................................................................................................................................ 1 2 Test Summary ........................................................................................................................................... 3 3 Contents .................................................................................................................................................... 4 4 General Information .................................................................................................................................. 6 4.1 Details of E.U.T. ................................................................................................................................. 6 4.2 Description of Support Units .............................................................................................................. 6 4.3 Measurement Uncertainty .................................................................................................................. 7 4.4 Test Location ...................................................................................................................................... 8 4.5 Test Facility ........................................................................................................................................ 8 4.6 Deviation from Standards ................................................................................................................... 8 4.7 Abnormalities from Standard Conditions ........................................................................................... 8 5 Equipment List .......................................................................................................................................... 9 6 Radio Spectrum Technical Requirement ............................................................................................. 12 6.1 Antenna Requirement ...................................................................................................................... 12 6.1.1 Test Requirement: ....................................................................................................................... 12 6.1.2 Conclusion ................................................................................................................................... 12 7 Radio Spectrum Matter Test Results .................................................................................................... 13 7.1 Conducted Emissions at AC Power Line (150kHz-30MHz) ............................................................. 13 7.1.1 E.U.T. Operation .......................................................................................................................... 13 7.1.2 Test Mode Description ................................................................................................................. 13 7.1.3 Test Setup Diagram .....................................…

Text truncated - open the document above for the full version.

Test Report

Page1 of 8 SPECIFICATION Ceramic Antenna 2012 Size 2400-2500 MHz P/N: KCM2012CATR Page2 of 8 1. Frequency 2400-2500 MHz 2. Applications For Miniaturized Bluetooth System 3. Dimensions (Unit : mm) 1). Over View : Page3 of 8 4. Evaluation Board Size and Matching Circuits 5. Electrical Characteristics Part Number Central Frequency 2450 MHz Bandwidth 100(typ.) MHz V.S.W.R ≤2.0 Peak Gain 3.12 dBi Impedance 50 Ohm Polarization Linear Azimuth Beamwidth Omni-directional KCM2012CATR Page4 of 8 6. Return Loss (S11) 7. Radiation Pattern & Efficiency Frequency (MHz) 2400 2450 2500 Efficiency (dB) -2.22 -1.87 -2.08 Efficiency (%) 60 65 62 Gain (dBi) 2.75 3.12 3.01 Page5 of 8 8. Reflow Soldering Standard Condition 9. Packaging and Dimensions  Plastic Tape  Remarks for Package Reserve a length of 150~200mm for the trailer of the carrier and 250~300 mm for the leader of the carrier and further 250mm of cover tape at the leading part of the carrier.   Storage Period Oxidizable Material, 12 months in vacuum sealed bag, please repack within 168 hours by re-seal the package treatment after using. Storage Temperature Range : <30 degree C, Humidity : <60%RH Reserve a length of 150~200mm for the trailer of the carrier and 250~300 mm for the leader of the carrier and further 250mm of cover tape at the leading part of the Material, 12 months in vacuum sealed bag, please repack within 168 seal the package treatment after using. Storage Temperature Range : <30 degree C, Humidity : <60%RH Page6 of 8 Reserve a length of 150~200mm for the trailer of the carrier and 250~300 mm for the leader of the carrier and further 250mm of cover tape at the leading part of the Material, 12 months in vacuum sealed bag, please repack within 168 Reel (6000 pcs/Reel) Page7 of 8 10. Dependability Test Test item Test condition / Test method Specification Solderability IEC 60068-2-58 GB/T2423.28 *Solder bath temperature:240±5°C *Immersion time:2±0.5 sec Solder:Sn96.5Ag3.0Gu0.5 for lead-free. At least 95% of a surface of each terminal electrode must be covered by fresh solder. Leaching (Resistance to dissolution of metallization) JIS C5101 *Solder bath temperature:260±5°C *Leaching immersion time:10±1 sec Solder : Sn96.5 Ag3.0 Gu0.5 for lead-free. Loss of metallization on the edges of each electrode shall not exceed 25%. Resistance to soldering heat IEC 60068-2-58 GB/T2423.28 *Preheating temperature:120~150°C, 1 minute. *Solder temperature:260±5°C *Immersion time:10±1 sec Solder:Sn96.5Ag3.0Gu0.5 for lead-free Measurement to be made after keeping at room temperature for 24±2 hrs. No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics at the room temperature. Loss of metallization on the edges of each electrode shall not exceed 25%. Drop Test IEC 60068-2-32 GB/T2423.8 Customer’s specification. *Height:50 cm *Test Surface: Rigid surface of concrete or *Times:6 surfaces for each units;2 times for No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics at the room temperature. Vibration IEC 60068-2-6 GB/T 2423.10 *Frequency:10Hz~55Hz~10Hz(1min) *Total amplitude:1.5mm *Test times:6hrs.(Two hrs each in three mutually perpendicular directions) No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics at the room temperature. Adhesive Strength of Termination IEC60068-2-21 GB/T 2423.6 *Pressurizing force: 5N(≦0603);10N(>0603) *Test time:10±1 sec No remarkable damage or removal of the termination. Page8 of 8 Bending test IEC 60068-2-21 GB/T 2423.29 The middle part of substrate shall be pressurized by means of the pressurizing rod at a rate of about 1 mm/s per second until the deflection becomes 2mm and then pressure shall be maintained for 10±1 sec. Measurement to be made after keeping at room temperature for 24±2 hours. No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics at the room temperature. Temperature cycle IEC60068-2-14 GB/T 2423.22 30 minutes at-40°C±2°C. 10~15 minutes at room temperature. 30minutes at +85°C±2°C. 10~15 minutes at room temperature. Total 100 continuous cycles Measurement to be made after keeping at room temperature for 24±2 hrs. No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics at High temperature IEC 60068-2-2 GB/T2423.2 *Temperature:85±2°C. *Test duration:500+24/-0 hours. Measurement to be made after keeping at room temperature for 24±2 hrs. No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics. Humidity (steady conditions) IEC60068-2-3 GB/T 2423.3 *Humidity:85±5%R.H. *Temperature:85±2°C. Measurement to be made after keeping at room temperature for 24±2 hrs ※ 200hrs measuring the first data then 300hrs No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics at the room temperature. Low temperature IEC 60068-2-1 GB/T2423.1 *Temperature:-40±2°C. *Test duration:500+24/-0 hours Measurement to be made after keeping at room temperature for 24±2 hrs. No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics at the room temperature.

Contact Information

Applicant

Ji Changyong
[email protected]Fax: 19874740374

Technical Contact

Baihetian Innovative SolutionsKenneth Young
[email protected]

6837 Chase Rd · Dearborn, Michigan, 48126 · United States

Test Firm

SGS-CSTC Standards Technical Services Co., Ltd. ShKeny Xu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.10 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted.

Other Applications from Shenzhen Shuye Technology Co.,Ltd.

Laifen Glowy Vanity Mirror - FCC ID 2BE2Y-LFMMM8 - Shenzhen Shuye Technology Co.,Ltd.
2BE2Y-LFMMM8

Laifen Glowy Vanity Mirror

Jun 18, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2BE2Y-LFWCL

Wireless Charger

Mar 27, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Electric toothbrush - FCC ID 2BE2Y-LFTB02 - Shenzhen Shuye Technology Co.,Ltd.
2BE2Y-LFTB02

Electric toothbrush

Mar 26, 2026

Equipment Class

DTS - Digital Transmission System