FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. DONGGUAN E-TEST TECHNOLOGY CO., LTD./
  3. 2BE44-ET24BLE

2BE44-ET24BLEAutomatic Upper Arm Blood Pressure Monitor

DONGGUAN E-TEST TECHNOLOGY CO., LTD.
Automatic Upper Arm Blood Pressure Monitor - FCC ID 2BE44-ET24BLE - DONGGUAN E-TEST TECHNOLOGY CO., LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 24, 2024
Application Purpose
Original Equipment
Date of Application
Mar 24, 2024
Equipment Note
Automatic Upper Arm Blood Pressure Monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
DONGGUAN E-TEST TECHNOLOGY CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Automatic Upper Arm Blood Pressure Monitor (Model: BA-831X, BA-832X, BA-833X, BA-837X, BA-838X, BA-842X, BA- 843X, BA-845X, BA-847X, BA-849X, BA-851X, BA-852X, BA-855X, BA- 835, BA-836, BA-839, BA-840, BA- 856) User Manual (Version: V1.0) Automatic Upper Arm Blood Pressure Monitor User Manual 2 / 31 This manual is only used to operate this electronic device; the company will not bear the consequences caused by this instruction manual for other purposes and responsibilities. This manual contains proprietary information, protected by copyright, and all rights reserved. Without our prior written consent, it should not be allowed to copy any part of this manual or translation. Considering the needs of the technical improvement or file update, the company reserves the right to revise the content in these operating instructions for correction, and if the change does not involve the sold device safety without prior notice. Due to technical update or the special requirements of users, under the condition of the instrument performance is not affected, the standard of some parts is different with this manual, please pay attention. If your Device is not functioning properly, discontinue using your device and contact a customer service Specialist. Automatic Upper Arm Blood Pressure Monitor User Manual 3 / 31 Content Requirement of Use............................................................................................................4 1.Safety and Regulatory.................................................................................................5 1.1Introduction............................................................................................................5 1.2Contraindications...................................................................................................5 1.3Adverse Reactions.................................................................................................5 1.4Warnings................................................................................................................5 1.5Precautions............................................................................................................6 2.Device Description......................................................................................................7 2.1General description................................................................................................7 2.2Intended for use/Indication for use.........................................................................8 2.3Essential Performance...........................................................................................8 2.4Cybersecurity.........................................................................................................8 2.5Specification...........................................................................................................9 2.6Device Components and Accessories.................................................................10 3.Using Instructions......................................................................................................12 3.1Preparation for use..............................................................................................12 3.2Operation.............................................................................................................14 3.3Measuring Process..............................................................................................15 3.4Memory function..................................................................................................17 3.5Shut down............................................................................................................18 3.6Assessing High Blood Pressure for Adults..........................................................18 3.7Bluetooth function................................................................................................19 4.Cleaning and Maintenance........................................................................................20 4.1Cleaning...............................................................................................................20 4.2Maintenance........................................................................................................21 5.Storage......................................................................................................................21 6.Troubleshooting and Error indicators........................................................................21 6.1Troubleshooting...................................................................................................21 6.2Error indicators.....................................................................................................22 7.Disposal.....................................................................................................................23 8.Label & Symbols.......................................................................................................23 9.ELECTROMAGNETIC COMPATIBILITY (EMC).......................................................24 10.Warranty Card...........................................................................................................31 11.Manufacturer Information..........................................................................................32 Automatic Upper Arm Blood Pressure Monitor User Manual 4 / 31 Requirement of Use Content on this page is indicated that careful attention to the operation steps should be paid when using our devices to avoid abnormal operation and the risk of personal injury. Our company states that users must read the requirement of use before usage and operate the device according to the requirements of use. The company does not bear the duty of safety, reliability and performance guarantee if users do not operate the device as required and use, maintain, store the device according to the manual. I…

Text truncated - open the document above for the full version.

Attestation Statements

Rev1/26/2023 (DONGGUANE-TESTTECHNOLOGYCO.,LTD.) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:03-22-2024 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BE44-ET24BLE [DONGGUANE-TESTTECHNOLOGYCO.,LTD.](“theapplicant”)certifiesthattheequipmentforwhich authorizationissoughtisnot“covered”equipmentprohibitedfromreceivinganequipment authorizationpursuanttosection2.903oftheFCCrules. Sincerely, (Applicantsignature) (VictorWan) Rev1/26/2023 (DONGGUANE-TESTTECHNOLOGYCO.,LTD.) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:03-22-2024 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BE44-ET24BLE [DONGGUANE-TESTTECHNOLOGYCO.,LTD.](“theapplicant”)certifiesthat,asofthedateofthefiling oftheapplication,theapplicantisnotidentifiedontheCoveredList(asaspecificallynamedentityor anyofitssubsidiariesoraffiliates)asanentityproducing“covered” equipment. Sincerely, (Applicantsignature) (VictorWan)

Attestation Statements

DONGGUANE-TESTTECHNOLOGYCO.,LTD. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Date:2024.03.22 SUBJECT:FCCID:2BE44-ET24BLE ToWhomItMayConcern: I,theundersigned,herebystatesthisequipmenthasbeentestedandfoundtocomply withthelimitsforaClassBdigitaldevice,pursuanttopart15oftheFCCRules,and willapplytheSupplier'sDeclarationofConformityproceduretotheclassB computerperipheralportionofthiscompositedevice.IunderstandthefollowingFCC requirements: 1.DevicessubjecttotheSDoCprocedurearerequiredtobetestedtoshow compliancewiththeFCCtechnicalregulationsbyarecognizedaccreditedtesting laboratory.ThetestinglaboratorymustbeaccreditedbyaCommissionapproved accreditationbodyordesignatedunderthetermsofagovernment-to-government MutualRecognitionAgreement(MRA).Alistingofthoseaccreditedtesting laboratoriesthathavebeenrecognizedbytheCommissionispublishedontheFCC Webpage:https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm(Selectthe "accredited"optiontosearchforFCCrecognizedaccreditedtestfirms.) 2.Pt2.1077containsthelistofinformationthatmustbeincludedintheSupplier's DeclarationofConformity,whichmustbesuppliedwitheachproductsold.The SDoCcomplianceinfoshallbeincludedintheUser’sManualorasaseparate sheet.Theinfomustcontainthename,address,andphonenumberofthe responsibleparty,whichmustbelocatedwithintheUnitedStates.Accordingto 2.909(b),theresponsiblepartyiseithertheManufactureroriftheproductis importedtheImporter. Regards, DONGGUANE-TESTTECHNOLOGYCO.,LTD. ------------------------------- ( VictorWan )

Cover Letter(s)

DONGGUANE-TESTTECHNOLOGYCO.,LTD. Rev11/20/07 FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationofFCCID:2BE44-ET24BLE PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName BlockDiagram Schematics OperationalDescription BlockDiagram Schematics OperationalDescription Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateoftheGrant forthisapplication. PursuanttoDA04-1705June15,2004oftheCommission’spublicnotice,Wealsorequestingthe commissiontograntshort-termconfidentialityrequestonthefollowingattachmentsuntil180 daysaftertheGrantDateofEquipmentAuthorizations. ExhibitTypeFileName Sincerely, VictorWan 2024.03.22

Cover Letter(s)

Declarationonmodeldifference Wetheundersignedherebyconfirmthatthesemodelsareidentical,andallmodelshavethesame RFmodule,PCBlayout,Antenna,schematicsandcomponent.Onlydifferentonmodelnameand thecoloroftheproducte. ProductionnameTrademarkFCCModelno. AutomaticUpperArm BloodPressureMonitor N/A2BE44-ET24BLEBA-831X,BA-832X, BA-833X,BA-837X, BA-838X,BA-842X, BA-843X,BA-845X, BA-847X,BA-849X, BA-851X,BA-852X, BA-855X,BA-835,BA-836, BA-839,BA-840,BA-856 Confirmedby: VictorWan DONGGUANE-TESTTECHNOLOGYCO.,LTD. 2024.03.22

Cover Letter(s)

DONGGUANE-TESTTECHNOLOGYCO.,LTD. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Date:2024.03.22 SUBJECT:FCCApplicationforFCCID:2BE44-ET24BLE ToWhomItMayConcern: We,theundersigned,herebyauthorizeSamLv.atEMTEK(DONGGUAN)CO.,LTD.on ourbehalf,toapplytotheFederalCommunicationsCommissiononourequipment.Any andallactscarriedoutbyEMTEK(DONGGUAN)CO.,LTD.onourbehalfshallhave thesameeffectasactsofourown. ThisistoadvisethatweareinfullcompliancewiththeAnti-DrugAbuseAct.We,the applicant,arenotsubjecttoadenialoffederalbenefitspursuanttoSection5301ofthe Anti-DrugActof1988,21USC853a,andnopartytotheapplicationissubjecttoadenial offederalbenefitspursuanttothatsection. Regards, Sincerely, VictorWan 2024.03.22

External Photos

ReportNo.EDG2402040009E001Page1of4Ver.1.0 FCCID:2BE44-ET24BLE ReportNo.EDG2402040009E001Page2of4Ver.1.0 ReportNo.EDG2402040009E001Page3of4Ver.1.0 ReportNo.EDG2402040009E001Page4of4Ver.1.0

Internal Photos

ReportNo.EDG2402040009E001Page1of3Ver.1.0 FCCID:2BE44-ET24BLE ReportNo.EDG2402040009E001Page2of3Ver.1.0 B T A N T ReportNo.EDG2402040009E001Page3of3Ver.1.0

RF Exposure Info

ReportNo.EDG2402040009E00102RPage1of7Ver.1.0 TESTREPORT ProductName:AutomaticUpperArmBloodPressureMonitor ModelNumber : BA-831X,BA-832X,BA-833X,BA-837X, BA-838X,BA-842X,BA-843X,BA-845X, BA-847X,BA-849X,BA-851X,BA-852X, BA-855X,BA-835,BA-836,BA-839,BA-840, BA-856, FCCID:2BE44-ET24BLE Preparedfor:DONGGUANE-TESTTECHNOLOGYCO.,LTD. Address:Room201,301,Building1,ChangpingSectionNo.1, DongshenRoad,ChangpingTown,DongguanCity, Guangdong,China Preparedby:EMTEK(DONGGUAN)CO.,LTD. Address:-1&2/F.,Building2,ZoneA,ZhongdaMarineBiotechnology ResearchandDevelopmentBase,No.9,XinchengAvenue, SongshanhuHigh-technologyIndustrialDevelopmentZone, Dongguan,Guangdong,China TEL:+86-0769-22807078 FAX:+86-0769-22807079 ReportNumber:EDG2402040009E00102R Date(s)ofTests:February19,2024toMarch06,2024 Dateofissue:March06,2024 $ 二维码 $ ReportNo.EDG2402040009E00102RPage2of7Ver.1.0 TableofContents 1.TESTRESULTCERTIFICATION...............................................................................................................................................3 2.EUTSPECIFICATION.................................................................................................................................................................5 3.TESTREQUIREMENT................................................................................................................................................................6 4.MEASUREMENTRESULT.........................................................................................................................................................6 ReportNo.EDG2402040009E00102RPage3of7Ver.1.0 1.TESTRESULTCERTIFICATION Applicant:DONGGUANE-TESTTECHNOLOGYCO.,LTD. Address: Room201,301,Building1,ChangpingSectionNo.1,DongshenRoad, ChangpingTown,DongguanCity,Guangdong,China Manufacturer:DONGGUANE-TESTTECHNOLOGYCO.,LTD. Address: Room201,301,Building1,ChangpingSectionNo.1,DongshenRoad, ChangpingTown,DongguanCity,Guangdong,China EUT:AutomaticUpperArmBloodPressureMonitor ModelName: BA-831X,BA-832X,BA-833X,BA-837X,BA-838X,BA-842X,BA-843X, BA-845X,BA-847X,BA-849X,BA-851X,BA-852X,BA-855X,BA-835,BA-836, BA-839,BA-840,BA-856 Trademark:N/A MeasurementProcedureUsed: APPLICABLESTANDARDS STANDARDTESTRESULT §15.247(i),§2.1093PASS TheaboveequipmentwastestedbyEMTEK(DONGGUAN)CO.,LTD.Thetestdata,dataevaluation,test procedures,andequipmentconfigurationsshowninthisreportweremadeinaccordancewiththeprocedures giveninANSIC63.10(2013)andtheenergyemittedbythesampleEUTtestedasdescribedinthisreportisin compliancewiththerequirementsofFCCRules FCC§15.247(i),§2.1093 . Thetestresultsofthisreportrelateonlytothetestedsampleidentifiedinthisreport DateofTest:February19,2024toMarch06,2024 Preparedby: WarrenDeng/Editor Reviewer: TimDong/Supervisor Approve&AuthorizedSigner: SamLv/Manager ReportNo.EDG2402040009E00102RPage4of7Ver.1.0 ModifiedHistory VersionReportNo.RevisionDateSummary EDG2402040009E00102R/OriginalReport ReportNo.EDG2402040009E00102RPage5of7Ver.1.0 2. EUTSpecification CharacteristicsDescription Product:AutomaticUpperArmBloodPressureMonitor ModelNumber: BA-831X,BA-832X,BA-833X,BA-837X,BA-838X,BA-842X,BA-843X, BA-845X,BA-847X,BA-849X,BA-851X,BA-852X,BA-855X,BA-835, BA-836,BA-839,BA-840,BA-856 Allmodelsarethesameexceptthemodelnameandcolor.Here,BA-831Xis selectedforalltests. Sample:1# DataRate: 1Mbps,2Mbps Modulation: GFSK OperatingFrequency Range(s): 2402-2480MHz NumberofChannels: 40channels TransmitPowerMax: -10.11dBm(0.000097W) AntennaGain:1.13dBi Powersupply: DC6Vfrombattery Evaluationapplied:MPEEvaluation SAREvaluation ReportNo.EDG2402040009E00102RPage6of7Ver.1.0 3. TestRequirement SAREvaluation Accordingto447498D01V06,systemsoperatingundertheprovisionsofthissectionshallbeoperatedina mannerthatensuresthatthepublicisnotexposedtoradiofrequencyenergylevelinexcessofthe Commission’sguidelines. RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,usingmeasurementsorcomputer simulation.WhenroutineSARevaluationisnotrequired,portabletransmitterswithoutputpowergreaterthan theapplicablelowthresholdrequireSARevaluationtoqualityforTCBapproval. OneantennaisavailablefortheEUT.Theminimumseparationdistanceis5mm. ReportNo.EDG2402040009E00102RPage7of7Ver.1.0 4. MeasurementResult Antennagain:1.13dBi Transmit Frequency( MHz) RateMode Measure dPower (dBm) E.I.R.P (dBm) Tune upPower (dBm) Max tune up power (dBm) Calculation Result Calculation threshold(1-g SAR) 2402 1M GFSK-11.44 -10.31-11±1-10 0.03099683 2440GFSK-10.05 -8.92-9±1-8 0.04952383 2480GFSK-10.04 -8.91-9±1-8 0.04991783 2402 2M GFSK-11.55 -10.42-11±1-10 0.03099683 2440GFSK-10.11 -8.98-9±1-8 0.04952383 2480GFSK-10.11 -8.98-9±1-8 0.04991783 AccordingtoKDB447498D01V06,nostand-alonerequiredforBTantenna,andnosimultaneousSAR measurementisrequired. ***EndofReport***

Test Report

Note:PCBantenna Antennaplate Modelname Antennagain Frequecyrange Connectortyp PCB antenna FL-V4 1.13dBi e 2402MHZ- 2480MHZ Direct FL-V4 Antennadescribe ModelFL-V4 Test/Plsition Frequency2402 0 2441 00 -2.28 -1.73 1.74 -4.47 -2.73 0.82 -0.41 0.40 1.64 -0.51 1.13 3.11 -1.13 0.45 2.44 -1.34 1.10 4.98 Front/BackRatio(dB) Beamwidth(°) +Beamwidth(°) -Beamwidth(°) BoresightAngle(°) MaximumPower(dBm) MinimumPower(dBm) AveragePower(dBm) Max/MinRatio(dB) Max/AvgRatio(dB) Min/AvgRatio(dB) AverageGain(dB) 36.00 90.00 39.00 90.00 -2.731.131.10 -4.81 -1.36 5.91 -4.43 7.57 -0.50 4.51 1.701.632.46 -5.87 -4.47 -2.78 -0.51 -3.45 -1.34 NOTE 2DFSGain 2480 41.00 53.00 94.00126.00128.00 10.00240.00235.00 -10.30-3.38 Ant.PortInputPwr.(dBm) Tot.Rad.Pwr.(dBm) PeakEIRP(dBm) Directivity(dBi) Efficiency(dB) Gain(dBi) 深

Test Report

ReportNo.EDG2402040009E001Page1of60Ver.1.0 TESTREPORT ProductName:AutomaticUpperArmBloodPressureMonitor ModelNumber: BA-831X,BA-832X,BA-833X,BA-837X, BA-838X,BA-842X,BA-843X,BA-845X, BA-847X,BA-849X,BA-851X,BA-852X, BA-855X,BA-835,BA-836,BA-839,BA-840, BA-856 FCCID:2BE44-ET24BLE Preparedfor:DONGGUANE-TESTTECHNOLOGYCO.,LTD. Address:Room201,301,Building1,ChangpingSectionNo.1, DongshenRoad,ChangpingTown,DongguanCity, Guangdong,China Preparedby:EMTEK(DONGGUAN)CO.,LTD. Address:-1&2/F.,Building2,ZoneA,ZhongdaMarineBiotechnology ResearchandDevelopmentBase,No.9,XinchengAvenue, SongshanhuHigh-technologyIndustrialDevelopmentZone, Dongguan,Guangdong,China TEL:+86-0769-22807078 FAX:+86-0769-22807079 ReportNumber:EDG2402040009E00101R Date(s)ofTests:February19,2024toMarch06,2024 Dateofissue:March06,2024 $二维码$ ReportNo.EDG2402040009E001Page2of60Ver.1.0 TableofContents 1TESTRESULTCERTIFICATION..................................................................................................................................................3 2EUTTECHNICALDESCRIPTION.................................................................................................................................................5 3SUMMARYOFTESTRESULT.....................................................................................................................................................6 4TESTMETHODOLOGY.................................................................................................................................................................7 4.1GENERALDESCRIPTIONOFAPPLIEDSTANDARDS......................................................................................................7 4.2MEASUREMENTEQUIPMENTUSED..................................................................................................................................7 4.3DESCRIPTIONOFTESTMODES..........................................................................................................................................8 5FACILITIESANDACCREDITATIONS........................................................................................................................................9 5.1FACILITIES..............................................................................................................................................................................9 5.2EQUIPMENT............................................................................................................................................................................9 5.3LABORATORYACCREDITATIONSANDLISTINGS.........................................................................................................9 6TESTSYSTEMUNCERTAINTY.................................................................................................................................................10 7SETUPOFEQUIPMENTUNDERTEST.....................................................................................................................................11 7.1RADIOFREQUENCYTESTSETUP1.................................................................................................................................11 7.2RADIOFREQUENCYTESTSETUP2.................................................................................................................................11 7.3CONDUCTEDEMISSIONTESTSETUP.............................................................................................................................13 7.4BLOCKDIAGRAMCONFIGURATIONOFTESTSYSTEM.............................................................................................14 7.5SUPPORTEQUIPMENT........................................................................................................................................................14 8FREQUENCYHOPPINGSYSTEMREQUIREMENTS...............................................................................................................15 8.1StandardApplicable.................................................................................................................................................................15 8.2EUTPseudorandomFrequencyHoppingSequence................................................................................................................15 8.3EqualHoppingFrequencyUse................................................................................................................................................16 8.4FrequencyHoppingSystem.....................................................................................................................................................16 9TESTREQUIREMENTS...............................................................................................................................................................17 9.1DTS6DBBANDWIDTH........................................................................................................................................................17 9.2DTS99%BANDWIDTH........................................................................................................................................................22 9.3MAXIMUMPEAKCONDUCTEDOUTPUTPOWER.........................................................................................................26 9.4MAXIMUMPOWERSPECTRALDENSITY.......................................................................................................................31 9.5UNWANTEDEMISSIONSINNON-RESTRICTEDFREQUENCYBANDS......................................................................35 9.6RADIATEDSPURIOUSEMISSION.....................................................................................................................................49 CONDUCTEDEMISSIONSTEST..............................................................................................................................................57 9.7ANTENNAAPPLICATION....................................…

Text truncated - open the document above for the full version.

Test Setup Photos

ReportNo.EDG2402040009E001Page1of1Ver.1.0 FCCID:2BE44-ET24BLE

Contact Information

Applicant

Victor Wan(General Manager)
[email protected]+86-0769-81158038Fax: +86-0769-82289331

Test Firm

EMTEK (Dongguan) Co., Ltd.Sam Lv
[email protected]886-0769-22807078

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz97.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.