FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Š 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Muguoke Science and Technology Ltd./
  3. 2BE4W-MGK03

2BE4W-MGK03Prostate massager

Shenzhen Muguoke Science and Technology Ltd.
Prostate massager - FCC ID 2BE4W-MGK03 - Shenzhen Muguoke Science and Technology Ltd.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 16, 2024
Application Purpose
Original Equipment
Date of Application
Mar 16, 2024
Equipment Note
Prostate massager
Frequency Range
433.92000000 - 433.92000000
Company
Shenzhen Muguoke Science and Technology Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: Shenzhen Muguoke Science and Technology Ltd. Address: 806 Juji Science and Technology Building, Yabian Community, Shenzhen, China Phone: +86-13071394350 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-03-11 Signature Date Printed Name of Signee / Title: Shiwen Jia / Manager Company: Shenzhen Muguoke Science and Technology Ltd. Address: 806 Juji Science and Technology Building, Yabian Community, Shenzhen, China Phone: +86-13071394350 Fax: N/A Email: [email protected]

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BE4W-MGK03 MGK03 We, applicant Company Name: Shenzhen Muguoke Science and Technology Ltd. Address: 806 Juji Science and Technology Building, Yabian Community, Shenzhen, China Phone: +86-13071394350 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-03-11 Signature Date Printed Name of Signee / Title: Shiwen Jia / Manager Company: Shenzhen Muguoke Science and Technology Ltd. Address: 806 Juji Science and Technology Building, Yabian Community, Shenzhen, China Phone: +86-13071394350 Fax: N/A Email: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BE4W-MGK03 MGK03 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Parts Lists • the Tune Up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-03-11 Signature Date Printed Name of Signee / Title: Shiwen Jia / Manager Company: Shenzhen Muguoke Science and Technology Ltd. Address: 806 Juji Science and Technology Building, Yabian Community, Shenzhen, China Phone: +86-13071394350 Fax: N/A Email: [email protected]

External Photos

FCCID:2BE4W-MGK03 FCCID:2BE4W-MGK03 FCCID:2BE4W-MGK03 FCCID:2BE4W-MGK03

ID Label/Location Info

FCCID:2BE4W-MGK03 Label Size:10mm*5mm FCCID:2BE4W-MGK03 LabelLocation

Internal Photos

FCCID:2BE4W-MGK03 FCCID:2BE4W-MGK03 ANT

RF Exposure Info

RFExposureevaluation FCCID2BE4W-MGK03 ProductNameProstatemassager Model/TypereferenceMGK03 ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypePortableDevice 1.Reference ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposureto RadioFrequencyElectromagneticFields,3kHzto300GHz. FCCKDBpublication447498D01GeneralRFExposureGuidancev06:MobileandPortable DevicesRFExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1093:Radiofrequencyradiationexposureevaluation:portabledevices 2.Requirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06Section4.3.1Standalone SARtestexclusionconsiderations:“UnlessspecificallyrequiredbythepublishedRFexposure KDBprocedures,standalone1-gheadorbodyand10-gextremitySARevaluationforgeneral populationexposureconditions,bymeasurementornumericalsimulation,isnotrequired whenthecorrespondingSARTestExclusionThresholdcondition,listedbelow,issatisfied. Thesetestexclusionconditionsarebasedonsource-basedtime-averagedmaximum conductedoutputpoweroftheRFchannelrequiringevaluation,adjustedfortune-uptolerance, andtheminimumtestseparationdistancerequiredfortheexposureconditions.22The minimumtestseparationdistanceisdeterminedbythesmallestdistancefromtheantenna andradiatingstructuresoroutersurfaceofthedevice,accordingtothehostformfactor, exposureconditionsandplatformrequirements,toanypartofthebodyorextremityofauser orbystander(see5)ofsection4.1).ToqualifyforSARtestexclusion,thetestseparation distancesappliedmustbefullyexplainedandjustifiedbytheoperatingconfigurationsand exposureconditionsofthetransmitterandapplicablehostplatformrequirements,typicallyin theSARmeasurementorSARanalysisreport,accordingtotherequiredpublishedRF exposureKDBprocedures.WhennootherRFexposuretestingorreportingisrequired,a statementofjustificationandcompliancemustbeincludedintheequipmentapproval,inlieuof theSARreport,toqualifyfortheSARtestexclusion.Whenrequired,thedevicespecific conditionsdescribedintheotherpublishedRFexposureKDBproceduresmustbesatisfied beforeapplyingtheseSARtestexclusionprovisions;forexample,handheldPTTtwo-way radios,handsets,laptops&tabletsetc.23” [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[√f(GHz)]≤3.0for1-gSARand≤7.5for10-gextremitySAR,where: •f(GHz)istheRFchanneltransmitfrequencyinGHz •PoweranddistanceareroundedtothenearestmWandmmbeforecalculation •Theresultisroundedtoonedecimalplaceforcomparison •3.0and7.5arereferredtoasthenumericthresholdsinthestep2below Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≤50 mmandfortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmaccordingto5)insection4.1isappliedto determineSARtestexclusion. Whenoneofthefollowingtestexclusionconditionsissatisfiedforallcombinationsof simultaneoustransmissionconfigurations,furtherequipmentapprovalisnotrequiredto incorporatetransmittermodulesinhostdevicesthatoperateinthemixedmobileandportable hostplatformexposureconditions.Thegranteeisresponsiblefordocumentingthisaccording toClassIpermissivechangerequirements.AntennasthatqualifyforstandaloneSARtest exclusionmustapplytheestimatedstandaloneSARtodeterminesimultaneoustransmission testexclusion. a)The[∑of(thehighestmeasuredorestimatedSARforeachstandaloneantenna configuration,adjustedformaximumtune-uptolerance)/1.6W/kg]+[∑ofMPEratios]is≤ 1.0. b)TheSARtopeaklocationseparationratiosofallsimultaneouslytransmittingantennapairs operatinginportabledeviceexposureconditionsareall≤0.04,andthe[∑ofMPEratios]is ≤1.0. 3.ConductedPeakOutputPower TXfrequencyrange:433.92MHz Devicecategory:Portabledevice(Distance:5mm)Max.FieldStrength:60.60dBuV/m@3m EIRP=E-104.8+20logD=53.63-104.8+20log3=-41.63dBm MaximumConductedOutputPower:-41.63dBm Tune-up:-41±1 4.EvaluationResult Band/Modef(GHz) Antenna Distance (mm) RFoutputpower SARTest Exclusion Threshold SARTest Exclusion dBmmW ASK0.4335-40 0.0001 0.00001<3.0Yes Remark: 1.Outputpowerincludingtuneuptolerance; 2.Whentheminimumtestseparationdistanceis<5mm,adistanceof5mmaccordingtof)in section4.1isappliedtodetermineSARtestexclusion. 5.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1093fortheuncontrolled RFExposureandSARExclusionThresholdperKDB447498v06. ------Endofthereport------

Contact Information

Applicant

shiwen Jia
[email protected]13071394350Fax: 13071394350

Test Firm

Shenzhen Bangce Testing Technology Co. , Ltd.Mike Jin Jin
[email protected]13824315318

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term
Grant Notes
This filing meets the SAR threshold exclusion set forth in KDB 447498 and therefore can be used in mobile/portable configurations. The antenna used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.