FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhejiang ULIRVISION Technology Co., Ltd./
  3. 2BE6SHW0002

2BE6SHW0002Thermal Monocular

Zhejiang ULIRVISION Technology Co., Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 08, 2024
Application Purpose
Original Equipment
Date of Application
Aug 08, 2024
Equipment Note
Thermal Monocular
Frequency Range
2412.00000000 - 2462.00000000
Company
Zhejiang ULIRVISION Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

ZhejiangULIRVISIONTechnologyCo.,Ltd. 8F/9F/10F/17F,BlockC,No.581HuojuAvenue,PuyanStreet,BinjiangDistrict,310000Hangzhou, Zhejiang,China FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date: Jul.15,2024 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BE6SHW0002 FRN:0035012616 [ZhejiangULIRVISIONTechnologyCo.,Ltd.](“theapplicant”)certifiesthattheequipmentforwhich authorizationissoughtisnot“covered”equipmentprohibitedfromreceivinganequipment authorizationpursuanttosection2.903oftheFCCrules. Sincerely, (Applicantsignature) (LeiZhao)

Attestation Statements

ZhejiangULIRVISIONTechnologyCo.,Ltd. 8F/9F/10F/17F,BlockC,No.581HuojuAvenue,PuyanStreet,BinjiangDistrict,310000Hangzhou, Zhejiang,China FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:Jul.15,2024 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BE6SHW0002 FRN:0035012616 [ZhejiangULIRVISIONTechnologyCo.,Ltd.](“theapplicant”)certifiesthat,asofthedateofthefilingof theapplication,theapplicantisnotidentifiedontheCoveredListasanentityproducing“covered” equipment. Sincerely, (Applicantsignature) (LeiZhao)

Attestation Statements

ZhejiangULIRVISIONTechnologyCo., Ltd. 8F/9F/10F/17F,BlockC, No. 581 HuojuAvenue,PuyanStreet,BinjiangDistrict,310000Hangzhou, Zhejiang,China Date:Jul. 15, 2024 FederalCommunicationsCommission Authorizationand EvaluationDivision 7435 OaklandMills Road Columbia,MD 21046 FCC ID: 2BE6SHW0002 US Agent – AttestationStatement/ Part 2.911(d)(7) [ZhejiangULIRVISIONTechnologyCo., Ltd.] certifies,that as of [ Jul. 15, 2024 ], we have designatedFCC US Agent, LLC to acceptserviceof processon our behalffor FCC ID: 2BE6SHW0002. [ZhejiangULIRVISIONTechnologyCo., Ltd.], acceptsto maintainan agent of serviceof processin the UnitedStatesfor no less than one year after either the granteehas permanentlyterminatedall marketingand importationof the applicable equipmentwithin the U.S., or the conclusionof any Commission-relatedadministrativeor judicialproceedinginvolving the equipment,whicheveris later. FCC US Agent,LLC, acceptsas of the date of the filing of this application,the obligationof being the designatedagent for the purposeof acceptingserviceof processon behalfof [ZhejiangULIRVISIONTechnologyCo., Ltd.] for FCC ID: 2BE6SHW0002. DesignatedAgentInformation: CompanyName:FCC US Agent,LLC FRN: 0033402884 Address:3722 IllinoisAvenue,Saint Charles,IL, 60174,USA ContactPerson:Tim Payne Phone:708-571-3148 Email:[email protected] Sincerely, DesignatedAgent:FCC US Agent,LLC DesignatedAgent Representative:Tim Payne Company: [Zhejiang ULIRVISION Technology Co., Ltd.] Company Representative: [Lei Zhao] Tel: 0571-87209894 Email: [email protected] FRN: 0035012616 Signature: Signature:

Cover Letter(s)

Company Name: Zhejiang ULIRVISION Technology Co., Ltd. Add: 8,9,10,17F Block C, Sunwave Building, 581 Huoju Avenue, Binjiang District, Hangzhou 310052, Zhejiang, China) Tel:0571-87209894 Fax:0571-85125358 DECLARATION OF SIMILARITY Date:2024/06/29 Dear Sir or Madam: We,Zhejiang ULIRVISION Technology Co. Ltd. hereby declare that product series of F319,F325,F335,F350,F625,F635,F650,F950,F350D,F650D,F950D are electrically identical with the PCB design, components and electromagnetic compatibility characteristics. The differences of them are as follows: I.model 2. IR resolution 3.Optional Lens . Please refer to the below for detail. FCC ID: 2BE6SHW0002 IC: 32259-HW0002 Please contact me should there be need for any additional clarification or information. Sincerely, Signature: Typed or Printed Name:Lei Zhao Title:Manager Model HVIN PMN IR resolution Optional Lens F319 F3190100 F319 384×288 19mm F325 F3250100 F325 384×288 25mm F335 F3350100 F335 384×288 35mm F350 F3500100 F350 384×288 50mm F625 F6250100 F625 640×512 25mm F635 F6350100 F635 640×512 35mm F650 F6500100 F650 640×512 50mm F950 F9500100 F950 1280×1024 50mm F350D F350D0100 F350D 384×288 25-50mm zoom lens F650D F650D0100 F650D 640×512 25-50mm zoom lens F950D F950D0100 F950D 1280×1024 25-50mm zoom lens

ID Label/Location Info

Label Location 24mm*20mm FCC ID: 2BE6SHW0002 IC ID: 32259-HW0002 HVIN: F3190100 24mm*20mm FCC ID: 2BE6SHW0002 IC ID: 32259-HW0002 HVIN: F3250100 24mm*20mm FCC ID: 2BE6SHW0002 IC ID: 32259-HW0002 HVIN: F3350100 24mm*20mm FCC ID: 2BE6SHW0002 IC ID: 32259-HW0002 HVIN: F3500100 24mm*20mm FCC ID: 2BE6SHW0002 IC ID: 32259-HW0002 HVIN: F6250100 24mm*20mm FCC ID: 2BE6SHW0002 IC ID: 32259-HW0002 HVIN: F6350100 24mm*20mm FCC ID: 2BE6SHW0002 IC ID: 32259-HW0002 HVIN: F6500100 24mm*20mm FCC ID: 2BE6SHW0002 IC ID: 32259-HW0002 HVIN: F9500100 24mm*20mm FCC ID: 2BE6SHW0002 IC ID: 32259-HW0002 HVIN: F350D0100 24mm*20mm FCC ID: 2BE6SHW0002 IC ID: 32259-HW0002 HVIN: F650D0100 24mm*20mm FCC ID: 2BE6SHW0002 IC ID: 32259-HW0002 HVIN: F950D0100

RF Exposure Info

CALIBRATION DATA PROBE CALIBRATION DATA DAE CALIBRATION DATA DIPOLE CALIBRATION DATA

RF Exposure Info

Page 1 of 33 SAR Test Report Report No.: AGC10839240701FH01 FCC ID : 2BE6SHW0002 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Thermal Monocular BRAND NAME : N/A MODEL NAME : F335, F319, F325, F350, F625, F635, F650, F950, F350D, F650D, F950D APPLICANT : Zhejiang ULIRVISION Technology Co., Ltd. DATE OF ISSUE : Jul. 15, 2024 STANDARD(S) : IEEE Std. 1528:2013 FCC 47 CFR Part 2§2.1093 IEEE Std C95.1 ™-2005 REPORT VERSION : V1.0 Attestation of Global Compliance(Shenzhen) Co., Ltd. Report No.: AGC10839240701FH01 Page 2 of 33 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Jul. 15, 2024 Valid Initial Release Report No.: AGC10839240701FH01 Page 3 of 33 Test Report Applicant Name Zhejiang ULIRVISION Technology Co., Ltd. Applicant Address 8F/9F/10F/17F, Block C, No. 581 Huoju Avenue, Puyan Street, Binjiang District, 310000 Hangzhou, Zhejiang, China Manufacturer Name Zhejiang ULIRVISION Technology Co., Ltd. Manufacturer Address 8F/9F/10F/17F, Block C, No. 581 Huoju Avenue, Puyan Street, Binjiang District, 310000 Hangzhou, Zhejiang, China Factory Name Zhejiang ULIRVISION Technology Co., Ltd. Factory Address 8F/9F/10F/17F, Block C, No. 581 Huoju Avenue, Puyan Street, Binjiang District, 310000 Hangzhou, Zhejiang, China Product Designation Thermal Monocular Brand Name N/A Model Name F335 Series models F319, F325, F350, F625, F635, F650, F950, F350D, F650D, F950D Declaration of Difference See the declaration of similarity file Adaptor information AC 100-240V/50/60Hz; DC 5V Applicable Standard IEEE Std. 1528:2013 FCC 47 CFR Part 2§2.1093 IEEE Std C95.1 ™-2005 Date of receipt of test item Jul. 02, 2024 Test Date Jul. 08, 2024 Report Template AGCRT-US-2.4G/SAR (2021-04-20) Note: The results of testing in this report apply to the product/system which was tested only. Prepared By Thea Huang (Project Engineer) Jul. 15, 2024 Reviewed By Calvin Liu (Reviewer) Jul. 15, 2024 Approved By Max Zhang (Authorized Officer) Jul. 15, 2024 Report No.: AGC10839240701FH01 Page 4 of 33 TABLE OF CONTENTS 1. SUMMARY OF MAXIMUM SAR VALUE ......................................................................................................... 5 2. GENERAL INFORMATION ............................................................................................................................... 6 2.1. EUT DESCRIPTION......................................................................................................................................... 6 3. SAR MEASUREMENT SYSTEM ........................................................................................................................ 7 3.1. THE DASY5 SYSTEM USED FOR PERFORMING COMPLIANCE TESTS CONSISTS OF FOLLOWING ITEMS .................... 7 3.2. DASY5 E-FIELD PROBE ................................................................................................................................. 8 3.3. DATA ACQUISITION ELECTRONICS DESCRIPTION ............................................................................................... 8 3.4. ROBOT .......................................................................................................................................................... 9 3.5. LIGHT BEAM UNIT .......................................................................................................................................... 9 3.6. DEVICE HOLDER .......................................................................................................................................... 10 3.7. MEASUREMENT SERVER ............................................................................................................................... 10 3.8. PHANTOM ................................................................................................................................................. 11 4. SAR MEASUREMENT PROCEDURE .............................................................................................................. 12 4.1. SPECIFIC ABSORPTION RATE (SAR) .............................................................................................................. 12 4.2. SAR MEASUREMENT PROCEDURE ................................................................................................................ 13 4.3. RF EXPOSURE CONDITIONS ......................................................................................................................... 15 5. TISSUE SIMULATING LIQUID ......................................................................................................................... 16 5.1. THE COMPOSITION OF THE TISSUE SIMULATING LIQUID..................................................................................... 16 5.2. TISSUE DIELECTRIC PARAMETERS FOR HEAD AND BODY PHANTOMS ............................................................... 16 5.3. TISSUE CALIBRATION RESULT ....................................................................................................................... 17 6. SAR SYSTEM CHECK PROCEDURE ........................................................................................................... 18 6.1. SAR SYSTEM CHECK PROCEDURES ............................................................................................................. 18 6.2. SAR SYSTEM CHECK ................................................................................................................................... 19 7. EUT TEST POSITION ...................................................................................................................................... 21 7.1. BODY WORN POSITION ................................................................................................................................ 21 8. SAR EXPOSURE LIMITS ............................................................................................................................... 22 9. TEST FACILITY ......................…

Text truncated - open the document above for the full version.

Test Report

Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 35 of 64 Rev. 23.00 11G Ant1 2412 11G Ant1 2437 11G Ant1 2462 Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 36 of 64 Rev. 23.00 11N20 Ant1 2412 11N20 Ant1 2437 11N20 Ant1 2462 Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 37 of 64 Rev. 23.00 9.5 Spurious RF conducted emissions Test Method 1. The RF output of EUT was connected to the spectrum analyzer by RF cable. The path loss was compensated to the results for each measurement. 2. Set to the maximum power setting, the instrument center frequency is set to the nominal EUT channel center frequency enable the EUT transmit continuously. 3. Use the following spectrum analyzer settings: Span = wide enough to capture the peak level of the in-band emission and all spurious emissions (e.g., harmonics) from the lowest frequency generated in the EUT up through the 10 th harmonic. Typically, several plots are required to cover this entire span. RBW = 100 kHz, VBW≥3RBW, Sweep = auto, Detector function = peak, Trace = max hold 4. Allow the trace to stabilize. Set the marker on the peak of any spurious emission recorded. 5. The level displayed must comply with the limit specified in this Section. Submit these plots. 6. Repeat above procedures until all frequencies measured were complete. Limit Frequency Range Limit (dBc) MHz 30-25000 -20 Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 38 of 64 Rev. 23.00 Spurious RF conducted emissions 802.11 B Ant1 Out-of-Band Emissions Channel 1 (2412MHz) Reference point Spurious Emission (30MHz – 1GHz) Spurious Emission (1GHz –5GHz) Spurious Emission (5GHz –26.5GHz) Note: The emission which exceed the limit is the fundamental. Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 39 of 64 Rev. 23.00 Out-of-Band Emissions Channel 6 (2437MHz) Reference point Spurious Emission (30MHz – 1GHz) Spurious Emission (1GHz –5GHz) Spurious Emission (5GHz –26.5GHz) Note: The emission which exceed the limit is the fundamental. Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 40 of 64 Rev. 23.00 Out-of-Band Emissions Channel 11 (2462MHz) Reference point Spurious Emission (30MHz – 1GHz) Spurious Emission (1GHz –5GHz) Spurious Emission (5GHz –26.5GHz) Note: The emission which exceed the limit is the fundamental. Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 41 of 64 Rev. 23.00 802.11 G Ant1 Out-of-Band Emissions Channel 1 (2412MHz) Reference point Spurious Emission (30MHz – 1GHz) Spurious Emission (1GHz –5GHz) Spurious Emission (5GHz –26.5GHz) Note: The emission which exceed the limit is the fundamental. Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 42 of 64 Rev. 23.00 Out-of-Band Emissions Channel 6 (2437MHz) Reference point Spurious Emission (30MHz – 1GHz) Spurious Emission (1GHz –5GHz) Spurious Emission (5GHz –26.5GHz) Note: The emission which exceed the limit is the fundamental. Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 43 of 64 Rev. 23.00 Out-of-Band Emissions Channel 11 (2462MHz) Reference point Spurious Emission (30MHz – 1GHz) Spurious Emission (1GHz –5GHz) Spurious Emission (5GHz –26.5GHz) Note: The emission which exceed the limit is the fundamental. Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 44 of 64 Rev. 23.00 802.11 N20 Ant1 Out-of-Band Emissions Channel 1 (2412MHz) Reference point Spurious Emission (30MHz – 1GHz) Spurious Emission (1GHz –5GHz) Spurious Emission (5GHz –26.5GHz) Note: The emission which exceed the limit is the fundamental. Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 45 of 64 Rev. 23.00 Out-of-Band Emissions Channel 6 (2437MHz) Reference point Spurious Emission (30MHz – 1GHz) Spurious Emission (1GHz –5GHz) Spurious Emission (5GHz –26.5GHz) Note: The emission which exceed the limit is the fundamental. Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 46 of 64 Rev. 23.00 Out-of-Band Emissions Channel 11 (2462MHz) Reference point Spurious Emi…

Text truncated - open the document above for the full version.

Test Report

Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 1 of 64 Rev. 23.00 FCC/IC - TEST REPORT Report Number : 709502400494-00A Date of Issue: August 6, 2024 Model : F319, F325, F335, F350, F625, F635, F650, F950, F350D, F650D, F950D Product Type : Thermal Monocular Applicant : Zhejiang ULIRVISION Technology Co., Ltd. Address : 8F/9F/10F/17F, Block C, No. 581 Huoju Avenue, Puyan Street, Binjiang District, 310000 Hangzhou, Zhejiang, China Production Facility : Zhejiang ULIRVISION Technology Co., Ltd. Address : 8F/9F/10F/17F, Block C, No. 581 Huoju Avenue, Puyan Street, Binjiang District, 310000 Hangzhou, Zhejiang, China Test Result : ◼ Positive  Negative Total pages including Appendices : 64 TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 2 of 64 Rev. 23.00 1 Table of Contents 1 Table of Contents .................................................................................................................. 2 2 Details about the Test Laboratory .......................................................................................... 3 3 Description of the Equipment under Test ............................................................................... 4 4 Summary of Test Standards .................................................................................................. 6 5 Summary of Test Results ...................................................................................................... 7 6 General Remarks .................................................................................................................. 8 7 Test Setups ......................................................................................................................... 10 8 Systems test configuration .................................................................................................. 13 9 Technical Requirement ........................................................................................................ 14 9.1 Conducted Emission ..................................................................................................... 14 9.2 Conducted peak(average) output power and EIRP ...................................................... 17 9.3 6dB bandwidth and 99% Occupied Bandwidth ............................................................. 26 9.4 Power spectral density .................................................................................................. 33 9.5 Spurious RF conducted emissions ............................................................................... 37 9.6 Band edge .................................................................................................................... 47 9.7 Spurious radiated emissions for transmitter .................................................................. 54 10 Test Equipment List .......................................................................................................... 61 11 System Measurement Uncertainty ................................................................................... 62 12 Photographs of Test Set-ups ............................................................................................ 63 13 Photographs of EUT ........................................................................................................ 64 Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 3 of 64 Rev. 23.00 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch No.16 Lane, 1951 Du Hui Road, Shanghai 201108, P.R. China Telephone: +86 21 6141 0123 Fax: +86 21 6140 8600 FCC Registration No.: 820234 FCC Designation Number: CN1183 ISED CAB identifier CN0101 IC Registration No.: 31668 Report Number: 709502400494-00A EMC_SHA_F_R_02.04E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 4 of 64 Rev. 23.00 3 Description of the Equipment under Test Product: Thermal Monocular Model no.: F319, F325, F335, F350, F625, F635, F650, F950, F350D, F650D, F950D Hardware Version Identification No. (HVIN) F3190100, F3250100, F3350100, …

Text truncated - open the document above for the full version.

Test Report

Antennaspecificationsheet Supplier Iot-antennaTechnology(Kunshan)Co.,Ltd Materialcode:TP47-BT-C1-L60 Materialname:WIFIantenna CustomerName ZhejiangUlirvisionTechnologyCo.,Ltd Preparedby:WangLiReviewedby:Xiongbaoli Date:May27,2022 TianfengIntelligentTechnology(Kunshan)Co.,Ltd Address:No.18ChunxuRoad,DevelopmentZone,KunshanCity,JiangsuProvince Room406,LiancaiBusinessBuilding Email:[email protected] Phone:18112650090 Catalogue 1.Bothpartiesconfirm 2.Generalproductspecificationsreference 3.Productdrawingspecifications 4.Productpackagingmethod 5.EnvironmentalDeclaration 6.Documentresume 1. Bothpartiesconfirm 1.1CustomerConfirmationSignature Customer:ZhejiangUlirvisionTechnologyCo.,Ltd Customer department/position confirmationpersonsignatureconfirmationdate Hardware/RF Structure Business/Procurement Review Supplier:Iot-antennaTechnology(Kunshan)Co.,Ltd department/position confirmationpersonsignatureconfirmationdate AntennaEngineer StructuralEngineer QA Review 2.Generalproductspecificationsreference NO.ITEMSDETAILS 1Applicablefrequency band 2400---2500MHZ 2AntennaVSWR < 2:1 3Antennaimpedance50Ω 4AntennapolarizationVerticalpolarization 5Antennagain 1.95dBi 6Antennaefficiency > 60% 7Antennaarea34.5mm*9.5mm*0.25mm 8AntennaconnectorIPEX—MHF1 9AntennaextensioncableBlack1.1RFwirewithalengthof60mm 10AntennainstallationComeswithadhesivebacking 11Antennaoperating temperature -30---80° 12 Physical reference pictures 2.1Testdataandbargraph 3.Productdrawingspecifications 4. Productpackagingmethod Selfsealingbag+cardboardbox,allouterboxesarelabeledwith materialinformationcodes.Theshippingpackagingmeetsthe expresstransportationneedsandarrivesatthecustomer's designatedlocationwithoutanydamageorabnormalsituations. 5.EnvironmentalDeclaration AllmaterialsoftheproductmeettherequirementsofROHs,please refertothecorrespondinginformationfordetails 6. Documentresume DocumentNo. TP-QF-GGS- TP47-BT-C1-L60 NO : V1.0 ReleaseDate2022/05/27 AuthorWangli ReviewXiongbaoli

Contact Information

Applicant

Lei Zhao(Manager)
[email protected]0571-87209894Fax: 0571-85125358

Technical Contact

Zhejiang ULIRVISION Technology Co., Ltd.
[email protected]

China

Test Firm

TUV SUD Certification and Testing (China) Co., LtdYi Ba
[email protected]86 21 6140 0132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz212.30 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory is 0.64 W/kg.

Other Applications from Zhejiang ULIRVISION Technology Co., Ltd.

2BE6SHW0003

Thermal Monocular

Sep 05, 2024

Equipment Class

DTS - Digital Transmission System
2BE6SHW0001

Thermal lmaging Camera

Jun 19, 2024

Equipment Class

DTS - Digital Transmission System