FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Juyang Technology Co., Ltd/
  3. 2BE7V-JC006

2BE7V-JC006USB Wireless Adapter

Shenzhen Juyang Technology Co., Ltd
USB Wireless Adapter - FCC ID 2BE7V-JC006 - Shenzhen Juyang Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Mar 17, 2024
Application Purpose
Original Equipment
Date of Application
Mar 16, 2024
Equipment Note
USB Wireless Adapter
Frequency Range
5745.00000000 - 5825.00000000
Company
Shenzhen Juyang Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC warning statements: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The device has been evaluated to meet general RF exposure requirement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Attestation Statements

Shenzhen Juyang Technology Co., Ltd 3/11/2024 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2BE7V-JC006 Shenzhen Juyang Technology Co., Ltd (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Name: Rex Song Title: General manager Shenzhen Juyang Technology Co., Ltd 3/11/2024 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2BE7V-JC006 Shenzhen Juyang Technology Co., Ltd (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Name: Rex Song Title: General manager

Attestation Statements

1/1 US Agentfor Serviceof ProcessLETTEROF ATTESTATION TO: Officeof EngineeringTechnology FederalCommunicationsCommission 7435 OaklandMills Road Columbia,MD 21046 US Agentfor Serviceof Process: Companyname: FRN : ContactName: Address: HOPEK CORPORATION INC 0034562900 Peter Davis 4358 S BANNOCK ST ENGLEWOOD, CO 80110 United States TelephoneNo:561-235-6113 Email:[email protected] Applicant: Companyname:ShenzhenJuyangTechnologyCo., Ltd GranteeCode:2BE7V FCC ID:2BE7V-JC006 FRN :0035029115 ContactName:Rex Song Address:Room15132,Building3, XunmeiTechnologyPlaza,No. 8 Keyuan Road,Scienceand TechnologyPark Community,YuehaiStreet, NanshanDistrict,Shenzhen TelephoneNo: +86-15999576346 Fax No: / Email: [email protected] ShenzhenJuyangTechnologyCo., Ltdcertifiesthat, as of the date of this filing of the applicationwith the TCB, [HOPEKCORPORATIONINC] is our designatedUS agent for service of processfor the abovereferencedFCC ID.ShenzhenJuyangTechnologyCo., Ltdaccepts to maintainan agentfor no less than one year after the granteehas terminatedall marketing and importationor the conclusionof any commissionrelatedproceedinginvolvingequipment. [HOPEKCORPORATIONINC] accepts,as of the date of the filing of the application,the obligationof the designatedUS agent for serviceof processfor the abovereferenceFCC ID. The US Agentfor Serviceof Processis awareof and agreesto complywith the requirements outlinedin the FCC EquipmentAuthorizationProgram,Reportand OrderFCC 22-84,and clause§ 2.911. The Applicantis awareof and agreesto complywith the requirementsoutlinedin the FCC EquipmentAuthorizationProgram,Reportand Order FCC 22-84,and clause§ 2.911. Date: 2024-03-11 Applicant’s Name:Rex SongUS Agent ’s Name:Peter Davis Title:GeneralmanagerTitle:CEO Signature:Signature:

Cover Letter(s)

Difference Description We Shenzhen Juyang Technology Co., Ltd. state: Product name: USB Wireless Adapter Model: JC006, JC007, JC008, JC009, JC010, JC011, JC012, JC013, JC014, JC015, JC601, JC602, JC603, JC604, JC605 Only the name is different, and the functions, software, and circuits of all models are the same. Signed: Name: Rex Song Date: March 11, 2024 Title: General manager Telephone: +86-15999576346 Email: [email protected]

Cover Letter(s)

Shenzhen Juyang Technology Co., Ltd 3/13/2024 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR Product Name: USB Wireless Adapter FCC ID: 2BE7V-JC006 Model(s): JC006, JC007, JC008, JC009, JC010, JC011, JC012, JC013, JC014, JC015, JC601, JC602, JC603, JC604, JC605 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (Schematic Diagram, Block Diagram, Operational Description, Software Security Requirements For U-NII Devices) required to be submitted with this application be permanently withheld from public review. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market Please contact me if there is any information you may need. Sincerely, Signature: March 13, 2024 Name Rex Song Position General manager Company Name Shenzhen Juyang Technology Co., Ltd Address Room 15132, Building 3, Xunmei Technology Plaza, No. 8 Keyuan Road, Science and Technology Park Community, Yuehai Street, Nanshan District, Shenzhen Tel +86-15999576346 Fax / Email [email protected]

Cover Letter(s)

Shenzhen Juyang Technology Co., Ltd 3/11/2024 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen PSI Testing Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This agreement expires one year from the current date. Sincerely, Signature: March 11, 2024 Name Rex Song Position General manager Company Name Shenzhen Juyang Technology Co., Ltd Address Room 15132, Building 3, Xunmei Technology Plaza, No. 8 Keyuan Road, Science and Technology Park Community, Yuehai Street, Nanshan District, Shenzhen Tel +86-15999576346 Fax / Email [email protected]

ID Label/Location Info

Label Location FCC ID: 2BE7V-JC006 Model No.: JC006

Internal Photos

Page 1 of 2 Report No.: psi2401070-C01-R09 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 Appendix III internal photos FCC ID: 2BE7V-JC006 BT ANT 2.4G WiFi ANT 5G WiFi ANT Page 2 of 2 Report No.: psi2401070-C01-R09 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 ------End------

RF Exposure Info

FCC ID: 2BE7V-JC006 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 Prediction of MPE at a given distance 1. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) 2. Test Procedure Equation from page 18 of OET Bulletin 65, Edition 97-01 Where: S = power density P = power input to the antenna G = numeric gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the centre of radiation of the antenna FCC ID: 2BE7V-JC006 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 3. Result Mode Frequency (MHz) Prediction distance (cm) RF output power(Max) (dBm) Tune-up power (Max) MPE (mW/cm 2 ) Limit (mW/cm 2 ) SAR Test Exclusion dBm mW BT EDR 2402-2480 20 3.42 4 2.5119 0.0004 1 Yes BT LE 2402-2480 20 2.81 3 1.9953 0.0003 1 Yes 2.4G WIFI 2412-2462 20 15.71 16 39.8107 0.0069 1 Yes 5G WIFI B1 5180-5240 20 9.52 10 10.0000 0.0017 1 Yes 5G WIFI B2 5260-5320 20 9.36 10 10.0000 0.0017 1 Yes 5G WIFI B3 5500-5700 20 9.03 10 10.0000 0.0017 1 Yes 5G WIFI B4 5745-5825 20 9.41 10 10.0000 0.0017 1 Yes Maximum Simultaneous transmission MPE Ratios for BT+WIFI Max MPE Ratio BT /Limit Max MPE ratio WIFI /Limit ∑MPE ratios Limit Result 0.0004 0.0069 0.0073 1 PASS BT/2.4GWiFi Antenna Gain: Ceramic antenna, max gain -0.58dBi, 0.87(numeric) 5G WIFI Antenna Gain: Ceramic antenna, max gain -0.68dBi, 0.86(numeric) Then SAR evaluation is not required.

Test Report

Inverted F Antenna Specification Summary ITEMANT SPEC Model Name WIFI 5G ANT HorizontalVertical 5180MHz5240MHz5805MHz5180MHz5240MHz5805MHz Center Frequency -1.21-0.68-0.63-5.12-2.34-1.84 MAX. Gain -0.6 8dB PolarizationHorizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance50 Ohm Antenna Length 1 2.7mm Manufacture SHENZHEN MASNO TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) Horizontal: 5180 MHz 5240 MHz 5805 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Gain(dB) Frequency (MHz) MaxMinAvg 5180 -1.25374-30.0501-7.16316 5240 -0.736932-36.4854-7.46213 5805 -0.573212-22.0435-6.56367 Vertical: 5180 MHz 5240 MHz 5805 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Gain(dB) Frequency (MHz) MaxMinAvg 5180 -5.3233-22.2121-12.3265 5240 -2.3466-24.4837-10.5312 5805 -1.84220-9.2363-29.38341 ANT Test Labs:Attestation of Global Compliance Co., Ltd.

Test Report

Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 FCC TEST REPORT FCC ID: 2BE7V-JC006 On Behalf of Shenzhen Juyang Technology Co., Ltd USB Wireless Adapter Model No.: JC006, JC007, JC008, JC009, JC010, JC011, JC012, JC013, JC014, JC015, JC601, JC602, JC603, JC604, JC605 Prepared for : Shenzhen Juyang Technology Co., Ltd Address : Room 15132, Building 3, Xunmei Technology Plaza, No. 8 Keyuan Road, Science and Technology Park Community, Yuehai Street, Nanshan District, Shenzhen Prepared By : Shenzhen PSI Testing Co., Ltd. Address : 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao’an District, Shenzhen, Guangdong, China 518104 Report Number : psi2401070-C01-R10 Date of Receipt : January 31, 2024 Date of Test : February 1, 2024-February 28, 2024 Date of Report : February 28, 2024 Version Number : V0 Page 2 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 TABLE OF CONTENTS Description Page 1 TEST SUMMARY ..................................................................................................................................... 5 1.1 MEASUREMENT UNCERTAINTY............................................................................................................. 5 2 GENERAL INFORMATION ...................................................................................................................... 6 2.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 6 2.2 TEST MODE ........................................................................................................................................ 7 2.3 TEST FACILITY .................................................................................................................................... 7 2.4 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7 2.5 DEVIATION FROM STANDARDS ............................................................................................................. 7 2.6 ABNORMALITIES FROM STANDARD CONDITIONS.................................................................................... 7 2.7 OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................... 7 2.8 ADDITIONAL INSTRUCTIONS ................................................................................................................. 7 3 TEST INSTRUMENTS LIST ..................................................................................................................... 8 4 TEST RESULTS AND MEASUREMENT DATA ...................................................................................... 9 4.1 ANTENNA REQUIREMENT: .................................................................................................................... 9 4.2 CONDUCTED EMISSIONS ................................................................................................................... 10 4.3 EMISSION BANDWIDTH AND 99% OCCUPIED BANDWIDTH .................................................................... 13 4.4 PEAK TRANSMIT POWER ................................................................................................................... 79 4.5 POWER SPECTRAL DENSITY .............................................................................................................. 82 4.6 BAND EDGE .................................................................................................................................... 116 4.7 RADIATED EMISSION ....................................................................................................................... 138 4.8 FREQUENCY STABILITY .................................................................................................................... 144 Page 3 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 TEST REPORT DECLARATION Applicant : Shenzhen Juyang Technology Co., Ltd Address : Room 15132, Building 3, Xunmei Technology Plaza, No. 8 Keyuan Road, Science and Technology Park Community, Yuehai Street, Nanshan District, Shenzhen Manufacturer : Shenzhen Juyang Technology Co., Ltd Address : Room 15132, Building 3, Xunmei Technology Plaza, No. 8 Keyuan Road, Science and Technology Park Community, Yuehai Street, Nanshan District, Shenzhen EUT Description : USB Wireless Adapter (A) Model No. : JC006, JC007, JC008, JC009, JC010, JC011, JC012, JC013, JC014, JC015, JC601, JC602, JC603, JC604, JC605 (B) Trademark : N/A Measurement Standard Used: FCC Rules and Regulations Part 15 Subpart E ANSI C63.4:2014, ANSI C63.10:2013 The device described above is tested by Shenzhen PSI Testing Co., Ltd. to determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC Part 15 Subpart E limits both conducted and radiated emissions. The test results are contained in this test report and Shenzhen PSI Testing Co., Ltd. is assumed of full responsibility for the accuracy and completeness of these tests. After the test, our opinion is that EUT compliance with the requirement of the above standards. This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Shenzhen PSI Testing…

Text truncated - open the document above for the full version.

Test Report

Page 66 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 99%_OCB_NVNT_ANT1_802_11a_5745 -26BW_NVNT_ANT1_802_11a_5745 Page 67 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 99%_OCB_NVNT_ANT1_802_11a_5785 -26BW_NVNT_ANT1_802_11a_5785 Page 68 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 99%_OCB_NVNT_ANT1_802_11a_5825 -26BW_NVNT_ANT1_802_11a_5825 Page 69 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 99%_OCB_NVNT_ANT1_802_11n(HT20)_5745 -26BW_NVNT_ANT1_802_11n(HT20)_5745 Page 70 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 99%_OCB_NVNT_ANT1_802_11n(HT20)_5785 -26BW_NVNT_ANT1_802_11n(HT20)_5785 Page 71 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 99%_OCB_NVNT_ANT1_802_11n(HT20)_5825 -26BW_NVNT_ANT1_802_11n(HT20)_5825 Page 72 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 99%_OCB_NVNT_ANT1_802_11ac(VHT20)_5745 -26BW_NVNT_ANT1_802_11ac(VHT20)_5745 Page 73 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 99%_OCB_NVNT_ANT1_802_11ac(VHT20)_5785 -26BW_NVNT_ANT1_802_11ac(VHT20)_5785 Page 74 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 99%_OCB_NVNT_ANT1_802_11ac(VHT20)_5825 -26BW_NVNT_ANT1_802_11ac(VHT20)_5825 Page 75 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 99%_OCB_NVNT_ANT1_802_11n(HT40)_5755 -26BW_NVNT_ANT1_802_11n(HT40)_5755 Page 76 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 99%_OCB_NVNT_ANT1_802_11n(HT40)_5795 -26BW_NVNT_ANT1_802_11n(HT40)_5795 Page 77 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 99%_OCB_NVNT_ANT1_802_11ac(VHT40)_5755 -26BW_NVNT_ANT1_802_11ac(VHT40)_5755 Page 78 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 99%_OCB_NVNT_ANT1_802_11ac(VHT40)_5795 -26BW_NVNT_ANT1_802_11ac(VHT40)_5795 . Page 79 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 4.4 Peak Transmit Power Test Requirement: FCC Part15 E Section 15.407 Test Method: KDB 789033 D02 General UNII Test Procedures New Rules v02r01 Limit: For the band 5.15-5.25GHz, 5.25-5.35GHz, 5.47-5.725GHz, the maximum conducted output power over the frequency bands of operation shall not exceed 250mW. For the band 5.725-5.85GHz, the maximum conducted output power over the frequency bands of operation shall not exceed 1W. Test setup: Test procedure: Measurement using an RF average power meter (i) Measurements may be performed using a wideband RF power meter with a thermocouple detector or equivalent if all of the conditions listed below are satisfied a) The EUT is configured to transmit continuously or to transmit with a constant duty cycle. b) At all times when the EUT is transmitting, it must be transmitting at its maximum power control level. c) The integration period of the power meter exceeds the repetition period of the transmitted signal by at least a factor of five. (ii) If the transmitter does …

Text truncated - open the document above for the full version.

Test Report

Page 132 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 Mode: 802.11ac(HT40) Frequency: 5510MHz Antenna Pol. Frequency (MHz) Reading Level Factor Measure Level Limit (dBuV/m) Over limit(dB) Detector (dBuV) (dB/m) (dBuV/m) H 5470.00 34.03 17.20 51.23 68.20 -16.97 PK V 5470.00 33.56 17.20 50.76 68.20 -17.44 PK Mode: 802.11ac(HT40) Frequency: 5510MHz Antenna Pol. Frequency (MHz) Reading Level Factor Measure Level Limit (dBuV/m) Over limit(dB) Detector (dBuV) (dB/m) (dBuV/m) H 5470.00 27.24 17.20 44.44 54.00 -9.56 AV V 5470.00 24.86 17.20 42.06 54.00 -11.94 AV Mode: 802.11ac(HT40) Frequency: 5670MHz Antenna Pol. Frequency (MHz) Reading Level Factor Measure Level Limit (dBuV/m) Over limit(dB) Detector (dBuV) (dB/m) (dBuV/m) H 5725.00 37.88 17.20 55.08 68.20 -13.12 PK V 5725.00 34.13 17.20 51.33 68.20 -16.87 PK Mode: 802.11ac(HT40) Frequency: 5670MHz Antenna Pol. Frequency (MHz) Reading Level Factor Measure Level Limit (dBuV/m) Over limit(dB) Detector (dBuV) (dB/m) (dBuV/m) H 5725.00 27.98 17.20 45.18 54.00 -8.82 AV V 5725.00 23.86 17.20 41.06 54.00 -12.94 AV Page 133 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 Band4 Bandedge_NVNT_ANT1_802_11a_5745 Bandedge_NVNT_ANT1_802_11a_5825 Page 134 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 Bandedge_NVNT_ANT1_802_11n(HT20)_5745 Bandedge_NVNT_ANT1_802_11n(HT20)_5825 Page 135 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 Bandedge_NVNT_ANT1_802_11ac(VHT20)_5745 Bandedge_NVNT_ANT1_802_11ac(VHT20)_5825 Page 136 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 Bandedge_NVNT_ANT1_802_11n(HT40)_5755 Bandedge_NVNT_ANT1_802_11n(HT40)_5795 Page 137 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 Bandedge_NVNT_ANT1_802_11ac(VHT40)_5755 Bandedge_NVNT_ANT1_802_11ac(VHT40)_5795 Page 138 of 145 Report No.: psi2401070-C01-R10 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 4.7 Radiated Emission Test Requirement: FCC Part15 C Section 15.209 and 15.205 Test Method: ANSI C63.10:2013 Test Frequency Range: 30MHz to 40GHz Test site: Measurement Distance: 3m (Semi-Anechoic Chamber) Receiver setup: Frequency Detector RBW VBW Value 30MHz- 1GHz Quasi-peak 100KHz 300KHz Quasi-peak Value Above 1GHz Peak 1MHz 3MHz Peak Value AV 1MHz 3MHz Average Value Limit: Frequency Limit (dBuV/m @3m) Remark 30MHz-88MHz 40.0 Quasi-peak Value 88MHz-216MHz 43.5 Quasi-peak Value 216MHz-960MHz 46.0 Quasi-peak Value 960MHz-1GHz 54.0 Quasi-peak Value Above 1GHz 74.0 Peak Value 54.0 Average Value Test Procedure: Substitution method was performed to determine the actual ERP emission levels of the EUT. The following test procedure as below: 1>.Below 1GHz test procedure: 1. The EUT was placed on the top of a rotating table (0.8m for below 1GHz and 1.5 meters for above 1GHz) above the ground at a 3 meter camber. The table was rotated 360 degrees to determine the position of the highest radiation. 2. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. 3. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. 4. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rotable table was turned from 0 degrees to 360 degrees to find the maximum reading. 5. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. 6. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet. 2>.Above 1GHz test procedure: 1. On the test site as test setup graph above,the EUT shall be placed at the 1.5m support on the turntable and in the position closest to normal use as declared by the provider. 2. The test antenna shall be oriented initially for vertical polarization and shall be chosen to correspond to the frequency of the transmitter.The output of the test antenna shall be connected to the measuring receiver. 3. The transmitter shall be switched on, if possible, without modulation and the measurin…

Text truncated - open the document above for the full version.

Test Report

Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 FCC TEST REPORT FCC ID: 2BE7V-JC006 On Behalf of Shenzhen Juyang Technology Co., Ltd USB Wireless Adapter Model No.: JC006, JC007, JC008, JC009, JC010, JC011, JC012, JC013, JC014, JC015, JC601, JC602, JC603, JC604, JC605 Prepared for : Shenzhen Juyang Technology Co., Ltd Address : Room 15132, Building 3, Xunmei Technology Plaza, No. 8 Keyuan Road, Science and Technology Park Community, Yuehai Street, Nanshan District, Shenzhen Prepared By : Shenzhen PSI Testing Co., Ltd. Address : Building i, No.2, Lixin Road, Fuyong Street, Bao'an District, 518103, Shenzhen, Guangdong, China Report Number : psi2401070-C01-R13 Date of Receipt : January 31, 2024 Date of Test : February 1, 2024-February 28, 2024 Date of Report : February 28, 2024 Version Number : V0 Page 2 of 23 Report No.: psi2401070-C01-R13 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-la…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Rex Song(General manager)
[email protected]+8615999576346Fax: /

Test Firm

Shenzhen PSI Testing Co., Ltd.Simple Guan
[email protected]+86 0755-23019820

Technical Specifications

#Rule PartsFrequency RangePower Output
415E5.75 GHz - 5.83 GHz8.73 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The device supports 20MHz and 40MHz bandwidths. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.