Horizon Powered USA Inc. To: Federal Communications Commission Date: 2024/05/27 7435 Oakland Mills Road Columbia, MD 21046 USA Attestation Section 2.911(d)(5)(i) and Section 2.911(d)(5)(ii) (KDB 986446 D01 Covered Equipment) Section 2.911(d)(5)(i) Horizon Powered USA Inc. certifies that the equipment for which authorization is sought is not βcoveredβ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Section 2.911(d)(5)(ii) Horizon Powered USA Inc. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing βcoveredβ equipment. Type of Equipment subject to FCC Certification: 5G USB Dongle DG505G FCC ID: 2BE94DG505G If you have any questions, please feel free to contact me Contact Person: Athar Waheed Position in the Company: Manager Date of Signature: 2024-05-27 ___________________________ Signatory (signature of the applicant)
Horizon Powered USA Inc. To: Federal Communications Commission Date: 2024/05/27 7435 Oakland Mills Road Columbia, MD 21046 USA Attestation Certification designating a U.S. Agent for Service of Process Section 2.911(d)(7) (KDB 986446 D01 Covered Equipment) Horizon Powered USA Inc. (βthe applicantβ) as required by section 2.911(d)(7), designate below contact located in the United States for purposes of acting as the applicantβs agent for service of process. The applicant also acceptance to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Type of E quipment subject to FCC Certification: 5G/LTE CBRS USB-C Dongle FCC ID: 2BE94DG505G Sincerely yours, Applicant/Grantee US Agent FRN: 0035057355 FRN: 0035057355 (Signature) (Signature) Horizon Powered USA Inc. Athar Waheed Manager [email protected] 8350 NW 52nd Terrace, Suite 301 Horizon Powered USA Inc. Athar Waheed Manager [email protected] 8350 NW 52nd Terrace, Suite 301 Miami, Florida33166 United States Miami, Florida33166 United States
Horizon Powered USA Inc. Date: 2024/05/27 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 To Whom It May Concern: The Horizon Powered USA Inc., the undersigned, hereby authorizes Mrs.wendy Zhan from Shenzhen Morlab Communications Technology Co., Ltd., to act on the behalf of the Horizon Powered USA Inc. solely in matters relating to the application for an FCC equipment authorization for FCC ID: 2BE94DG505G including the signing of documents in connection with this Application. Necessary acts carried out Shenzhen Morlab Communications Technology Co., Ltd. on our behalf of the Horizon Powered USA Inc. in connection with the Application shall have the same effect as acts of the Horizon Powered USA Inc..Horizon Powered USA Inc. also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Thank you for your attention to this matter. Yours Sincerely, Signatory: Contact name: Athar Waheed Title: Manager Tel: (714) 873-210 2 Email: [email protected] Company name: Horizon Powered USA Inc.
Horizon Powered USA Inc. Date: 2024/06/19 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 Re: Request of Confidentiality for FCC ID: 2BE94DG505G To Whom it may concern: Pursuant to sections 0.457 and 0.459 of Commissionβs Rules(CFR 47), and Section 552(b)(4) of the Freedom of Information Act, Horizon Powered USA Inc. hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA04-1705. This provision will give Horizon Powered USA Inc. temporary confidentiality of commercially sensitive information prior to product release. The requested Permanent and Short-Term Confidential exhibits are listed as follows: PERMANENT AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description PERMANENT 1 Block Diagram 2 Operational Description 3 Schematics 4 BOM SHORT-TERM 5 External Photos 6 Internal Photos 7 Test-Setup Photos 8 User Manual The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. Signatory: Contact name: Athar Waheed Title: Manager Tel: (171)487-3210 2 Email: [email protected] Company name: Horizon Powered USA Inc.
Horizon Powered USA Inc. Supplierβs Declaration Of Conformity for the FCC SDoC Procedure The following Equipment adapt FCC SDoC Procedure according to FCC part 2.906 : Product Name: 5G/LTE CBRS USB-C Dongle Brand Name: Horizon Model Number: DG505G Report Number: SZ24030252E01 Itβs herewith confirmed to comply with the requirements of FCC Part 15 Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. It is understood that each unit marketed is identical to the device as tested, and any changes to the device that could adversely affect the emission characteristics will require retest. The following importer / responsible party in United States: Company Name: NA Company Address: NA Telephone: NA Fax: NA Person is responsible for marking this declaration: Athar Waheed Manager ____________________________________ ______________________________________ Name (Full name)Position / Title 2024-05-27 ____________________________________ _____________________________________ Legal Signature Date
Label: Lacation: Model name:DG505G FCC ID:2BE94DG505G
NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ24030252S01 Page 1 of 51 TEST REPORT APPLICANT : Horizon Powered USA Inc. PRODUCT NAME : 5G/LTE CBRS USB-C Dongle MODEL NAME : DG505G BRAND NAME : Horizon FCC ID : 2BE94DG505G STANDARD(S) : FCC 47 CFR Part 2(2.1093) IEEE 1528-2013 RECEIPT DATE : 2024-04-07 TEST DATE : 2024-05-10 to 2024-05-15 ISSUE DATE : 2024-06-20 Edited by : Xie Yiyun (Rapporteur) Approved by: Gan Yueming (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ24030252S01 Page 2 of 51 DIRECTORY 1. SAR Results Summary ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 5 2. Technical Information ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 6 2.1. Applicant and Manufacturer Information βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 6 2.2. Equipment under Test (EUT) Description ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 6 2.3. Environment of Test Site/Conditions βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 7 3. Specific Absorption Rate (SAR) βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 8 3.1. Introductionββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 8 3.2. SAR Definition βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 8 4. RF Exposure Limits βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 9 4.1. Uncontrolled Environment βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 9 4.2. Controlled Environment βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 9 5. Applied Reference Documents ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 10 6. SAR Measurement System βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 11 6.1. E-Field Probe βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 12 6.2. Data Acquisition Electronics (DAE) ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 13 6.3. Robot ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 13 6.4. Measurement Server βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 14 6.5. Light Beam Unit βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 14 6.6. Phantom βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 14 6.7. Device Holder ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 15 6.8. Data Storage and Evaluation βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 16 6.9. Test Equipment List ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 18 7. Tissue Simulating Liquids ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 20 8. SAR System Verification βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 22 8.1. Purpose of System Performance check ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 22 8.2. System Setup βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 22 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ24030252S01 Page 3 of 51 8.3. Validation Results βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 23 9. EUT Testing Position βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 26 9.1. Simple Dongle Procedure ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 26 9.2. Exposure Position Conditions ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 26 10. Measurement Procedures βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 28 10.1. Spatial Peak SAR Evaluation βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 28 10.2. Power Reference Measurement ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 29 10.3. Area Scan Procedures ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ¦
Text truncated - open the document above for the full version.
MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ24030252S01 Annex C Plots of System Performance Check Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2024/5/11 System Check_2600MHz_Head_05.11 Communication System: UID 0, CW (0); Frequency: 2600 MHz;Duty Cycle: 1:1 Medium: HSL_2600 Medium parameters used: f = 2600 MHz; Ο = 1.956 S/m; Ξ΅ r = 38.238; Ο = 1000 kg/m 3 Ambient TemperatureοΌ23.2 Β°C; Liquid TemperatureοΌ22.1 Β°C DASY5 Configuration: - Probe: EX3DV4 - SN7608; ConvF(7.23, 7.26, 6.75) @ 2600 MHz; Calibrated: 2024/3/21 - Sensor-Surface: 2 mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1643; Calibrated: 2024/3/27 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) CW2600/Area Scan (101x101x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 17.2 W/kg CW2600/Zo om Scan (7x7x7)/Cube 0: Measurement grid: dx =5mm, dy=5mm, dz=5mm Reference Value = 94.85 V/m; Power Drift = -0.08 dB Peak SAR (extrapolated) = 31.0 W/kg SAR(1 g) = 14.6 W/kg; SAR(10 g) = 6.52 W/kg Maximum value of SAR (measured) = 16.9 W/kg 0 dB = 16.9 W/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ24030252S01 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2024/5/13 System Check_2600MHz_Head Communication System: UID 0, CW (0); Frequency: 2600 MHz;Duty Cycle: 1:1 Medium: HSL_2600 Medium parameters used: f = 2600 MHz; Ο = 1.965 S/m; Ξ΅ r = 38.155; Ο = 1000 kg/m 3 Ambient TemperatureοΌ23.2 Β°C; Liquid TemperatureοΌ22.1 Β°C DASY5 Configuration: - Probe: EX3DV4 - SN7608; ConvF(7.23, 7.26, 6.75) @ 2600 MHz; Calibrated: 2024/3/21 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1643; Calibrated: 2024/3/27 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) CW2600/Area Scan (101x101x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 14.2 W/kg CW2600/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 94.81 V/m; Power Drift = -0.08 dB Peak SAR (extrapolated) = 32.7 W/kg SAR(1 g) = 15.31 W/kg; SAR(10 g) = 6.59 W/kg Maximum value of SAR (measured) = 17.8 W/kg 0 dB = 17.8 W/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ24030252S01 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2024/5/10 System Check_3500MHz_Head Communication System: UID 0, CW (0); Frequency: 3500 MHz;Duty Cycle: 1:1 Medium: HSL 3500 Medium parameters used: f = 3500 MHz; Ο = 2.933 S/m; Ξ΅ r = 37.274; Ο = 1000 kg/m 3 Ambient TemperatureοΌ23.2 Β°C; Liquid TemperatureοΌ22.1 Β°C DASY5 Configuration: - Probe: EX3DV4 - SN7608; ConvF(6.28, 6.36, 5.91) @ 3500 MHz; Calibrated: 2024/3/21 - Sensor-Surface: 2mm (Mec hanical Surface Detection) - Electronics: DAE4 Sn1643; Calibrated: 2024/3/27 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) CW3500/Area Scan (101x101x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 12.3 W/kg CW3500/Zoom Scan (7x7x13)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 30.91 V/m; Power Drift = -0.06 dB Peak SAR (extrapolated) = 17.6 W/kg SAR(1 g) = 7.31 W/kg; SAR(10 g) = 2.62 W/kg Maximum value of SAR (measured) = 12.1 W/kg 0 dB = 12.1 W/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ24030252S01 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2024/5/12 System Check_3700MHz_Head_05.12 Communication System: UID 0, CW (0); Frequency: 3700 MHz;Duty Cycle: 1:1 Medium: HSL 3700 Medium parameters used: f = 3700 MHz; Ο = 3.118 S/m; Ξ΅ r = 37.57; Ο = 1000 kg/m 3 Ambient TemperatureοΌ23.2 Β°C; Liquid TemperatureοΌ22.1 Β°C DASY5 Configuration: - Probe: EX3DV4 - SN7608; ConvF(6.24, 6.29, 5.87) @ 3700 MHz; Calibrated: 2024/3/21 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1643; Calibrated: 2024/3/27 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) CW3700/Area Scan (81x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 13.8 W/kg CW3700/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 55.39 V/m; Power Drift = -0.12 dB Peak SAR (extrapolated) = 21.4 W/kg SAR(1 g) = 7.08 W/kg; SAR(10 g) = 2.49 W/kg Maximum value of SAR (measured) = 14.1 W/kg 0 dB = 14.1 W/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ24030252S01 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2024/5/14 System Check_3700MHz_Head Communication System: UID 0, CW (0); Frequency: 3700β¦
Text truncated - open the document above for the full version.
MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ24030252S01 Annex D Plots of Maximum SAR Test Results Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2024/5/13 LTE Band 41_20MHz_QPSK_1RB_0Offset_Horizontal-UP_5mm_Ch41055 Communication System: UID 0, LTE (0); Frequency: 2636.5 MHz;Duty Cycle: 1:1.59 Medium: HSL_2600 Medium parameters used: f = 2637 MHz; Ο = 2.065 S/m; Ξ΅ r = 37.975; Ο = 1000 kg/m 3 Ambient TemperatureοΌ23.2 Β°C; Liquid TemperatureοΌ22.1 Β°C DASY5 Configuration: - Probe: EX3DV4 - SN7608; ConvF(7.23, 7.26, 6.75) @ 2636.5 MHz; Calibrated: 2024/3/21 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1643; Calibrated: 2024/3/27 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Ch41055/Area Scan (71x61x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 1.47 W/kg Ch41055/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 16.80 V/m; Power Drift = -0.09 dB Peak SAR (extrapolated) = 1.93 W/kg SAR(1 g) = 0.841 W/kg; SAR(10 g) = 0.437 W/kg Maximum value of SAR (measured) = 1.30 W/kg 0 dB = 1.30 W/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ24030252S01 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2024/5/12 LTE Band 48_20MHz_QPSK_1RB_0Offset_Horizontal-Down_5mm_Ch55990 Communication System: UID 0, LTE (0); Frequency: 3625 MHz;Duty Cycle: 1:1.59 Medium: HSL_3700 Medium parameters used: f = 3625 MHz; Ο = 3.103 S/m; Ξ΅ r = 37.919; Ο = 1000 kg/m 3 Ambient TemperatureοΌ23.2 Β°C; Liquid TemperatureοΌ22.1 Β°C DASY5 Configuration: - Probe: EX3DV4 - SN7608; ConvF(6.24, 6.29, 5.87) @ 3625 MHz; Calibrated: 2024/3/21 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1643; Calibrated: 2024/3/27 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Ch55990/Area Scan (71x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 0.756 W/kg Ch55990/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.853 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 1.13 W/kg SAR(1 g) = 0.360 W/kg; SAR(10 g) = 0.096 W/kg Maximum value of SAR (measured) = 0.704 W/kg 0 dB = 0.704 W/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ24030252S01 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2024/5/13 5G NR n41_100MHz_DFT-S-QPSK_1RB_1Offset_Horizontal-Down_5mm_Ch528000 Communication System: UID 0, 5G NR (0); Frequency: 2640 MHz;Duty Cycle: 1:1 Medium: HSL_2600 Medium parameters used: f = 2640 MHz; Ο = 2.079 S/m; Ξ΅ r = 37.678; Ο = 1000 kg/m 3 Ambient TemperatureοΌ 23.2 Β°C; Liquid TemperatureοΌ22.1 Β°C DASY5 Configuration: - Probe: EX3DV4 - SN7608; ConvF(7.23, 7.26, 6.75) @ 2640 MHz; Calibrated: 2024/3/21 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1643; Calibrated: 2024/3/27 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Ch52800/Area Scan (71x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 1.76 W/kg Ch52800/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 11.51 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 2.27 W/kg SAR(1 g) = 1.03 W/kg; SAR(10 g) = 0.447 W/kg Maximum value of SAR (measured) = 1.63 W /kg 0 dB = 1.63 W/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ24030252S01 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2024/5/12 5G NR n48_100MHz_DFT-S-QPSK_1RB_1Offset_Horizontal-Down_5mm_Ch641666 Communication System: UID 0, 5G NR (0); Frequency: 3624.99 MHz;Duty Cycle: 1:1 Medium: HSL_3700 Medium parameters used: f = 3624.99 MHz; Ο = 2.971 S/m; Ξ΅ r = 37.919; Ο = 1000 kg/m 3 Ambient TemperatureοΌ 23.2 Β°C; Liquid TemperatureοΌ22.1 Β°C DASY5 Configuration: - Probe: EX3DV4 - SN7608; ConvF(6.24, 6.29, 5.87) @ 3624.99 MHz; Calibrated: 2024/3/21 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1643; Calibrated: 2024/3/27 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Ch641666/Area Scan (71x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 1.74 W/kg Ch641666/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 6.605 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 2.31 W/kg SAR(1 g) = 0.923 W/kg; SAR(10 g) = 0.375 W/kg Maximum value of SAR (measured) = 1.53 W/kg 0 dB = 1.53 W/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORTβ¦
Text truncated - open the document above for the full version.
MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ24030252S01 Annex E Conducted Power Note: Conducted power unit: dBm The target power was recorded in the manufacturerβs document. BW [MHz]ModulationRB SizeRB Offset Low Channel Middle Low Channel Middle Channel Middle High Channel High Channel BW [MHz]ModulationRB SizeRB Offset Power Low Ch. / Freq. Middle-Low Channel Middle-Low Channel Middle-High Channel High Channel 39750401854062041055414905534055830559905615056640 25062549.525932636.5268035603609362536413690 20QPSK1023.5523.5223.5923.5123.5020QPSK1021.1721.2021.2321.1821.10 20QPSK14923.4023.3823.5223.3323.5020QPSK14920.6720.6920.6920.7220.71 20QPSK19923.4323.5323.5623.3923.4020QPSK19920.7320.7120.7320.5320.67 20QPSK50022.6222.6122.6322.5622.5720QPSK50020.2720.1820.3020.1320.03 20QPSK502422.4322.4122.6322.4222.4820QPSK502419.7219.7119.7719.8119.70 20QPSK505022.5622.3622.5922.4122.5520QPSK505019.7219.6319.8519.6619.50 20QPSK100022.4822.5022.5622.6022.3720QPSK100019.7419.6519.7419.6719.48 2016QAM1022.5422.5222.7122.7222.672016QAM1020.0019.9520.0520.0019.85 2016QAM14922.6522.5122.5622.7822.532016QAM14919.9020.0219.8719.8019.71 2016QAM19922.5022.4922.6122.6222.692016QAM19919.8819.8019.9319.8919.74 2016QAM50021.5521.4921.6921.6221.652016QAM50018.6618.8218.7418.8118.68 2016QAM502421.4021.4121.5721.6421.602016QAM502418.6818.6918.7718.6518.49 2016QAM505021.5421.3821.6121.5121.522016QAM505018.6618.5918.7918.5218.43 2016QAM100021.6021.4321.4321.4621.452016QAM100018.6918.6318.7318.6718.53 2064QAM1021.6521.5621.7321.5821.652064QAM1018.8618.8718.9118.7018.77 2064QAM14921.5921.5121.5821.4021.602064QAM14918.8618.7818.8218.7618.69 2064QAM19921.4421.5721.4121.4821.512064QAM19918.6718.6418.8318.7418.55 2064QAM50020.4420.5120.7020.5920.582064QAM50018.6618.6618.8018.7018.52 2064QAM502420.36 20.5220.5620.4720.582064QAM502418.5518.6918.6718.6818.56 2064QAM505020.5720.4920.4720.4720.532064QAM505018.7118.5618.6618.5718.47 2064QAM100020.3620.3320.4620.3420.352064QAM100018.6618.5618.7418.6018.42 20256QAM1018.3418.4618.5618.3218.3920256QAM1015.6715.6115.6815.5515.40 20256QAM14918.3018.4018.4618.4618.3520256QAM14915.5515.5115.5715.5715.61 20256QAM19918.3818.5118.3418.2918.2820256QAM19915.5515.4715.3715.3515.45 20256QAM50017.2817.3517.6317.4117.3820256QAM50014.4014.4714.7314.5514.45 20256QAM502417.3917.3117.4117.5417.4620256QAM502414.4614.5014.6314.6214.58 20256QAM505017.3817.5317.5017.2717.2920256QAM505014.4514.6114.4414.3614.42 20256QAM100017.3717.4217.5017.3817.2820256QAM100014.4514.4914.6514.3314.30 39725401734062041068415155531555820559905616056665 2503.52548.325932637.82682.53557.53608362536423692.5 15QPSK1023.4623.4323.5023.4223.4115QPSK1021.0921.1221.1521.1021.02 15QPSK13723.3123.2923.4323.2423.4115QPSK13720.5920.6120.6120.6420.63 15QPSK17423.3423.4423.4723.3023.3115QPSK17420.6520.6320.6520.4520.59 15QPSK36022.5322.5222.5422.4722.4815QPSK36020.1920.1020.2220.0519.95 15QPSK362022.3422.3222.5422.3322.3915QPSK362019.6419.6319.6919.7319.62 15QPSK363922.4722.2722.5022.3222.4615QPSK363919.6419.5519.7719.5819.42 15QPSK75022.3922.4122.4722.5122.2815QPSK75019.6619.5719.6619.5919.40 1516QAM1022.4522.4322.6222.6322.581516QAM1019.9219.8719.9719.9219.77 1516QAM13722.5622.4222.4722.6922.441516QAM13719.8219.9419.7919.7219.63 1516QAM17422.4122.4022.5222.5322.601516QAM17419.8019.7219.8519.8119.66 1516QAM36021.4621.4021.6021.5321.561516QAM36018.5818.7418.6618.7318.60 1516QAM362021.3121.3221.4821.5521.511516QAM362018.6018.6118.6918.5718.41 1516QAM363921.4521.2921.5221.4221.431516QAM363918.5818.5118.7118.4418.35 1516QAM75021.5121.3421.3421.3721.361516QAM75018.6118.5518.6518.5918.45 15 64QAM1021.5621.4721.6421.4921.561564QAM1018.7818.7918.8318.6218.69 1564QAM13721.5021.4221.4921.3121.511564QAM13718.7818.7018.7418.6818.61 1564QAM17421.3521.4821.3221.3921.421564QAM17418.5918.5618.7518.6618.47 1564QAM36020.3520.4220.6120.5020.491564QAM36018.5818.5818.7218.6218.44 1564QAM362020.2720.4320.4720.3820.491564QAM362018.4718.6118.5918.6018.48 1564QAM363920.4820.4020.3820.3820.441564QAM363918.6318.4818.5818.4918.39 1564QAM75020.2720.2420.3720.2520.261564QAM75018.5818.4818.6618.5218.34 15256QAM1018.2518.3718.4718.2318.3015256QAM1015.5915.5315.6015.4715.32 15256QAM13718.2118.3118.3718.3718.2615256QAM13715.4715.4315.4915.4915.53 15256QAM17418.2918.4218.2518.2018.1915256QAM17415.4715.3915.2915.2715.37 15256QAM36017.1917.2617.5417.3217.2915256QAM36014.3214.3914.6514.4714.37 15256QAM362017.3017.2217.3217.4517.3715256QAM362014.3814.4214.5514.5414.50 15256QAM363917.2917.4417.4117.1817.2015256QAM363914.3714.5314.3614.2814.34 15256QAM75017.2817.3317.4117.2917.1915256QAM75014.3714.4114.5714.2514.22 39700401604062041080415405529055815559905616556690 2501254725932639268535553607.536253642.53695 10QPSK1023.3823.3523.4223.3423.3310QPSK1021.0021.0321.0621.0120.93 10QPSK12523.2323.2123.3523.1623.3310QPSK12520.5020.5220.5220.5520.54 10QPSK14923.2623.3623.3923.2223.2310QPSK14920.5620.5420.5620.3620.50 10QPSK25022.4522.4422.4622.3922.4010QPSK25020.1020.0120.1319.9619.86 10QPSK251222.2622.2422.4622.2522.3110QPSK251219.5519.5419.6019.6419.53 10QPSK252522.3922.1922.4222.2422.3810QPSK252519.5519.4619.6819.4919.33 10QPSK50022.3122.3322.3922.4322.2010QPSK50019.5719.4819.5719.5019.31 1016QAM1022.3722.3522.5422.5522.501016QAM1019.8319.7819.8819.8319.68 1016QAM12522.4822.3422.3922.6122.361016QAM12519.7319.8519.7019.6319.54 1016QAM14922.3322.3222.4422.4522.52 1016QAM14919.71 19.6319.7619.7219.57 1016QAM25021.3821.3221.5221.4521.481016QAM25018.4918.6518.5718.6418.51 1β¦
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 4 | 96 | 3.60 GHz - 3.65 GHz | 140.00 mW | 96M2W7D | 0.006 ppm |
5G/LTE CBRS USB-C Dongle
Equipment Class
CBE - Citizens Band End User Devices