Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 08, 2025
Application Purpose
Original Equipment
Equipment Note
ZOOM TKL DYNA
Frequency Range
2402.00000000 - 2480.00000000
Company
Wuhan Wuque Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)this devicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuantto Part15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmful interferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcanradiateradiofrequencyenergy and, ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradio communications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation. Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedby turningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneor moreofthefollowingmeasures: --Reorientorrelocatethereceivingantenna. --Increasetheseparationbetweentheequipmentandreceiver. --Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected. --Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Warning:changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidthe user' sauthoritytooperatetheequipment ThedeviceshasbeenevaluatedtomeetgeneralRFexposurerequirementthedevicecanbeusedinportable exposureconditionwithoutrestriction

Attestation Statements

WuhanWuqueTechnologyCo.,Ltd 307,BuildingT5,GuocaiCenter,DonghuHightechZone, WuhanCity,HubeiProvinc,China AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:Sep.5,25 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2BE9O-87KEY WuhanWuqueTechnologyCo.,Ltd(“theapplicant”)certifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredList,establishedpursuantto§1.50002of referencechapter,asanentityproducing“covered”communicationequipment.Theequipmentfor whichauthorizationissoughtisnot“covered”telecommunicationsequipmentandvideosurveillance equipmentproducedbyentitiesidentifiedontheCommission’sCoveredListthatprohibitedfrom receivinganequipmentauthorizationpursuanttosection§2.903oftheFCCrules. Sincerelyyours, ApplicantSignature PrintedName:FanYang Title:Manager Address:307,BuildingT5,GuocaiCenter,DonghuHightechZone,WuhanCity,HubeiProvinc,China Email:[email protected]

Attestation Statements

WuhanWuqueTechnologyCo.,Ltd 307,BuildingT5,GuocaiCenter,DonghuHightechZone, WuhanCity,HubeiProvinc,China 1|Page AttestationStatements To:FederalCommunicationsCommissionDate:Sep.5,25 7435OaklandMillsRoad, Columbia,MD21046,USA Subject:AttestationofCompliancewithFCCCoveredListSoftwareRequirements FCCID:[2BE9O-87KEY] ProductName:[ZOOMTKLDYNA] Thisletterservesasanattestationthattheequipmentidentifiedabove☐is/☒isnot(selectone)"covered" softwareasdefinedundertheFederalCommunicationsCommission(FCC)CoveredListrequirements,as outlinedinFCC22-84andKDB986446. Specifically,theundersignedcertifiesthattheequipmentforwhichauthorizationissought: 1.Doesnotcontaincybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab, Inc.oranyofitssuccessors,assignees,parents,subsidiaries,affiliates,oranyentitythathasrebranded orrelabeledsoftwareproducedbytheaforementionedentities. 2.Doesnothavethecapabilitytostore,run,ordeliveranysoftwareidentifiedontheFCCCoveredList, includingbutnotlimitedtocybersecurityandanti-virussoftware. Tosupportthisattestation,theappendixevaluationdocumentationhasbeenpreparedandisincludedinthe certificationfiling. Thisattestationisbasedonathoroughevaluationofthedevice'sdesign,functionality,andsoftware environment.Theundersignedaffirmsthattheinformationprovidedisaccurateandcompletetothebestof theirknowledge. Sincerelyyours, ApplicantSignature PrintedName:FanYang Title:Manager Address:307,BuildingT5,GuocaiCenter,DonghuHightechZone,WuhanCity,HubeiProvinc,China Tel.:18071089523 Email:[email protected] EvaluationregardingtotheCoveredListSoftware: Compliance Methodology EvaluationProcessResults WuhanWuqueTechnologyCo.,Ltd 307,BuildingT5,GuocaiCenter,DonghuHightechZone, WuhanCity,HubeiProvinc,China 2|Page Deviceis Inherent compliance ☒ TheChipset(s)usedislimitedtorun theCybersecurityoranti-virus software. Compliance ☒ TheMemoryusedislimitedtorunthe Cybersecurityoranti-virussoftware. Compliance ☒ Thereisstoragecapacitylimitationfor storeorinstalltheCybersecurityor anti-virussoftware. Compliance ☒ Operatingsystemusedislimitedto run,installordelivertheCybersecurity oranti-virussoftware. Compliance Deviceisnot Inherent compliance ☐ EvaluationBasedonSoftware BillofMaterials(SBoM) ☐ EvaluationBasedonScanfor Softwareonthedevice ☐ EvaluationBasedonFilesystemscan ☐ EvaluationBasedonRunning softwarecheck

Attestation Statements

WuhanWuqueTechnologyCo.,Ltd 307,BuildingT5,GuocaiCenter,DonghuHightechZone, WuhanCity,HubeiProvinc,China U.S.AgentLetterofAttestation To:FederalCommunicationsCommission 7435OaklandMillsRoad,Columbia,MD21046,USA Date:Sep.5,25 Ref: AttestationStatement–Part 2.911(d)(7)filing FCCID:[2BE9O-87KEY] [WuhanWuqueTechnologyCo.,Ltd](“theapplicant”)certifiesthat,asofthedateofthefilingof theapplication,[LOBOSIOWAINC](“theagent”)isourdesignatedU.S.agentforserviceof processfortheabovereferenceFCCID.Theapplicantacceptstomaintainanagentforserviceof processintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolvingtheequipment, whicheverislater.TheapplicantfurtheracknowledgesitisourresponsibilitytoinformtheFCC whenevertheagentinformationchanges. [LOBOSIOWAINC]("theagent)understanditistheagent'sobligationtoacceptserviceofprocess intheUnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddress. DesignatedU.S.Agent CompanyName:LOBOSIOWAINC FRN:0036413961 GC:N/A Address:4623BittercreekDrColoradoSpringsco 80922Us Signature: ContactPerson:HarleyLi Tel:(818)818-0538Email:[email protected] Applicant CompanyName: WuhanWuqueTechnologyCo.,Ltd FRN:0035050855 GC:2BE9O Address:307,BuildingT5,GuocaiCenter,Donghu HightechZone,WuhanCity,HubeiProvinc,China Signature: ContactPerson: FanYang Tel: 18071089523 Email:[email protected]

Cover Letter(s)

WuhanWuqueTechnologyCo.,Ltd 307,BuildingT5,GuocaiCenter,DonghuHightechZone, WuhanCity,HubeiProvinc,China 9/5/2025 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestfor:FCCID:2BE9O-87KEY PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestpermanent confidentialtreatmentoftheexhibitsaccompanyingthiscertificationapplicationasoutlinedbelow: BlockDiagram Schematics OperationalDescription Theaboveexhibitscontaintradesecretsand/orproprietaryinformationthatarenotpubliclyavailableand materialsthattheApplicanthasspentconsiderableeffortsindeveloping.Publicdisclosureofthesemay beharmfultotheApplicantandgiveanunfairadvantagetocompetitorsonthemarket. Sincerely, (Signature) Title:Manager Address:307,BuildingT5,GuocaiCenter,DonghuHightechZone,WuhanCity,HubeiProvinc,ChinaTel.: 18071089523 Email:18071089523

Cover Letter(s)

WuhanWuqueTechnologyCo.,Ltd 307,BuildingT5,GuocaiCenter,DonghuHightechZone, WuhanCity,HubeiProvinc,China Date:Sep.5,25 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorizationforFCCID:2BE9O-87KEY I,theundersigned,herebyauthorize(FluxComplianceServiceLaboratory)toactonourbehalfinall mattersrelatingtothisapplicationforequipmentcertification. Anyactcarriedoutby(FluxComplianceServiceLaboratory)shallhavethesameeffectasourownandI acknowledgethatallresponsibilityforcomplyingwiththetermsandconditionsofcertification,as specifiedbyDERYCOMCERTIFICATIONSERVICES,INC.,stillresideswith(WuhanWuqueTechnology Co.,Ltd). WecertifythatwearenotsubjecttoadenialoffederalbenefitsthatincludesFCCbenefitspursuantto Section5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862,andthatnopartytotheapplication,as definedin47CFR§1.2002(b),issubjecttoadenialoffederalbenefitsthatincludesFCCbenefits pursuanttothatsection. Sincerely, ApplicantSignature: PrintedName:FanYang Title:Manager Address:307,BuildingT5,GuocaiCenter,DonghuHightechZone,WuhanCity,HubeiProvinc,China Tel.:18071089523 Email:18071089523

External Photos

Page1of4ReportNo.:FCS202507312 Externalphotos Photo1 Photo2 Page2of4ReportNo.:FCS202507312 Photo3 Photo4 Page3of4ReportNo.:FCS202507312 Photo5 Photo6 Page4of4ReportNo.:FCS202507312 Photo7

ID Label/Location Info

LabelandLabelLocation FCCID:2BE9O-87KEY L*W:10mm*5mm labelandWhitefont

Internal Photos

Page1of3ReportNo.:FCS202507312 Internalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202507312 Photo3 Photo4 Page3of3ReportNo.:FCS202507312 Photo5 ANT Photo6

RF Exposure Info

FCS202507312W03 FCCRFExposure EUTDescription:ZOOMTKLDYNA ModelNo.:87key FCCID:2BE9O-87KEY Equipmenttype:Portabledevices AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1093  Unless specificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1-gheadorbody and10-gextremitySARevaluationforgeneralpopulationexposureconditions,bymeasurementor numericasimulation,isnotrequiredwhenthecorrespondingSARTestExclusion Thresholocondition(s),listedbelow,is(are)satisfied. For100MHzto6GHzandtestseparationdistances<50mm,the1-gand10-gSARtestexclusion thresholdsaredeterminedbythefollowing: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparation distancemm)]·[vfGHz)]<3.0for1-gSAR,ands7.5for10-gextremitySAR,where f(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation Theresultisroundedtoonedecimalplaceforcomparison BLE conducted power (dBm) Maxtune- up(mW) Frequency(MHz)Min. distance(mm) Calc. thresholds limit -0.26 0.9419240250.29203.0 1.08 1.2823244050.40063.0 0.58 1.1429248050.36003.0 2.4G EIRP=EMeas+20log(dmeas)-104.7 EIRPistheequivalentisotropicallyradiatedpower, E M easindBmisthefieldstrengthoftheemissionatthemeasurementdistance,indBuV/m dMeasisthemeasurementdistance,inm Field strength(dBuV/m) EIRP(dBm) Max tune- up(mW) Frequency(MHz)Min. distance(mm) Calc. thresholds limit 95.410.251.05925240250.328333.0 93.94-1.220.75509242650.235223.0 96.751.591.44212248050.454213.0 Conclusion:NoSARisrequired

Test Report

FCCTestReport ReportNo:FCS202507312W01 Issuedfor Applicant: WuhanWuqueTechnologyCo.,Ltd Address: 307,BuildingT5,GuocaiCenter,DonghuHightechZone, WuhanCity,HubeiProvinc,China ProductName: ZOOMTKLDYNA BrandName: ModelName: 87key SeriesModel: N/A FCCID: 2BE9O-87KEY IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial, SongshanlakeDongguan Tel:0769-27280901Fax:0769-27280901http://www.FCS-lab.com Page 2 of42ReportNo.:FCS202507312W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:0769-27280901Fax:0769-27280901http://www.FCS-lab.com TESTRESULTCERTIFICATION Applicant’sName......................: WuhanWuqueTechnologyCo.,Ltd Address......................................: 307,BuildingT5,GuocaiCenter,DonghuHightechZone, WuhanCity,HubeiProvinc,China Manufacture'sName................: DongguanWuquePrecisionTechnologyCo.,Ltd. Address......................................: No.4,QiantanStreet,ShipaiTown,DongguanCity,Guangdong Province,China ProductDescription ProductName ........................... :ZOOMTKLDYNA BrandName ............................... : ModelName .............................. :87key SeriesModel .............................. :N/A TestStandards..........................:FCCRulesandRegulationsPart15SubpartC,Section247 TestProcedure .......................... :ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedbyFluxComplianceServiceLaboratory,thetestresults showthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditis applicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFluxCompliance ServiceLaboratory,thisdocumentmaybealteredorrevisedbyFluxComplianceServiceLaboratory, personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests . :July.21,2025~July.28,2025 DateofIssue.................................:Aug.18,2025 TestResult.....................................:Pass Testedby: (MikeTan) Reviewedby : (NelsWang) Approvedby: ( JackWang ) Page 3 of42ReportNo.:FCS202507312W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:0769-27280901Fax:0769-27280901http://www.FCS-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS..............................................................................................6 1.1TESTFACTORY................................................................................................................7 1.2MEASUREMENTUNCERTAINTY.....................................................................................7 2.GENERALINFORMATION.......................................................................................................8 2.1GENERALDESCRIPTIONOFTHEEUT..........................................................................8 2.2BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED.............10 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS.................11 2.4EQUIPMENTSLIST.........................................................................................................12 3.6DBBANDWIDTH..................................................................................................................13 3.1Limit..................................................................................................................................13 3.2TestProcedure.................................................................................................................13 3.3Testsetup.........................................................................................................................13 3.4Testresults.......................................................................................................................14 3.5OriginalTestData.............................................................................................................15 4.CONDUCTEDOUTPUTPOWER...........................................................................................18 4.1LIMIT................................................................................................................................18 4.2TESTPROCEDURE........................................................................................................18 4.3TESTSETUP...................................................................................................................18 4.4TESTRESULTS...............................................................................................................18 5.BANDEDGEANDSPURIOUS(CONDUCTED)....................................................................19 5.1LIMIT................................................................................................................................19 5.2TESTPROCEDURE........................................................................................................19 5.3TESTSETUP...................................................................................................................19 5.4TESTRESULTS...............................................................................................................20 5.5Originaltestdata..............................................................................................................20 6.POWERSPECTRALDENSITY..............................................................................................24 6.1LIMIT................................................................................................................................24 6.2TESTPROCEDURE........................................................................................................24 6.3TESTSETUP...................................................................................................................24 6.4TESTRESULTS........


Text truncated - open the document above for the full version.

Test Report

Page 1 of 13 Antenna Test Report Report No.: AGC17069250701PA01 PRODUCT DESIGNATION : Mechanical Keyboard BRAND NAME : N/A MODEL NAME : ZOOM TKL DYNA APPLICANT : Wuque Technology Co., Ltd. DATE OF ISSUE : Jul. 11, 2025 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC17069250701PA01 Page 2 of 13 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Jul. 11, 2025 Valid Initial release Report No.: AGC17069250701PA01 Page 3 of 13 TABLE OF CONTENTS 1. PRODUCT INFORMATON ..................................................................................................................... 4 2. TEST FACILITY ..................................................................................................................................... 5 3. TEST EQUIPMENT LIST ....................................................................................................................... 5 4. MEASUREMENT UNCERTAINTY ......................................................................................................... 5 5. TEST SUMMARY LIST .......................................................................................................................... 5 6. TEST SETUP ......................................................................................................................................... 6 7. TEST RESULTS ..................................................................................................................................... 7 7.1. VSWR .............................................................................................................................................. 7 7.2. GAIN AND EFFICIENCY ................................................................................................................. 8 7.3. RADIATION PATTERN .................................................................................................................... 9 APPENDIX A: PHOTOGRAPHS OF TEST SETUP ................................................................................ 11 APPENDIX B: PHOTOGRAPHS OF EUT ............................................................................................... 12 Report No.: AGC17069250701PA01 Page 4 of 13 1. PRODUCT INFORMATON General information Applicant Wuque Technology Co., Ltd. Address Room 307, Building T5, China Procurement Center, Intersection of Gaoxin Avenue and Guanggu 6th Road, East Lake New Technology Development Zone, Wuhan, Hubei Province,China Manufacturer Wuque Technology Co., Ltd. Address Room 307, Building T5, China Procurement Center, Intersection of Gaoxin Avenue and Guanggu 6th Road, East Lake New Technology Development Zone, Wuhan, Hubei Province,China Factory Wuque Technology Co., Ltd. Address Room 307, Building T5, China Procurement Center, Intersection of Gaoxin Avenue and Guanggu 6th Road, East Lake New Technology Development Zone, Wuhan, Hubei Province,China Product Designation Mechanical Keyboard Brand Name N/A Test Model ZOOM TKL DYNA Series Model N/A Difference Description N/A Date of test Jul. 08, 2025 Report Template AGCRT-ER-PA/V1.0 Technical information Frequency Range 2400-2500MHz Test Frequencies 2400MHz, 2410MHz, 2420MHz, 2430MHz, 2440MHz, 2450MHz, 2460MHz, 2470MHz, 2480MHz, 2490MHz, 2500MHz Antenna Type PCB antenna Dimensions 9.5mm*7.1mm Impedance 50Ω Maximum test values Gain: -3.95dBi; Efficiency:8.197%; VSWR: 1.095 U The above equipment was tested by Attestation of Global Compliance (Shenzhen) Co., Ltd. The test results of this report relate only to the tested sample identified in this report. Prepared By Thea Huang (Project Engineer) Jul. 11, 2025 Reviewed By Bibo Zhang (Reviewer) Jul. 11, 2025 Approved By Angela Li (Authorized Officer) Jul. 11, 2025 Report No.: AGC17069250701PA01 Page 5 of 13 2. TEST FACILITY 3. TEST EQUIPMENT LIST Equipment Manufacturer Model Cal. Date Cal. Due ANTENNA MEASUREMENT SYSTEM ETS-Lindgren AMS-8600 Nov. 27, 2024 Nov. 26, 2025 Network Analyzer R&S ZVL-6 Jul. 24, 2024 Jul. 23, 2025 Test software ETS-Lindgren EMQuest (Ver V1.12) N/A N/A 4. MEASUREMENT UNCERTAINTY The uncertainty is calculated using the methods suggested in the “Guide to the Expression of Uncertainty in measurement” (GUM) published by CISPR and ANSI. - Uncertainty of VSWR, Uc = ±1.5dB - Uncertainty of Gain, Uc = ±0.8dB 5. TEST SUMMARY LIST NO. Test item Remark 1 VSWR -- 2 Gain and efficiency -- 3 Radiation pattern -- Test Site Attestation of Global Compliance (Shenzhen) Co., Ltd Location 1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Report No.: AGC17069250701PA01 Page 6 of 13 6. TEST SETUP Report No.: AGC17069250701PA01 Page 7 of 13 7. TEST RESULTS 7.1. VSWR Frequency(MHz) VSWR 2400 1.080 U 2450 1.044 U 2480 1.082 U 2420 1.095 U Report No.: AGC17069250701PA01 Page 8 of 13 7.2. GAIN AND EFFICIENCY Frequency(MHz) Efficiency(dB) Efficiency(%) Gain(dBi) 2400 -11.891 6.470 -5.133 2410 -12.021 6.279 -5.227 2420 -12.261 5.942 -5.336 2430 -12.061 6.222 -4.982 2440 -11.928 6.415 -4.711 2450 -11.866 6.508 -4.496 2460 -11.687 6.781 -4.316 2470 -11.676 6.798 -4.477 2480 -11.289 7.433 -4.261 2490 -11.020 7.907 -4.090 2500 -10.863 8.197 -3.951 Report No.: AGC17069250701PA01 Page 9 of 13 7.3. RADIATION PATTERN 2D POLAR RADIATION PATTERN FREQUENCY=2400MHZ FREQUENCY=2450MHZ FREQUENCY=2500MHZ Report No.: AGC17069250701PA01 Page 10 of 13 3D RADIATION PATTERN FREQUENCY=2400MHZ FREQUENCY=2450MHZ FREQUENCY=2500MHZ Report No.: AGC17069250701PA01 Page 11 of 13 APPENDIX A: PHOTOGRAPHS OF TEST SETUP Report No.: AGC17069250701PA01 Page 12 of 13 APPENDIX B: PHOTOGRAPHS OF EUT Report No.: AGC17069250701PA01 Page 13 of 13 Conditions of Issuance of Test Reports 1. All samples and goods are accepted by the Attestation of Global Compliance (Shenzhen) Co., Ltd (the “Company”) solely for testing and reporting in accordance with the following terms and condition


Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of2ReportNo.:FCS202507312 RE Page 2 of2ReportNo.:FCS202507312 CE

Contact Information

Applicant

Yang Fan
[email protected]Fax: N/A

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.28 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.