Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Vantron Technology, Inc. Covered Equipment Certification Attestation Letter 7/9/2026 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2BEA6AH8108 Vantron Technology, Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Vantron Technology, Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Vantron Technology, Inc. (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Signed: Printed name: Chengyun Wang Title: V.P Company Name: Vantron Technology, Inc. Address: 48434 Milmont Drive Fremont, CA 94538-7324, USA Phone: (650) 422-3128 E-Mail: [email protected] Date: 7/9/2026
Vantron Technology, Inc. U.S. Agent Designation for Service of Process - Certification Attestation Letter Vantron Technology, Inc. 48434 Milmont Drive Fremont, CA 94538-7324, USA Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA 7/9/2026 Attestation Statement according to 2.911(d)(7) FCC ID: 2BEA6AH8108 TO WHOM IT MAY CONCERN: We, Vantron Technology, Inc.designate ourselves to act as U.S. agent for service of process. Vantron Technology, Inc. hereby acknowledges the obligation of the U.S. agent for service of process. Further Vantron Technology, Inc. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Sincerely Applicant Signed/ Designated Agent Signed: Signature: Company name: Vantron Technology, Inc. FRN: 0033500448 Address: 48434 Milmont Drive Fremont, CA 94538-7324, USA Printed name: Chengyun Wang Title: V.P Phone: (650) 422-3128 E-Mail: [email protected] Date: 7/9/2026
Label location
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC RF EXPOSURE REPORT For Wi-Fi Halow Module MODEL NUMBER: VT-MOB-AH-8108 FCC ID: 2BEA6AH8108 REPORT NUMBER: 4792245260-1-RF-2 ISSUE DATE: July 1, 2026 Prepared for Vantron Technology, Inc. 48434 Milmont Drive Fremont, CA 94538-7324, USA Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4792245260-1-RF-2 Page 2 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 July 1, 2026 Initial Issue REPORT NO.: 4792245260-1-RF-2 Page 3 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. REQUIREMENT ................................................................................................................. 6 REPORT NO.: 4792245260-1-RF-2 Page 4 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: Vantron Technology, Inc. Address: 48434 Milmont Drive Fremont, CA 94538-7324, USA Manufacturer Information Company Name: Vantron Technology, Inc. Address: 48434 Milmont Drive Fremont, CA 94538-7324, USA EUT Information EUT Name: Wi-Fi Halow Module Model: VT-MOB-AH-8108 Sample Received Date: May 8, 2026 Sample Status: Normal Sample ID: 9723112 Date of Tested: May 8, 2026 to July 1, 2026 APPLICABLE STANDARDS STANDARD TEST RESULTS 447498 D04 Interim General RF Exposure Guidance v01 PASS Prepared By: Checked By: Fanny Huang Kebo Zhang Project Engineer Operations Leader Approved By: Stephen Guo Operations Manager REPORT NO.: 4792245260-1-RF-2 Page 5 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with 47 CFR FCC Part 1 Subpart I, section 1.1307 and KDB 447498 D04 Interim General RF Exposure Guidance v01. 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 4102.01) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1187) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. Has been recognized to perform compliance testing on equipment subject to the Commission's Declaration of Conformity (DoC) and Certification rules. ISED (Company No.: 21320) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been registered and fully described in a report filed with ISED. The Company Number is 21320 and the test lab Conformity Assessment Body Identifier (CABID) is CN0046. VCCI (Registration No.: C-20202, G-20240, R-20248 and T-20202) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with VCCI, the Membership No. is 3793. Facility Name: Chamber E, the VCCI registration No. is G-20240 and R-20248 Shielding Room F, the VCCI registration No. is C-20202 and T-20202 Note 1: All tests measurement facilities use to collect the measurement data are located at Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China. Note 2: The test anechoic chamber in UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch had been calibrated and compared to the open field sites and the test anechoic chamber is shown to be equivalent to or worst case from the open field site. Note 3: For below 30 MHz, lab had performed measurements at test anechoic chamber and comparing to measurements obtained on an open field site. And these measurements below 30 MHz had been correlated to measurements performed on an OFS. REPORT NO.: 4792245260-1-RF-2 Page 6 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 4. REQUIREMENT LIMIT AND CALCULATION METHOD According to 447498 D04 Interim General RF Exposure Guidance v01, 2.1.4 MPE-Based Exemption An alternative to the SAR-based exemption is provided in § 1.1307(b)(3)(i)(C), for a much wider frequency range, from 300 kHz to 100 GHz, applicable for separation distances greater or equal to λ/2π, where λ is the free-space operating wavelength in meters. The MPE-based test exemption condition is in terms of ERP,…
Text truncated - open the document above for the full version.
东莞市一佳电子通讯科技有限公司 Dongguan YiJia Electronics Communication Technology Co.,Ltd. 规格承认书 SPECIFICATION FOR APPROVAL 日期 Date 2024/02/29 编号 File No 24022901 版本 Revision 1.0 客户 CUSTOMER: 成都万创 客户料号 CUSTOMER NO: 品名 850950MHz Antenna 品名 PART NAME: 850-950MHz Antenna 供方料号 SUPPLIER NO: YJS01.042.058.102A 送样日期 Date: 送样数量Q‘TY: 客户确认CUSTOMER APPROVED BY APPROVALCHIEFSUPERVISOR 供方确认SUPPLIER SIGNATURE APPROVALCHECKDESIGN add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 APPROVALCHECKDESIGN ChenGuoqiangXieLiChenXingyi YJ-RD-F04-A Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Com munity, Chang'an Town, Dongguan, Guangdong Pr ovince, China 承认书项目表 NO . 内容 (Contents) 页数 (Number of Pa ge) 页码 (Page Code)g 1 承认书封面 (Spec Cover) 11 2 承认书项目表(Spec Item ) 12 3 工程成品图(Drawing) 133 工程成品图(Drawing) 13 4 天线规格(Antenna Specification) 14 5 S参数测试 (S Parameter ) 15 6 无源测试 (Passive Test ) 56 ~ 10 7 方向图(Radiation Pattern) 411 ~ 14 8 天线装配图(Antenna Profile) 215 ~ 16 9 材质证明(Material Certificate ) 2017 ~ 36 10 RoHS报告(RoHS Test Report ) **** 11N/AN/AN/A add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 12--- 13--- Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Community, Chang'an Town, Dongguan, Guangdong Pr ovince, China 天线规格 Antenna Specification Electrical Properties Frequency850-950MHz Impedance50 Ohm Nominal V.S.W.R2.5 Max Gain2.6 dBi RadiationOmni-directional PolarizationLinear Physical Properties ConnectorSMA Male Reverse Cable TypeNone Cable LengthNone Cable ColorNone add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Operating Temp.-40 ~ +85 ̊C Storage Temp.-40~ +85 ̊C Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Community, Chang'an Town, Dongguan, Guangdong Pr ovince, China Antenna Performance TestAntenna Performance Te s t Agilent E5071C S Parameter Test // 850-950 MHz Antenna add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Community, Chang'an Town, Dongguan, Guangdong Pr ovince, China Antenna Passive TestAntenna Passive Te s t Z Y X Y X Z add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Community, Chang'an Town, Dongguan, Guangdong Pr ovince, China Passive Test For 850-950MHz Antenna FreqEffiEffiGain (MHz)(%)(dB)(dBi) 85067.6 -1.71.5 85572.8 -1.42.0 86073.8 -1.31.9 86576.7 -1.22.3 87079.1 -1.02.5 87580.2 -1.02.6 88082.2 -0.92.6 88578.3 -1.12.2 add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 89078.2 -1.11.9 89572.3 -1.41.5 Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Community, Chang'an Town, Dongguan, Guangdong Pr ovince, China Passive Test For 850-950MHz Antenna FreqEffiEffiGain (MHz)(%)(dB)(dBi) 90084.9 -0.72.0 90185.3 -0.71.9 90285 1071990285.1-0.71.9 90384.3 -0.71.9 90482.8 -0.81.9 90580.9 -0.91.8 90679.6 -1.01.8 90778.7 -1.01.8 90878.3 -1.11.8 90978.5 -1.11.8 91079.1 -1.01.8 91178.7 -1.01.8 91278 71018 add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 91278.7-1.01.8 91378.3 -1.11.9 91477.8 -1.11.9 Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Community, Chang'an Town, Dongguan, Guangdong Pr ovince, China Passive Test For 850-950MHz Antenna FreqEffiEffiGain (MHz)(%)(dB)(dBi) 91576.9 -1.11.9 91676.7 -1.21.9 91776 4-121991776.4 1.21.9 91875.9 -1.21.9 91975.3 -1.21.9 92075.2 -1.22.0 92174.6 -1.31.9 92274.8 -1.31.9 92375.2 -1.21.9 92475.3 -1.21.9 92575.3 -1.21.9 92675.7 -1.21.9 92775.5 -1.21.9 add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 92875.3 -1.21.9 92975.2 -1.22.0 93075.0 -1.32.0 Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Community, Chang'an Town, Dongguan, Guangdong Pr ovince, China Passive Test For 850-950MHz Antenna FreqEffiEffiGain (MHz)(%)(dB)(dBi) 93255.5 -2.62.2 93456.6 -2.52.4 93658.1 -2.42.6 93858.1 -2.42.6 94056.1 -2.52.5 94254.5 -2.62.4 94454.8 -2.62.4 94656.1 -2.52.6 add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 94856.2 -2.52.6 95055.2 -2.62.5 Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Community, Chang'an Town, Dongguan, Guangdong Pr ovince, China Radiation Pattern For 850-950MHzAntenna(850MHz) add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Community, Chang'an Town, Dongguan, Guangdong Pr ovince, China Radiation Pattern For 850-950MHzAntenna(915MHz) add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Community, Chang'an Town, Dongguan, Guangdong Pr ovince, China Radiation Pattern For 850-950MHzAntenna(950MHz) add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Community, Chang'an Town, Dongguan, Guangdong Pr ovince, China Radiation Pattern For 850-950MHz Antenna Phi 0° Phi 90° Theta 90° add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 eta90 Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Community, Chang'an Town, Dongguan, Guangdong Pr ovince, China 850-950 MHzMHz Antenna add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Community, Chang'an Town, Dongguan, Guangdong Pr ovince, China 850950MH A t850-950MHz Antenna add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Yuanfu Industrial Park, No. 59 Muyu Road, Shatou Community, Chang'an Town, Dongguan, Guangdong Pr ovince, China
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC 47 CFR PART 15 SUBPART C ISED RSS-247 Issue 4 TEST REPORT For Wi-Fi Halow Module MODEL NUMBER: VT-MOB-AH-8108 REPORT NUMBER: 4792245260-1-RF-1 ISSUE DATE: July 1, 2026 FCC ID: 2BEA6AH8108 IC: 31870-AH8108 Prepared for Vantron Technology, Inc. 48434 Milmont Drive Fremont, CA 94538-7324, USA Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4792245260-1-RF-1 Page 2 of 92 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 July 1, 2026 Initial Issue REPORT NO.: 4792245260-1-RF-1 Page 3 of 92 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Summary of Test Results Test Item Clause Limit/Requirement Result Antenna Requirement N/A FCC Part 15.203/15.247 (c) RSS-GEN Clause 6.8 Pass AC Power Line Conducted Emission ANSI C63.10-2020, Clause 6.2 FCC Part 15.207 RSS-GEN Clause 8.8 Pass Conducted Output Power ANSI C63.10-2020, Clause 11.9.2.3.1&11.9.1.2 FCC Part 15.247 (b)(3) RSS-247 Clause 6.3.2 Pass 6dB Bandwidth and 99% Occupied Bandwidth ANSI C63.10-2020, Clause 11.8.1 FCC Part 15.247 (a)(2) RSS-247 Clause 6.3.1 (a) RSS-Gen Clause 6.7 Pass Power Spectral Density ANSI C63.10-2020, Clause 11.10.5&11.10.2 FCC Part 15.247 (e) RSS-247 Clause 6.3.1 (b) Pass Conducted Band edge and spurious emission ANSI C63.10-2020, Clause 11.11 FCC Part 15.247(d) RSS-247 Clause 6.6 Pass Radiated Band edge and Spurious Emission ANSI C63.10-2020, Clause 11.12 FCC Part 15.247 (d) FCC Part 15.205/15.209 RSS-247 Clause 6.6 RSS-GEN Clause 8.9 Pass Duty Cycle ANSI C63.10-2020, Clause 11.6 None; for reporting purposes only. Pass Note: 1. For ISED, this report is also performed according to ANSI C63.10-2020 + Cor.1-2023 + C63.10a-2024 + Errata to C63.10a-2024 standards. 2. For FCC, this report is also performed according to ANSI C63.10-2020 + Cor.1-2023 standards. *This test report is only published to and used by the applicant, and it is not for evidence purpose in China. *The measurement result for the sample received is <Pass> according to <FCC 47 CFR PART 15 SUBPART C, ISED RSS-247 Issue 4> when <Simple Acceptance> decision rule is applied. Decision rule for statement of conformity: The measurement uncertainty is not taken into account for statement of conformity. REPORT NO.: 4792245260-1-RF-1 Page 4 of 92 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. CONTENTS 1. ATTESTATION OF TEST RESULTS ..................................................................................... 6 2. TEST METHODOLOGY ......................................................................................................... 7 3. FACILITIES AND ACCREDITATION ..................................................................................... 7 4. CALIBRATION AND UNCERTAINTY ................................................................................... 8 4.1. MEASURING INSTRUMENT CALIBRATION ........................................................... 8 4.2. MEASUREMENT UNCERTAINTY ............................................................................ 8 5. EQUIPMENT UNDER TEST .................................................................................................. 9 5.1. DESCRIPTION OF EUT ........................................................................................... 9 5.2. CHANNEL LIST ...................................................................................................... 10 5.3. MAXIMUM POWER ................................................................................................ 11 5.4. TEST CHANNEL CONFIGURATION ...................................................................... 11 5.5. THE WORSE CASE POWER SETTING PARAMETER .......................................... 11 5.6. WORST-CASE CONFIGURATIONS ....................................................................... 12 5.7. DESCRIPTION OF AVAILABLE ANTENNAS ......................................................... 12 5.8. SUPPORT UNITS FOR SYSTEM TEST ................................................................. 13 6. MEASURING EQUIPMENT AND SOFTWARE USED......................................................... 15 7. ANTENNA PORT TEST RESULTS ..................................................................................... 18 7.1. CONDUCTED OUTPUT POWER ........................................................................... 18 7.2. 6DB BANDWIDTH AND 99% OCCUPIED BANDWIDTH ........................................ 20 7.3. POWER SPECTRAL DENSITY .............................................................................. 22 7.4. CONDUCTED BAND EDGE AND SPURIOUS EMISSION ..................................... 24 7.5. DUTY CYCLE ......................................................................................................... 26 8. RADIATED TEST RESULTS ....................................................…
Text truncated - open the document above for the full version.
48434 Milmont Drive Fremont · Fremont, California, 94538-7324 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 903.5 MHz - 926.5 MHz | 306.90 mW |
| 2 | 15C | 905 MHz - 925 MHz | 272.90 mW |
| 3 | 15C | 906 MHz - 922 MHz | 170.61 mW |
| 4 | 15C | 908 MHz - 916 MHz | 901.57 mW |