Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Vantron Technology, Inc. Federal Comm unications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(5) Attestation FCC ID: 2BEA6G402 Grantee FRN: 0033500448 Date: 7/26/2026 1. Vantron Technology, Inc. certifies that the equipment for which authorization is sought is not "covered" equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. 2. Vantron Technology, Inc. ("the applicant") certifies that, the device does not have cy berse curity and / or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, identified on the Covered List installed on the device, nor will it be installed by the applicant anytime after certification. 3. Vantron Technology, Inc. ("the applicant") certifies that the RF device is a Industrial router. 4. Vantron Technology, Inc. cer tifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing "covered" equipment and is not an affiliate or subsidiary of an entity identified on the Covered List. Name: .Job Title: Chengyun Wang V.P Company Name: Vantron Technology, Inc.
Note:The label will be attached to the product with special glue, cannot be remove easily.
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC RF EXPOSURE REPORT For Industrial Router MODEL NUMBER: VT-M2M-G402 FCC ID: 2BEA6G402 REPORT NUMBER: 4792114926-1-RF-5 ISSUE DATE: May 15, 2026 Prepared for Vantron Technology, Inc. 48434 Milmont Drive Fremont, CA 94538-7324, USA Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4792114926-1-RF-5 Page 2 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 May 15, 2026 Initial Issue REPORT NO.: 4792114926-1-RF-5 Page 3 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. REQUIREMENT ................................................................................................................. 6 REPORT NO.: 4792114926-1-RF-5 Page 4 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: Vantron Technology, Inc. Address: 48434 Milmont Drive Fremont, CA 94538-7324, USA Manufacturer Information Company Name: Vantron Technology, Inc. Address: 48434 Milmont Drive Fremont, CA 94538-7324, USA EUT Information EUT Name: Industrial Router Model: VT-M2M-G402 Sample Received Date: March 4, 2026 Sample ID: 9492801 Date of Tested: March 4, 2026 to May 15, 2026 APPLICABLE STANDARDS STANDARD TEST RESULTS 447498 D04 Interim General RF Exposure Guidance v01 PASS Prepared By: Checked By: Fanny Huang Kebo Zhang Project Engineer Operations Leader Approved By: Stephen Guo Operations Manager REPORT NO.: 4792114926-1-RF-5 Page 5 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with 47 CFR FCC Part 1 Subpart I, section 1.1307 and KDB 447498 D04 Interim General RF Exposure Guidance v01. 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 4102.01) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1187) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. Has been recognized to perform compliance testing on equipment subject to the Commission's Declaration of Conformity (DoC) and Certification rules. ISED (Company No.: 21320) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been registered and fully described in a report filed with ISED. The Company Number is 21320 and the test lab Conformity Assessment Body Identifier (CABID) is CN0046. VCCI (Registration No.: C-20202, G-20240, R-20248 and T-20202) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with VCCI, the Membership No. is 3793. Facility Name: Chamber E, the VCCI registration No. is G-20240 and R-20248 Shielding Room F, the VCCI registration No. is C-20202 and T-20202 Note: All tests measurement facilities use to collect the measurement data are located at Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China. REPORT NO.: 4792114926-1-RF-5 Page 6 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 4. REQUIREMENT LIMIT AND CALCULATION METHOD According to 447498 D04 Interim General RF Exposure Guidance v01, 2.1.4 MPE-Based Exemption An alternative to the SAR-based exemption is provided in § 1.1307(b)(3)(i)(C), for a much wider frequency range, from 300 kHz to 100 GHz, applicable for separation distances greater or equal to λ/2π, where λ is the free-space operating wavelength in meters. The MPE-based test exemption condition is in terms of ERP, defined as the product of the maximum antenna gain and the delivered maximum time-averaged power.10 For this case, a RF source is an RF exempt device if its ERP (watts) is no more than a frequency-dependent value, as detailed tabular form in Appendix B. These limits have been derived based on the basic specifications on Maximum Permissible Exposure (MPE) considered for the FCC rules in § 1.1310(e)(1). MPE-based Exemption and f is in GHz, d is the separation distance (cm), and ERP 20cm is per Formula (B.1). REPORT NO.: 4792…
Text truncated - open the document above for the full version.
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. CFR 47 FCC PART 15 SUBPART C TEST REPORT For Industrial Router MODEL NUMBER: VT-M2M-G402 REPORT NUMBER: 4792114926-1-RF-3 ISSUE DATE: May 15, 2026 FCC ID:2BEA6G402 Prepared for Vantron Technology, Inc. 48434 Milmont Drive Fremont, CA 94538-7324, USA Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4792114926-1-RF-3 Page 2 of 90 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 May 15, 2026 Initial Issue REPORT NO.: 4792114926-1-RF-3 Page 3 of 90 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Summary of Test Results Test Item Clause Limit/Requirement Result Antenna Requirement N/A FCC Part 15.203/15.247 (c) Pass AC Power Line Conducted Emission ANSI C63.10-2020, Clause 6.2 FCC Part 15.207 Pass Conducted Output Power ANSI C63.10-2020, Clause 11.9.2.3.1 FCC Part 15.247 (b)(3) Pass 6dB Bandwidth and 99% Occupied Bandwidth ANSI C63.10-2020, Clause 11.8.1 FCC Part 15.247 (a)(2) Pass Power Spectral Density ANSI C63.10-2020, Clause 11.10.5 FCC Part 15.247 (e) Pass Conducted Band edge and spurious emission ANSI C63.10-2020, Clause 11.11 FCC Part 15.247(d) Pass Radiated Band edge and Spurious Emission ANSI C63.10-2020, Clause 11.12 FCC Part 15.247 (d) FCC Part 15.205/15.209 Pass Duty Cycle ANSI C63.10-2020, Clause 11.6 None; for reporting purposes only. Pass Note: 1. This report is also performed according to ANSI C63.10-2020 + Cor.1-2023 + C63.10a-2024 + Errata to C63.10a-2024 standards. *This test report is only published to and used by the applicant, and it is not for evidence purpose in China. *The measurement result for the sample received is <Pass> according to <CFR 47 FCC PART 15 SUBPART C> when <Simple Acceptance> decision rule is applied. Decision rule for statement of conformity: The measurement uncertainty is not taken into account for statement of conformity. REPORT NO.: 4792114926-1-RF-3 Page 4 of 90 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. CONTENTS 1. ATTESTATION OF TEST RESULTS ..................................................................................... 6 2. TEST METHODOLOGY ......................................................................................................... 7 3. FACILITIES AND ACCREDITATION ..................................................................................... 7 4. CALIBRATION AND UNCERTAINTY ................................................................................... 8 4.1. MEASURING INSTRUMENT CALIBRATION ........................................................... 8 4.2. MEASUREMENT UNCERTAINTY ............................................................................ 8 5. EQUIPMENT UNDER TEST .................................................................................................. 9 5.1. DESCRIPTION OF EUT ........................................................................................... 9 5.2. CHANNEL LIST ........................................................................................................ 9 5.3. MAXIMUM POWER .................................................................................................. 9 5.4. TEST CHANNEL CONFIGURATION ........................................................................ 9 5.5. THE WORSE CASE POWER SETTING PARAMETER .......................................... 10 5.6. WORST-CASE CONFIGURATIONS ....................................................................... 11 5.7. DESCRIPTION OF AVAILABLE ANTENNAS ......................................................... 12 5.8. SUPPORT UNITS FOR SYSTEM TEST ................................................................. 13 6. MEASURING EQUIPMENT AND SOFTWARE USED......................................................... 14 7. ANTENNA PORT TEST RESULTS ..................................................................................... 17 7.1. CONDUCTED OUTPUT POWER ........................................................................... 17 7.2. 6DB BANDWIDTH AND 99% OCCUPIED BANDWIDTH ........................................ 18 7.3. POWER SPECTRAL DENSITY .............................................................................. 20 7.4. CONDUCTED BAND EDGE AND SPURIOUS EMISSION ..................................... 22 7.5. DUTY CYCLE ......................................................................................................... 24 8. RADIATED TEST RESULTS ............................................................................................... 25 8.1. RESTRICTED BANDEDGE .................................................................................... 33 8.2. SPURIOUS EMISSIONS(1 GHZ~18 GHZ) ............................................................. 40 8.3. SPURIOUS EMISSIONS(9 KHZ~30 MHZ) ............................................................. 52 8.4. S…
Text truncated - open the document above for the full version.
REPORT NO.: 4792114926-1-RF-3 Page 84 of 90 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Tx. Spurious NVNT g 2412MHz Ant2 Emission Tx. Spurious NVNT g 2437MHz Ant1 Ref Tx. Spurious NVNT g 2437MHz Ant1 Emission REPORT NO.: 4792114926-1-RF-3 Page 85 of 90 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Tx. Spurious NVNT g 2437MHz Ant2 Ref Tx. Spurious NVNT g 2437MHz Ant2 Emission Tx. Spurious NVNT g 2462MHz Ant1 Ref REPORT NO.: 4792114926-1-RF-3 Page 86 of 90 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Tx. Spurious NVNT g 2462MHz Ant1 Emission Tx. Spurious NVNT g 2462MHz Ant2 Ref Tx. Spurious NVNT g 2462MHz Ant2 Emission REPORT NO.: 4792114926-1-RF-3 Page 87 of 90 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Tx. Spurious NVNT n20 2412MHz Ant1 Ref Tx. Spurious NVNT n20 2412MHz Ant1 Emission Tx. Spurious NVNT n20 2412MHz Ant2 Ref REPORT NO.: 4792114926-1-RF-3 Page 88 of 90 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Tx. Spurious NVNT n20 2412MHz Ant2 Emission Tx. Spurious NVNT n20 2437MHz Ant1 Ref Tx. Spurious NVNT n20 2437MHz Ant1 Emission REPORT NO.: 4792114926-1-RF-3 Page 89 of 90 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Tx. Spurious NVNT n20 2437MHz Ant2 Ref Tx. Spurious NVNT n20 2437MHz Ant2 Emission Tx. Spurious NVNT n20 2462MHz Ant1 Ref REPORT NO.: 4792114926-1-RF-3 Page 90 of 90 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Tx. Spurious NVNT n20 2462MHz Ant1 Emission Tx. Spurious NVNT n20 2462MHz Ant2 Ref Tx. Spurious NVNT n20 2462MHz Ant2 Emission END OF REPORT
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. CFR 47 FCC PART 15 SUBPART C TEST REPORT For Industrial Router MODEL NUMBER: VT-M2M-G402 REPORT NUMBER: 4792114926-1-RF-1 ISSUE DATE: May 15, 2026 FCC ID:2BEA6G402 Prepared for Vantron Technology, Inc. 48434 Milmont Drive Fremont, CA 94538-7324, USA Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4792114926-1-RF-1 Page 2 of 79 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 May 15, 2026 Initial Issue REPORT NO.: 4792114926-1-RF-1 Page 3 of 79 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Summary of Test Results Test Item Clause Limit/Requirement Result Antenna Requirement N/A FCC Part 15.203/15.247 (c) Pass AC Power Line Conducted Emission ANSI C63.10-2020, Clause 6.2 FCC Part 15.207 Pass Conducted Output Power ANSI C63.10-2020, Clause 11.9.1.2 FCC Part 15.247 (b)(3) Pass 6dB Bandwidth and 99% Occupied Bandwidth ANSI C63.10-2020, Clause 11.8.1 FCC Part 15.247 (a)(2) Pass Power Spectral Density ANSI C63.10-2020, Clause 11.10.2 FCC Part 15.247 (e) Pass Conducted Band edge and spurious emission ANSI C63.10-2020, Clause 11.11 FCC Part 15.247(d) Pass Radiated Band edge and Spurious Emission ANSI C63.10-2020, Clause 11.12 FCC Part 15.247 (d) FCC Part 15.205/15.209 Pass Duty Cycle ANSI C63.10-2020, Clause 11.6 None; for reporting purposes only. Pass Note: 1. This report is also performed according to ANSI C63.10-2020 + Cor.1-2023 + C63.10a-2024 + Errata to C63.10a-2024 standards. *This test report is only published to and used by the applicant, and it is not for evidence purpose in China. *The measurement result for the sample received is <Pass> according to <CFR 47 FCC PART 15 SUBPART C> when <Simple Acceptance> decision rule is applied. Decision rule for statement of conformity: The measurement uncertainty is not taken into account for statement of conformity. REPORT NO.: 4792114926-1-RF-1 Page 4 of 79 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. CONTENTS 1. ATTESTATION OF TEST RESULTS ..................................................................................... 6 2. TEST METHODOLOGY ......................................................................................................... 7 3. FACILITIES AND ACCREDITATION ..................................................................................... 7 4. CALIBRATION AND UNCERTAINTY ................................................................................... 8 4.1. MEASURING INSTRUMENT CALIBRATION ........................................................... 8 4.2. MEASUREMENT UNCERTAINTY ............................................................................ 8 5. EQUIPMENT UNDER TEST .................................................................................................. 9 5.1. DESCRIPTION OF EUT ........................................................................................... 9 5.2. CHANNEL LIST ........................................................................................................ 9 5.3. MAXIMUM POWER .................................................................................................. 9 5.4. TEST CHANNEL CONFIGURATION ...................................................................... 10 5.5. THE WORSE CASE POWER SETTING PARAMETER .......................................... 10 5.6. DESCRIPTION OF AVAILABLE ANTENNAS ......................................................... 10 5.7. SUPPORT UNITS FOR SYSTEM TEST ................................................................. 11 6. MEASURING EQUIPMENT AND SOFTWARE USED......................................................... 12 7. ANTENNA PORT TEST RESULTS ..................................................................................... 15 7.1. CONDUCTED OUTPUT POWER ........................................................................... 15 7.2. 6DB BANDWIDTH AND 99% OCCUPIED BANDWIDTH ........................................ 16 7.3. POWER SPECTRAL DENSITY .............................................................................. 18 7.4. CONDUCTED BAND EDGE AND SPURIOUS EMISSION ..................................... 20 7.5. DUTY CYCLE ......................................................................................................... 22 8. RADIATED TEST RESULTS ............................................................................................... 23 8.1. RESTRICTED BANDEDGE .................................................................................... 31 8.2. SPURIOUS EMISSIONS(1 GHZ~18 GHZ) ............................................................. 36 8.3. SPURIOUS EMISSIONS(9 KHZ~30 MHZ) ............................................................. 48 8.4. SPURIOUS EMISSIONS(18 GHZ~26 GHZ) ........................................................... 51 8.5. SPURIOUS…
Text truncated - open the document above for the full version.
ProductSpecification P/N: 81800U330 Rev.: B Page: 1 / 7 记录管制编号:FM-QE-E-02-00 1. Antenna Specification/天线标准 Antenna Specification/天线技术参数 Electrical Specification/电气特性 Item/目录 Specification/规格 Comment/备注 Freq. Range/频段范围 2400~2500MHz 5150~5850MHz Impedance/阻抗 50 (Ω) VSWR/驻波比 2400-2500 MHz<2.0 5150-5850 MHz<2.0 Directional/辐射方向 Omni directional Polarization/极化形式 Vertical Peak Gain/峰值增益 4.03(dBi) Test condition/测试条件 passive test(无源测试) Total Efficiency/无源效率 2400MHz~2500MHz≥65% 5150MHz~5850MHz>55% Mechanical Specification/机械指标 Antenna type/天线类型 胶棒天线 Connector Type/连接器类型 RP-SMA-J RF Cable Type/射频线型号 RG178 Connector Torque Test/连接器扭力 N/A Connector Pull Test/连接器拉力 ≥3.0Kgf Salt Spray/盐雾测试 48 (H) EnvironmentalSpecification /环境指标 Operating temp/工作温度 -40°C~+75°C Storage temp/存储温度 -40°C~+75°C ProductSpecification P/N: 81800U330 Rev.: B Page: 2 / 7 记录管制编号:FM-QE-E-02-00 2.Antenna Picture/天线图片 ProductSpecification P/N: 81800U330 Rev.: B Page: 6 / 7 记录管制编号:FM-QE-E-02-00 4.2.2 The test result of total efficiency and total gain/天线效率及增益测试结果 2400MHz-2500MHz 5150MHz-5850MHz Frequency Efficiency(%) Gain (dBi) 2400MHz 66% 0.91 2410MHz 65% 1.07 2420MHz 66% 0.99 2430MHz 68% 1.08 2440MHz 70% 1.31 2450MHz 69% 1.23 2460MHz 70% 1.27 2470MHz 73% 1.57 2480MHz 76% 1.76 2490MHz 75% 1.78 2500MHz 72% 1.59 AVG 70% 1.32 Frequency Efficiency(%) Gain (dBi) 5150MHz 78% 3.12 5200MHz 76% 3.00 5250MHz 73% 2.67 5300MHz 78% 2.96 5350MHz 63% 2.28 5400MHz 57% 1.94 5450MHz 68% 2.67 5500MHz 71% 3.35 5550MHz 72% 3.70 5600MHz 71% 3.86 5650MHz 71% 3.56 5700MHz 63% 2.90 5750MHz 62% 2.72 5800MHz 65% 3.26 5850MHz 75% 4.03 AVG 70% 3.07 ProductSpecification P/N: 81800U330 Rev.: B Page: 7 / 7 记录管制编号:FM-QE-E-02-00 4.2.3The antenna radiation pattern(2D)/天线辐射方向图(2D) 2400-2500MHz/5150-5850MHz XOY YOZ XOZ 4.2.4The antenna radiation pattern(3D)/天线辐射方向图(3D) Frequency/频点2450MHz XOY YOZ XOZ Frequency/频点5500MHz S XOY YOZ XOZ
48434 Milmont Drive Fremont California 94538-7324 · Fremont, California, 94538-7324 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 17.00 mW |
| 2 | 15C | 2.41 GHz - 2.46 GHz | 106.00 mW |