2BEAJLZ060Toy Series

Shantou Barbosheng Technology Co., Ltd

Application Details

Equipment Class
FRF - Part 95 Family Radio Face Held Transmitter
Date of Grant
Jul 27, 2026
Application Purpose
Original Equipment
Equipment Note
Toy Series
Frequency Range
462.56250000 - 462.56250000
Company
Shantou Barbosheng Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Rev11/20/07 ShantouBarboshengTechnologyCo.,Ltd FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationof FCCID:2BEAJLZ060PursuanttoSections0.457and0.459oftheCommission’sRules,we herebyrequestconfidentialtreatmentofinformationaccompanyingthisapplicationasoutlined below: ExhibitTypeFileName (BlockDiagram,Schematics,Operational Description,BOM,Tuneupprocedure) (BlockDiagram.pdf,Schematics.pdf,Operational Description.pdf,BOM.pdf,Tuneupprocedure.pdf) Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateoftheGrant forthisapplication. PursuanttoDA04-1705June15,2004oftheCommission’spublicnotice,wealsorequestthat theinformationattachedtothisapplicationbetemporarilyconfidentialfor180daysasoutlined below: ExhibitTypeFileName UserManual ExternalPhotos InternalPhotos TestSetupPhotos UserManual.pdf ExternalPhotos.pdf InternalPhotos.pdf TestSetupPhotos.pdf Sincerely, Signature: printedname:ZHIYONGCAI Date:July22,2026

ID Label/Location Info

SIZE:1.5cm*1.5cm ToySeries FCCID:2BEAJLZ060

RF Exposure Info

Page: 1/10 Ref : ACR.37.13.26.PAR.B Cancel and replace the report ACR.37.13.26.PAR.A SHENZHEN LGT TEST SERVICE CO., LTD. ROOM 205, BUILDING 13,ZONE B, ZHENXIONGINDUSTRIAL PARK, NO.177, RENMIN WEST ROAD,JINSHA, KENGZI STREET, PINGSHAN DISTRICT,SHENZHEN, GUANGDONG, CHINA MVG COMOSAR DOSIMETRIC E-FIELD PROBE SERIAL NO.: 0326-EPGO-431 Calibrated at MVG 13 Rue du Zephyr 91140 Villejust - FRANCE Calibration date: 2026/01/22 Scope available on :https://a2la.org/ Summary: This document presents the method and results from an accredited COMOSAR Dosimetric E-Field Probe calibration performed at MVG, using the CALIPROBE test bench, for use with a MVG COMOSAR system only. The test results covered by accreditation are traceable to the International System of Units (SI). COMOSAR E-Field Probe Calibration Report Docusign Envelope ID: 441A23A1-88DE-4D98-BD64-561319DF94DB COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.37.13.26.PAR.B Page: 2/10 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vN This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Name Function Date Signature Prepared by : Pedro Ruiz Technical Manager 2/6/2026 Checked & approved by: Pedro Ruiz Technical Manager 2/6/2026 Authorized by: Christophe Barrot Quality Manager Customer Name Distribution : SHENZHEN LGT TEST SERVICE CO., LTD Issue Name Date Modifications A Pedro Ruiz 2/6/2026 Initial release B Pedro Ruiz 04/10/2026 Update customer address Docusign Envelope ID: 441A23A1-88DE-4D98-BD64-561319DF94DB 2026 April 13 COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.37.13.26.PAR.B Page: 3/10 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vN This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. TABLE OF CONTENTS 1 Device Under Test ..................................................................................................... 4 2 Product Description ................................................................................................... 4 2.1 General Information _______________________________________________________ 4 3 Measurement Method ................................................................................................ 4 3.1 Sensitivity _______________________________________________________________ 4 3.2 Linearity ________________________________________________________________ 4 3.3 Isotropy _________________________________________________________________ 5 3.4 Boundary Effect __________________________________________________________ 5 3.5 Probe Modulation Response _________________________________________________ 5 4 Measurement Uncertainty .......................................................................................... 6 5 Calibration Results ..................................................................................................... 6 5.1 Calibration in air __________________________________________________________ 6 5.2 Calibration in liquid _______________________________________________________ 7 6 Verification Results ................................................................................................... 8 7 List of Equipment ...................................................................................................... 9 Docusign Envelope ID: 441A23A1-88DE-4D98-BD64-561319DF94DB COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.37.13.26.PAR.B Page: 4/10 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vN This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 1 DEVICE UNDER TEST Device Under Test Device Type COMOSAR DOSIMETRIC E FIELD PROBE Manufacturer MVG Model SSE2 Serial Number 0326-EPGO-431 Product Condition (new / used) New Frequency Range of Probe 0.15 GHz-7.5GHz Resistance of Three Dipoles at Connector Dipole 1: R1=0.234 M Dipole 2: R2=0.234 M Dipole 3: R3=0.214 M 2 PRODUCT DESCRIPTION 2.1 GENERAL INFORMATION MVG’s COMOSAR E field Probes are built in accordance to the IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards. Figure 1 – MVG COMOSAR Dosimetric E field Probe Probe Length 330 mm Length of Individual Dipoles 2 mm Maximum external diameter 8 mm Probe Tip External Diameter 2.5 mm Distance between dipoles / probe extremity 1 mm 3 MEASUREMENT METHOD The IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards provide recommended practices for the probe calibrations, including the performance characteristics of interest and methods by which to assess their effect. All calibrations / measurements performed meet the fore-mentioned standards. 3.1 SENSITIVITY The sensitivity factors of the three dipoles were determined using a two step calibration method (air and tissue simulating liquid) using waveguides as outlined in the standards for frequency range 600- 7500MHz and using the calorimeter cell method (transfer method) as outlined in the standards for frequency 150-450 MHz. 3.2 LINEARITY The evaluation of the linearity was done in free space using the waveguide, performing a power sweep to cover the SAR range 0.01W/kg to 100W/kg. Docusign Envelope ID: 441A23A1-88DE-4D98-BD64-561319DF94DB COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.37.13.26.PAR.B Page: 5/10 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vN This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is…

Text truncated - open the document above for the full version.

RF Exposure Info

The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 27 SAR TEST REPORT Product Name: Toy Series Model Number: LZ060, LZ060A, LZ060B FCC ID: 2BEAJLZ060 Issued For : Shantou Barbosheng Technology Co., Ltd 601,6th Floor, No.10 Donghuguan Xing Road, Fengxiang Street, Chenghai District, Shantou, Guangdong, China 515800 Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT26D008HA01 Sample Received Date: May 22, 2026 Date of Test May 22, 2026 – June 01, 2026 Date of Issue June 01, 2026 Max. SAR (1g) Body: 0.253 W/kg Reprot No.: LGT26D008HA01 Page 2 of 27 Table of Contents 1. General Information 5 1.1 EUT Description 5 1.2 Test Environment 6 1.3 Test Factory 6 2. Test Standards and Limits 7 3. SAR Measurement System 8 3.1 Definition of Specific Absorption Rate (SAR) 8 3.2 SAR System 8 4. Tissue Simulating Liquids 11 4.1 Simulating Liquids Parameter Check 11 5. SAR System Validation 13 5.1 Validation System 13 5.2 Validation Result 13 6. SAR Evaluation Procedures 14 7. EUT Antenna Location Sketch 15 8. EUT Test Position 16 8.1 Body-worn Position Conditions 16 9. Uncertainty 17 9.1 Measurement Uncertainty 17 9.2 System validation Uncertainty 18 10. Conducted Power Measurement 19 10.1 Test Result 19 10.2 Tune Up Power 19 11. EUT and Test Setup Photo 20 11.1 EUT Photos 20 11.2 Setup Photos 20 12. SAR Result Summary 21 12.1 Body-worn SAR 21 13. Equipment List 22 Appendix A. System Validation Plots 23 Appendix B. SAR Test Plots 25 Appendix C. Probe Calibration and Dipole Calibration Report 27 Reprot No.: LGT26D008HA01 Page 3 of 27 Revision History Rev. Issue Date Contents 00 June 01, 2026 Initial Issue Reprot No.: LGT26D008HA01 Page 4 of 27 TEST REPORT CERTIFICATION Applicant Shantou Barbosheng Technology Co., Ltd Address 601,6th Floor, No.10 Donghuguan Xing Road, Fengxiang Street, Chenghai District, Shantou, Guangdong, China 515800 Manufacture Shantou Barbosheng Technology Co., Ltd Address 601,6th Floor, No.10 Donghuguan Xing Road, Fengxiang Street, Chenghai District, Shantou, Guangdong, China 515800 Product Name Toy Series Trademark N/A Model Number LZ060 Sample number LGT2604011 APPLICABLE STANDARDS STANDARD TEST RESULTS ANSI/IEEE Std. C95.1-2019 FCC 47 CFR Part 2 (2.1093) IEEE 1528: 2013 PASS Prepared by: Approved by: Deng Deng Engineer Vita Li Manager Reprot No.: LGT26D008HA01 Page 5 of 27 1. General Information Environmental evaluation measurements of specific absorption rate (SAR) distributions in emulated human head and body tissues exposed to radio frequency (RF) radiation from wireless portable devices for compliance with the rules and regulations of the U.S. Federal Communications Commission (FCC). 1.1 EUT Description Product Name Toy Series Test Model Number LZ060 Series Number LZ060A, LZ060B Model Difference Their electrical circuit design, layout, components used and internal wiring areidentical, Only the outer decoration is different. Device Category Portable Product stage Production unit RF Exposure Environment General Population / Uncontrolled Hardware Version N/A Software Version N/A Frequency Range 462.5625MHz Modulation Type: FM Max. Reported SAR(1g): Test distance: Face up:10mm Back Touch:0mm Mode Face up (with 10mm separation) Back Touch (with 0mm separation) Analog 0.253 0.044 Limit 1.6 W/kg Battery Rated Voltage: DC 3.7V Operating Mode: Maximum continuous output Antenna Specification Dipole Antenna Reprot No.: LGT26D008HA01 Page 6 of 27 1.2 Test Environment Ambient conditions in the SAR laboratory: Items Required Temperature (°C) 18-25 Humidity (%RH) 30-70 1.3 Test Factory Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate FCC Registration No.: 746540 CAB ID: CN0136 Reprot No.: LGT26D008HA01 Page 7 of 27 2. Test Standards and Limits No. Identity Document Title 1 47 CFR Part 2 Frequency Allocations and Radio Treaty Matters; General Rules and Regulations 2 ANSI/IEEE Std. C95.1-2019 IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz 3 IEEE Std. 1528-2013 Recommended Practice for Determining the Peak Spatial- Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques 4 FCC KDB 447498 D01 v06 Mobile and Portable Device RF Exposure Procedures and Equipment Authorization Policies 5 FCC KDB 865664 D01 v01r04 SAR Measurement 100 MHz to 6 GHz 6 FCC KDB 865664 D02 v01r02 RF Exposure Reporting 7 FCC KDB 648474 D04 v01r03 SAR Evaluation Considerations for Wireless Handsets (A). Limits for Occupational/Controlled Exposure (W/kg) Whole-Body Partial-Body Hands, Wrists, Feet and Ankles 0.4 8.0 20.0 (B). Limits for General Population/Uncontrolled Exposure (W/kg) Whole-Body Partial-Body Hands, Wrists, Feet and Ankles 0.08 1.6 4.0 NOTE: Whole-Body SAR is averaged over the entire body, partial-body SAR is averaged over any 1 gram of tissue defined as a tissue volume in the shape of a cube. SAR for hands, wrists, feet and ankles is averaged over any 10 grams of tissue defined as a tissue volume in the shape of a cube. Population/Uncontrolled Environments: Are defined as locations where there is the exposure of individuals who have no knowledge or control of their exposure. Occu…

Text truncated - open the document above for the full version.

Test Report

Report No. : EED32S801980Page 1 of 30 TEST REPORT Product:Toy Series Trade mark:N/A Model/Type reference:LZ060, LZ060A, LZ060B Serial Number:N/A Report Number:EED32S801980 FCC ID:2BEAJLZ060 Date of Issue:Jul. 23, 2026 Test Standards: 47 CFR Part 95, Subpart B Test result:PASS Prepared for: Shantou Barbosheng Technology Co., Ltd 601, 6th Floor, No.10 Donghuguan Xing Road, Fengxiang Street, Chenghai District, Shantou, Guangdong, China, 515800 Prepared by: Centre Testing International Group Co., Ltd. Building C, Hongwei Industrial Park Block 70, Bao'an District, Shenzhen, China TEL: +86-755-3368 3668 FAX: +86-755-3368 3385 Compiled by:Reviewed by: Frazer LiKeven Tan Approved by: Date:Jul. 23, 2026 Aaron Ma Check No.:7434230126 Report No. : EED32S801980Page 2 of 30 1 Content 1 Content...............................................................................................................................................................2 2 Test Summary...................................................................................................................................................3 4 General Information..........................................................................................................................................4 4.1Details of E.U.T............................................................................................................................................4 4.2Description of Support Units........................................................................................................................ 4 4.3Description of Support Units........................................................................................................................ 5 4.4Measurement Uncertainty............................................................................................................................5 4.5Test Location............................................................................................................................................... 6 4.6Deviation from Standards............................................................................................................................ 6 4.7Abnormalities from Standard Conditions..................................................................................................... 6 5 Equipment List..................................................................................................................................................7 6 Radio Spectrum Technical Requirement......................................................................................................10 6.1Antenna Requirement................................................................................................................................10 6.1.1 Test Requirement:..............................................................................................................................10 6.1.2 Conclusion..........................................................................................................................................10 7 Radio Spectrum Matter Test Results............................................................................................................11 7.1Frequency Stability.................................................................................................................................... 11 7.1.1 Measurement Data.............................................................................................................................12 7.2Effective Radiated Power (ERP)................................................................................................................13 7.2.1 Measurement Data.............................................................................................................................13 7.3.1 Measurement Procedure and Data...................................................................................................16 7.4Modulation Limits....................................................................................................................................... 18 7.4.1 Measurement Data.............................................................................................................................19 7.5Radiated Emissions...................................................................................................................................21 8 PHOTOGRAPHS..............................................................................................................................................29 Report No. : EED32S801980Page 3 of 30 2 Test Summary Radio Spectrum Technical Requirement ItemStandardMethodRequirementResult Antenna Requirement 47 CFR Part 95, Subpart B N/A 47 CFR Part 95, Subpart B 95.587(b) Pass Radio Spectrum Matter Part ItemStandardMethodRequirementResult Frequency Stability 47 CFR Part 95, Subpart B ANSI C63.26- 2015 47 CFR FCC Part95.565 & FCC Part2.1055; Pass Effective Radiated Power (ERP) 47 CFR Part 95, Subpart B ANSI C63.26- 2015 47 CFR FCC Part95.567 & FCC Part2.1046; Pass Occupied Bandwidth 47 CFR Part 95, Subpart B ANSI C63.26- 2015 47 CFR FCC Part 95.573 & FCC Part2.1049; Pass Modulation Limits47 CFR Part 95, Subpart B ANSI C63.26- 2015 47 CFR FCC Part 95.575 & FCC Part2.1047; Pass Radiated Emissions47 CFR Part 95, Subpart B ANSI C63.26- 2015 47 CFR FCC Part 95.579 & FCC Part2.1053; Pass Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. Model No.: LZ060, LZ060A, LZ060B Their electrical circuit design, layout, components used and internal wiring are identical, Only the outer decoration is different. Report No. : EED32S801980Page 4 of 30 4 General Information 4.1Details of E.U.T. Power supply: Battery:DC 3.7V Cable Loss (for RF conducted test): 1dB Operation Frequency: 462.5625M…

Text truncated - open the document above for the full version.

Test Report

SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. Professional antenna serviceprovider Item model Antenna model Testers Yue e wei Auditors Xing xi Xia Date Antenna 2026-3-27 test report SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. TEL:0755-23035723 Mail:[email protected] URL:www.fmant.cn Test equipment and test environment SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. TEL:0755-23035723 Mail:[email protected] URL:www.fmant.cn RelativeHumidity 15 ... 75 % Temperature +10 °C ~ +30 °C Voltage of the EUT N/A Test Environment Conditions: Test equipment Probe microwave anechoic chamber Frequency Range :0.4GHz- 6GHz SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. TEL:0755-23035723 Mail:[email protected] URL:www.fmant.cn Main test indicators Passive indicators Gain effectiveness 3D pattern Active indicator TRP total radiated power TIS total receiving sensitivity Test equipment Agilent E5071C Vector network analyzer Frequency Range :300 kHz - 8.5GHz R&S CMW500 Broadband wireless communication tester GSM/3G/4G WIFI/ Bluetooth NB-IoT SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. TEL:0755-23035723 Mail:[email protected] URL:www.fmant.cn Antenna gain and efficiency SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. TEL:0755-23035723 Mail:[email protected] URL:www.fmant.cn Freq '4: (MHz) Efficiency (%) Gian(dBi) 462 MHz 4.47 -10.18 插入图片1 插入图片2 插入图片3 插入图片4 Antenna Radiation Pattern SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. TEL:0755-23035723 Mail:[email protected] URL:www.fmant.cn 插入图片1 插入图片2 插入图片3 插入图片4 Antenna Radiation Pattern SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. TEL:0755-23035723 Mail:[email protected] URL:www.fmant.cn 插入图片1 插入图片2 插入图片3 插入图片4 Antenna Radiation Pattern SHENZHEN FEIMIN TECHNOLOGY CO.,LTD. TEL:0755-23035723 Mail:[email protected] URL:www.fmant.cn TEL:(86)755-23035723. FAX:0755-23036702 E-mail:[email protected] ADD: 303,building C,GUSHU Hengnan Road,Xixiang,Baoan district Shenzhen Thanks for your support!

Contact Information

Applicant

ZHIYONG CAI
[email protected]Fax: -

Technical Contact

Bridgeport Advisory LLCYong Liu
[email protected]

3330 W 38TH PL · CHICAGO, 60632 · United States

Test Firm

Centre Testing International Group Co., LtdVicky Zhou
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
195B462.5625 MHz - 462.5625 MHz300.00 µW6K08F3E0.2100000000Amp
Confidentiality
Long Term
Grant Notes
Output power listed is ERP. This device is authorized to operate in the FRF (Part 95B) radio service. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. The highest reported SAR values for head (face) and product specific (10g extremity) exposure conditions are 0.25 W/kg and < 0.10 W/kg, respectively, when operating at 50% duty cycle.