FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Xingchen International Import and Export Trading Co., Ltd/
  3. 2BEF3-WAPIKX5SFIT

2BEF3-WAPIKX5SFITSmart Watch

Shenzhen Xingchen International Import and Export Trading Co., Ltd
Smart Watch - FCC ID 2BEF3-WAPIKX5SFIT - Shenzhen Xingchen International Import and Export Trading Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 13, 2026
Application Purpose
Original Equipment
Equipment Note
Smart Watch
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Xingchen International Import and Export Trading Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

FCC ID: 2BEF3-WAPIKX5SFIT External Photos of the EUT FCC ID: 2BEF3-WAPIKX5SFIT FCC ID: 2BEF3-WAPIKX5SFIT

Internal Photos

FCC ID: 2BEF3-WAPIKX5SFIT Internal Photos of the EUT Antenna FCC ID: 2BEF3-WAPIKX5SFIT FCC ID: 2BEF3-WAPIKX5SFIT

RF Exposure Info

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure evaluation Report Reference No. ..................... : FCC ID............................................. : CTA26062503302 2BEF3-WAPIKX5SFIT Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jul. 01, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ............................ : Shenzhen Xingchen International Import and Export Trading Co., Ltd Address ............................................ : 368, 3rd Floor, Liangji Building, Longhua Street, Longhua District, Shenzhen City, Guangdong Province, China Standard ........................................... : 47CFR §1.1310 47CFR §2.1093 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Smart Watch Trade Mark ....................................... : WAPIK Manufacturer .................................... : Shenzhen Xingchen International Import and Export Trading Co., Ltd Model/Type reference ...................... : WAPIK X5S FIT Listed Models ................................... : WAPIK P5S FIT, WAPIK FIT, WAPIK FIT PRO, WAPIK FIT2, WAPIK FIT2PRO, WAPIK FIT3, WAPIK FIT3 PRO, WAPIK FIT5, WAPIK FIT5 PRO, WAPIK FIT6, WAPIK FIT6 PRO, WAPIK FIT8, WAPIK FIT8 PRO Rating ............................................... : Input: DC 5V Battery: 3.8V 300mAh 1.14Wh Result ............................................... : PASS Report No.: CTA26062503302 Page 2 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Smart Watch Model /Type : WAPIK X5S FIT Listed Models : WAPIK P5S FIT, WAPIK FIT, WAPIK FIT PRO, WAPIK FIT2, WAPIK FIT2PRO, WAPIK FIT3, WAPIK FIT3 PRO, WAPIK FIT5, WAPIK FIT5 PRO, WAPIK FIT6, WAPIK FIT6 PRO, WAPIK FIT8, WAPIK FIT8 PRO Model difference : The PCB board, circuit, structure and internal of these models are the same, only model number and colour are different for these models. So the tests were performed on model WAPIK X5S FIT and the test results for the main test model can cover the listed models. Applicant : Shenzhen Xingchen International Import and Export Trading Co., Ltd Address : 368, 3rd Floor, Liangji Building, Longhua Street, Longhua District, Shenzhen City, Guangdong Province, China Manufacturer : Shenzhen Xingchen International Import and Export Trading Co., Ltd Address : 368, 3rd Floor, Liangji Building, Longhua Street, Longhua District, Shenzhen City, Guangdong Province, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26062503302 Page 3 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ............................................................................................................ 4 2 SUMMARY .......................................................................................................................... 5 2.1 General Remarks ..................................................................................................... 5 2.2 Product Description ................................................................................................. 5 2.3 Special Accessories ................................................................................................. 5 2.4 Modifications ............................................................................................................ 5 3 TEST ENVIRONMENT ....................................................................................................... 6 3.1 Address of the test laboratory .................................................................................. 6 3.2 Test Facility .............................................................................................................. 6 3.3 Statement of the measurement uncertainty ............................................................. 6 4 Test limit .............................................................................................................................. 7 4.1 Requirement ............................................................................................................ 7 4.2 Conducted Power Results ....................................................................................... 7 4.3 Manufa…

Text truncated - open the document above for the full version.

Test Report

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ...................: FCC ID. ......................................... : CTA26062503301 2BEF3-WAPIKX5SFIT Compiled by ( position+printed name+signature) : File administrators Zoey Cao Supervised by ( position+printed name+signature) : Project Engineer Ace Chai Approved by ( position+printed name+signature) : RF Manager Eric Wang Date of issue ...................................: Jul. 01, 2026 Testing Laboratory Name .............: Shenzhen CTA Testing Technology Co., Ltd. Address ...........................................: Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name...........................: Shenzhen Xingchen International Import and Export Trading Co., Ltd Address ...........................................: 368, 3rd Floor, Liangji Building, Longhua Street, Longhua District, Shenzhen City, Guangdong Province, China Test specification ......................... : Standard ..........................................: FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Equipment description ................ : Smart Watch Trade Mark ......................................: WAPIK Manufacturer ...................................: Shenzhen Xingchen International Import and Export Trading Co., Ltd Model/Type reference .....................: WAPIK X5S FIT Listed Models ..................................: WAPIK P5S FIT, WAPIK FIT, WAPIK FIT PRO, WAPIK FIT2, WAPIK FIT2PRO, WAPIK FIT3, WAPIK FIT3 PRO, WAPIK FIT5, WAPIK FIT5 PRO, WAPIK FIT6, WAPIK FIT6 PRO, WAPIK FIT8, WAPIK FIT8 PRO Modulation ......................................: GFSK Frequency .......................................: From 2402MHz to 2480MHz Ratings ............................................: Input: DC 5V Battery: 3.8V 300mAh 1.14Wh Result ..............................................: PASS Report No.: CTA26062503301 Page 2 of 36 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Smart Watch Model /Type : WAPIK X5S FIT Listed Models : WAPIK P5S FIT, WAPIK FIT, WAPIK FIT PRO, WAPIK FIT2, WAPIK FIT2PRO, WAPIK FIT3, WAPIK FIT3 PRO, WAPIK FIT5, WAPIK FIT5 PRO, WAPIK FIT6, WAPIK FIT6 PRO, WAPIK FIT8, WAPIK FIT8 PRO Model difference : The PCB board, circuit, structure and internal of these models are the same, only model number and colour are different for these models. So the tests were performed on model WAPIK X5S FIT and the test results for the main test model can cover the listed models. Applicant : Shenzhen Xingchen International Import and Export Trading Co., Ltd Address : 368, 3rd Floor, Liangji Building, Longhua Street, Longhua District, Shenzhen City, Guangdong Province, China Manufacturer : Shenzhen Xingchen International Import and Export Trading Co., Ltd Address : 368, 3rd Floor, Liangji Building, Longhua Street, Longhua District, Shenzhen City, Guangdong Province, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26062503301 Page 3 of 36 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ...................................................................................................................................... 4 2 SUMMARY .................................................................................................................................................... 5 2.1 General Remarks .............................................................................................................................. 5 2.2 Product Description* .......................................................................................................................... 5 2.3 Equipment Under Test ....................................................................................................................... 5 2.4 Short description of the Equipment under Test (EUT) ...................................................................... 5 2.5 EUT configuration .............................................................................................................................. 6 2.6 EUT operation mode ......................................................................................................................... 6 2.7 Block Diagram of Test Setup ............................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) ......................................................................................................... 6 2.9 Modifications ............................................…

Text truncated - open the document above for the full version.

Test Report

1 FCC Appendix RF Test Data for BLE FCC ID : 2BEF3-WAPIKX5SFIT Company : Shenzhen Xingchen International Import and Export Trading Co., Ltd EUT : Smart Watch Model Number : WAPIK X5S FIT Report No. : CTA26062503301 Reviewed By : Eric Wang 2 Duty Cycle Mode Frequency (MHz) On Time (ms) Period (ms) Duty Cycle (%) Correction Factor (dB) 1/T (kHz) BLE 1M 2402 0.412 0.625 65.92 1.81 2.43 BLE 1M 2440 0.413 0.625 66.08 1.8 2.42 BLE 1M 2480 0.413 0.625 66.08 1.8 2.42 BLE 2M 2402 0.227 0.625 36.32 4.4 4.41 BLE 2M 2440 0.227 0.625 36.32 4.4 4.41 BLE 2M 2480 0.228 0.625 36.48 4.38 4.39 3 Test Graphs Duty Cycle NVNT BLE 1M 2402MHz Duty Cycle NVNT BLE 1M 2440MHz 4 Duty Cycle NVNT BLE 1M 2480MHz Duty Cycle NVNT BLE 2M 2402MHz 5 Duty Cycle NVNT BLE 2M 2440MHz Duty Cycle NVNT BLE 2M 2480MHz 6 Maximum Peak Conducted Output Power Mode Frequency (MHz) Conducted Power (dBm) Limit (dBm) Verdict BLE 1M 2402 -6.91 <=30 Pass BLE 1M 2440 -6.59 <=30 Pass BLE 1M 2480 -6.62 <=30 Pass BLE 2M 2402 -4.03 <=30 Pass BLE 2M 2440 -3.72 <=30 Pass BLE 2M 2480 -3.74 <=30 Pass 7 -6dB Bandwidth Mode Frequency (MHz) -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict BLE 1M 2402 0.6599 >=0.5 Pass BLE 1M 2440 0.6575 >=0.5 Pass BLE 1M 2480 0.6596 >=0.5 Pass BLE 2M 2402 1.148 >=0.5 Pass BLE 2M 2440 1.148 >=0.5 Pass BLE 2M 2480 1.14 >=0.5 Pass 8 Test Graphs -6dB Bandwidth NVNT BLE 1M 2402MHz -6dB Bandwidth NVNT BLE 1M 2440MHz 9 -6dB Bandwidth NVNT BLE 1M 2480MHz -6dB Bandwidth NVNT BLE 2M 2402MHz 10 -6dB Bandwidth NVNT BLE 2M 2440MHz -6dB Bandwidth NVNT BLE 2M 2480MHz 11 Maximum Power Spectral Density Level Mode Frequency (MHz) PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict BLE 1M 2402 -22.45 <=8 Pass BLE 1M 2440 -21.95 <=8 Pass BLE 1M 2480 -21.93 <=8 Pass BLE 2M 2402 -20.9 <=8 Pass BLE 2M 2440 -20.66 <=8 Pass BLE 2M 2480 -20.69 <=8 Pass 12 Test Graphs PSD NVNT BLE 1M 2402MHz PSD NVNT BLE 1M 2440MHz 13 PSD NVNT BLE 1M 2480MHz PSD NVNT BLE 2M 2402MHz 14 PSD NVNT BLE 2M 2440MHz PSD NVNT BLE 2M 2480MHz 15 Band Edge Mode Frequency (MHz) Max Value (dBc) Limit (dBc) Verdict BLE 1M 2402 -46.51 <=-20 Pass BLE 1M 2480 -49.21 <=-20 Pass BLE 2M 2402 -33.7 <=-20 Pass BLE 2M 2480 -45.55 <=-20 Pass 16 Test Graphs Band Edge NVNT BLE 1M 2402MHz Ref Band Edge NVNT BLE 1M 2402MHz Emission 17 Band Edge NVNT BLE 1M 2480MHz Ref Band Edge NVNT BLE 1M 2480MHz Emission 18 Band Edge NVNT BLE 2M 2402MHz Ref Band Edge NVNT BLE 2M 2402MHz Emission 19 Band Edge NVNT BLE 2M 2480MHz Ref Band Edge NVNT BLE 2M 2480MHz Emission 20 Conducted RF Spurious Emission Mode Frequency (MHz) Max Value (dBc) Limit (dBc) Verdict BLE 1M 2402 -31 <=-20 Pass BLE 1M 2440 -33.35 <=-20 Pass BLE 1M 2480 -31.02 <=-20 Pass BLE 2M 2402 -29.61 <=-20 Pass BLE 2M 2440 -30.51 <=-20 Pass BLE 2M 2480 -29.73 <=-20 Pass 21 Test Graphs Tx. Spurious NVNT BLE 1M 2402MHz Ref Tx. Spurious NVNT BLE 1M 2402MHz Emission 22 Tx. Spurious NVNT BLE 1M 2440MHz Ref Tx. Spurious NVNT BLE 1M 2440MHz Emission 23 Tx. Spurious NVNT BLE 1M 2480MHz Ref Tx. Spurious NVNT BLE 1M 2480MHz Emission 24 Tx. Spurious NVNT BLE 2M 2402MHz Ref Tx. Spurious NVNT BLE 2M 2402MHz Emission 25 Tx. Spurious NVNT BLE 2M 2440MHz Ref Tx. Spurious NVNT BLE 2M 2440MHz Emission 26 Tx. Spurious NVNT BLE 2M 2480MHz Ref Tx. Spurious NVNT BLE 2M 2480MHz Emission 27 Restrict Band Mode Frequency (MHz) Spur Freq (MHz) Power (dBm) Gain (dBi) Duty Factor (dB) E (dBuV/m) Detector Limit (dBuV/m) Verdict BLE 1M 2402 2310 -49.76 2 0 47.5 Peak <=74 Pass BLE 1M 2402 2310 -57.87 2 1.81 41.2 Average <=54 Pass BLE 1M 2402 2331.792 -47.15 2 0 50.11 Peak <=74 Pass BLE 1M 2402 2313.936 -56.84 2 1.81 42.23 Average <=54 Pass BLE 1M 2402 2390 -48.24 2 0 49.02 Peak <=74 Pass BLE 1M 2402 2390 -57.72 2 1.81 41.35 Average <=54 Pass BLE 1M 2480 2483.5 -47.8 2 0 49.46 Peak <=74 Pass BLE 1M 2480 2483.5 -57.48 2 1.8 41.58 Average <=54 Pass BLE 1M 2480 2487.592 -43.91 2 0 53.35 Peak <=74 Pass BLE 1M 2480 2487.448 -56.09 2 1.8 42.97 Average <=54 Pass BLE 1M 2480 2500 -48.87 2 0 48.39 Peak <=74 Pass BLE 1M 2480 2500 -57.01 2 1.8 42.05 Average <=54 Pass BLE 2M 2402 2310 -49.24 2 0 48.02 Peak <=74 Pass BLE 2M 2402 2310 -58.03 2 4.4 43.63 Average <=54 Pass BLE 2M 2402 2338.704 -47.06 2 0 50.2 Peak <=74 Pass BLE 2M 2402 2324.304 -57.07 2 4.4 44.59 Average <=54 Pass BLE 2M 2402 2390 -48.42 2 0 48.84 Peak <=74 Pass BLE 2M 2402 2390 -57.6 2 4.4 44.06 Average <=54 Pass BLE 2M 2480 2483.5 -48.78 2 0 48.48 Peak <=74 Pass BLE 2M 2480 2483.5 -56.36 2 4.38 45.28 Average <=54 Pass BLE 2M 2480 2487.496 -42.63 2 0 54.63 Peak <=74 Pass BLE 2M 2480 2487.232 -54.83 2 4.38 46.81 Average <=54 Pass BLE 2M 2480 2500 -47.63 2 0 49.63 Peak <=74 Pass BLE 2M 2480 2500 -57.42 2 4.38 44.22 Average <=54 Pass 28 Test Graphs Restrict Band NVNT BLE 1M 2402MHz Peak Restrict Band NVNT BLE 1M 2402MHz Average 29 Restrict Band NVNT BLE 1M 2480MHz Peak Restrict Band NVNT BLE 1M 2480MHz Average 30 Restrict Band NVNT BLE 2M 2402MHz Peak Restrict Band NVNT BLE 2M 2402MHz Average 31 Restrict Band NVNT BLE 2M 2480MHz Peak Restrict Band NVNT BLE 2M 2480MHz Average

Test Report

ShenzhenchangfengCommunicationTechnologyCo.,Ltd. AntennaInformation Manufacturer ShenzhenchangfengCommunication TechnologyCo.,Ltd. AddressRoom406,BuildingC,TongdaXuan,Northeast cornerofLongguanEastRoadandYucuiRoad,Yucui Community,LonghuaDistrict AntennaModelBluetoothlineantenna AntennaPartNumber3.30.S61.001 AntennaFrequencyRange2400-2500MHz AntennaType AntennaPeakGai Line antenna n-0.02dBiMAX AntennaDimension(LxHxW)20mm*0.6mm AntennaPhoto AntennaTopView[WithRuler] ShenzhenchangfengCommunicationTechnologyCo.,Ltd. AntennaBottomView[WithRuler] ShenzhenchangfengCommunicationTechnologyCo.,Ltd. AntennaPattern/GainMeasurementdata/Table: ShenzhenchangfengCommunicationTechnologyCo.,Ltd.

Test Setup Photos

FCC ID: 2BEF3-WAPIKX5SFIT Test Setup Photos of the EUT FCC ID: 2BEF3-WAPIKX5SFIT

Contact Information

Applicant

Chen Lin(CEO)
[email protected]Fax: 15659899828

Technical Contact

HOORAY INDUSTRY LLCCindy Wu
[email protected]

1408 Pinon Place, Fullerton, · United States

Test Firm

SHENZHEN CTA TESTING TECHNOLOGY CO., LTD.Eric Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz400.00 µW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.

Other Applications from Shenzhen Xingchen International Import and Export Trading Co., Ltd

Bluetooth earphones - FCC ID 2BEF3-RS7 - Shenzhen Xingchen International Import and Export Trading Co., Ltd
2BEF3-RS7

Bluetooth earphones

Jul 07, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Smart Watch - FCC ID 2BEF3-Y6 - Shenzhen Xingchen International Import and Export Trading Co., Ltd
2BEF3-Y6

Smart Watch

Mar 16, 2024

Equipment Class