Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
How to Use the Earwax Remover Visual earpick User Manual Please fully charge the wireless otoscope before using it for the first time How to Use the Earwax Remover Step 1 Download the AiSee plus APP Scan the following QR code, download and install the App. OR Diretly search the app "Aisee plus" on Google Play Store or your phone app store to download and install the APP How to Use the Earwax Remover Step 2 ①Turn on the button of ear otoscope (the 6 LED lights will slow flash) ②Open your phone ,, Settings"and find WIFI name: "Aisee-XXX", then you could connect the wifi ③After connect the WIFI,the 6 led lights of ear otoscope will light ④Open the "AiSee plus" APP and start to use the earwax removal Product Specification *Name: Visual earpick *Len Diameter: 3.5mm *Best Focal Length: 1.0-5.0cm *View Angle: 70 Degrees *Light Source: 6 LEDs *Image Sensor: CMOS *Pixel: 1080P *Battery Capacity: 280mAh *Power Consumption: 180mAh *Charging Time: 90 mins *Continuous Working Time: 40 mins *Standby Time: 120 days *Gravity Sensor: 4 Axis *Waterproof Level: IP67 (Just for lens) *Compatible Devices: Most Android 4.4, IOS 9.0 and high version smartphones, tablets etc More FAQs Q1: It doesn't provide clear pictures. A1: Our ear camera has a best focal length: 1.0-5.0cm for you to record video or pictures. Recording video is highly suggested, cause dynamic video is better to show real situation of you rears. 02: Can It work In a remote area when wifi is unavailable? A2: The otoscope is build-in Wifi that connected to your phone's wifi. So you can use it regardlessofwhether there is a network. 03: The Image was really good at first. After using for a period of time it's blurry. A3: Please use the cleaning cloth with alcohol or with thin cotton swab to clean the lens carefully after every time of use, since the ear wax is easy to stick on the lens or crevices around it Q4:Black screen, crashed screen or refused to be connected WIFI. A4: Download APP reinstall and try again. 05: The camera wont turn on with WIFI connected. A5: Make sure it is full-charged and connected to the correct WIFI "AiSee-***". Q6:1 can't use the ear otoscope wtth the Bluetooth! A6: Our earwax remover just connect the WIFI, NOT Bluetooth!!! Q7: The QR code Is not worMng.l can't download the app. A7: Please ask our online sale to get barcode or download our app "AiSee Pro" from the Google Play. Warm Tips Only the lens is waterproof. When you charge i&the power light is red. It's normal that the temperature of the ear endoscope will increase a little while the ear endoscope is working,please don't worry about it Children are not allowed to use this product without being accompanied by an adult. * The ear wax removal couldn't be used on the Windows system! This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The device has been evaluated to meet general RF exposure requirement.
“Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Applicant Company name: Shenzhen Heiyun Zhizao Technology Co., Ltd. Grantee Code: 2BEFA FCC ID: 2BEFA-HY08 FRN: 0034718031 Contact Name: Dawei zhang Address: 509-1509-1 Excellence Times Building, No. 27 Xinqiao 3rd Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen Telephone No: +8618025408156 Fax No: / Email: [email protected] Product Name: Visual earpick Model Number: HY08 i. [Shenzhen Heiyun Zhizao Technology Co., Ltd. ] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Shenzhen Heiyun Zhizao Technology Co., Ltd. ] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [Shenzhen Heiyun Zhizao Technology Co., Ltd. ] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment . Name: Dawei zhang Date: January 8, 2024 Title: General manager Signature of applicant: The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist
C5266091_X8_Ed.1 1/1 Letter of Authorization Shenzhen Heiyun Zhizao Technology Co., Ltd. Company name: Shenzhen Heiyun Zhizao Technology Co., Ltd. Grantee Code: 2BEFA FCC ID: 2BEFA-HY08 FRN: 0034718031 Contact Name: Dawei zhang Address: 509-1509-1 Excellence Times Building, No. 27 Xinqiao 3rd Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen Telephone No: +8618025408156 Fax No: / Email: [email protected] Product Name: Visual earpick Model Number: HY08 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Dawei zhang Date: January 8, 2024 Title: General manager Signature of applicant:
C5266091_X10_Ed.2 1/1 Shenzhen Heiyun Zhizao Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 08 January 2024 Subject: Request for Confidentiality FCC ID: 2BEFA-HY08 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, C5266091_X10_Ed.2 1/1 Name: Dawei zhang Date: January 8, 2024 Title: General manager Signature of applicant:
Page 1 of 3 Report No.: psi2312087-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 Appendix II external photos Page 2 of 3 Report No.: psi2312087-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 Page 3 of 3 Report No.: psi2312087-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 ------End------
Label: FCC ID: 2BEFA-HY08 Label location
Page 1 of 3 Report No.: psi2312053-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 Appendix III internal photos Page 2 of 3 Report No.: psi2312053-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 Antenna 1 WIFI Antenna Location Page 3 of 3 Report No.: psi2312053-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 ------End------
FCC ID: 2BEFA-HY08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 RF Exposure evaluation TEST STANDARDS Follow the maximum permissible exposure (MPE) limits specified in 447498 D04 Interim General Radio Frequency Exposure Guidelines v01. The gain of the antenna used in the product was extracted from the supplied antenna data sheet and the maximum total power input to the antenna was also measured. Calculate the distance from the product to the MPE limit by the formula. According to 447498 D04 Interim General RF Exposure Guidance v01 1-mW Test Exemption A single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption applies to all operating configurations and exposure conditions, for the frequency range 100 kHz to 100 GHz, regardless of fixed, mobile, or portable device exposure conditions. This is a standalone exemption, and it cannot be applied in conjunction with any other test exemption. 1-mW Test Exemption for Multiple Sources The 1-mW exemption intended for single transmitters may be also applied to simultaneous transmission conditions, within the same host device, according one of the following criteria: a) When maximum available power each individual transmitting antenna within the same time averaging period is ≤ 1 mW, and the nearest parts of the antenna structures of the simultaneously operating transmitters are separated by at least 2 cm. b) When the aggregate maximum available power of all transmitting antennas is ≤ 1 mW in the same time-averaging period. This exemption may not be combined with any other exemption. SAR-Based Exemption This exemption is applicable to the frequency range between 300 MHz and 6 GHz, with test separation distances between 0.5 cm and 40 cm, and for all RF sources in fixed, mobile, and portable device exposure conditions. Accordingly, a RF source is considered an RF exempt device if its available maximum time-averaged (matched conducted) power or its effective radiated power (ERP), whichever is greater, are below a specified threshold. This exemption threshold was derived based on general population 1-g SAR requirements. This method shall only be used at separation distances from 0.5 cm to 40 cm and at frequencies from 0.3 GHz to 6 GHz (inclusive). Pth is given by follow Formulas Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 “f” is in GHz, “d” is the separation distance (cm) (SAR-Based Exemption) Test Result of RF Exposure Evaluation As this equipment: Max. Antenna Gain: -6dBi. Max. Conducted Power: 3.17dBm Mode Output power (dBm) Max Output power (mW) Separation distance (cm) Limit (mW) Result 2.4G WiFi 3.17 2.075 0.5 2.73 PASS Conclusion: No SAR is required. Note: 1. This device is mobile device. 2. The source of the evaluation data results is based on the test report psi2312087-C01-R01. 3. The Maxinum power is less than the limit, complies with the exemption requirements. -----The End-----
Shenzhen Molian Technology Co., Ltd 规格承认书 SPECIFICATION FORAPPROVAL 编号:16112102 File No. 版本:1.0 Rev ision 客戶 CUSTOMER: ______________________________________ 客戶料号 CUSTOMER NO:______________________________________ 品名 2.4GHz PCB 板载 Antenna PART NAME: ______________________________________ 供方料号 SUPPLIER NO: _____________________________________ 送样日期 Date:送样数量Q’TY: PCS 客户确认 CUSTOMER APPROVED BY APPROVALCHIEFSUPERVISOR 供方确认 SUPPLIER SIGNATURE APPROVALCHECKDESIGN SH-RD-F04-A Address: 1007, Tongfang Center Building, Haoxiang Road, Xin'er Community, Xinqiao Street, Bao'an District, Shenzhen 承认书项目表 页数 (Number of Page ) 页码 (Page Code ) 内容 (Contents) NO. 1 2 承认书封面( Spec Cover ) 承认书项目表(Spec Item) 1 1 1 2 工程成品图( Drawing ) 1 1 1 1 3 4 5 6 3 4 5 6 7 8 9 电性测试报告( Test Reports ) S 参数测试( S Parameter ) 增益测试(Gain Test) 10 11 - - - - - - 12 --- 电性测试报告 Test Reports Electrical Properties Frequency Impedance V.S.W.R Return Loss Radiation Gain (Peak) Cable Loss Polarization Admitted Power Connector 2.4GHz 50 0hm Nominal 1.92 : 1 Max -10 dB Max Omni-directional -6 dBi 3.2 dB / m Max @ 2450 MHz Linear, Vertical 1 W Physical Properties Antenna Material Cable Type PCB Operating Temp. Storage Temp. -10 ~ +60 ̊C -10 ~ +70 ̊C Cable Color S参数测试 S ParameterTest AgilentE5071C 增益测试 Gain Test Antenna Radiation Pattern VS 90 -5 13545 Gain -15 -25 -35 -45 -35-25-15-5 1800 225315 270 2400 MHz 2450 MHz 2500 MHz Power (dBi) Max: 0 Min: -50 Scale: 5/div Specifications and dimensions
Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 FCC TEST REPORT FCC ID: 2BEFA-HY08 On Behalf of Shenzhen Heiyun Zhizao Technology Co., Ltd. Visual earpick Model No.: HY08 Prepared for : Shenzhen Heiyun Zhizao Technology Co., Ltd. Address : 509-1509-1 Excellence Times Building, No. 27 Xinqiao 3rd Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen Prepared By : Shenzhen PSI Testing Co., Ltd. Address : 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao’an District, Shenzhen, Guangdong, China 518104 Report Number : psi2312087-C01-R01 Date of Receipt : December 25, 2023 Date of Test : December 26, 2023-January 11, 2024 Date of Report : January 11, 2024 Version Number : V0 Page 2 of 71 Report No.: psi2312087-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 TABLE OF CONTENTS Description Page 1. Summary Of Standards And Results ----------------------------------------------------------------------------------- 6 1.1. Description of Standards and Results --------------------------------------------------------------------------- 6 2. General Information --------------------------------------------------------------------------------------------------------- 7 2.1. Description of Device (EUT) --------------------------------------------------------------------------------------- 7 2.2. Accessories of Device (EUT) -------------------------------------------------------------------------------------- 8 2.3. Tested Supporting System Details-------------------------------------------------------------------------------- 8 2.4. Block Diagram of Connection Between EUT and Simulators ---------------------------------------------- 8 2.5. Test Mode Description ----------------------------------------------------------------------------------------------- 9 2.6. Test Conditions ------------------------------------------------------------------------------------------------------ 10 2.7. Test Facility ----------------------------------------------------------------------------------------------------------- 10 2.8. Measurement Uncertainty ---------------------------------------------------------------------------------------- 10 2.9. Test Equipment List ------------------------------------------------------------------------------------------------ 11 3. Spurious Emission --------------------------------------------------------------------------------------------------------- 12 3.1. Test Limits ------------------------------------------------------------------------------------------------------------ 12 3.2. Block Diagram of Test setup ------------------------------------------------------------------------------------- 13 3.3. Test Procedure ------------------------------------------------------------------------------------------------------ 14 3.4. Test Results ---------------------------------------------------------------------------------------------------------- 15 4. Power Line Conducted Emission ------------------------------------------------------------------------------------- 23 4.1. Test Limits ------------------------------------------------------------------------------------------------------------ 23 4.2. Test Procedure ------------------------------------------------------------------------------------------------------ 23 4.3. Test Setup ------------------------------------------------------------------------------------------------------------ 23 4.4. Test Results ---------------------------------------------------------------------------------------------------------- 24 5. Out-of-band Emissions --------------------------------------------------------------------------------------------------- 27 5.1. Test Limits ------------------------------------------------------------------------------------------------------------ 27 5.2. Test Procedure ------------------------------------------------------------------------------------------------------ 27 5.3. Test Setup ------------------------------------------------------------------------------------------------------------ 27 5.4. Test Results ---------------------------------------------------------------------------------------------------------- 27 6. Conducted Maximum Output Power --------------------------------------------------------------------------------- 43 6.1. Test limits ------------------------------------------------------------------------------------------------------------- 43 6.2. Test Procedure ------------------------------------------------------------------------------------------------------ 43 6.3. Test Setup ------------------------------------------------------------------------------------------------------------ 43 6.4. Test Results ---------------------------------------------------------------------------------------------------------- 43 7. Peak Power Spectral Density ------------------------------------------------------------------------------------------- 49 7.1. Test limits ------------------------------------------------------------------------------------------------------------- 49 7.2. Test Procedure ------------------------------------------------------------------------------------------------------ 49 7.3. Test Setup ------------------------------------------------------------------------------------------------------------ 49 7.4. Test Results ---------------------------------------------------------------------------------------------------------- 49 8. Bandwidth -----------------------------------------------------------------------------------------…
Text truncated - open the document above for the full version.
Page 1 of 2 Report No.: psi2312087-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 Appendix I Test Setup Photo Spurious Radiation Emissions Test (<1G) Spurious Radiation Emissions Test (>1G) Page 2 of 2 Report No.: psi2312087-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2F, Building 5, Yudafu Industrial Park, No. 10, Xingye West Road, Shajing Street, Bao'an District, Shenzhen, Guangdong, China 518104 Conducted emission Test ------End------
Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 2.08 mW |