Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Smart Watch FCC Requirement Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions: (1)this device may not cause harmful interference,and (2)this device must accept any interference received, including interference that may cause undesired operation. Note:This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates,uses,and can radiate radio frequency energy,and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However,there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
ShenzhenLanshiTechnologyCo.,Ltd. 7thFloor,BuildingA,Building1,GanfengTechnologyBuilding,Bantian Street,LonggangDistrict,ShenzhenCity,China FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 Date :July30,2026 U.S.AgentDesignation {ShenzhenLanshiTechnologyCo.,Ltd.}acknowledgestheirconsentforthefollowingcontactlocatedinthe UnitedStatestoactastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCC ID:2BEIE-CUBE): NameandcompanyofU.S.agent:BridgeportAdvisoryLLC PhysicalU.S.addressofagent:3330W38THPL,CHICAGO,IL60632,UnitedStates FRNofU.S.agent:0037566148 EmailaddressofU.S.agent:[email protected] ContactNO.:(708)680-6688 BridgeportAdvisoryLLCacknowledgestheirobligationtoacceptserviceofprocessonbehalfof{Shenzhen LanshiTechnologyCo.,Ltd.}. {ShenzhenLanshiTechnologyCo.,Ltd.}withtheFRN[0034734715]acceptsitsobligationtomaintainanagent forserviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofany Commission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature ZhiLi Manager ShenzhenLanshiTechnologyCo.,Ltd. Signature MrYongLiu ManagingMember BridgeportAdvisoryLLC 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5
Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2BEIE-CUBE Cube, Cube Pro, Cube Ultra, Prime X, Luxor Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti-virus software Compliance The memory used does not allow the running the cybersecurity and/or anti-virus software Compliance The storage capacity does not allow the running the cybersecurity and/or anti-virus software Compliance The operating system used is not capable of running the cybersecurity and/or anti-virus software Compliance No inherent compliance Based on software bill of material Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: Shenzhen Huaxia Testing Technology Co., Ltd Contact Name: Yoyo Zhou Address: 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China Phone: +86-755-26648642 Email: [email protected] Signature: Date: 2026-07-21
ShenzhenLanshiTechnologyCo.,Ltd. ModelConfirmationLetter We,ShenzhenLanshiTechnologyCo.,Ltd.certifytheproduct: SmartWatch ModelNo.:Cube,CubePro,CubeUltra,PrimeX,Luxor FCCID:2BEIE-CUBE Theirelectricalcircuitdesign,layout,componentsusedandinternalwiringareidentical, Onlythecolorweredifferent. Signiture: GranteeContact:ZhiLi CompanyName:ShenzhenLanshiTechnologyCo.,Ltd. Date:July30,2026
ReportNo.:CQASZ20260701475E Photographs-EUTConstructionalDetails ReportNo.:CQASZ20260701475E ReportNo.:CQASZ20260701475E ReportNo.:CQASZ20260701475E
ReportNo.:CQASZ20260701475E Photographs-EUTConstructionalDetails Antenna ReportNo.:CQASZ20260701475E ReportNo.:CQASZ20260701475E
SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD 102A,102B,Building2,ShanghenglangNewIndustrialZone,ShanghenglangCommunity, DalangStreet,LonghuaDistrict,Shenzhen,Guangdong,People’sRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V06 ReportTemplateRevisionDate:2026-01-30 TESTREPORT Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlytothe sample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.: CQASZ20260701475E-03 Applicant:ShenzhenLanshiTechnologyCo.,Ltd. AddressofApplicant:7thFloor,BuildingA,Building1,GanfengTechnologyBuilding,BantianStreet, LonggangDistrict,ShenzhenCity,China EquipmentUnderTest(EUT): EUTName:SmartWatch ModelNo.:Cube,CubePro,CubeUltra,PrimeX,Luxor TestModelNo.:Cube BrandName:N/A FCCID: 2BEIE-CUBE Standards: 47CFRPart1.1307 47CFRPart1.1310 KDB447498D01GeneralRFExposureGuidancev06 DateofReceipt:2026-07-06 DateofTest: 2026-07-06to2026-07-20 DateofIssue: 2026-07-21 TestResult:PASS TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701475E-03 Page: 2 of 8 1.Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20260701475E-03Rev.01 Initialreport 2026-07-21 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701475E-03 Page: 3 of 8 2.Contents 1.VERSION....................................................................................................................................................................................2 2.CONTENTS................................................................................................................................................................................3 3.GENERALINFORMATION....................................................................................................................................................4 4.CLIENTINFORMATION........................................................................................................................................................4 5.GENERALDESCRIPTIONOFEUT......................................................................................................................................4 6.GENERALDESCRIPTIONOFBLE......................................................................................................................................4 7.GENERALDESCRIPTIONOFBT.........................................................................................................................................4 RFEXPOSUREEVALUATION..................................................................................................................................................6 RFEXPOSURECOMPLIANCEREQUIREMENT.............................................................................................................................6 StandardRequirement........................................................................................................................................................6 Limits......................................................................................................................................................................................6 EUTRFExposure................................................................................................................................................................7 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701475E-03 Page: 4 of 8 3.GeneralInformation 4.ClientInformation Applicant: ShenzhenLanshiTechnologyCo.,Ltd. AddressofApplicant: 7thFloor,BuildingA,Building1,GanfengTechnologyBuilding,Bantian Street,LonggangDistrict,ShenzhenCity,China Manufacturer: ShenzhenLanshiTechnologyCo.,Ltd. AddressofManufacturer: 7thFloor,BuildingA,Building1,GanfengTechnologyBuilding,Bantian Street,LonggangDistrict,ShenzhenCity,China Factory: ShenzhenLanshiTechnologyCo.,Ltd. AddressofFactory: 7thFloor,BuildingA,Building1,GanfengTechnologyBuilding,Bantian Street,LonggangDistrict,ShenzhenCity,China 5.GeneralDescriptionofEUT ProductName: SmartWatch ModelNo.: Cube,CubePro,CubeUltra,PrimeX,Luxor TestModelNo.: Cube TradeMark: N/A SoftwareVersion: AT281FDKV003447 HardwareVersion: AT281-v04 PowerSupply: Li-ionbatteryDC3.8V380mAh,ChargebyDC5Vforadapter SimultaneousTransmissionSimultaneousTXissupportedandevaluatedinthisreport. SimultaneousTXisnotsupported. 6.GeneralDescriptionofBLE OperationFrequency:2402MHz~2480MHz ModulationType:GFSK TransferRate:1Mbps/2Mbps NumberofChannel:40 ProductType:MobilePortableFixLocation AntennaType:WireAntenna AntennaGain: -9.46dBi 7.GeneralDescriptionofBT OperationFrequency:2402MHz~2480MHz ModulationType:GFSK,π/4DQPSK,8DPSK TransferRate:1Mbps/2Mbps/3Mbps NumberofChannel:79 ProductType:MobilePortableFixLocation AntennaType:WireAntenna SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701475E-03 Page: 5 of 8 AntennaGain: -9.46dBi SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701475E-03 Page: 6 of 8 RFExposureEvaluation RFExposureComplianceRequirement StandardRequirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06 4.3.1.StandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1- gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARExclusionThresholdcondition,listedbelow,issatisfied. Limits The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattestseparation distances≤50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[√f(GHz)]≤3.0for1-gSARand≤7.5for10-gextremitySAR,where f(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation17 Theresultisroundedtoonedecimalplaceforcomparison Thetestexclusionsareapplicableonlywhentheminimu…
Text truncated - open the document above for the full version.
深圳华讯视通科技有限公司 Shenzhen Huaxunshitong Technology Co.,Ltd. BT Antenna Specifications 2026-6-25 深圳华讯视通科技有限公司 Shenzhen Huaxunshitong Technology Co.,Ltd. 测试项目Test Item 设备 Equipment 1. S参数 (S-1.回波损耗 (Return Loss) 网络分析仪/Network Analyzer: Agilent E5071B parameter)2.电压驻波比(VSWR) HP 8753D 2. 有源测试1.发射功率 (TRP)1. 暗室/Darkroom:ETS 7x4x3 m (3D) Chamber (Active )2.接收灵敏度(TIS) ETS 5x3x3 m (3D) Chamber 2.综合测试仪/Integrated Test Instrument: Agilent 8960 E5515B ×2 StarPoint SP6011 3.无源测试1.天线增益 (Gain)1.暗室:ETS 7x4x3 m (3D) Chamber (Passive)2.天线效率 (Efficiency) ETS 5x3x3 m (3D) Chamber 2.网络分析仪:Agilent E5071B HP 8753D 测试项目与设备 Testing items and equipment 深圳华讯视通科技有限公司 Shenzhen Huaxunshitong Technology Co.,Ltd. 整机图片 Overall machine picture 增益与效率 Gain and Efficiency 增益与效率 Gain and Efficiency 增益与效率 Gain and Efficiency 增益与效率 Gain and Efficiency 天线 Antenna Dimension 深圳华讯视通科技有限公司 Shenzhen Huaxunshitong Technology Co.,Ltd. m 制造商地址:深圳市宝安区航城街道黄田大门路1号鸿丰华互联网创意园3楼 3005室 mManufacturer's Address: Room 3005, 3rd Floor, Hongfenghua Internet Creative Park, No. 1, Huangtian Gate Road, Hangcheng Street, Bao'an District, Shenzhen City, China Thanks!
CQASZ20260701475E-01 AppendixA:DTSBandwidth TestResult TestModeFreq(MHz) DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1M 24020.672401.692402.360.5PASS 24400.672439.682440.360.5PASS 24800.662479.692480.350.5PASS BLE_2M 24021.142401.442402.590.5PASS 24401.142439.442440.580.5PASS 24801.142479.452480.580.5PASS TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 BLE_2M_Ant1_2480 AppendixB:OccupiedChannelBandwidth TestResult TestModeAntennaFreq(MHz) OCB[MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24021.0712401.48452402.5554------ 24401.0632439.48852440.5514------ 24801.0512479.49652480.5475------ BLE_2MAnt1 24021.9662401.04102403.0070------ 24401.9542439.05292441.0070------ 24801.9622479.04502481.0070------ TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 BLE_2M_Ant1_2480 AppendixC:Maximumconductedoutputpower TestResultPeak TestModeFreq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict BLE_1M 24020.00≤30PASS 24402.06≤30PASS 24801.37≤30PASS BLE_2M 2402-0.15≤30PASS 24401.58≤30PASS 24801.11≤30PASS TestGraphsPeak BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 BLE_2M_Ant1_2480 AppendixD:Maximumpowerspectraldensity TestResult TestModeFreq(MHz)Result[dBm/3kHz]Limit[dBm/3kHz]Verdict BLE_1M 2402-16.76≤8.00PASS 2440-14.54≤8.00PASS 2480-15.21≤8.00PASS BLE_2M 2402-19.60≤8.00PASS 2440-17.51≤8.00PASS 2480-18.10≤8.00PASS TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 BLE_2M_Ant1_2480 AppendixF:Bandedgemeasurements TestResult TestModeChNameFreq(MHz)RefLevel[dBm]Result[dBm]Limit[dBm]Verdict BLE_1M Low2402-0.70-43.82≤-20.7PASS High2480-0.11-42.35≤-20.11PASS BLE_2M Low2402-1.32-41.23≤-21.32PASS High2480-0.10-42.89≤-20.1PASS TestGraphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 BLE_2M_Ant1_Low_2402 BLE_2M_Ant1_High_2480 AppendixG:ConductedSpuriousEmission TestResult TestModeFreq(MHz) FreqRange [MHz] RefLevel [dBm] Result[dBm]Limit[dBm]Verdict BLE_1M 2402 Reference-1.37-1.37---PASS 30~1000-1.37-51.83≤-21.37PASS 1000~26500-1.37-46.31≤-21.37PASS 2440 Reference1.431.43---PASS 30~10001.43-50.88≤-18.57PASS 1000~265001.43-48.51≤-18.57PASS 2480 Reference0.620.62---PASS 30~10000.62-51.5≤-19.38PASS 1000~265000.62-46.82≤-19.38PASS BLE_2M 2402 Reference-1.57-1.57---PASS 30~1000-1.57-52.29≤-21.57PASS 1000~26500-1.57-47.52≤-21.57PASS 2440 Reference0.630.63---PASS 30~10000.63-51.14≤-19.37PASS 1000~265000.63-48.27≤-19.37PASS 2480 Reference-0.05-0.05---PASS 30~1000-0.05-51.92≤-20.05PASS 1000~26500-0.05-48.05≤-20.05PASS TestGraphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference BLE_1M_Ant1_2480_30~1000 BLE_1M_Ant1_2480_1000~26500 BLE_2M_Ant1_2402_0~Reference BLE_2M_Ant1_2402_30~1000 BLE_2M_Ant1_2402_1000~26500 BLE_2M_Ant1_2440_0~Reference BLE_2M_Ant1_2440_30~1000 BLE_2M_Ant1_2440_1000~26500 BLE_2M_Ant1_2480_0~Reference BLE_2M_Ant1_2480_30~1000 BLE_2M_Ant1_2480_1000~26500 AppendixH:DutyCycle TestResult TestModeFreq(MHz) ONTime [ms] Period [ms] XDC [%] xFactor LimitVerdict BLE_1M 24022.142.500.856085.600.68------ 24402.142.500.856085.600.68------ 24802.142.500.856085.600.68------ BLE_2M 24021.081.250.864086.400.63------ 24401.081.250.864086.400.63------ 24801.081.250.864086.400.63------ TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 BLE_2M_Ant1_2480
SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD 102A,102B,Building2,ShanghenglangNewIndustrialZone,ShanghenglangCommunity, DalangStreet,LonghuaDistrict,Shenzhen,Guangdong,People’sRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V06 ReportTemplateRevisionDate:2026-01-30 TestReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonly tothesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20260701475E-01 Applicant:ShenzhenLanshiTechnologyCo.,Ltd. AddressofApplicant:7thFloor,BuildingA,Building1,GanfengTechnologyBuilding,BantianStreet, LonggangDistrict,ShenzhenCity,China EquipmentUnderTest(EUT): Product:SmartWatch ModelNo.:Cube,CubePro,CubeUltra,PrimeX,Luxor TestModelNo.:Cube BrandName:N/A FCCID:2BEIE-CUBE Standards:47CFRPart15,SubpartC KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10:2020 DateofReceipt:2026-07-06 DateofTest: 2026-07-06to2026-07-20 DateofIssue:2026-07-21 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701475E-01 Page: 2 of 31 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20260701475E-01Rev.01Initialreport2026-07-21 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701475E-01 Page: 3 of 31 2TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement 47CFRPart15,SubpartCSection 15.203/15.247(c) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS ACPowerLine Conducted Emission 47CFRPart15,SubpartCSection 15.207 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS ConductedPeakOutput Power 47CFRPart15,SubpartCSection 15.247(b)(3) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS 6dBOccupied Bandwidth 47CFRPart15,SubpartCSection 15.247(a)(2) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS PowerSpectralDensity 47CFRPart15,SubpartCSection 15.247(e) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS Band-edgeforRF ConductedEmissions 47CFRPart15,SubpartCSection 15.247(d) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS RFConductedSpurious Emissions 47CFRPart15,SubpartCSection 15.247(d) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS RadiatedSpurious Emissions 47CFRPart15,SubpartCSection 15.205/15.209 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS Restrictedbandsaround fundamentalfrequency (RadiatedEmission) 47CFRPart15,SubpartCSection 15.205/15.209 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701475E-01 Page: 4 of 31 3Contents Page 1VERSION..........................................................................................................................................................................2 2TESTSUMMARY............................................................................................................................................................3 3CONTENTS......................................................................................................................................................................4 4GENERALINFORMATION...........................................................................................................................................5 4.1CLIENTINFORMATION.................................................................................................................................................5 4.2GENERALDESCRIPTIONOFEUT.................................................................................................................................5 4.3ADDITIONALINSTRUCTIONS........................................................................................................................................7 4.4TESTENVIRONMENT...................................................................................................................................................8 4.5DESCRIPTIONOFSUPPORTUNITS...............................................................................................................................8 4.6TESTCONFIGURATION................................................................................................................................................8 4.7STATEMENTOFTHEMEASUREMENTUNCERTAINTY....................................................................................................9 4.8TESTLOCATION........................................................................................................................................................10 4.9TESTFACILITY..........................................................................................................................................................10 4.10DEVIATIONFROMSTANDARDS................................................................................................................................10 4.11OTHERINFORMATIONREQUESTEDBYTHECUSTOMER..........................................................................................10 4.12EQUIPMENTLIST.....................................................................................................................................................11 5TESTRESULTSANDMEASUREMENTDATA.....................................................................................................12 5.1ANTENNAREQUIREMENT..........................................................................................................................................12 5.2CONDUCTEDEMISSIONS............................................................................................................................................13 5.3CONDUCTEDPEAKOUTPUTPOWER........…
Text truncated - open the document above for the full version.
ReportNo.:CQASZ20260701475E 1Photographs-EUTTestSetup 1.1RadiatedSpuriousEmission 9kHz~30MHz: 30MHz~1GHz: ReportNo.:CQASZ20260701475E Above1GHz: 1.2 ConductedEmission ReportNo.:CQASZ20260701475E 1.3 RFConductedmeasurement
3330 W 38TH PL, CHICAGO, · Illinois, 60632 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.60 mW |