2BEPD-FWFitness Walker

Zhejiang Fanpao intelligent technology Co., LTD
Fitness Walker - FCC ID 2BEPD-FW - Zhejiang Fanpao intelligent technology Co., LTD
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 17, 2024
Application Purpose
Original Equipment
Date of Application
Mar 17, 2024
Equipment Note
Fitness Walker
Frequency Range
2402.00000000 - 2480.00000000
Company
Zhejiang Fanpao intelligent technology Co., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual ModelCS-WP8 Please read the instruction manual carefully before using this product. EU V1.2.3 HOW TO CONTACT US ON AMAZON? Step 1: Log in to your Amazon account. Step 2: Go to Your Orders. Select Problem with order in the list. Step 3: Click the "Ask a Question" button. Choose your topic from list displayed. Step 4: Select Contact seller. *If you purchased CITYSPORTS products by other platforms or channels, please also find the corresponding seller contact support. Thanks for your support and patience! LANGUAGE LIST EN.........................1 DE ........................21 ES ........................41 FR ........................61 IT .........................81 NL .......................101 PL .......................121 Service Commitment If the treadmill is faulty or in doubt in use, you can contact us through the email address in our store “About Seller”page and then send us the detailed product problem(if ok, some photos/videos will be useful), we will                    Download the App for treadmill Video of the running belt adjustment Video of the motor replacement Video of the upper control replacement Video of the lower control replacement - EN-1 - Catalogue    !" #$ ! % "!& ' *   +.     &!0 2   0 34   5 "6  4   !3 78   % 3!& &9   0!#5 - EN-2 - Thank you for purchasing our product, which will help to improve your health. .      ;   should be splashed on the treadmill and no foreign objects should be    #      < = <     .          socket must have a dedicated circuit to avoid sharing with other electrical >   2'  ?        3      ;  damage to the motor or controller, and speed up the wear and aging of the bearings, running belt and running board,so please do regular     "9        ?             ;             7          *    <  & ?       04         ;<          To ensure your safety and avoid accidents, please read the                !9G!! 5@ ;           >              B555C#55588 #F                   WARNING: To reduce the risk of accidents or injury to others, please         ?     H J      =       ?  =     K  F      =     .       6    <    @     &4 JJ;    ;  ;     ; <             =          ?;?   L    <M    !!!6   K    #=   ;     !!!     ?  * J  =    O O    !  K  J  - EN-4 -      ! =        !!!!     ?  K  J  "    ! Q    ?     !!!          ;     ?*      ?      !!!R        ? K  If it does not start or feels abnormal, stop using it, unplug it immediately       ?   !!!R         ? K  4     ;     !!!6;   K     3$     ;   ;        !!!6    ?;   ?*   #   ! .    4        ;         ?   ? . >    >   earthing conductor and an earthing plug, which must be plugged into a suitable socket that has been properly installed and earthed in full  …

Text truncated - open the document above for the full version.

Attestation Statements

C5266091_X24_Ed.2 1/1 Zhejiang Fanpao intelligent technology Co., LTD TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Zhejiang Fanpao intelligent technology Co., LTD Grantee code: 2BEPD FCC ID: 2BEPD-FW FRN: 0034789545 Contact Name: Jinfa Miao Address: Room 401, Building 2, Cangling No.Road 1-1, Hu Town, Jinyun County, Lishui City, Zhejiang Province,China Telephone No: / 13580712713 Fax No:/ Email: [email protected] i. [Zhejiang Fanpao intelligent technology Co., LTD] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Zhejiang Fanpao intelligent technology Co., LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [ is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [Zhejiang Fanpao intelligent technology Co., LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [ is not] identified on the Covered List as an entity producing “covered”equipment . Date: 2024/03/07 Applicant’s Name: Jinfa Miao Title: Manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

Modeldifferencedeclarationletter DifferencesDescription FCCID:2BEPD-FW WeZhejiangFanpaointelligenttechnologyCo.,LTDstate: Product: FitnessWalker ModelName : CS-WP8,CS-WP2,CS-WP6,CS-WP10, CS-WP11,CS-WP12,ZX1,ZX3,ZX5,ZX7,GT2, GT6,GT8,LS1,LS3,LS5,FP-TL1,FP-TL3, FP-TL5,FP-TL7,FP-TL9,FP-TL11,FP-TLS13, FP-TL15,FP-TL17,FP-TL19,FP-TR1,FP-TR3, FP-TR5,FP-TR7,FP-TR9,FP-TR11 We(ZhejiangFanpaointelligenttechnologyCo.,LTD)herebystatethatallthemodelsare electricalidenticalincludingthesamesoftwareparameterandhardwaredesign(i.e.,circuit design,PCBLayout,RFmodule/circuit,antennatype(s)andantennalocation,components onPCB,etc.,),samemechanicalstructureanddesign(includingproductenclosure, materials,etc.,),theonlydifferenceisthemodelnameandappearancecolor. Signatory Date:03-06.2024 Name:JinfaMiaoDate:Mar6.2024 Title:Manager Signatureofapplicant:

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Zhejiang Fanpao intelligent technology Co., LTD Company: Zhejiang Fanpao intelligent technology Co., LTD Address: Room 401, Building 2, Cangling No.Road 1-1, Hu Town, Jinyun County, Lishui City, Zhejiang Province,China Product Name: Fitness Walker Model Number: CS-WP8, CS-WP2, CS-WP6, CS-WP10, CS-WP11, CS- WP12, ZX1, ZX3, ZX5, ZX7, GT2, GT6, GT8, LS1, LS3, LS5, FP-TL1, FP- TL3, FP-TL5, FP-TL7, FP-TL9, FP-TL11, FP-TLS13, FP-TL15, FP-TL17, FP-TL19, FP-TR1, FP-TR3, FP-TR5, FP-TR7, FP-TR9, FP-TR11 FCC identifier: 2BEPD-FW We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Jinfa Miao Date: 2024.3.7 Title: Manager Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 Zhejiang Fanpao intelligent technology Co., LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2024-3-7 Subject: Request for Confidentiality FCC ID: 2BEPD-FW To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Jinfa Miao Title: Manager 2024.3.7

External Photos

Page1of3ReportNo.:FCS202401076 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202401076 Photo3 Photo4 Page3of3ReportNo.:FCS202401076 Photo5 Photo6

ID Label/Location Info

LabelandLabelLocation FCCID:2BEPD-FW

Internal Photos

Page1of6ReportNo.:FCS202401076 Internalphotos Photo1 Photo2 Page2of6ReportNo.:FCS202401076 Photo3 Photo4 Page3of6ReportNo.:FCS202401076 Photo5 Photo6 Page4of6ReportNo.:FCS202401076 Photo7 Photo8 Page5of6ReportNo.:FCS202401076 Photo9 Photo10 Page6of6ReportNo.:FCS202401076 Photo11

RF Exposure Info

FCC RF Exposure EUT Description:Fitness Walker ModelNo.:CS-WP8 Series Model: CS-WP2, CS-WP6, CS-WP10, CS-WP11, CS-WP12, ZX1, ZX3, ZX5, ZX7, GT2, GT6, GT8, LS1, LS3, LS5, FP-TL1, FP-TL3, FP-TL5, FP-TL7, FP-TL9, FP-TL11, FP-TLS13, FP-TL15, FP-TL17, FP-TL19, FP-TR1, FP-TR3, FP-TR5, FP-TR7, FP-TR9, FP-TR11 FCC ID: 2BEPD-FW 1. Test Procedure According to KDB 447498 D01 General RF Exposure Guidance v06 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances≤50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)]·[√f(GHz)]≤3.0 for 1-g SAR and≤7.5 for 10-g extremity SAR,wheref(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2. Test Result of RF ExposureEvaluation BT:[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]=3.94457/5*√2.480=1.2423≤3.0 Threshold at which no SAR required is and ≤ 3.0 for 1-g SAR, Separation distance is 5mm. Conclusion:no SAR required Mode Channel Freq. (MHz) Maximum Conducted Output Power(dBm) Antenna Gain (dBi) Antenna gain numeric GFSK 2402 4.11-0.580.875 0.00257632 1 2440 5.21-0.580.875 0.00331894 2480 5.96-0.580.875 0.00394457 Maximum Conducted Output Power(W)

Test Report

Inverted F Antenna Specification Summary ITEM ANT SPEC Model Name 2.4G ANT Center Frequency Horizontal Vertical 2400MHz 2400MHz2500MHz2400MHz2400MHz 2500MHz -1.26 -0.76 -0.58 -5.25 -2.46 -1.86 MAX. Gain -0.58dB Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance 50 Ohm Antenna Length 38.20mm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) 2400MHz 2450MHz2500MHz2400MHz2450MHz 2500MHz Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Frequency (MHz) Gain(dB) Max Min Avg 2400 -1.26174 -30.0801 -7.18716 2450 -0.765802 -36.5604 -7.48023 2500 -0.585582 -22.0315 -6.59127 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Frequency (MHz) Gain(dB) Max Min Avg 2400 -5.2537 -22.1424 -12.4294 2450 -2.4652 -24.5837 -10.4702 2500 -1.86120 -29.5214 -9.20432 ANT Test Labs:Attestation of Global Compliance Co., Ltd.

Test Report

FCCTestReport ReportNo:FCS202401076W01 Issuedfor Applicant: ZhejiangFanpaointelligenttechnologyCo.,LTD Address: Room401,Building2,CanglingNo.Road1-1,HuTown, JinyunCounty,LishuiCity,ZhejiangProvince,China ProductName: FitnessWalker BrandName: N/A ModelName: CS-WP8 SeriesModel: CS-WP2,CS-WP6,CS-WP10,CS-WP11,CS-WP12, ZX1,ZX3,ZX5,ZX7,GT2,GT6,GT8,LS1,LS3,LS5, FP-TL1,FP-TL3,FP-TL5,FP-TL7,FP-TL9,FP-TL11, FP-TLS13,FP-TL15,FP-TL17,FP-TL19,FP-TR1, FP-TR3,FP-TR5,FP-TR7,FP-TR9,FP-TR11 FCCID: 2BEPD-FW IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com Page 2 of38ReportNo.:FCS202401076W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TESTRESULTCERTIFICATION Applicant’sName......................:ZhejiangFanpaointelligenttechnologyCo.,LTD Address......................................: Room401,Building2,CanglingNo.Road1-1,HuTown,Jinyun County,LishuiCity,ZhejiangProvince,China Manufacture'sName................:ZhejiangFanpaointelligenttechnologyCo.,LTD Address......................................: Room401,Building2,CanglingNo.Road1-1,HuTown,Jinyun County,LishuiCity,ZhejiangProvince,China ProductDescription ProductName ........................... :FitnessWalker BrandName ............................... :N/A ModelName..............................:CS-WP8 SeriesModel..............................: CS-WP2,CS-WP6,CS-WP10,CS-WP11,CS-WP12,ZX1,ZX3, ZX5,ZX7,GT2,GT6,GT8,LS1,LS3,LS5,FP-TL1,FP-TL3, FP-TL5,FP-TL7,FP-TL9,FP-TL11,FP-TLS13,FP-TL15, FP-TL17,FP-TL19,FP-TR1,FP-TR3,FP-TR5,FP-TR7,FP-TR9, FP-TR11 TestStandards .......................... :FCCRulesandRegulationsPart15SubpartC,Section247 TestProcedure .......................... :ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedbyFluxComplianceServiceLaboratory,thetestresults showthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditis applicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFluxCompliance ServiceLaboratory,thisdocumentmaybealteredorrevisedbyFluxComplianceServiceLaboratory, personalonly,andshallbenotedintherevisionofthedocument.. Date(s)ofperformanceoftests . :Jan26,2024~Feb1,2024 DateofIssue.................................:Feb21,2024 TestResult....................................:Pass Testedby: (ScottShen) Reviewedby : (DukeQian) Approvedby: (JackWang) Page 3 of38ReportNo.:FCS202401076W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS...........................................................................................6 1.1TESTFACTORY............................................................................................................7 1.2MEASUREMENTUNCERTAINTY.................................................................................7 2.GENERALINFORMATION...................................................................................................8 2.1GENERALDESCRIPTIONOFTHEEUT.......................................................................8 2.2BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED............10 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS...............11 2.4EQUIPMENTSLIST.....................................................................................................12 3.CONDUCTEDEMISSIONMEASUREMENT.......................................................................13 4.6DBBANDWIDTH...............................................................................................................17 4.1Limit..............................................................................................................................17 4.2TestProcedure.............................................................................................................17 4.3Testsetup.....................................................................................................................17 4.4Testresults...................................................................................................................17 4.5OriginalTestData.........................................................................................................18 5.CONDUCTEDOUTPUTPOWER........................................................................................21 5.1LIMIT............................................................................................................................21 5.2TESTPROCEDURE.....................................................................................................21 5.3TESTSETUP...............................................................................................................21 5.5TESTRESULTS...........................................................................................................21 6.BANDEDGEANDSPURIOUS(CONDUCTED)..................................................................22 6.1LIMIT............................................................................................................................22 6.2TESTPROCEDURE.....................................................................................................22 6.3TESTSETUP...............................................................................................................22 6.4TESTRESULTS...........................................................................................................23 6.5Originaltestdata..........................................................................................................23 7.POWERSPECTRALDENSITY....................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of2ReportNo.:FCS202304114 Blow1GHzforradiatedemissiontestsetup Above1GHzforradiatedemissiontestsetup Page 2 of2ReportNo.:FCS202304114 ConductedEmission

Contact Information

Applicant

Jinfa Miao
[email protected]+86 13580712713Fax: 0578-3052368

Technical Contact

Flux Compliance Service LaboratoryAndy yue
[email protected]86-769-27280901

Dongguan · China

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]13510297284

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.94 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.