FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ShenZhen GoodlyMed Technology Co.,Ltd./
  3. 2BERFA01SLB001

2BERFA01SLB001Upper arm electronic blood pressure monitor with Bluetooth Low Energy

ShenZhen GoodlyMed Technology Co.,Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 03, 2024
Application Purpose
Original Equipment
Date of Application
Sep 02, 2024
Equipment Note
Upper arm electronic blood pressure monitor with Bluetooth Low Energy
Frequency Range
2402.00000000 - 2480.00000000
Company
ShenZhen GoodlyMed Technology Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

ID Label/Location Info

↗
↗
↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

ShenZhen GoodlyMed Technology Co.,Ltd. Date: 08-15-2024 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(5)(i) and Part 2.911(d)(5)(ii) Filing Re. KDB 986446 D01 FCC ID: (2BERFA01SLB001) Dear Sir or Madam, [ShenZhen GoodlyMed Technology Co.,Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, [ShenZhen GoodlyMed Technology Co.,Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [ is not] identified on the Covered List ( as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment . If you have any questions, please contact us. Sincerely, Contact name: Maria Ma Company name: ShenZhen GoodlyMed Technology Co.,Ltd. Address:701, Building C, Area C, Datianyang Industrial Zone, Shiwei Community, Matian Street, Guangming District, 518107 Shenzhen, PEOPLES REPUBLIC OF CHINA E-mail: [email protected] Tel: 18002580887

Cover Letter(s)

ShenZhen GoodlyMed Technology Co.,Ltd. Date (08/05/2024) TUV SUD BABT UNLIMITED TCB Octagon House, Segensworth North, Fareham, Hampshire, PO15 5RL, United Kingdom Confidentiality Request FCC ID: 2BERFA01SLB001 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, (ShenZhen GoodlyMed Technology Co.,Ltd.) hereby requests permanent confidential treatment of information accompanying this application as outlined below: << List of Exhibits either by name or type e.g. “Schematics” [exhibit type] or “Design Drawings” [description of data which must be uploaded ] >> [Common exhibits for which confidentiality is requested are:d Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation] (ShenZhen GoodlyMed Technology Co.,Ltd.) also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of (180) days: << List of Exhibits either by name or type e.g. “Internal Photos” [exhibit type]>> [Common exhibits for which short-term confidentiality is requested are: Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer:Maria Ma Telephone Number:18002580887 Email:[email protected]

Cover Letter(s)

ShenZhen GoodlyMed Technology Co.,Ltd. Date: 2024-08-05 TUV SUD BABT UNLIMITED TCB Octagon House, Segensworth North, Fareham, Hampshire, PO15 5RL, United Kingdom We, ShenZhen GoodlyMed Technology Co.,Ltd. (Address: 701, Building C, Area C, Datianyang Industrial Zone, Shiwei Community, Matian Street, Guangming District, 518107 Shenzhen, Guangdong,PEOPLE'S REPUBLIC OF CHINA ) Hereby declare: Product name: Upper Arm Electronic Blood Pressure Monitor FCC ID: 2BERFA01SLB001 All models are identical in RF module, PCB layout, main schematic, critical components and main software. The differences are listed in the below table. Model list for below table: Model name A01-SLB A01-BS A01-BL Dimension 129x97x46mm 129x97x46mm 129x97x46mm Power supply The same Voice With With Without Backlight with Without with Bluetooth With With With Hardware The same Schematic The same PCB layout The same Software Sampling circuits, algorithms are the same. The difference for models A01-SLB, A01-BS and A01-BL are only in the voice and backlight functions. Yours sincerely, Company Officer:Maria Ma Telephone Number:18002580887 Email:[email protected]

Cover Letter(s)

ShenZhen GoodlyMed Technology Co.,Ltd. Date: 2024-05-06 To: Federal Communications Commission 7435 Oakland Mills Road Columbia MD FCC ID: 2BERFA01SLB001 To Whom It May Concern: This letter is to ascertain that ShenZhen GoodlyMed Technology Co.,Ltd Product name: Upper Arm Electronic Blood Pressure Monitor , Models: A01-SLB, A01-BS, A01-BL have been the units used for conducting FCC compliance testing, the SDoC part will be tested by FCC recognized test lab. If you have any question or concerns, please contact us. Sincerely, Company Officer: Maria Ma Telephone Number:18002580887 Email:[email protected]

ID Label/Location Info

RATING LABEL: 注:标签位置及丝印图纸

ID Label/Location Info

RATING LABEL: 注:标签位置及丝印图纸

ID Label/Location Info

RATING LABEL: 注:标签位置及丝印图纸

RF Exposure Info

Report Number: 68.930.23.0054.01A TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 2 RF Exposure Evaluation Product: Upper Arm Electronic Blood Pressure Monitor Model no.: A01-SLB, A01-BS, A01-BL FCC ID: 2BERFA01SLB001 Rating: 6VDC (4*AAA batteries) or 5.0Vdc, 1.0A (type-C port, supplied by a separate approved medical adaptor) RF Transmission Frequency: 2402MHz-2480MHz Modulation: GFSK Antenna Type: PCB Antenna Max Antenna Gain: -13.73 dBi Description of the EUT: The Equipment Under Test (EUT) is an Upper Arm Electronic Blood Pressure Monitor which support Low Energy Bluetooth(1M). Reference Report 68.930.23.0054.01 1. Limit and Guidelines on Exposure to Electromagnetic Fields According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D01 General RF Exposure Guidance v06, Mobile Portable RF Exposure, no SAR required if power is lower than the flowing threshold: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where • f(GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation25 • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. 2. Calculation method [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 For GFSK Modulation 2402MHz Radiated Power + tune up tolerance = 0.097 mW Distance = 5 mm f = 2.402 GHz [0.097/5] * SQRT(2.402) =0.03 0.03≤ 3.0 Report Number: 68.930.23.0054.01A TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 2 Therefore, excluded from SAR testing. TUV SUD China, Shenzhen Branch Reviewed by: Prepared By: John Zhi/ EMC Project Manager Grace Gao/EMC Project Engineer Date: 2024-05-06 Date: 2024-05-06

Test Report

1 / 3 一、Description Sample Model BLE04 Antenna manufacturer Dongguan Lanyi Communication Technology co.,Ltd Antenna Size 10.1*4.0mm Antenna Type PCB antenna Serial No. / Test Item Antenna gain; Efficiency; Radiation pattern Frequeney Range 2400MHz-2500MHz Test Date 2022.10.28 二、Antenna Photo & Length (mm) 三、Typical free space gain 四、Typical free space radiation pattern 2 / 3 3 / 3

Test Report

Report Number: 68.930.23.0054.01 EMC_SZ_FR_80.00 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 44 FCC - TEST REPORT Report Number : 68.930.23.0054.01 Date of Issue: 15 August, 2024 Model : A01-SLB, A01-BS, A01-BL Product Type : Upper Arm Electronic Blood Pressure Monitor Applicant : ShenZhen GoodlyMed Technology Co.,Ltd. Address : 701, Building C, Area C, Datianyang Industrial Zone, Shiwei Community, Matian Street, Guangming District, 518107 Shenzhen, Guangdong,PEOPLE'S REPUBLIC OF CHINA Manufacturer : ShenZhen GoodlyMed Technology Co.,Ltd. Address : 701, Building C, Area C, Datianyang Industrial Zone, Shiwei Community, Matian Street, Guangming District, 518107 Shenzhen, Guangdong,PEOPLE'S REPUBLIC OF CHINA Production Facility : ShenZhen GoodlyMed Technology Co.,Ltd. Address : 701, Building C, Area C, Datianyang Industrial Zone, Shiwei Community, Matian Street, Guangming District, 518107 Shenzhen, Guangdong,PEOPLE'S REPUBLIC OF CHINA Test Result : ◼ Positive  Negative Total pages including Appendices : 44 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 68.930.23.0054.01 EMC_SZ_FR_80.00 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 44 1 Table of Contents 1 Table of Contents......................................................................................................................................................... 2 2 Details about the Test Laboratory .............................................................................................................................. 3 3 Description of the Equipment Under Test .................................................................................................................. 4 4 Summary of Test Standards ....................................................................................................................................... 5 5 Summary of Test Results ............................................................................................................................................ 6 6 General Remarks ......................................................................................................................................................... 7 7 Test Setups .................................................................................................................................................................. 8 8 Systems Test Configuration ...................................................................................................................................... 10 9 Technical Requirement.............................................................................................................................................. 11 9.1 Conducted Emission ......................................................................................................................................... 11 9.2 Conducted Peak Output Power ........................................................................................................................ 14 9.3 Power Spectral Density ..................................................................................................................................... 18 9.4 6 dB Bandwidth .................................................................................................................................................. 21 9.5 Spurious RF Conducted Emissions ................................................................................................................. 24 9.6 Band Edge ......................................................................................................................................................... 28 9.7 Spurious Radiated Emissions for Transmitter ................................................................................................. 31 10 Test Equipment List ............................................................................................................................................... 42 11 System Measurement Uncertainty ....................................................................................................................... 44 Report Number: 68.930.23.0054.01 EMC_SZ_FR_80.00 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 44 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 FCC Registration No.: 514049 FCC Designation Number: CN5009 Report Number: 68.930.23.0054.01 EMC_SZ_FR_80.00 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 44 3 Description of the Equipment Under Tes…

Text truncated - open the document above for the full version.

Contact Information

Applicant

zihan zhao
[email protected]18002580887Fax: 18002580887

Test Firm

TUV SUD Cert & Testing (China) Co., Ltd.Harry Zhou
[email protected]86 755 3332 3281

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz970.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is peak conducted output power.