FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. GUANGDONG DP CO., LTD./
  3. 2BEU2-DP-HW1000L

2BEU2-DP-HW1000Lportable power station

GUANGDONG DP CO., LTD.
portable power station - FCC ID 2BEU2-DP-HW1000L - GUANGDONG DP CO., LTD.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
May 18, 2024
Application Purpose
Original Equipment
Date of Application
May 18, 2024
Equipment Note
portable power station
Frequency Range
0.11200000 - 0.20500000
Company
GUANGDONG DP CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐‐ Reorient or relocate the receiving antenna. ‐‐ Increase the separation between the equipment and receiver. ‐‐Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐‐ Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The device has been evaluated to meet general RF exposure requirement.

Attestation Statements

GUANGDONG DP CO., LTD. 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – EquipmentType Company name: GUANGDONG DP CO., LTD. Address: No.12 Keyuan Road, Private Science Park, Baiyun District, Guangzhou, China Product Name: portable power station FCCID: 2BEU2-DP-HW1000L Model(s): DP-HW1000L 2.911(d)(5)(i) EquipmentType We, [GUANGDONG DP CO., LTD.] (“the applicant”) certify that the equipment for which authorization is sought through certification is not:  Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules.  Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: TEN Qin Date: Jan. 30, 2024 Title: Research and Development Manager Company name: GUANGDONG DP CO., LTD. Signature: NOTE 1 “Covered List ”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

GUANGDONG DP CO., LTD. 2.911 (d)(5)(ii) Applicant Attestation v1.3 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: GUANGDONG DP CO., LTD. Address: No.12 Keyuan Road, Private Science Park, Baiyun District, Guangzhou, China Product Name: portable power station FCCID: 2BEU2-DP-HW1000L Model(s): DP-HW1000L 2.911(d)(5)(ii) Applicant filing We, [GUANGDONG DP CO., LTD.] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is is not identified NOTE 1 on the “Covered List” NOTE 2 ,established pursuant to §1.50002 of this chapter,as an entity producing coveredcommunications equipment. Yours sincerely, Name: TEN Qin Date: Jan. 30, 2024 Title: Research and Development Manager Company name: GUANGDONG DP CO., LTD. Signature: NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List ”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

GUANGDONG DP CO., LTD. 2.911 (d)(7)USA Agentv1.3 Section 2.911(d)(7) USA Agent for Service of Process Company name: GUANGDONG DP CO., LTD. Address: No.12 Keyuan Road, Private Science Park, Baiyun District, Guangzhou, China. Product Name: portable power station FCCID: 2BEU2-DP-HW1000L Model(s): DP-HW1000L 2.911(d)(7) USA Designated Agent for Service of Process We, [GUANGDONG DP CO., LTD.] (“the applicant”) designate [GSS SERVICE INC] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We Acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We Acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. GUANGDONG DP CO., LTD. 2.911 (d)(7)USA Agentv1.3 USA Agent Company name: GSS SERVICE INC Address: 6547 N Academy Blvd #2266 Colorado Springs COLORADO 80918, United States FCC Registration Number (FRN): 0033402082 Contact Name: Ms Michoux Logan Telephone No: 001-949-2990192 Email: [email protected] Applicant Company name: GUANGDONG DP CO., LTD. Address: No.12 Keyuan Road, Private Science Park, Baiyun District, Guangzhou, China. FCC Registration Number (FRN): 0034829291 FCC Grantee Code: 2BEU2 Contact Name: TEN Qin Telephone No: 13416124564 Email: [email protected] Signature: Title: Manager Signature: Title: Research and Development Manager Date: Jan. 30, 2024 Date: Jan. 30, 2024 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process. Reference;Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the

Cover Letter(s)

GUANGDONG DP CO., LTD. Agent Authorization Company: GUANGDONG DP CO., LTD. Address: No.12 Keyuan Road, Private Science Park, Baiyun District, Guangzhou, China Product Name: portable power station Model Number(s): DP-HW1000L Product Description: portable power station We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Jan. 30, 2024 Name: TEN Qin Title: Research and Development Manager Company: GUANGDONG DP CO., LTD.

Cover Letter(s)

GUANGDONG DP CO., LTD. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Jan. 30, 2024 Subject; Request for Confidentiality FCC ID: 2BEU2-DP-HW1000L To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: TEN Qin Title: Research and Development Manager

ID Label/Location Info

FCC ID LABEL: Ca. 30mm x 40mm label location FCC ID: 2BEU2‐DP‐HW1000L

Internal Photos

Annex B Internal Photo Report No.: HK2310164780-1E/2E Page 1 of 4 Report No.: HK2310164780-1E/2E Page 2 of 4 Antenna Report No.: HK2310164780-1E/2E Page 3 of 4 Report No.: HK2310164780-1E/2E Page 4 of 4

RF Exposure Info

Page 1 of 11 Report No.: HK2310164780-2E FCC Test Report Test Report On Behalf of GUANGDONG DP CO., LTD. For portable power station Model No.: DP-HW1000L FCC ID: 2BEU2-DP-HW1000L Prepared For: GUANGDONG DP CO., LTD. No.12 Keyuan Road, Private Science Park, Baiyun District, Guangzhou, China Prepared By: Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Oct. 16, 2023 ~ May. 08, 2024 Date of Report: May. 08, 2024 Report Number: HK2310164780-2E Page 2 of 11 Report No.: HK2310164780-2E Test Result Certification Applicant’s Name ................. : GUANGDONG DP CO., LTD. Address.................................. : No.12 Keyuan Road, Private Science Park, Baiyun District, Guangzhou, China Manufacture's Name ............ : GUANGDONG DP CO., LTD. Address.................................. : No.12 Keyuan Road, Private Science Park, Baiyun District, Guangzhou, China Product Description Trade Mark ................................ : DP Product Name ........................... : portable power station Model and/or Type Reference: DP-HW1000L Standards ............................. : FCC CFR 47 PART 15, KDB 680106 D01 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of Performance of Tests ............ : Oct. 16, 2023 ~ May. 08, 2024 Date of Issue ........................................... : May. 08, 2024 Test Result ............................................... : Pass Testing Engineer : (Len Liao) Technical Manager : (Sliver Wan) Authorized Signatory : (Jason Zhou) Page 3 of 11 Report No.: HK2310164780-2E Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2. Frequency Band: 112-205KHz Channel List Channel Frequency (KHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) Middle CH 118 The EUT antenna is Coil Antenna. No antenna other than that furnished by the responsible party shall be used with the device. 2. Summary of Test Results 2.1. Test procedures according to the technical standards: FCC KDB 680106 D01 Wireless Power Transfer v04 FCC CFR 47 Standard Section Test Item Judgment Remark FCC CFR 47 part1, 1.1310 KDB 680106 D01v04 Electric Field Strength (E) (V/m) PASS Magnetic Field Strength (H) (A/m) PASS 2.2. Measurement Uncertainty The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 All Emissions, Radiated(<30M)(9KHz-30MHz) ±3.90dB 2 Temperature ±0.5°C 3 Humidity ±2% Page 4 of 11 Report No.: HK2310164780-2E 2.3. Test Instruments Description Brand Model No. S/N Calibrated Date Calibrated Until Magnetic Amplitude and Gradient Probe System SPEAG MAGPy-8H3D +E3D V2 & MAGPy-DAS V2 SZ186-06 & 3061 Apr. 13, 2023 Apr. 12, 2024 NOTE: 1. the calibration interval of the above test instruments is 12 months. Page 5 of 11 Report No.: HK2310164780-2E 3. Maximum Permissible Exposure Limit of Maximum Permissible Exposure Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180 / f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1 30 Note 1: f = frequency in MHz; *Plane-wave equivalent power density. Note 2: For the applicable limit, see FCC 1.1310, 680106 D01 Wireless Power Transfer v04. Note 3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. Page 6 of 11 Report No.: HK2310164780-2E 4. Test Procedure a. For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of H-field & E- field strengths for all sides is 0-20cm. E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 0-20 cm measured from the center of the probe(s) to the edge of the device. 4.1 Test Setup 4.2 Result of Maximum Permissible Exposure All test modes are tested, and the report shows only the worst mode: Full Load mode H-Field Strength at 0-20 cm from the edges surrounding the EUT (A/m) Measuring distance (cm) Field strength Test Position A Test Position B Test Position C Test Position D Test Position E Test Position F Limits (A/m) 0 A/m 0.795 0.755 0.689 0.712 0.669 0.703 1.63 2 A/m 0.782 0.713 0.624 0.735 0.647 0.754 1.63 4 A/m 0.702 0.698 0.694 0.719 0.674 0.685 1.63 6 A/m 0.697 0.622 0.633 0.694 0.583 0.582 1.63 8 A/m 0.611 0.604 0.513 0.530 0.590 0.559 1.63 10 A/m 0.549 0.531 0.518 0.613 0.606 0.517 1.63 12 A/m 0.569 0.545 0.493 0.506 0.477 0.450 1.63 14 A/m 0.499 0.467 0.413 0.436 0.414 0.566 1.63 16 A/m 0.431 0.464 0.397 0.354 0.403 0.412 1.63 18 A/m 0.402 0.317 0…

Text truncated - open the document above for the full version.

Test Report

      !"# $%& ''' $%()*& +",-./01-203455 6 7"189/.!:-8,-!;!.3 < =>?@?ABC D >A?@BA?@ E =AB> F GB> H @ABC I CA J >?>BA?@ K @?GBA?@ L =MBA?@ N GOPQ R MOPQ PSSTUPUVTS +"WXYZ[55 4\6 ]^_]`a5ZXYabXYc]d^aYZ +`7adYXebfca]eba_e^f_g^fh 7":]ie^g^dZYdacj^a]Xebfc ]YXc5 Y_fa^iZ^ij^a]dgeak a]d^le\5Y_fa^iZ^i^dm# B+55ka]^ffX]eg^d m"#55 ka]a]^infdd^d#"[B #"755 kYfca]oYin_gb^d ZYdach

Test Report

Page 1 of 24 Report No.: HK2310164780-1E FCC Test Report Test Report On Behalf of GUANGDONG DP CO., LTD. For portable power station Model No.: DP-HW1000L FCC ID: 2BEU2-DP-HW1000L Prepared For: GUANGDONG DP CO., LTD. No.12 Keyuan Road, Private Science Park, Baiyun District, Guangzhou, China Prepared By: Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Jan. 09, 2024 ~ May. 08, 2024 Date of Report: May. 08, 2024 Report Number: HK2310164780-1E Page 2 of 24 Report No.: HK2310164780-1E Test Result Certification Applicant’s Name ................. : GUANGDONG DP CO., LTD. Address.................................. : No.12 Keyuan Road, Private Science Park, Baiyun District, Guangzhou, China Manufacturer's Name .......... : GUANGDONG DP CO., LTD. Address.................................. : No.12 Keyuan Road, Private Science Park, Baiyun District, Guangzhou, China Product Description Trade Mark ................................ : DP Product Name ........................... : portable power station Model and/or Type Reference: DP-HW1000L Standards ............................. : FCC Rules and Regulations Part 15 Subpart C (Section 15.209), ANSI C63.10: 2013 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of Performance of Tests ............ : Jan. 09, 2024 ~ May. 08, 2024 Date of Issue ........................................... : May. 08, 2024 Test Result ............................................... : Pass Testing Engineer : (Len Liao) Technical Manager : (Sliver Wan) Authorized Signatory : (Jason Zhou) Page 3 of 24 Report No.: HK2310164780-1E Table of Contents Page 1 . Test Summary 5 1.1 . Test Procedures and Results 5 1.2 . Information of the Test Laboratory 5 1.3 . Measurement Uncertainty 5 2. General Information 6 2.1. General Description of EUT 6 2.2. Carrier Frequency of Channels 7 2.3. Operation of EUT during Testing 7 2.4. Description of Test Setup 8 2.5. Description of Support Units 9 2.6. Measurement Instruments List 10 3. Conducted Emission Test 11 3.1. Block Diagram of Test Setup 11 3.2. Conducted Power Line Emission Limit 11 3.3. Test Procedure 11 3.4. Test Result 12 4. Radiated Emissions 14 4.1. Block Diagram of Test Setup 14 4.2. Rules and Specifications 15 4.3. Test Procedure 16 4.4. Test Result 17 5. Antenna Requirement 21 6. Photograph of Test 22 7. Photos of the EUT 24 Page 4 of 24 Report No.: HK2310164780-1E ** Modified History ** Revision Description Issued Data Remark Revision 1.0 Initial Test Report Release May. 08, 2024 Jason Zhou Page 5 of 24 Report No.: HK2310164780-1E 1. Test Summary 1.1. Test Procedures and Results Description of Test Section Number Result CONDUCTED EMISSIONS TEST 15.207 COMPLIANT RADIATED EMISSION TEST 15.209 COMPLIANT ANTENNA REQUIREMENT 15.203 COMPLIANT Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. 1.2. Information of the Test Laboratory Shenzhen HUAK Testing Technology Co., Ltd. Add.: 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Testing Laboratory Authorization: A2LA Accreditation Code is 4781.01. FCC Designation Number is CN1229. Canada IC CAB identifier is CN0045. CNAS Registration Number is L9589. 1.3. Measurement Uncertainty Measurement Uncertainty Conducted Emission Expanded Uncertainty = 2.71dB, k=2 Radiated emission expanded uncertainty(9kHz-30MHz) = 3.90dB, k=2 Radiated emission expanded uncertainty(30MHz-1000MHz) = 3.90dB, k=2 Radiated emission expanded uncertainty(Above 1GHz) = 4.28dB, k=2 Page 6 of 24 Report No.: HK2310164780-1E 2. General Information 2.1. General Description of EUT Equipment: portable power station Model Name: DP-HW1000L Series Models: N/A Model Difference: N/A Trade Mark: N/A FCC ID: 2BEU2-DP-HW1000L Antenna Type: Coil Antenna Antenna Gain: 0dBi Operation Frequency: 112KHz~205KHz Test Frequency: 118KHz Number of Channels: 1 Modulation Type: ASK Power Source: DC Input: 12-26VDC, 180W Max. PV Input: 12-26VDC, 8A DC5521 Output: 12VDC, 5A Cigarette lighter Output: 12VDC, 10A Wireless Output: 15W USB-A Output: 5VDC or 9VDC or 12VDC, 18W Max. USB-C Output: 5VDC or 9VDC or 12VDC or 15VDC or 20VDC, 60W Max. AC Output: 230V, 50Hz, 1000W Battery capacity: 22.4V, 45Ah, 1008Wh Power Rating: DC Input: 12-26VDC, 180W Max. PV Input: 12-26VDC, 8A DC5521 Output: 12VDC, 5A Cigarette lighter Output: 12VDC, 10A Wireless Output: 15W USB-A Output: 5VDC or 9VDC or 12VDC, 18W Max. USB-C Output: 5VDC or 9VDC or 12VDC or 15VDC or 20VDC, 60W Max. AC Output: 230V, 50Hz, 1000W Battery capacity: 22.4V, 45Ah, 1008Wh Page 7 of 24 Report No.: HK2310164780-1E 2.2. Carrier Frequency of Channels Operation Frequency each of channel Channel Frequency Middle CH 118KHz 2.3. Operation of EUT during Testing Test Item Test mode Description Radiated & Conducted test cases Mode 1AC/DC Adapter+ EUT +Wireless load (Full Load) Mode 2AC/DC Adapter+ EUT +Wireless load (Half Load) Mode 3AC/DC Adapter+ EUT +Wireless load (Null Load) Mode 4EUT +Wireless load (Full Load) Mode 5EUT +Wireless load (Half Load) Mode 6EUT +Wireless load (Null Load) Note: 1. All modes and configurations above have been tested, Only the result of the worst case was recorded in the report, the conducted worst-case configuration is Mode 1 and the radiated worst-case configur…

Text truncated - open the document above for the full version.

Test Setup Photos

Model: DP-HW1000L Radiated Emissions AC Mode: DC Mode: Conducted Emission

Contact Information

Applicant

TEN Qin
[email protected]13416124564Fax: 13416124564

Technical Contact

GUANGDONG DP CO., LTD
[email protected]

China

Test Firm

Shenzhen HUAK Testing Technology Co., Ltd.Jason Zhou
[email protected]86-755-23029901

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.112 MHz - 0.205 MHz-
Confidentiality
Long Term