This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction
Attestation Statements (January 31, 2024) TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (FCC ID: 2BEWZ-L5B83G ) (Tianchang Chuangxuan Network Technology Co., Ltd), the undersigned, hereby authorize (NEWENERGYER LIMITED) to act as our designated U.S. agent for service of process, (Tianchang Chuangxuan Network Technology Co., Ltd) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. (NEWENERGYER LIMITED) accepts the responsibility to act as designated U.S. agent for service of process, provides an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Information: Company name: Tianchang Chuangxuan Network Technology Co., Ltd Contact Name: Wu Fan Address: Zhenglong Road, Qinlan Town, Tianchang City, Anhui Province Telephone No: 13538214502 Email: [email protected] FRN: 0034841296 Signature [Wu Fan] U.S. Agent Information: Company Name: NEWENERGYER LIMITED Address: 1818 S Patton Ct, Denver, CO, 80219 Contact Name: CHUN LIU Telephone No: 213 289 5042 Email: [email protected] FRN: 0034665885 Signature [CHUN LIU]
(Tianchang Chuangxuan Network Technology Co., Ltd) (January 31, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2BEWZ-L5B83G) [Tianchang Chuangxuan Network Technology Co., Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) Wu Fan (Tianchang Chuangxuan Network Technology Co., Ltd) (January 31, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2BEWZ-L5B83G) [Tianchang Chuangxuan Network Technology Co., Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Wu Fan
Tianchang Chuangxuan Network Technology Co., Ltd Model Difference Data:January 31, 2024 Product description: Works with Amazon remote control Model name: L5B83G, L5B83H, RK01 Trade Name: N/A FCC ID: 2BEWZ-L5B83G All the model are the same circuit and RF module, except model names . Regards Sincerely Client’s signature : Client’s name / title : Wu Fan(legal person) Contact information / address:Zhenglong Road, Qinlan Town, Tianchang City, Anhui Province
Tianchang Chuangxuan Network Technology Co., Ltd (January 31, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Works with Amazon remote control / L5B83G , L5B83H, RK01/ FCC ID: 2BEWZ-L5B83G ) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: Wu Fan Title: legal person
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 3 Model: L5B83G External Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 3 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 3
FCC ID LABEL: Label Location: FCC ID: 2BEWZ-L5B83G Model No.: L5B83G
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 3 Model: L5B83G Internal Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 3 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 3 ANT
Shenzhen CTB Testing Co., Ltd. FCC ID:2BEWZ-L5B83G Portable device According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to KDB447498 D01 General RF Exposure Guidance V06 The 1-g SAR and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHZ)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f(GHZ) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. BLE: Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculatio n SAR Exclusion threshold SAR test exclusion 2.402 2.014 1.59 2±1 3.00 2.00 <5 0.61847 3.00 YES 2.44 3.238 2.11 3±1 4.00 2.51 <5 0.78474 3.00 YES 2.480 3.222 2.10 3±1 4.00 2.51 <5 0.79114 3.00 YES GFSK Conclusion: For the max result : 0.79114≤ FCC Limit 3.0 for 1g SAR.
天线说明 频点:2402-2480 Gain:1.25dbi Antenna Material:PCB板载天线 深圳市振业时代科技有限公司 深圳市振业时代科技有限公司 深圳市振业时代科技有限公司 Manufacturer: Tianchang Chuangxuan Network Technology Co., Ltd Address: Zhenglong Road, Qinlan Town, Tianchang City, Anhui Province
TEST REPORT Compiled by: Reviewed by: Approved by: Zhou Kui Arron Liu Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Product Name: Works with Amazon remote control FCC ID: 2BEWZ-L5B83G Trademark: N/A Model Number: L5B83G, L5B83H, RK01 Prepared For: Tianchang Chuangxuan Network Technology Co., Ltd Address: Zhenglong Road, Qinlan Town, Tianchang City, Anhui Province Manufacturer: Tianchang Chuangxuan Network Technology Co., Ltd Address: Zhenglong Road, Qinlan Town, Tianchang City, Anhui Province Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Jan. 23, 2024 Sample tested Date: Jan. 23, 2024 to Jan. 29, 2024 Issue Date: Jan. 29, 2024 Report No.: CTB240126113RFX Test Standards FCC Part15.247 ANSI C63.10:2013 Test Results PASS Remark: This is Bluetooth radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB240126113RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 33 TABLE OF CONTENT Test Report Declaration Page 1. VERSION ........................................................................................................................................ 3 2. TEST SUMMARY ........................................................................................................................... 4 3. MEASUREMENT UNCERTAINTY ................................................................................................. 5 4. PRODUCT INFORMATION AND TEST SETUP ............................................................................ 6 4.1 Product Information .......................................................................................................................... 6 4.2 Test Setup Configuration .................................................................................................................. 6 4.3 Support Equipment........................................................................................................................... 6 4.4 Channel List ..................................................................................................................................... 7 4.5 Test Mode ........................................................................................................................................ 7 4.6 Test Environment ............................................................................................................................. 7 5. TEST FACILITY AND TEST INSTRUMENT USED ....................................................................... 8 5.1 Test Facility ...................................................................................................................................... 8 5.2 Test Instrument Used ....................................................................................................................... 8 6. AC POWER LINE CONDUCTED EMISSION ................................................................................ 10 6.1 Block Diagram Of Test Setup ......................................................................................................... 10 6.2 Limit ................................................................................................................................................ 10 6.3 Test procedure ............................................................................................................................... 10 6.4 Test Result ..................................................................................................................................... 12 7. RADIATED SPURIOUS EMISSION ............................................................................................. 13 7.1 Block Diagram Of Test Setup ......................................................................................................... 13 7.2 Limit ................................................................................................................................................ 13 7.3 Test procedure ............................................................................................................................... 14 7.4 Test Result ..................................................................................................................................... 15 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS ............................................... 22 8.1 Block Diagram Of Test Setup ......................................................................................................... 22 8.2 Limit ................................................................................................................................................ 22 8.3 Test procedure ............................................................................................................................... 22 8.4 Test Result ..................................................................................................................................... 23 9. COUDUCTED OUTPUT POWER ................................................................................................. 25 9.1 Block Diagram Of Test Setup ......................................................................................................... 25 9.2 …
Text truncated - open the document above for the full version.
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 1 Model: L5B83G Radiated Emission Below 1G Above 1G
Zhenglong Road, Qinlan Town · Tianchang City, Anhui Province · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.11 mW |