FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TEIJIN FRONTIER CO., LTD./
  3. 2BEXRRHM920T002

2BEXRRHM920T002Wearable RFID Reader

TEIJIN FRONTIER CO., LTD.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 13, 2026
Application Purpose
Original Equipment
Equipment Note
Wearable RFID Reader
Frequency Range
2402.00000000 - 2480.00000000
Company
TEIJIN FRONTIER CO., LTD.
Country
Japan

Documents & Files

Select a file to view

Attestation Statements

β†—
β†—
β†—

Cover Letter(s)

β†—
β†—

ID Label/Location Info

β†—

RF Exposure Info

β†—
β†—
β†—
β†—
β†—
β†—

Test Report

β†—
β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Date: 2026-01-15 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 To Whom It May Concern: I, the undersigned, hereby authorize Compliance Testing, LLC. and hereafter refer red to as Compliance Testing, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Compliance Testing on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing Compliance Testing as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sin cerely Yours, Y oshiaki Hirano General Manager TEIJIN FRONTIER CO., LTD. REMARK: 1. This authorization letter will be sent along with your application when filing with the Certification Division. 2. Please follow the format and type it on company letterhead and send original to us. 3. Authorized signature must be in agreement with grantee code contact in FCC database.

Attestation Statements

T EIJIN FRONTIER(U.S.A.), INC. 1412 Broadway Suite1500, New York, NY 10018 U.S. AGENT LETTER OF ATTESTATION FCC US Agent FRN: 0034944983 Com pany Name: TEIJIN FRONTIER (U.S.A.), INC. Contact Name: Yuki Kuwabara Address: 1412 Broadway, Suite 1500, New York, N.Y. 10018 U.S.A. Telephone No: +1-212-840-6900 E mail: [email protected] TO: Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 ATTENTION: Federal Communications Commission (FCC) This letter is to confirm that we have accepted the responsibility to act as the U.S. based Agent on behalf of the Applicant noted below for all future FCC certification/registrations obtained during the period of this agreement which ends at the specified date below (if applicable). As the U.S. Agent, we are aware of the requirements involved as outlined in section 2.911(d)(7) of the FCC rules and of KDB 986446 D01v01. Applicant FRN: 0034841460 Applicant Name: TEIJIN FRONTIER CO., LTD. Grantee Code: 2BEXR Contact Name: Yoshiaki Hirano Address: NBF Comodio Shiodome 2-14-1, Higashishimbashi, Minato-ku, Tokyo 105-0021, Japan Telephone No: +81-3-6402-7039 E mail: [email protected] We TEIJIN FRONTIER CO., LTD. will maintain this agent in the U.S. for no less than one year after either all marketing or importation to the U.S. is terminated (or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment), whichev er is later. TEIJIN FRONTIER (U.S.A.), INC. TEIJIN FRONTIER CO., LTD. By Yuki Kuwabara By Yoshiaki Hirano Authorized Signature Authorized Signature Yu ki Kuwabara Yoshiaki Hirano General Manager General Manager Date: January 15th, 2026 Date: January 15th, 2026

Attestation Statements

Date: 2026-01-15 FCC ID: 2BEXRRHM920T002 To the attention of Federal Communications Commission Authorization and Evaluation Division Attestation Statements Attestation Statements Part 2.911(d)(5)(i) Filing TEIJIN FRONTIER CO., LTD. certifies that the equipment for which authorization is sought is not β€œcovered” equipment prohibited from receivingan equipment authorization pursuant to section 2.903 of the FCC rules. Attestation Statements Part 2.911(d)(5)(ii) Filing TEIJIN FRONTIER CO., LTD. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing β€œcovered” equipment. Sincerely yours, ----------------------------------------------- Yoshiaki Hirano General Manager TEIJIN FRONTIER CO., LTD.

Cover Letter(s)

Date: 2026-01-15 FCC ID: 2BEXRRHM920T002 To the attention of Federal Communications Commission Authorization and Evaluation Division Permanent Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Schematics Block Diagram Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely yours, ----------------------------------- Yoshiaki Hirano General Manager TEIJIN FRONTIER CO., LTD.

Cover Letter(s)

Date: 2026-01-15 FCC ID: 2BEXRRHM920T002 To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we request short-term confidential treatment for the following information until 180days after the Grant Date of Equipment Authorization in order to ensure sensitive business information remains confidential until the actual marketing of the device: External photos Test Setup photos User’s manual Internal Photos Sincerely yours, ----------------------------------- Yoshiaki Hirano General Manager TEIJIN FRONTIER CO., LTD.

ID Label/Location Info

RecoHand Label Format (Unit : mm) MODEL:M920SRW-B R 011-180006 FCC ID:2BEXRRHM920T002 IC:32014-RHM920T0002 TEIJIN FRONTIER CO., LTD. S/N:901016R MADE IN JAPAN 30Β±0.25 20 Β± 0.25 3-R1.0 C2.0 Labels are printed in indelible ink on permanent adhesive backing at a specific location on the EUT, and it will be readily visible to the purchaser at the time of purchase

RF Exposure Info

Next Generation Test Laboratory Inc. (RF Safety Laboratory, LLC) 5520 Research Park Drive, Suite 140, Catonsville, Maryland 21228 USA ISED Lab Code: 32002; FCC Designation Number: US3274 ANAB 17025 Certificate Number: AT-3274; CAB Identifier: US0239 ☎+1 202 240 9240; ο“§ο“§[email protected] FCC ID: 2BEXRRHM920T002 IC: 32014-RHM920T002 SAR-001: SAR Test Report RevA Test Report S/N: 2025.044.01 Page 1 of 15 SAR EVALUATION REPORT FCC ID: 2BEXRRHM920T002 IC: 32014-RHM920T002 HVIN/Model(s): M920SRW-B PMN: RecoHand FVIN: 4.00 Device Type: Portable Device Report Issue Date: March 30, 2026 Teijin Frontier Co., Ltd. NBF Comodio Shiodome 2-14-1, Higashishimbashi, Minato-ku, Tokyo 105-0021, Japan Certification The measurement evaluations presented in this report are based on the maximum performance of the tested device(s), which has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment / general population exposure federal limits in 47CFR Β§ 1.1310 and Health Canada Safety Code 6 and has been tested in accordance with the measurement procedures specified within this report. This document must be reproduced in its entirety without any alterations unless with written permission from RF Safety Laboratory, LLC. Steve Liu President FCC Equipment Class Body SAR [W/kg] Extremity SAR [W/kg] 1g Simultaneous Tx SAR [W/kg] 10g Simultaneous Tx SAR [W/kg] DSS0.740.280.870.33 DTS--0.870.33 FCC Limit1.64.01.64.0 Next Generation Test Laboratory Inc. (RF Safety Laboratory, LLC) 5520 Research Park Drive, Suite 140, Catonsville, Maryland 21228 USA ISED Lab Code: 32002; FCC Designation Number: US3274 ANAB 17025 Certificate Number: AT-3274; CAB Identifier: US0239 ☎+1 202 240 9240; ο“§ο“§[email protected] FCC ID: 2BEXRRHM920T002 IC: 32014-RHM920T002 SAR-001: SAR Test Report RevA Test Report S/N: 2025.044.01 Page 2 of 15 Table of Contents 1. DUT Specifics ................................................................................................................................................. 3 2. Bluetooth LE SAR Test Exemption Assessment ............................................................................................. 4 3. DUT Conducted Powers ................................................................................................................................ 5 4. DUT SAR Test Results .................................................................................................................................... 6 5. DUT SAR Measurement Variability Requirement .......................................................................................... 7 6. General Introduction..................................................................................................................................... 7 7. Background on Radiofrequency (RF) Exposure Limits ................................................................................... 7 8. RF Safety Laboratory SAR Measurement System .......................................................................................... 9 9. Technology Specific Test Setup Requirements ............................................................................................ 12 10. Equipment List ............................................................................................................................................ 13 11. Conclusion................................................................................................................................................... 15 Appendix A: SAR Test Plots Appendix B: Tissue Stimulating Liquids, System Checks and System Validation Appendix C: System Check Plots Appendix D: Calibration Certificates Appendix E : Simultaneous Transmission Analysis Appendix F : Test Setup Photos Next Generation Test Laboratory Inc. (RF Safety Laboratory, LLC) 5520 Research Park Drive, Suite 140, Catonsville, Maryland 21228 USA ISED Lab Code: 32002; FCC Designation Number: US3274 ANAB 17025 Certificate Number: AT-3274; CAB Identifier: US0239 ☎+1 202 240 9240; ο“§ο“§[email protected] FCC ID: 2BEXRRHM920T002 IC: 32014-RHM920T002 SAR-001: SAR Test Report RevA Test Report S/N: 2025.044.01 Page 3 of 15 1. DUT Specifics 1.1. Device under Test The device under test is a wireless device, incorporating the technologies listed in Table 1-1 below. The manufacturer has confirmed that the device is within operational tolerances expected for production units and has the same physical, mechanical, and thermal characteristics expected for production units. The serial number of the device used for each test is indicated alongside the results. Table 1-1 Supported Technologies 1.2. Maximum Time-Averaged Power From Manufacturer The manufacturer has confirmed that this device follows the below target output power specifications and tolerances. SAR values were scaled to the maximum allowed power (including tolerance) to determine compliance per KDB Publication 447498 D04v01. Table 1-2 RFID 920 MHz Target RF Output Power Table 1-3 2.4 GHz Bluetooth LE Target RF Output Power Band/ModeFrequency (MHz) RFID 920 MHz917.1 - 926.9 MHz 2.4 GHz Bluetooth LE2402 - 2480 MHz RFID 920 MHz Maximum Power [dBm] Power LevelChannel920 MHz Antenna All19 Upper Tolerance: +0 dB Max 2.4 GHz Bluetooth Maximum Power [dBm] Power Level Mode Data Rate MDBT42Q-P Antenna BLE1Mbps4.5 BLE2Mbps4.5 Upper Tolerance: +0 dB Max Next Generation Test Laboratory Inc. (RF Safety Laboratory, LLC) 5520 Research Park Drive, Suite 140, Catonsville, Maryland 21228 USA ISED Lab Code: 32002; FCC Designation Number: US3274 ANAB 17025 Certificate Number: AT-3274; CAB Identifier: US0239 ☎+1 202 240 9240; ο“§ο“§[email protected] FCC ID: 2BEXRRHM920T002 IC: 32014-RHM920T002 SAR-001: SAR Test Report RevA Test Report S/N: 2025.044.01 Page 4 of 15 1.3. Test Guidance Applied β€’ IEEE 1528-2013 (FCC) β€’ IEC/IEEE 62209-1528:2020 (ISED) β€’ RSS-102 Issue 6 (ISED) β€’ RSS-102.SAR.MEAS (ISED) β€’ Health Canada Safety Code 6 (ISED) β€’ F…

Text truncated - open the document above for the full version.

RF Exposure Info

FCC ID: 2BEXRRHM920T002 IC: 32014-RHM920T002 SAR-001: SAR Test Report RevA Test Report S/N: 2025.044.01 Page A1 of A1 Appendix A: SAR Test Plots RF SAFETY LABORATORY DUT: M920SRW-B, Bare Module; SN: 901015R Test Conditions Exposure Condition Position, Test Distance [mm] Band Signal, UID Ant. Channel Number Frequency [MHz] ConvF (x,y,z) Body/Extremity Flat, FRONT, 0.00 RFID 920 MHz CW, 0 920 MHz Antenna 1 917.100 9.05, 9.79,8.99 Test Setup Test Date Ambient Temp [Β°C] TSL Temp [Β°C] Measurement SW Phantom Type Cond. [S/m] TSL Perm. Probe, Cal. Date DAE, Cal. Date 2025-11-13 21.9 21 16.4.0.5005 Twin-SAM V8.0 - 2165 Head Simulating Liquid 0.935 45.3 EX3DV4 - SN7872, 2025-08-08 DAE4ip Sn1843, 2025-07-30 Scans Setup Area Scan Zoom Scan Grid Extents [mm] 90.0 x 90.0 38.4 x 38.4 x 31.2 Grid Steps [mm] 15.0 x 15.0 4.8 x 4.8 x 1.5 Sensor Surface [mm] 3.0 1.4 Grading Ratio N/A 1.5 MAIA Y Y Measurement Results psSAR1g [W/Kg] 0.624 psSAR10g [W/Kg] 0.239 Power Drift [dB] 0.01 Peak SAR (Extrapolated) [W/kg] 2.00 M2/M1 [%] 60.3 Dist 3dB Peak [mm] 6.1

RF Exposure Info

FCC ID: 2BEXRRHM920T002 IC: 32014-RHM920T002 SAR-001: SAR Test Report RevA Test Report S/N: 2025.044.01 Page B1 of B3 Appendix B: Tissue Stimulating Liquids, System Checks and System Validation B.1. SAR System Check Prior to SAR assessment, the system is verified to Β±10% of the SAR measurement on the reference dipole at the time of calibration by the calibration facility. SAR System Validation was performed and complies with requirements per IEC/IEEE 62209-1528. Table 1 System Check Results (SAR) B.2. Dielectric Parameters of the TSL Table 2 SAR Tissue Dielectric Parameters The above measured tissue parameters were used in the DASY software. The DASY software was used to perform interpolation to determine the dielectric parameters at the SAR test device frequencies (per KDB Publication 865664 D01v01r04 and IEEE 1528-2013 6.6.1.2). The tissue parameters listed in the SAR test plots may slightly differ from the table above due to significant digit rounding in the software. The SAR values were compensated for deviations between the measured and required tissue dielectric properties, as described in IEEE 1528-2013. The SAR values were applied to only scale up the measured SAR values, and not downward, per KDB Publication 865664 D01v04r04. System Frequency (MHz) Tissue Type Date Amb. Temp. (Β°C) Tissue Temp (Β°C) Input Power (dBm) Verification Source SN Probe SN DAE SN Measured 1g SAR (W/Kg) 1W Target 1g SAR (W/Kg) 1W Normalized 1g SAR (W/Kg) 1g SAR Deviation Measure d 10g SAR (W/Kg) 1W Target 10g SAR (W/Kg) 1W Normalized 10g SAR (W/Kg) 10g SAR Deviation Gamma835Head11/13/202521.921.0174d311787218430.5099.82010.1563.42%0.3366.3706.7045.24% Date Tissue Type Liquid Temp (Β°C)Frequency (MHz) Conductivity Measured (Οƒ) Conductivity Target (Οƒ) Deviation Permittivity measured (Ξ΅r) Permittivity Target (Ξ΅r) Deviation 11/13/2025Head21 8000.890.90 -1.09%45.641.79.44% 11/13/2025Head 218500.91 0.92-1.11%45.5 41.59.60% 11/13/2025Head21 9000.930.97 -4.22%45.341.5 9.14% 11/13/2025Head21 9500.950.99 -4.79%45.241.4 9.03% FCC ID: 2BEXRRHM920T002 IC: 32014-RHM920T002 SAR-001: SAR Test Report RevA Test Report S/N: 2025.044.01 Page B2 of B3 B.3. FCC System Validation Per FCC KDB Publication 865664 D02 Section 2.3 a) states β€œSAR system validation status and system verification results should be documented in a separate section of the SAR report, or as an attachment, to confirm measurement accuracy.” The SAR systems used for evaluating this device were validated against its performance specifications prior to the SAR measurements. Reference dipoles were used with the required tissue-equivalent media for system validation, according to the procedures outlined in FCC KDB Publication 865664 D01 and IEEE 1528-2013. Since SAR probe calibrations are frequency dependent, each probe calibration point was validated at a frequency within the valid frequency range of the probe calibration point. Per FCC KDB 865664 D02, β€œthe validation status should be documented according to the validation date(s), measurement frequencies, SAR probes, calibrated signal type(s) and tissue dielectric parameters.” A tabulated summary of the system validation status is provided accordingly: Table 3 System Validation NOTE: The probes have been calibrated for both CW and modulated signals. Modulations in the table above represent test configurations for which the measurement system has been validated per FCC KDB Publication 865664 D01 for scenarios when CW probe calibrations are used with other signal types. SAR systems were additionally validated for modulated signals with a periodic duty cycle or with a high PAR (peak to average ratio) >5 dB, such as OFDM according to FCC KDB Publication 865664 D01 v01r04. Freq (MHz) Tissue Type Sensitivity Probe Linearity Probe Isotropy Mod Type Duty Factor PAR Gamma83508/27/202578721843835Head0.9341.9PASSPASSPASSGMSKPASSN/A Cond. ( Οƒ) Perm ( Ξ΅r) CW ValidationMod Validation System Frequency (MHz) DateProbeDAE Probe CalF FCC ID: 2BEXRRHM920T002 IC: 32014-RHM920T002 SAR-001: SAR Test Report RevA Test Report S/N: 2025.044.01 Page B3 of B3 B.4. Sample TSL Compositions TSL recipes are proprietary to SPEAG. Since the composition is approximate to the actual liquids utilized, the manufacturer data sheets are provided below. Figure 1 - Head TSL Calibration Certificate Example (600 – 10000 MHz)

RF Exposure Info

FCC ID: 2BEXRRHM920T002 IC: 32014-RHM920T002 SAR-001: SAR Test Report RevA Test Report S/N: 2025.044.01 Page C1 of C1 Appendix C: System Check Plots RF SAFETY LABORATORY System Verification Verification Conditions Verification Source Power [dBm] Phantom Section Test Distance [mm] Signal, UID Frequency [MHz] ConvF (x, y, z) D835V2 - SN4d311 17.0 Flat 15 CW, 0 835.000 9.05, 9.79,8.99 Test Setup Test Date Ambient Temp [Β°C] TSL Temp [Β°C] Measurement SW Phantom TSL Type Cond. [S/m] Perm. Probe, Cal. Date DAE, Cal. Date 2025-11-13 21.9 21 16.4.0.5005 Twin-SAM V8.0 - 2165 Head Simulating Liquid 0.900 45.5 EX3DV4 - SN7872, 2025-08-08 DAE4ip Sn1843, 2025-07-30 Scans Setup Area Scan Zoom Scan Grid Extents [mm] 40.0 x 90.0 30.0 x 42.0 x 31.2 Grid Steps [mm] 10.0 x 15.0 6.0 x 6.0 x 1.5 Sensor Surface [mm] 3.0 1.4 Grading Ratio N/A 1.5 Measurement Results SAR [W/kg] or APD [W/mΒ²] Deviation [%] psSAR1g 0.509 3.42 psSAR10g 0.336 5.24 Peak SAR (Extrapolated) 0.758 7.26 psAPD (4.0 cmΒ², sq) N/A N/A

RF Exposure Info

RF Safety Laboratory, LLC 5520 Research Park Drive, Suite 140 Catonsville, Maryland 21228 USA +1 202 240 9240 [email protected] Object: Date Issued: D835V2 – SN: 4d311 11/8/2024 Page 1 of 3 IN-HOUSE SAR VERIFICATION SOURCE CALIBRATION EXTENSION Object D835V2 – SN: 4d311 Description SAR Validation Dipole at 835 MHz Procedure (s) Procedure for SAR Verification Source Calibration Extension In-house Check Date 11/7/2024 E quipment List CBT: Components calibrated before testing. Prior to testing, the measurement paths containing a cable, attenuator, coupler or filter were connected to a calibrated source (i.e. a signal generator, power sensor, or VNA) to determine the losses of the measurement path. The power meter offset was then adjusted to compensate for the measurement system losses. This level offset is stored within the power meter before measurements are made. This calibration verification procedure applies to the system verification and output power measurements. The calibrated reading is then taken directly from the power meter after compensation of the losses for all final power measurements. Measurement Uncertainty = Β±27% (k=2) Name Function Signature Tested By: Yue LiEngineer Approved By: Phuong Nguyen Technical Manager ManufacturerModelDescriptionSerial Number Calibration Date Calibration Due CBT Rohde & SchwarzZNL20Vector Network Analyzer1012029/12/20249/12/2025 Rohde & SchwarzZN-Z135Calibration Kit5000-30919283910/31/2410/31/26 Control Company4040Ambient Thermometer2305816578/28/20238/28/2025 Control Company4352Long Stem Liquid Thermometer2306622239/28/20239/28/2025 Micro-CoaxUFB205A-0-0240-30x30SMA M-F RF test Cable (DC - 18 GHz)-βœ“ Mini-CircuitsBW-N20W20+20dB RF Fixed Attenuator (DC - 18 GHz)-βœ“ Mini-CircuitsNF-SF50+RF Adapter N Male to SMA Female (DC - 18 GHz)-βœ“ SPEAGDAE4ipData Acquisition Electrionics with Integ. Power18398/14/20248/14/2025 SPEAGDAK-3.5DAK-3.5 Dielectric Probe13499/2/20249/2/2025 SPEAGEX3DV4SAR Measurement Probe78363/15/20243/15/2025 SPEAGPowersource1Signal Generator43411/5/20241/5/2025 RF Safety Laboratory, LLC 5520 Research Park Drive, Suite 140 Catonsville, Maryland 21228 USA +1 202 240 9240 [email protected] Object: Date Issued: D835V2 – SN: 4d311 11/8/2024 Page 2 of 3 Per FCC KDB Publication 865664 D01, dipole can have longer calibration intervals of up to three years when it is demonstrated that the SAR target, impedance and return loss of the dipole have remained stable according to the following requirements: 1. Measured SAR does not deviate from the calibrated SAR value by more than 10%. 2. Return loss does not deviate by more than 20% from the previous measurement (i.e. value in dB x 0.2) and meet the required minimum return-loss. 3. Real and imaginary part of the impedance do not deviate by more than 5 Ω from the previous measurement. The following dipole was checked to pass the above 3 requirements to have an extended calibration interval: Dipole SN Freq (MHz) In-house Check Date Cal Date Head SAR target (1g) @ 30dBm (W/kg) Measured Head SAR (1g) @ 17dBm (W/kg) 1g SAR Deviation (%) Head SAR target (10g) @ 30dBm (W/kg) Measured Head SAR (10g) @ 17dBm (W/kg) 10g SAR Deviation (%) Cert Head Impedance (Ohm) - Real Measured Head Impedance (Ohm) - Real Head Impedance Deviation (Ohm) - Real Cert Head Impedance (Ohm) - Imaginary Measured Head Impedance (Ohm) - Imaginary Head Impedance Deviation (Ohm) - Imaginary Cert Head Return Loss (dB) Measured Head Return Loss (dB) Return Loss Deviation (%) PASS/FAIL 4d31183511/7/202410/9/20239.820.537.48%6.370.358.06%49.949.4-0.5-2.4-2.00.4-32.5-33.4-18.68%PASS RF Safety Laboratory, LLC 5520 Research Park Drive, Suite 140 Catonsville, Maryland 21228 USA +1 202 240 9240 [email protected] Object: Date Issued: D835V2 – SN: 4d311 11/8/2024 Page 3 of 3 Impedance and Return-Loss Measurement Plot for Head TSL RF Safety Laboratory, LLC 5520 Research Park Drive, Suite 140 Catonsville, Maryland 21228 USA +1 202 240 9240 [email protected] Object: Date Issued: D835V2 – SN: 4d311 07/29/2025 Page 1 of 3 IN-HOUSE SAR VERIFICATION SOURCE CALIBRATION EXTENSION Object D835V2 – SN: 4d311 Description SAR Validation Dipole at 835 MHz Procedure (s) Procedure for SAR Verification Source Calibration Extension In-house Check Date 07/29/2025 Equipment List CBT: Components calibrated before testing. Prior to testing, the measurement paths containing a cable, attenuator, coupler or filter were connected to a calibrated source (i.e. a signal generator, power sensor, or VNA) to determine the losses of the measurement path. The power meter offset was then adjusted to compensate for the measurement system losses. This level offset is stored within the power meter before measurements are made. This calibration verification procedure applies to the system verification and output power measurements. The calibrated reading is then taken directly from the power meter after compensation of the losses for all final power measurements. Measurement Uncertainty = Β±27% (k=2) Name Function Signature Tested By: YL Engineer Approved By: PN Technical Manager ManufacturerModelDescriptionSerial Number Calibration Date Calibration Due CBT Rohde & SchwarzZNL20Vector Network Analyzer1012029/12/20249/12/2025 Rohde & SchwarzZN-Z135Calibration Kit5000-30919283910/31/2410/31/26 Control Company4040Ambient Thermometer2305816578/28/20238/28/2025 Control Company4040Ambient Thermometer2305816628/28/20238/28/2025 Control Company4352Long Stem Liquid Thermometer2306622239/28/20239/28/2025 Control Company4352Long Stem Liquid Thermometer2306622129/28/20239/28/2025 Micro-CoaxUFB205A-0-0240-30x30SMA M-F RF test Cable (DC - 18 GHz)-βœ“ Maury-Micro360D10dB RF Fixed Attenuator (DC - 18 GHz) + Short Circuit Termination779912/28/202412/28/2025 Huber+SuhnerSF126High Performance RF Cable570292/126βœ“ SPEAGDAE4ipData Acquisition Electrionics with Integ. Power18399/4/20249/4/2025 SPEAGDAK-3.5DAK-3.5 Dielectric Probe13499/2/20249/2/2025 SPEAGEX3DV4SAR Measurement Probe78369/12/20249/12…

Text truncated - open the document above for the full version.

RF Exposure Info

FCC ID: 2BEXRRHM920T002 IC: 32014-RHM920T002 SAR-001: SAR Test Report RevA Test Report SN: 2025.044.01 Page E1 of E3 Appendix E: Simultaneous Transmission Analysis E.1. Introduction According to FCC KDB Publication 447498 D04v01, transmitters are considered to be operating simultaneously when there is overlapping transmission, with the exception of transmissions during network hand-offs with maximum hand-off duration less than 30 seconds. Table E-1 - Supported Simultaneous Transmission Scenarios E.2. Procedures This device contains transmitters that may operate simultaneously. Therefore, simultaneous transmission analysis is required. Per FCC KDB Publication 447498 D04v01, IEEE 1528-2013 Section 6.3.4.1.2 and IEC/IEEE 62209-1528 Section 7.4.4, simultaneous transmission SAR test exclusion may be applied when the sum of the 1g/10g SAR for all the simultaneous transmitting antennas in a specific physical test configuration is ≀1.6 W/kg for 1g SAR or ≀4.0 W/kg for 10g SAR. The different test positions in an exposure condition may be considered collectively to determine SAR test exclusion according to the sum of 1g or 10g SAR. E.3. Bluetooth LE Estimated SAR E.3.1 FCC Estimated SAR Per FCC KDB 447498 D01 v06 Section 4.3.2, when an antenna qualifies for the standalone SAR test exemption and also transmits simultaneously with other antennas, the standalone SAR value must be estimated according to the following to determine the simultaneous transmission SAR test exclusion criteria: ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ 퐷퐷퐷퐷퐷퐷퐷퐷 푀푀퐷퐷퐷퐷 ν‘€ν‘€ βˆ™ οΏ½ ν‘“ν‘“ 퐺퐺퐺퐺퐺퐺 7.5 (for 1-g SAR) ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ 퐷퐷퐷퐷퐷퐷퐷퐷 푀푀퐷퐷퐷퐷푀푀 βˆ™ οΏ½ ν‘“ν‘“ 퐺퐺퐺퐺퐺퐺 18.75 (for 10-g SAR) Where: ν‘“ν‘“ 퐺퐺퐺퐺퐺퐺 = RF Channel frequency in GHz MaxPower = Power of channel, including tune-up tolerance, rounded to the nearest mW before calculation Distance = Min. Test Separation Distance in mm, rounded to the nearest mm before calculation Per FCC KDB 447498 D01 v06 Section 4.3.1, β€œPower and distance are rounded to the nearest mW and mm before calculation.” The result is rounded to one decimal place for comparison. For Bluetooth LE, 4.5 dBm = 3 mW For distances ≀ 5mm, per FCC policy the value of 5 shall be used for the distance component of the equation. #Scenario Body Extremity 1 RFID 920 MHz + 2.4 GHz Bluetooth LEYes Yes FCC ID: 2BEXRRHM920T002 IC: 32014-RHM920T002 SAR-001: SAR Test Report RevA Test Report SN: 2025.044.01 Page E2 of E3 ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ 퐷퐷퐷퐷퐷퐷퐷퐷 푀푀퐷퐷퐷퐷 ν‘€ν‘€ βˆ™ οΏ½ ν‘“ν‘“ 퐺퐺퐺퐺퐺퐺 7.5 = 3 5 βˆ™ √ 2.48 7.5 = 0.13 W/kg (for 1-g SAR) ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ 퐷퐷퐷퐷퐷퐷퐷퐷 푀푀퐷퐷퐷퐷 ν‘€ν‘€ βˆ™ οΏ½ ν‘“ν‘“ 퐺퐺퐺퐺퐺퐺 18.75 = 3 5 βˆ™ √ 2.48 18.75 = 0.05 W/kg (for 10-g SAR) Bluetooth LE Estimated SAR is 0.13 W/kg for 1-g SAR and 0.05 W/kg for 10-g SAR. E.3.2 ISED Estimated SAR Per RSS-102 Section 7.1.8, an estimated SAR value based on the ratio of the power level and the power exemption limit may be used to determine the standalone SAR value for test configurations that do not require a SAR evaluation based on test reductions. The estimated SAR value is calculated using equation below: ν‘€ν‘€ ν‘šν‘šν‘šν‘šν‘šν‘š ν‘€ν‘€ ν‘šν‘šν‘šν‘šν‘šν‘š,ν‘’ν‘’ν‘šν‘šν‘’ν‘’ ν‘šν‘šν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ βˆ™0. 25 .푆푆푆푆푆푆 푙푙퐷퐷푙푙퐷퐷퐷퐷 Where: 푃푃 ν‘™ν‘™ν‘€ν‘€ν‘€ν‘€ = maximum power level, including tune-up tolerance, in mW 푃푃 ν‘™ν‘™ν‘€ν‘€ν‘€ν‘€,ν‘€ν‘€ν‘€ν‘€ν‘€ν‘€ν‘™ν‘™ν‘’ν‘’ 퐷퐷퐷퐷푀푀퐷퐷 = maximum power level of exemption, in mW 푆푆푆푆푆푆 푙푙퐷퐷푙푙퐷퐷퐷퐷 = applicable SAR limit for 1-g and 10-g SAR, in W/kg For Bluetooth LE, 4.5 dBm = 3 mW Per RSS-102 Section 6.3, the maximum power level of exemption at frequency 2450 MHz and distance ≀ 5mm is 3.0 mW for 1-g SAR and 7.5 mW for 10-g SAR. ν‘€ν‘€ ν‘šν‘šν‘šν‘šν‘šν‘š ν‘€ν‘€ ν‘šν‘šν‘šν‘šν‘šν‘š,ν‘’ν‘’ν‘šν‘š ν‘’ν‘’ν‘šν‘š ν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ βˆ™0.25 .푆푆푆푆푆푆 푙푙퐷퐷푙푙퐷퐷퐷퐷 = 3 3 x 0.25 x 1.6 = 0.40 W/kg (for 1-g SAR) ν‘€ν‘€ ν‘šν‘šν‘šν‘šν‘šν‘š ν‘€ν‘€ ν‘šν‘šν‘šν‘šν‘šν‘š,ν‘’ν‘’ν‘šν‘š ν‘’ν‘’ν‘šν‘š ν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ν‘’ βˆ™0.25 .푆푆푆푆푆푆 푙푙퐷퐷푙푙퐷퐷퐷퐷 = 3 7.5 x 0.25 x 4.0 = 0.40 W/kg (for 10-g SAR) Bluetooth LE Estimated SAR is 0.40 W/kg for 1-g SAR and 10-g SAR. FCC ID: 2BEXRRHM920T002 IC: 32014-RHM920T002 SAR-001: SAR Test Report RevA Test Report SN: 2025.044.01 Page E3 of E3 E.4. Simultaneous Transmission Analysis Table E-2 – FCC Simultaneous Transmission Analysis Table E-3 – ISED Simultaneous Transmission Analysis The above analysis of the simultaneous transmission scenarios is sufficient to show that sim…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yoshiaki Hirano
[email protected]Fax: +81-3-6402-7070

Technical Contact

TEIJIN FRONTIER (U.S.A.), INC. .Yuki Kuwabara
[email protected]

1412 Broadway Suite 1500 Β· New York, 10018 Β· United States

Test Firm

RF Safety Laboratory, LLCSteve Liu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.80 mW
Confidentiality
Long Term
Grant Notes
Output power is peak conducted. Accessories are restricted to those evaluated in this filing or similar accessories that have no metallic components.