ARW-CX-033 Name Output Material USB-C 2:This product has an input overcurrent and overvoltage protect ion function,lf it is usedimproperly it willshut down or reduce the output power,plea se check whether the device is abnormal or used improperly3:Keep the ambient temperature at 0-25°C, Do not put the product in water,fire,high temperature(>40°C<) or low temperature(>20<)environment,keep it away from children. 4:Please use a dry soft cloth to clean the surface, do not use chemicals, soap or detergent to clean.5:Improper use or improper placement may reduce the life of the product or damage it, which is not covered by the warranty. Application scenarios: When charging, the center of the watch should be aligned with t he center of the charging position, then it can be charged wirelessly. If the watch can not be charged normally, adjust th e position of the watch until the watch can be charged φ60x7.8mm 5V/2A 9V/2A Charging port Cellulose acetate Tips: 1:Recmmended:PD20W or above power adapter(sold separately) Product parameters Product analysis Wireless Charger formobile phone (headset) 5W 7.5W 10W 15W(MAX) Product dimensions Input This device complies with Part 15 of the FCC Rules. Operation i s subject to the following two conditions: (1) this device may not cause harmful interference, and(2) this device must accept any interference received, includin g interference that may cause undesired operation This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC R ules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmfu l interference to radio or television reception, which can be determined by turning the device off an d on, the user is encouraged to try to correct the interference by one or more of the following measures:--Reorient or relocate the receiving antenna.--Increase the separation between the device and receiver.--Connect the device into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help Changes or modifications not expressly approved by the party re sponsible for compliance could void the user's authority to ope rate the equipment The distance between user and products should be no less 20cm
Shenzhen Anruiwei Electronic Technology Co., Ltd. Covered Equipment Certification Attestation Letter 4/29/2024 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2BF2P-ARW01 Shenzhen Anruiwei Electronic Technology Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Shenzhen Anruiwei Electronic Technology Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. <Signature>: Name:YouShengTu Title:Manager Applicant Company:Shenzhen Anruiwei Electronic Technology Co., Ltd. Date: 4/29/2024
April 29, 2024 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen Timeway Testing Laboratories/ Zone C, 1st Floor, Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Shenzhen Anruiwei Electronic Technology Co., Ltd. / Building 10, Shanmen Second Industrial Zone, Yanluo Street, Baoan District, Shenzhen <Signature>: Name:YouShengTu Title:Manager Applicant Company:Shenzhen Anruiwei Electronic Technology Co., Ltd.
April 29, 2024 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2BF2P-ARW01 Product Name: Wireless Charging Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name:YouShengTu Title:Manager Applicant Company:Shenzhen Anruiwei Electronic Technology Co., Ltd.
Label Location
Report No.: TW2403063-H Page 1 of 5 Date: 2024-03-13 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES.It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES.reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. FCC ID: 2BF2P-ARW01 RF Exposure Evaluation 1 Requirement §1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in §1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of FCC part 2.1091 of this chapter. Table 1 to §1.1310(e)(1) - Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (i) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *(100) ≤6 3.0-30 1842/f 4.89/f *(900/f 2 ) <6 30-300 61.4 0.163 1.0 <6 300-1500 f/300 <6 1500-100000 5 <6 (ii) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *(100) <30 1.34-30 824/f 2.19/f *(180/f 2 ) <30 30-300 27.5 0.073 0.2 <30 300-1500 f/1500 <30 1500-100000 1.0 <30 f = frequency in MHz * = Plane-wave equivalent power density Note 1: Occupational/controlled exposure limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Note 2: General population/uncontrolled exposure limits apply in situations in which the general public may be exposed, or in which persons who are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. Report No.: TW2403063-H Page 2 of 5 Date: 2024-03-13 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES.It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES.reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. 2 Test setup Z axis Rear 20 cm 20 cm Left 20 cm EUT 20 cm Right M-0812 Probe 20 cm Front 20 cm Bottom 3 Test Procedures a. The RF exposure test was performed in anechoic chamber. b. E and H-field measurements should be made with these devices considered to meet the § 2.1091-Mobile conditions (“generally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between the RF source's radiating structure(s) and [the nearest person]”). c. The highest emission level was recorded and compared with limit. d. The EUT was measured according to the dictates of KDB 680106 D01 Wireless Power Transfer v04. Report No.: TW2403063-H Page 3 of 5 Date: 2024-03-13 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES.It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES.reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. 4 Equipment Approval Considerations Requirement Device 1. The power transfer frequency is below 1 MHz Yes. The operating frequencies are: 111.5 kHz – 205 kHz 2. The output power from each transmitting element (e.g., coil) is less than or equal to 15 watts. Yes. The maximum output power is: 15W 3.A client device providing the maximum permitted load is placed in physical contact with the transmitter (i.e., the surfaces of the transmitter and client device enclosures need to be in physical contact) Yes. The client device is placed directly in contact with the transmitter. 4. Only § 2.1091-Mobile exposure conditions apply (i.e., this provision does not cover §2.1093-Portable exposure conditions). Yes. Mobile exposure conditions only. 5. The E-field and H-field strengths, at and beyond 20 cm surrounding the device surface, are demonstrated to be less than 50% of the applicable MPE limit, per KDB 447498, Table 1. These measurements shall be taken along the pri…
Text truncated - open the document above for the full version.
Report No.: TW2403063E Applicant: Shenzhen Anruiwei Electronic Technology Co., Ltd. Product: Wireless Charging Model No.: ARW-CX-033, ARW-CX-004, ARW-CX-017 Trademark: N/A Test Standards: FCC Part 15 Subpart C Test Result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4&FCC Part 15 Subpart C, for the evaluation of electromagnetic compatibility Approved By Terry Tang Manager Dated: March 13, 2024 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No: TW2403063E Page 2 of 29 Date: 2024-03-13 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. Industry Canada (IC) —Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 CAB identifier: CN0033 Report No: TW2403063E Page 3 of 29 Date: 2024-03-13 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details............................................................................................... 4 1.3 Description of EUT ........................................................................................... 4 1.4 Submitted Sample.............................................................................................. 5 1.5 Test Duration.................................................................................................... 5 1.6 Test Uncertainty................................................................................................. 5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details............................................................................................. 7 3.1 Summary of Test Results..................................................................................... 7 3.2 Test Standards.................................................................................................. 7 4.0 EUT Modification............................................................................................ 7 5.0 Power Line Conducted Emission Test................................................................... 8 5.1 Schematics of the Test........................................................................................ 8 5.2 Test Method and Test Procedure............................................................................ 8 5.3 Configuration of the EUT.................................................................................... 8 5.4 EUT Operating Condition.................................................................................... 9 5.5 Conducted Emission Limit................................................................................... 9 5.6 Test Result...................................................................................................... 9 6.0 Radiated Emission test...................................................................................... 12 6.1 Test Method and Test Procedure............................................................................ 12 6.2 Configuration of the EUT.…
Text truncated - open the document above for the full version.
Page 1 of 3 SPECIFICATION FOR APPROVAL 客户: CUSTOMER:Anrui micro 客户料号: CUS T P /N : 天夏料号: TX P /N : 产品型号: DESC: 日期 DATE : 版本: Version : T X - D 4 2 . 8 * 5 . 3 * 0 . 6 - 6 . 5 U H 2 0 . 5 * 3 9 . 5 - 0 . 0 8 * 4 8 P - 1 0 T S - 1 8 m m - D 4 2 . 8 * 5 . 3 * 0 . 6 D o u b l e s l o t o u t l e t w i t h b a c k i n g t a p e - 6 . 5 u h 2 0 2 4 / 0 3 / 0 7 A . 0 拟制 P R EPARED BY 审核 CHECKED B Y 批准 APP ROVED BY 客户承认 CUSTOMER AP PROVE L u o X i o n g b i n Y a n Z h a n g L u o Y o n g j u n 地址: Room 523-525, C 33 Science and Technology Innovation Park, District 33, Bao'an District, Shenzhen City 电话:18718699959 Page 2 of 3 Version Ch ange History 版本 Rev . 变更前 Before Change 变更后 After Change 更改日期 Change Dat e 批准 A pproved By A.0new issue ---- 2024/03/07 Luo Yongjun Page3of3 产品型 号: D E SC 20.5*39.5-0.08 * 48P-10TS-18mm- D 4 2 . 8 * 5 . 3 * 0 . 6 D o u b l e c h a n n e l o u t l e t t a p e b a c k g l u e - 6 . 5 u h R e v : A . 0 客户CUST: Customer material number CUST P / N: 1 . D i m e n s i o n D I M E N S I O N : ( m m ) 2 . S c h ema t i c d i a g r a m of t h e S C H E M A TIC D I A G R A M AThe inner hole of the magnetic plate 5 . 3 ± 0 . 3 m m B c o i l i n n e r d i a m e t e r 2 0 . 5 ± 0 . 5 m m C T h e c o i l e d - c o i l oute r d i a m et e r 3 7 . 5 ± 1 m m D M a g n e t i c s h e e t o u t e r d i a m e t e r 4 2 . 5 ± 0 . 5 m m E l e n g t h o f l e a d 1 8 ± 2 m m T h e l e n g t h o f t h e F dip t i n 5mmMAX T-sheet t h i c k n e s s 0 .6± 0 . 1 m m H a g g r e g a t e t h i c k n e s s 1 . 6 m m M A X (e x c l u d i n g l ead l i n e s ) N o t e : 1 . Coi ls c r o s s o u t o f t h e l ine , d o n o t l o o s en t he l i n e . 2 S t i c k wi t h a D 4 2 . 8 * 5 . 3 * 0 . 6 m m f e r r i t e h a r d m a g n e t i c s h e e t 3 . O v e r a l l t h i c k n e s s o f t h e c o i l D e g r ee 1 . 6 m mM A X ( w it ho u t t h e lead); 5. Ring the white t r a n s p a r e n t i n s u l a t i n g rubber around the outlet end 3. Winding parameter Winding Specification: Page 3 of 3 序号 NO . 端子 TERMINA L 线径 WI RE 圈数 T u rns 绕线方向 Winding Direc tion 1 S F 0.08*24PX2 10Ts anticlockwise m e a s u r i n g a n d t e s t instruments TEST EQUIP MENTS 4.ElectricalcharacteristicsELECTRICALCHARACTERISTICS: TemperatureTEMPERATURE:25±10°C,humidityRELATIVEHUMIDITY:65± 20% orde r n u m b e r NO. The P r o j e c t I T E M Terminal, T E R M I N A L s t a n d a r d SPECIFICATIO N test condition TEST FREQU E N C Y 1I N D . S - F 4 . 0 u H ± 2 0 % , i n d i v i d u a l c o i l 1 0 0 K H z / 1 . 0 V L C Z M E T E R 1 0 6 2 B 2 I N D . S - F 6.5 uH ± 10% tape m a g n e t i c c h i p 1 0 0 K H z / 1 . 0 V L C Z M E T E R 1 0 6 2 B 拟制/日期PREPARED BY / DATE审核/日期CHECKED BYDATE Luo Xiongbin 2024 / 03 / 07 Zhang Yan 2024 / 03 / 07
Conducted Emission Test Setup: Radiated Emission Test Setup:
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1115 MHz - 0.205 MHz | - |

Wireless Charging
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz