FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Carl Zeiss Meditec AG/
  3. 2BF3L304972-8200

2BF3L304972-8200Bluetooth Gateway

Carl Zeiss Meditec AG
Bluetooth Gateway - FCC ID 2BF3L304972-8200 - Carl Zeiss Meditec AG
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jun 25, 2024
Application Purpose
Original Equipment
Date of Application
Jun 25, 2024
Equipment Note
Bluetooth Gateway
Frequency Range
2402.00000000 - 2480.00000000
Company
Carl Zeiss Meditec AG
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗
↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCP Gateway WL 2 Instructions for Use Copyright © 2024, Carl Zeiss Meditec AG, Jena FCP Gateway WL 2 is a trademark or registered trademark of Carl Zeiss Meditec AG or other companies of the ZEISS Group in Germany and/or other countries. All other trademarks in this document are property of their respective owners. Instructions for UseTable of Contents FCP Gateway WL 2 G-30-2285-en - 1.1 - 2024-06-133 / 28 Table of Contents 1Notes on the instructions for use..............................................................5 1.1System name...................................................................................................................5 1.2Scope of application........................................................................................................5 1.3Purpose and storage of the documentation....................................................................5 1.4Questions and comments................................................................................................5 1.5Conventions in this document.........................................................................................5 1.5.1Conventions in all text areas........................................................................................................6 1.5.2Conventions in a course of action................................................................................................6 2Safety notes..............................................................................................7 2.1Area of use......................................................................................................................7 2.1.1Intended use...............................................................................................................................7 2.1.2Normal use..................................................................................................................................7 2.1.3Discipline.....................................................................................................................................7 2.2Responsibilities and duties of the operator.....................................................................7 2.2.1Messages to manufacturer and authorities..................................................................................9 2.3Measures and duties of the operator...............................................................................9 3Description of the system..........................................................................11 3.1System markings.............................................................................................................11 3.1.1Labeling on the FCP Gateway......................................................................................................11 3.2Structure of the system...................................................................................................11 3.2.1Control elements.........................................................................................................................11 3.2.2Connection panel........................................................................................................................12 3.3Functional description.....................................................................................................12 3.3.1FCP Gateway functions................................................................................................................12 4Cleaning and disinfection..........................................................................13 5Troubleshooting........................................................................................15 5.1Resetting the FCP Gateway.............................................................................................15 5.2Service information.........................................................................................................15 6Technical specifications.............................................................................17 6.1Essential performance features.......................................................................................17 6.2Regulatory information...................................................................................................17 6.2.1Canada / USA - IC warnings RSS-Gen & RSS-247 statement.........................................................17 Table of ContentsInstructions for Use FCP Gateway WL 2 4 / 28G-30-2285-en - 1.1 - 2024-06-13 6.3Technical data.................................................................................................................18 6.3.1Electrical data..............................................................................................................................18 6.3.2Dimensions and weight...............................................................................................................18 6.3.3Ambient requirements for operation...........................................................................................19 6.3.4Ambient requirements for transport and storage.........................................................................19 7Accessories and components....................................................................21 7.1FCP Gateway...................................................................................................................21 8Disposal....................................................................................................23 8.1Safety during disposal.....................................................................................................23 8.2Disposal of the system.....................................................................................................23 Glossary....................................................................................................25 Index...........................................…

Text truncated - open the document above for the full version.

Attestation Statements

Carl Zeiss Meditec AG Goeschwitzer Strasse 51-52 07745 Jena/Germany Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA 12-June-2024 Attestation Statement according to 2.911(d)(5)(i) and 2.911(d)(5)(ii) FCC ID: 2BF3L304972-8200 TO WHOM IT MAY CONCERN: Hereby we certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Further we certify that, as of the date of the filing of the application, Carl Zeiss Meditec AG is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, _______________ (signature & company stamp) Carl Zeiss Meditec AG 0017809617 Goeschwitzer Strasse 51-52 07745 Jena/GERMANY Josef Schlosser +497364202957 [email protected]

Attestation Statements

Carl Zeiss Meditec AG Goeschwitzer Strasse 51-52 07745 Jena/Germany Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA 12-June-2024 Attestation Statement according to 2.911(d)(7) FCC ID: 2BF3L304972-8200 TO WHOM IT MAY CONCERN: We, Carl Zeiss Meditec AG designate Carl Zeiss Meditec USA, Inc. to act as U.S. agent for service of process. Carl Zeiss Meditec USA, Inc. hereby acknowledges the obligation of the U.S. agent for service of process. Further Carl Zeiss Meditec AG accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Additionally, Carl Zeiss Meditec USA, Inc. has no direct business with the FCC and therefore has no assigned FRN. Sincerely _______________ (signature & company stamp) Carl Zeiss Meditec AG 0017809617 Goeschwitzer Strasse 51-52 07745 Jena/GERMANY Josef Schlosser +497364202957 [email protected] _______________ (signature & company stamp) Carl Zeiss Meditec USA, Inc. 5300 Central Parkway Dublin, CA 94568 USA Paul Swift, RAC Head of RA/CA, Americas +1 817-925-8507 [email protected]

Cover Letter(s)

Document Version 1.1 2020-10-30 LONG-TERM CONFIDENTIALITY REQUEST for Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 TO WHOM IT M AY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request Long-Term Confidentiality for the following product: For the product stated above, we request Long-Term Confidentiality for exhibits which contain Block Diagram, Operational Description, Parts List/Tune Up Info, Schematics, SDR Software/Security Info. The above exhibits contain ou r trade secrets and proprietary information that could be of benefit to o ur competitors. This information will not be publicly available. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Company Name: Phone: Company Address: Fax: E-mail: Contact Name: Signature: Signature Date: Check your GC here. Click Grantee Search. FCC I D: Grantee Code Equipment Product Code

External Photos

Annex A101 - Photographs No.1-2721/21-07-01_TR1-A101-R01 May 10, 2024 DescriptionExternal photographs of EUT This document is electronically signed and valid without handwritten signature. Public keys for verification of the electronic signatures can be requested at the testing laboratory. Authorized David Lang Lab Manager Radio Labs cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-2721/21-07-01_TR1-A101-R01 Release 1 - Page 1 of 4 Photo 1 Photo 2 cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-2721/21-07-01_TR1-A101-R01 Release 1 - Page 2 of 4 Photo 3 Photo 4 cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-2721/21-07-01_TR1-A101-R01 Release 1 - Page 3 of 4 Photo 5 Photo 6 - END OF DOCUMENT - cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-2721/21-07-01_TR1-A101-R01 Release 1 - Page 4 of 4

ID Label/Location Info

1 A B C Refer to protection notice ISO 16016 / copyright reserved D E F 2345678 Changed Checked Techn. GS Released Req. GS Scale Size Doc. typeDoc. partVersion Sh. of Document no. Drawn DateName Type of supplementary document Description Material number Project class, Component (level/ counter/ character) Basic material Mass Change number 66 R (4x) 0,5 3 0 5 7 18 5355 3 0 6 9 12 15 16 18,5 21 23,5 26 28,5 31 33,5 36 38,5 41 48,5 58 63 42 58 Confidential Model Name: 305992-8055-000_01-LOCAL Version: 08 CZ_1910 . 1:2 +0,50-0,05 +0,05-0,20General tolerances ISO 2768-mH:1989 . Size ISO 14405 • ISO 13715 12.04.2024NIEDEM - . . .. - .. 305992-8055-000 .. P30200006UM .. . .. EMV-Box, FBG Gateway, kpl. . .. 305992-8055-000/01FUM00108 1 A3 2 alle nicht gekennzeichneten Schriften: CZN 14 - Regular - 2 lasergraviert, schwarz all non-marked fonts: CZN 14 - Regular - 2 laser-engraved, black alle nicht bemaßten Radien = R2 all non-dimensioned radii = R2 Bildliche Darstellung der Schriftzüge, Symbole und Bildzeichen entsprechen nicht dem Original visual reproduction of the fonts, symbols and figurative signs does not correspond to the original umlaufend Schnittkante circumferential cutting Bildzeichen nach IEC/TR 60878:2003-Nr.5140 oder IEC 60417:2002 DB-Nr.5140 symbol according to IEC/TR 60878:2003-no.5140 or IEC 60417:2002 DB-no.5140 Strichstärke 0,3 umlaufend 1 mm Abstand zur innenligenden Schrift zur ober und unter line width 0.3 circumferential, 1 mm distance to the interior text to top and bottom Schrift CZN 14 - Regular - 1,5 font CZN 14 - Regular - 1.5 Bildzeichen nach 304972-1005-000_FPR-01-002 höhe / height 5 mm symbol according to 304972-1005-000_FPR-01- Schrift mittig angeordnet text centered MIC-Bildzeichen nach CETECOM ICT TCB Japan Instructions vom 01.2007 MIC-symbol according to CETECOM ICT TCB Japan Instructions from 01.2007 Höhe / height 5.5 mm Nur zur Information - Unterlage unterliegt nicht dem Änderungsdienst! Arbeitsstand vom: 25-Jun-24 . / For information purposes only - contents will be changed without notice! Output date: 25-Jun-24 . 1 A B C Refer to protection notice ISO 16016 / copyright reserved D E F 2345678 Changed Checked Techn. GS Released Req. GS Scale Size Doc. typeDoc. partVersion Sh. of Document no. Drawn DateName Type of supplementary document Description Material number Project class, Component (level/ counter/ character) Basic material Mass Change number ( ) 220 ()77,5 ()47,3 5 5 18 2 5 2 20 2 3 2 ZEISS_EHSM_CDO_TBL01 cad1cad2 spec allowed basic materials and surfaces Confidential Model Name: 305992-8055-000_01-LOCAL Version: 08 CZ_1910 1:2 +0,50-0,05 +0,05-0,20General tolerances ISO 2768-mH:1989 Size ISO 14405 • ISO 13715 12.04.2024NIEDEM 0,503kg 12.04.2024XSSHE 305992-8055-000 P30200006UM STATIVE KINEVO 900 EMC-box, PCB gateway, complete no 10165182 305992-8055-000/01FUM00108 2 A3 2 lose beigelegt/ enclosed: 501-167 ISO 10644-M3 x 6-St/A2K Torx (4x) A-A Nur zur Information - Unterlage unterliegt nicht dem Änderungsdienst! Arbeitsstand vom: 25-Jun-24 . / For information purposes only - contents will be changed without notice! Output date: 25-Jun-24 . Abstandsbolzen Ausf.A L 16 M3 St/Zn 534-929 2 x ISO 10644-M3x6-St/A2K Torx 501-167 2 x ISO 10644-M3x6-St/A2K Torx 501-167 5 x 305992-8056-000 UM 1 Durchführungstülle Neopren 8,0/W2,0mm sw 583-588 1 x 305992-0185-000 T M 1 304972-7203-000 TM 1 2660-037 TM 1 Radio label for FCP Gateway WL 2 304972-1007-000 1 x

Internal Photos

Annex B 1-2721/21-02-01_AnnexB Internal photos of the Equipment Under Test This addendum is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Document authorized: Michael Dorongovski Lab Manager Radio Communications & EMC CTC advanced GmbHUntertuerkheimer Str. 6-10 66117 Saarbruecken / Germany Phone: +49 681 5 98 - 0 Fax: +49 681 5 98 - 9075 web: ctcadvanced.com e-mail: [email protected] Photos Photo 1 Photo 2 2023-04-14Document No. 1-2721/21-02-01_AnnexB2/5 Photo 3 Photo 4 2023-04-14Document No. 1-2721/21-02-01_AnnexB3/5 Photo 5 2023-04-14Document No. 1-2721/21-02-01_AnnexB4/5 Document history VersionApplied changesDate of release initial release2023-04-14 - END OF DOCUMENT - 2023-04-14Document No. 1-2721/21-02-01_AnnexB5/5

Internal Photos

FCP Gateway WL 2 1 2

RF Exposure Info

© cetecom advanced GmbH Page 1 of 12 TEST REPORT Test report no.: 1-2712-21-07-05_TR1-R01 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 Carl Zeiss Meditec AG Goeschwitzer Strasse 51-52 07745 Jena / GERMANY Manufacturer Carl Zeiss Meditec AG Goeschwitzer Strasse 51-52 07745 Jena / GERMANY Test Item Kind of test item: Bluetooth Classic Application Model name: FCP Gateway WL 2 FCC ID: 2BF3L304972-8200 Frequency: 2.4 GHz Technology tested: Bluetooth ® + EDR This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: Alexander Hnatovskiy Eric Tuettmann Lab Manager Testing Manager Radio Labs Radio Labs Test report no.: 1-2712-21-07-05_TR1-R01 © cetecom advanced GmbH Page 2 of 12 1 Table of contents 1 Table of contents ............................................................................................................................................. 2 2 General Information ......................................................................................................................................... 3 2.1 Notes and Disclaimer ............................................................................................................................ 3 2.2 References ............................................................................................................................................ 3 2.3 Structure of this Document ................................................................................................................... 3 3 General RF Exposure Test Exemptions ............................................................................................................ 4 3.1 1 mW Test Exemption ........................................................................................................................... 5 3.2 MPE-Based Test Exemption ................................................................................................................. 5 3.3 SAR-Based Test Exemption .................................................................................................................. 5 3.4 Simultaneous Transmission ............................................................................................................... 6 4 1 mW Test Exemption ...................................................................................................................................... 7 4.1 Detailed Description .............................................................................................................................. 7 4.2 Results ................................................................................................................................................... 7 5 MPE-Based Test Exemption ............................................................................................................................ 8 5.1 Detailed Description .............................................................................................................................. 8 5.2 Results ................................................................................................................................................... 8 6 SAR-Based Test Exemption ............................................................................................................................. 9 6.1 Detailed Description .............................................................................................................................. 9 6.2 Results ................................................................................................................................................. 10 7 Simultaneous Transmission .......................................................................................................................... 11 7.1 Detailed Description ............................................................................................................................ 11 7.2 Result................................................................................................................................................... 11 8 Conclusion ...................................................................................................................................................... 12 Test report no.: 1-2712-21-07-05_TR1-R01 © cetecom advanced GmbH Page 3 of 12 2 General Information 2.1 Notes and Disclaimer The test results of this test report relate exclusively to the test item specified in this test report. cetecom advanced GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of cetecom advanced GmbH. The testing service provided by cetecom advanced GmbH has been rendered under the current "General Terms and Conditions for cetecom advanced GmbH". cetecom advanced GmbH will not be liable for any loss or damage resulting from false, inaccurate, inappropriate or incomplete product information provided by the custom…

Text truncated - open the document above for the full version.

Test Report

A The evolution of technology has brought the need to communicate everywhere and at all times without being confined to one space. Laird Technologies’ internal wireless device antennas feature wide bandwidth to enhance the performance and application of portable wireless devices based on standards such as 802.11 and Bluetooth®. The antennas are specifically designed to be embedded inside devices for aesthetically pleasing integration with high durability. ▪ Versatile, easy-to-use for 2.4 to 2.5 GHz Bluetooth® and IEEE 802.11 devices ▪ Designed for an easy connection to radio cards ▪ Uses patented PCB Microsphere technology ▪ Has a ground plane incorporated into the resonator structure – no additional ground plane is required to radiate efficiently Operating Frequency (MHz) 2.4 – 2.5 GHz VSWR – Max <2.5:1 Gain (dBi) 2 Nominal Impedance (Ohms) 50 Polarization Linear Dimensions 44.45 x 12.7 x 0.81 (1.75 x 0.5 x 0.032) Weight 2 g (0.071 oz.) MAF94045 100 mm, Ø 1.13 mm IPEX MHF MAF94102 100 mm, RG178 Flying Lead MAF95096 100 mm Right Angle MMCX EBL2400A1-10MH4L 100 mm MHF4 EBL2400R1-20MHF4 200 mm MHF4 R/A Plug EBL2400A-30RSMM 300 mm Reverse Polarity SMA Male [email protected] [email protected] www.lairdconnect.com Laird warrants to the original end user customer of its products that its products are free from defects in material and workmanship. Subject to conditions and limitations Laird will, at its option, either repair or replace any part of its products that prove defective because of improper workmanship or materials. This limited warranty is in force for the useful lifetime of the original end product into which the Laird product is installed. Useful lifetime of the original end product may vary but is not to exceed five (5) years from the original date of the end product purchase. Any information furnished by Laird Inc. and its agents is believed to be accurate and reliable. All specifications are subject to change without notice. Responsibility for the use and application of Laird materials rests with the end user, since Laird and its agents cannot be aware of all potential uses. Laird makes no warranties as to the fitness, merchantability or suitability of any Laird materials or products for any specific or general uses. Laird shall not be liable for incidental or consequential damages of any kind. All Laird products are sold pursuant to the Laird Terms and Conditions of sale in effect from time to time, a copy of which will be furnished upon request. © Copyright 2019 Laird Inc. All Rights Reserved. Laird, Laird Technologies, the Laird Logo, and other marks are trademarks or registered trademarks of Laird Inc. or an affiliate company thereof. Other product or service names may be the property of third parties. Nothing herein provides a license under any Laird or any third party intellectual property rights.

Test Report

TEST REPORT Test report no.: 1-2721-21-07-04_TR1-R01 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 Carl Zeiss Meditec AG Goeschwitzer Strasse 51-52 07745 Jena / GERMANY Manufacturer Carl Zeiss Meditec AG Goeschwitzer Strasse 51-52 07745 Jena / GERMANY Test standard/s FCC - Title 47 CFR Part 15 FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency devices RSS - 247 Issue 3 Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence-Exempt Local Area Network (LE-LAN) Devices For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Bluetooth Classic Application Model name: FCP Gateway WL 2 FCC ID: 2BF3L304972-8200 ISED certification number: 7781A-3049728200 Frequency: 2400 MHz to 2483.5 MHz Technology tested: Bluetooth ® + EDR Antenna: External antenna Power supply: 15 V DC by external power supply Temperature range: -20°C to +55°C This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: Marco Bertolino Michael Dorongovski Supervisor Radio Services Lab Manager Radio Labs Radio Labs Test report no.: 1-2721-21-07-04_TR1-R01 © cetecom advanced GmbH Page 2 of 47 1 Table of contents 1 Table of contents .................................................................................................................................... 2 2 General information ................................................................................................................................ 3 2.1 Notes and disclaimer .................................................................................................................... 3 2.2 Application details ........................................................................................................................ 3 2.3 Test laboratories sub-contracted .................................................................................................. 3 3 Test standard/s, references and accreditations ....................................................................................... 4 4 Reporting statements of conformity – decision rule ................................................................................ 5 5 Test environment.................................................................................................................................... 6 6 Test item ................................................................................................................................................ 6 6.1 General description ...................................................................................................................... 6 6.2 Additional information .................................................................................................................. 6 7 Sequence of testing ................................................................................................................................ 7 7.1 Sequence of testing radiated spurious 9 kHz to 30 MHz ................................................................ 7 7.2 Sequence of testing radiated spurious 30 MHz to 1 GHz ............................................................... 8 7.3 Sequence of testing radiated spurious 1 GHz to 18 GHz ................................................................ 9 7.4 Sequence of testing radiated spurious above 18 GHz .................................................................. 10 8 Description of the test setup ................................................................................................................. 11 8.1 Shielded semi anechoic chamber ................................................................................................ 12 8.2 Shielded fully anechoic chamber ................................................................................................ 13 8.3 Radiated measurements > 18 GHz .............................................................................................. 14 8.4 Conducted measurements system .............................................................................................. 15 8.5 AC conducted ............................................................................................................................. 16 9 Measurement uncertainty ..................................................................................................................... 17 10 Summary of measurement results .................................................................................................. 18 11 Additional comments ..................................................................................................................... 19 12 Measurement results ..................................................................................................................... 20 12.1 Antenna gain ........................................................................................................................... 20 12.2 Carrier frequency separation ................................................................................................... 21 12.3 Number of hopping channels ...............................…

Text truncated - open the document above for the full version.

Test Report

Conducted test results No.1-2721-21-07-04_TR1-A201-R1 May 08, 2024 Test Standard(s)FCC 15.247 - NI FCC 15.247, ISED RSS247 - NI This document is electronically signed and valid without handwritten signature. Public keys for verification of the electronic signatures can be requested at the testing laboratory. Authorized Joerg Warken Lab Manager Radio Labs cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-2721-21-07-04_TR1-A201-R1 Release 1 - Page 1 of 100 Table of Content FCC 15.247 # Maximum peak conducted output power FHSS ~ BT Classic Basic rate3 FCC 15.247 # Maximum peak conducted output power FHSS ~ BT…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Juergen Berger(Dr)
[email protected]+497364207717Fax: +497364207533

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]49-681-598-0Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.04 mW
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted.