Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Model No.:RH-WV2021 A. INTRODUCTION RHINO Wat er Valve*1 3/4" inch-NPT thread RHINO Wat er Valve*1 3/4" inch-NPT thread User Manual*1 1. CONTENTS IN THE BOX 2. PRODUCTS OVERVIEW Outlet Mechanical button AC hole knob Intlet LED indicat or * Remote contr ol wat er valve * Three modes on the APP - home/away/disarm mode * Trigger corresponding alarms and actions when preset conditions reached * Manually open/close valve * External backup power * Anti-scaling self-test function * Wat er leakage alarm * Wat er pipe leak detec tion 3. FUNCTIONS * 3/4" NPT inlet * 3/4" NPT outlet * Product dimensions – L x W x H: 136X65X119.5mm (not include inlet/outlet screw) * Operating voltage: DC 12V * Working wat er pressure: 0 bar to 12 bar (0 PSI-180PSI) * Flow rat e: 0.5L/min to 30L/min (0.13GAL/min to 7.92GAL/min) * Wat erproof r ating: IPX6 * Operating temperature: 1°C to 50°C (33.8°F t o 122°F) * Stor age temperature: -20°C to 60°C (-4°F t o 140°F) * Product accuracy (%) ±10% B. INSTALLATION * Check the user guide befor e installation rec ommended * Open main wat er supply and RHINO only after installation and commission. * Must be installed after wat er meter , water shut-off , and pressure regulating valve (if applicable) * Do not use the RHINO and adapter when the operating temperature is exceeded. * AC power (100-240VAC-50/60 Hz) is required when connecting with WiFi * The installation requires a professional plumber to complete or have it installed under the guidance of a professional. 1. Valve Installation Notes (R ec ommened Horizontal Placement outin out in * Register your RhinoH account Open the APP, select Set Up Follow the prompts to register an account with your email . Note: stage. You may be prompted to allow access your location. This allows the app to show weather information, and can still function if you choose to opt out. * Download the RhinoH App Search for RhinoH on Google Play or App Stor e or scan the QR code to download. 2. App Installation St ep1: Power the Rhino 3. Connect the RHINO St ep2: Open the App and tap Add device or + t o add a new device St ep3: Y choose Add St ep4: Or tap the icon circled for connection 1.EZ Mode The device supports two distinct networking modes for configuration. St ep5: Wait few seconds when connecting, and you will get it connected. 2.AP Mode St ep1: Power the Rhino St ep2: Open the App and tap Add device or + t o add a new device St ep3: Tap the icon circled for connection * Hold the RESET button for 5s. * Hold the RESET button for 5s again until the indicat or is blinking slowly. St ep4: Select 2.4GHz Wi-Fi Network. St ep5: Reset the device. St ep6: Connect your mobile phone to the device’s hotspot. St ep7: Wait few seconds when connecting, and you will get it connected. 4. Device Par ameter Tap to check more info Historical wat er consumption Total wat er usage Wat er Temperature Adjustable wat er Real time wat er pr essure Three modes: Home/ Away/Disarm and Settings 1) Press the button to open the valve, the button icon will switch to ON when it’s completed. Simultaneously, the indicator dial on the RHINO apparatus will also rotate to the ON position. 2) Press the button to close the valve, the button icon will switch to OFF when it’s completed. Simultaneously, the indicator dial on the RHINO apparatus will also rotate to the OFF position. 5. Device Programming [1][2] * Historical wat er consumption 1) Click the icon t o enter this section. You may check the wat er consumption and the remaining wat er( activat e it by setting up a wat er consumption limit on Settings page) in current day/week/month. need and type in the email adress, click sa ve. C. SETTINGS Pr ess Settings ic on to enter into the setting mode 1) Unit Settings You have the option to change the water measurement unit (L/GAL), temperature unit (°C/°F), and water pressure unit(KPa/PSI). You have the option to enable/disable the notifications within the current status. (Home/Away/Disarm) 3) Mode Settings There are three mode settings of RHINO - Home, Away,Disarm. The default settings of Three modes: 4) Wat er consumption limit You may set up the wat er consumption limit per current day/week/month, click sa ve f or saving settings. sa ve for saving settings. 7) Plumbing health check This Function is dedicated to identifying potential leaks within your household. Initiate the process by pressing “Start Checking” and confirming the test. The Drip Leak Test will operate for a duration of 15 minutes. If there’ s no wat er in the pipeline, the test would be canceled automatically. Upon detecting a water leak ,"Drip Detected" notification will be issued. linkage rec or ds of RHINO. D. RESET THE DEVICE Option 1 Remove the device on the App Pr ess the Remove Device Select the Disconnect and wipe data Option 2 * White LED light is always on: the connection succeeded and valve is open * Red LED light is always on: the connection succeeded and valve is closed E. LED LIGHT INDICATION F. TROUBLESHOOTING Pr oblemPos sible CausePos sible Solution Valve can not close No LED indicat or White LED still blink af ter valve’ s connected * anything stuck inside the pipe? * the temperature is lower than 1°C (33.8°F)? * Is the extenal power connected? * Is the valve online and connected successfully * Check y our electricity supply the connection on App * Clean the pipe * Use the valve under working temperature NSF/ANSI/CAN 61 Drinking Water System Components - Health Effects. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600. G. CERTIFICATE AND STANDARDS FCC Caution: Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that …
Text truncated - open the document above for the full version.
14403436 Canada inc Address: unit1-146 west beaver creek road, richmond hill, L4B1C2, Canada Tel: +1 6476682666 Email: [email protected] Date: 2024-06-19 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Attestation letter Dear Sir or Madam, Our product Rhino Smart Water Valve, model: RH-WV2021, FCC ID: 2BF8P-RHWV2021, for marketing purpose, this product only supports BLE 1M, 2.4GWi-Fi (2412-2462MHz, 802.11b/g/n20/n40 modes).The other functions, bands and modes was disabled to use by manufacturer in the software, the end user has no capability to activate it. We affirm that the antenna as shown in the picture below, installed in our product, but for marketing purpose, this antenna was disabled to use by manufacture in the software, the end user has no capability to activate it. Sincerely, Signature: Qi Cui Director
14403436 Canada inc Address: unit1-146 west beaver creek road, richmond hill, L4B1C2, Canada Tel: +1 6476682666 Email: [email protected] CFR 47 §2.911(d)(5)(i) Attestation Letter Attestation Letter Date: 2024-06- 19 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID: 2BF8P-RHWV2021 14403436 Canada inc certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Signature: Qi Cui Director
14403436 Canada inc Address: unit1-146 west beaver creek road, richmond hill, L4B1C2, Canada Tel: +1 6476682666 Email: [email protected] CFR 47 §2.911 (d)(5)(ii) Attestation Letter Attestation Letter Date: 2024-06-19 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID: 2BF8P-RHWV2021 14403436 Canada inc certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature: Qi Cui Director
14403436 Canada inc Address: unit1-146 west beaver creek road, richmond hill, L4B1C2, Canada Tel: +1 6476682666 Email: [email protected] QA-FR-170-B 7/29/2014 FCC Authorization Date: 2024-06-19 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We 14403436 Canada inc, the undersigned, hereby authorizes Bay Area Compliance Laboratories Corp. (Shenzhen) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. (Shenzhen) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Qi Cui Director
14403436 Canada inc Address: unit1-146 west beaver creek road, richmond hill, L4B1C2, Canada Tel: +1 6476682666 Email: [email protected] FCC Confidential Authorization Date: 2024-06-19 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2BF8P-RHWV2021 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, 14403436 Canada inc hereby requests long-term confidential treatment of information accompanying this application as outlined below: • Block Diagram • Schematics • Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Qi Cui Director
Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401T52529E-RF Page 1 of 5 EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401T52529E-RF Page 2 of 5 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401T52529E-RF Page 3 of 5 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401T52529E-RF Page 4 of 5 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401T52529E-RF Page 5 of 5
Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401T52529E-RF EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)
Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401T52529E-RF Page 1 of 8 EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401T52529E-RF Page 2 of 8 ANT Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401T52529E-RF Page 3 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401T52529E-RF Page 4 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401T52529E-RF Page 5 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401T52529E-RF Page 6 of 8 No used antenna Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401T52529E-RF Page 7 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401T52529E-RF Page 8 of 8
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401T52529E-RF TR-EM-RF010 Page 17 of 90 Version 1.0 (2023/10/07) FCC §15.247 (I) & §1.1307 (B) (3) & §2.1091- MPE-BASED EXEMPTION Applicable Standard According to subpart 15.247 (i) and subpart 2.1091 systems operating under the provisions of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in excess of the communication guidelines. According to KDB 447498 D04 Interim General RF Exposure Guidance MPE-Based Exemption: General frequency and separation-distance dependent MPE-based effective radiated power (ERP) thresholds are in Table B.1 [Table 1 of § 1.1307(b)(3)(i)(C)] to support an exemption from further evaluation from 300 kHz through 100 GHz. For multiple RF sources: Multiple RF sources are exempt if: in the case of fixed RF sources operating in the same time-averaging period, or of multiple mobile or portable RF sources within a device operating in the same time averaging period, if the sum of the fractional contributions to the applicable thresholds is less than or equal to 1 as indicated in the following equation: Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401T52529E-RF TR-EM-RF010 Page 18 of 90 Version 1.0 (2023/10/07) Result Mode Frequency (MHz) Tune up conducted power # Antenna Gain # ERP Evaluation Distance (m) ERP Limit (W) (dBm) (dBi)(dBd)(dBm)(W) BLE 2402-24809.5 5.45 3.30 12.80 0.019 0.2 0.768 2.4G Wi-Fi 2412-246220.5 5.45 3.30 23.80 0.240 0.2 0.768 Note: 1. The tune up conducted power and antenna gain was declared by the applicant. 2. The BLE/Wi-Fi cannot transmit at the same time. 3. 0dBd=2.15dBi To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm from nearby persons. Result: Compliant.
SHENZHENFEISHENGELECTRONICSCO.,LTD. 1 TianchengBaodeFPCantennaspecificationrecognitionletter CustomerName: Fujiantianchengbaodeenvironmentprotection co.,ltd Antennafrequencyband:2400-2500MHz Version:A0 Productiondate:2024-06-27 Number:FS-673 ResearchanddevelopmentofFeishengElectronicsCo., Ltd. Structures : XuLong RF : GuoXi Auditing:GuZhifeiAppreval:GuZhifei Customerconfirmation Customerreview : Customer approval: FeishengElectronicsCo.,Ltd. Address:ThirdFloor,No.70BaotongSouthRoad,YunguStreet,Xikeng,HenggangTown,Shenzhen Phonenumber:0755-85218289FAX:0755-85223189 SHENZHENFEISHENGELECTRONICSCO.,LTD. 2 INDEX. 1)Covercover.................................................................................1 2)Catalog........................................................................................2 3)2Ddrawings................................................................................3 4)Productspecificationparameters................................................4 5)Testreportofpassivewaveformlossvalue.............................5-8 6)Environmentaltestreport....................................................9-12 Modifytherecord VersionsDatesRFModifythecontent A02024-06-27XuLong 3 SHENZHENFEISHENGELECTRONICSCO.,LTD. 4 ProductFeaturesSpecificationTable 一、Basiccharacteristicsoftheproduct: Producttype:FPCantennaWIFI-1.13IPEXfirstgenerationterminal -1.13wiredoubletinblackL=120MM DESCRIPTIONVALUE FrequencyRange2400-2500MHz Impedance50 Ω VSWRComparethewaveformsofsamples Gain5.45dBi RadiationOmni-directional PolarizationlinearVertical Powers1W ConnectormodelIPEX Operatingtemperature-45 °C ~+85 °C Storagetemperature-45°C~+85°C SHENZHENFEISHENGELECTRONICSCO.,LTD. 5 1.Summary: ThisreporttoaccountforthemeasurementsetupandresultoftheAntenna.Themeasurement setupincludess-parameter,ThemeasureddataforAntennaarepresentedandanalysis. 2.S-ParameterMeasurementS: A.Reflectioncoefficient: (a)Instrument:NetworkAnalyzer (b)Setup: (1)CalibratetheNetworkAnalyzerbyoneportcalibrationusingO.S.L.calibrationkits. (2)ConnecttheantennaundertesttotheNetworkAnalyzer. (3)MeasuretheS11(reflectioncoefficient)showninFig.1. (4)Generally,theS11islessthan–10dBtoensurethe90%VSWR2.0:1powerinto antennaandonlylessthan10%powerbacktosystem. 一 Fig.1AntennameasuredinNetworkAnalyzer SHENZHENFEISHENGELECTRONICSCO.,LTD. 6 3.S-ParameterMeasurementResultS: S-Parametertestdata:(Aerialsurvey) S-Parametertestimage: FrequencyMHz 240024502500 V.S.W.R1.882.132.64 SHENZHENFEISHENGELECTRONICSCO.,LTD. 7 Machineappearance: Passivevalue: SHENZHENFEISHENGELECTRONICSCO.,LTD. 8 2D、3D: SHENZHENFEISHENGELECTRONICSCO.,LTD. 9 Environmentaltestrequirements PrefaceTestitemsTestmethodsandconditionsTestequipmentTestresults 1 Temperature and humidity test ReferenceE1A364-31MethodThree,Test ConditionA Thepurposeofthistestprocessisto conductdetailedstandardtests.The productsusedareaffectedbyhigh humidityandheat.Influencethe performanceofthematerialfor evaluation. K.SONINS THS-A4L-150 Qualified Requirements: Temperature:85°C Humidity:90~95%(R.H) Time:72hours 2 Low temperature test RefertoFeishengElectronicTest Specification Themeasuredsampleshouldbetraveledin atemperature-balancedenvironment,and itstemperaturesetting Setat-45°C K.SONINS THS-A4L-150 Qualified Requirements: Time:24hours 3 High temperature test RefertoFeishengElectronicTest Specification: Themeasuredsampleshouldbeplacedina constanttemperatureenvironment,andthe gastemperatureshouldbesetat70°C. K.SONINS THS-A4L-150 Qualified Requirements: TIne:24hours SHENZHENFEISHENGELECTRONICSCO.,LTD. 10 Environmentaltestrequirements PrefaceTestitemsTestmethodsandconditionsTestequipmentTestresults 4 Hotandcold tests RefertoFeishengElectronicTest Specification: Themeasuredsampleshouldbeplacedina fixedenvironment,andthetemperature shouldbesetat-45~85°C. K.SONINS THS-A4L-150 Qualified Requirements: Morethan8hours.(30minutes/time,12 cycles) 5 Salt spraytest RefertoFeishengElectronicTest Specification: Thetestedsampleshouldbeplacedina fixedenvironment: NaCLConcentration:40-60g/1Kg PHvalue:6.5-7.2 Testtime:24hours Saltspray tester Qualified 1.Gold-platedproductsarenotallowedto peelwithrustspots. 2.Othernickel-plated,tinnedand galvanizedproductsshallnothavemore thantworustpointsonthesameshaftor surface. SHENZHENFEISHENGELECTRONICSCO.,LTD. 11 Mechanicaltestrequirements PrefaceTestitemsTestmethodsandconditionsTestequipmentTestresults 1Vibration test TestconditionA Thepurposeofthistestprocessisto evaluatetheproductsusedinthedetailed standardtestmethods,whicharemovedor movedtoaffecttheperformanceofthe material. Vibration tester Qualified Requirements: Vibrationrange:10-55HZ Displacementamplitudevalue:0.35mm Accelerationamplitude:50.0M/S Numberoffrequencysweepingcycles: 30Times 2 DROPTESTS RefertoFeishengElectronicTest Specification: Themeasuredsampleshouldbeplacedata certainheight,anditsheightshouldbe setto1meter,anditshouldfallfreely 3timesinthedirectionof6surfaces. Droptest fixtures Qualified Requirements: Themechanicalcharacteristicsofthe productarenormalafterthedroptest. SHENZHENFEISHENGELECTRONICSCO.,LTD. 12 Mechanicaltestrequirements 3 Tulatest RefertoFeishengElectronicTest Specification: Fixtheobjectundertestthroughthe fixture,andafterapplyingacertainforce intheoppositedirection,theproduct assemblyshallnotfalloff. TiletesterQualified Requirements: 1.Theproductassemblycannotfalloff. 2.Minimumtensileforce:1.2KG Note:FeishengElectronicsperformstheabovemechanicalandenvironmentalparametertestsbeforeR&Dand trialdelivery.
Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF010 Page 1 of 90 Version 1.0 (2023/10/07) TEST REPORT Applicant Name: FCC: 14403436 Canada inc IC: 14403436 canada inc Address: FCC : unit1-146 west beaver creek road, richmond hill, L4B1C2, Canada IC: unit1-146 west beaver creek road, Richmond Hill, ON, L4B 1C2, Canada Report Number: 2401T52529E-RF FCC ID: 2BF8P-RHWV2021 IC: 32404-RHWV2021 Test Standard (s) FCC PART 15.247 RSS-GEN ISSUE 5, FEBRUARY 2021 AMENDMENT 2; RSS-247 ISSUE 3, AUGUST 2023 Sample Description Product Type: Rhino Smart Water Valve Model No.: RH-WV2021 Multiple Model(s) No.: N/A Trade Mark: RHINO Date Received: 2024/05/11 Issue Date: 2024/07/09 Test Result: Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By: Approved By: Bruce Lin Michelle Zeng RF Engineer RF Supervisor Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401T52529E-RF TR-EM-RF010 Page 2 of 90 Version 1.0 (2023/10/07) TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 4 GENERAL INFORMATION ....................................................................................................................................... 5 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 5 OBJECTIVE ................................................................................................................................................................... 5 TEST METHODOLOGY .................................................................................................................................................. 5 MEASUREMENT UNCERTAINTY .................................................................................................................................... 6 TEST FACILITY ............................................................................................................................................................. 6 SYSTEM TEST CONFIGURATION .......................................................................................................................... 7 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 7 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 8 EUT EXERCISE SOFTWARE .......................................................................................................................................... 8 DUTY CYCLE ................................................................................................................................................................ 8 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................. 12 EXTERNAL I/O CABLE ................................................................................................................................................ 12 BLOCK DIAGRAM OF TEST SETUP .............................................................................................................................. 12 SUMMARY OF TEST RESULTS ............................................................................................................................. 14 TEST EQUIPMENT LIST ......................................................................................................................................... 15 FCC §15.247 (I) & §1.1307 (B) (3) & §2.1091- MPE-BASED EXEMPTION ........................................................ 17 APPLICABLE STANDARD ............................................................................................................................................ 17 RESULT ...................................................................................................................................................................... 18 RSS-102 § (2.5.2) –EXEMPTION LIMITS FOR ROUTINE EVALUATION-RF EXPOSURE EVALUATION19 APPLICABLE STANDARD ............................................................................................................................................ 19 RESULT ...................................................................................................................................................................... 19 §15.203 & RSS-GEN §6.8 ANTENNA REQUIREMENT ........................................................................................ 20 APPLICABLE STANDARD ............................................................................................................................................ 20 ANTENNA CONNECTOR CONSTRUCTION ...…
Text truncated - open the document above for the full version.
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401T52529E-RF Page 1 of 3 EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions - Front View Conducted Emissions - Side View Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401T52529E-RF Page 2 of 3 Radiated Emissions View (Below 30MHz) Radiated Emissions View (Below 1 GHz) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401T52529E-RF Page 3 of 3 Radiated Emissions View (1-18 GHz) Radiated Emissions View (18-25 GHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.40 GHz - 2.48 GHz | 8.00 mW |

ValveCore
Equipment Class
DTS - Digital Transmission System
Rhino Smart Water Meter/Rhino Leak Defense
Equipment Class
DTS - Digital Transmission System